SINTRAN III Line Printer Configuration Inspection Guide

Overview

This document provides a complete diagnostic guide for SINTRAN III line printer configuration issues, specifically the "NO SUCH LOGICAL UNIT" (error 33) failure when using @COPY-FILE LINE-PRINTER, source-file. It covers the root cause analysis, boot pipeline, symbol cross-references for multiple SINTRAN versions, and step-by-step fix instructions.

Applies to: SINTRAN III versions K03, L07, M06 Target audience: ND-100 emulator developers and SINTRAN system administrators Created: 2026-03-05


Table of Contents

  1. Root Cause Analysis
  2. Boot Pipeline: From LPSELECTION to Print Output
  3. Printer Types in SINTRAN
  4. Symbol Cross-Reference Table
  5. LPTA Entry Structure
  6. Memory Inspection Checklist
  7. Fix: Patching LPSELECTION
  8. Verification After Patching
  9. Fallback: Debugging Hardware Detection
  10. EXR ST vs IOXT Analysis
  11. Data Flow: Working Print Path
  12. Key Source Files

Root Cause Analysis

Symptom

@COPY-FILE LINE-PRINTER, source-file returns error 33: "NO SUCH LOGICAL UNIT"

Error Mechanism

The error originates in RP-P2-MONCALLS.NPL:

112256: A:=D; CALL LOGPH                % GET ADDR OF DATAFIELDS
...
107240: IF A=0 GO ERR                   % NO SUCH LOGICAL UNIT

Note: The body of LOGPH is not in any of the 45 available NPL source files. However, a boot-time simulation (CLOGPH/XLOGPH) in PH-P2-OPPSTART.NPL:182 reveals the exact algorithm:

ILOGPH: AD SHZ -6;                              % Extract group from LDN (shift right 6)
        IF A=1 OR A=RDLNO OR A>LGDGMAX THEN
           CALL ERRFATAL
        FI
        A=:X:=D SHZ -12
        A+A+CCNVRT(X)+1=:D; *1BANK              % CCNVRT[group] = table base, slot = index*2+base+1
        IF A-ENTAB(X)>=0 THEN CALL ERRFATAL FI   % Bounds check
        *2BANK
        X:=D; *POF; LDD ,X; PON                  % Read double word: A=input DF, D=output DF
        IF K THEN
           IF A><0 THEN X:=A ELSE X:=D FI        % Return non-zero DF
        ...
        IF X=0 THEN CALL ERRFATAL FI              % Error if both are 0

For logical device 5 (LPLOGNO=5): group=0 (5 >> 6 = 0), index=5. LOGPH looks up CNVRT[0] to find the device group table base, then reads the double word at slot 5. If both words are 0 (LDNT not populated), LOGPH returns 0, and RP-P2-MONCALLS triggers error 33.

Root Cause

LPSELECTION = 0 at the LPTA table base address (036370₈ for L07).

The LPTA table is static compiled data in PH-P2-CONFG-TAB.NPL. The first word of each entry (LPSELECTION) is controlled by the SINGEN macro "8LP1:

DATA( 0,    5, 1167, IDMP1, DILP1,  DLPR, DMPR1, DMLP1,  DLPR, 140230,  3,  3, 0,0,0,0) % LINE PRINTER 1.

The 0 at position 0 is LPSELECTION. Note that all datafield pointers (IDMP1, DILP1, DLPR, DMPR1, DMLP1) and ident codes (140230, 3, 3) are already filled in regardless of LPSELECTION. Only LPSELECTION itself is 0 because SINGEN did not configure a printer type.

When LPSELECTION=0, the boot code CHLPS (line 457: IF A=0 OR A>>3 THEN) immediately sets LPCLENTRY=1 and skips the printer. Then XCHLPS (line 2124: IF X.LPCLENTRY><0 THEN) sees LPCLENTRY != 0 and calls CLLPENTRY which clears the LDNT entry for device 5. Result: LOGPH(5) returns 0.

flowchart TD
    SINGEN["SINGEN: No printer configured"]
    LPSEL["LPSELECTION = 0 on disk"]
    CHLPS["CHLPS: Checks LPSELECTION"]
    SKIP["LPSELECTION=0 -> LPCLENTRY=1"]
    XCHLPS["XCHLPS: Sees LPCLENTRY != 0"]
    CLEAR["CLLPENTRY: Clears LDNT for device 5"]
    COPY["COPY FILE LINE PRINTER"]
    LOGPH["LOGPH: LDNT entry = 0"]
    ERR["Error 33: NO SUCH LOGICAL UNIT"]

    SINGEN --> LPSEL --> CHLPS --> SKIP --> XCHLPS --> CLEAR
    COPY --> LOGPH --> ERR

    classDef error fill:#F44336,stroke:#C62828,stroke-width:2px,color:#fff
    classDef warn fill:#FFA726,stroke:#F57C00,stroke-width:2px,color:#000
    classDef hw fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff
    classDef data fill:#009688,stroke:#00695C,stroke-width:2px,color:#fff

    class SINGEN,LPSEL warn
    class CHLPS,XCHLPS hw
    class SKIP,CLEAR,LOGPH error
    class ERR error
    class COPY data

Why There Is No Auto-Discovery

The CHLPS code (L07 source, PH-P2-OPPSTART.NPL:455-478) shows a strict gate at line 457:

IF A=0 OR A>>3 THEN
   1=:X.LPCLENTRY; GO NXLPENTRY    % ILLEGAL SELECTION (OR DON'T USE THIS L-P)
FI

CHLPS only proceeds to hardware testing when LPSELECTION is 1, 2, or 3. The hardware test (EXR ST or IOXT) only verifies that a device responds at the expected IOX address -- it does not scan for unknown devices or determine what type of printer is attached. The printer type must be set in the LPTA table by SINGEN at system generation time. If LPSELECTION=0, no hardware test is attempted and no LDNT entry is created.


Boot Pipeline: From LPSELECTION to Print Output

Phase 1: CHLPS - Hardware Detection

Source: PH-P2-OPPSTART.NPL:454-478 (exact L07 source code)

043427   INTEGER CSVXY
043430   CHLPS: "0LPTA"=:CSVXY; *1BANK
043433          DO WHILE CSVXY.LPSELECTION><-1                      % -1: END OF TABLE
043440             IF A=0 OR A>>3 THEN
043444                1=:X.LPCLENTRY; GO NXLPENTRY                  % ILLEGAL SELECTION (OR DON'T USE THIS L-P)
043447             FI; A-1+"LPIODF"; X+A
043452             IF X.LPIODF=0 OR X.XLPDMDF=0 THEN                % DATAFIELD(S) NOT GENERATED
043456                1=:CSVXY.LPCLENTRY; GO NXLPENTRY
043462             FI; *2BANK
043463             T:=A.HDEV+2; A:=200; *TRR IIE; TRA IIC; 1BANK
043472             IF CSVXY.LPSELECTION-2=0 THEN
043476                *EXR ST
043477             ELSE
043500                *IOXT
043501             FI; *TRA IIC
043502             IF A><0 THEN 1=:X.LPCLENTRY FI                   % INTERFACE NOT PRESENT
043505   NXLPENTRY:
043505             IF CSVXY.LPSELECTION><3 OR X.LPCLENTRY><0 THEN
043514                X.LPLOGNO=:D; X:="IOBUTAB"
043517                DO WHILE X<<"EIOBUTAB"
043522                   IF X.S0/\7777=D THEN 0=:X.S0 FI            % REMOVE FROM IOBUTAB
043527                   X+2
043530                OD
043531             FI; CSVXY+LPTBSIZE=:CSVXY
043534          OD; *2BANK

Line-by-line analysis:

Line Code Effect
455 "0LPTA"=:CSVXY Load pointer to LPTA table (036370₈ in L07)
456 DO WHILE CSVXY.LPSELECTION><-1 Loop until terminator word (-1 = 177777₈)
457 IF A=0 OR A>>3 THEN Gate: LPSELECTION must be 1, 2, or 3
458 1=:X.LPCLENTRY; GO NXLPENTRY Fail A: mark disabled, skip
459 A-1+"LPIODF"; X+A Compute I/O datafield pointer for this type (1->offset+3, 2->offset+4, 3->offset+5)
460 IF X.LPIODF=0 OR X.XLPDMDF=0 Check both I/O and DMA datafield addresses exist
461 1=:CSVXY.LPCLENTRY; GO NXLPENTRY Fail B: datafield not generated
463 T:=A.HDEV+2 T = hardware device address + 2 (status register)
463 A:=200; *TRR IIE; TRA IIC Enable IOX error trap: if IOX fails, A becomes non-zero
464-468 IF CSVXY.LPSELECTION-2=0 THEN *EXR ST ELSE *IOXT Type 2: execute T as instruction; Type 1/3: IOX test via T
469 IF A><0 THEN 1=:X.LPCLENTRY FI Fail C: IOX error means hardware not present
471 IF CSVXY.LPSELECTION><3 OR X.LPCLENTRY><0 Clean up IOBUTAB for disabled printers or non-serial types
477 CSVXY+LPTBSIZE=:CSVXY Advance to next LPTA entry (16 words)

CHLPS Decision Flow:

flowchart TD
    START["CHLPS: Load LPTA table"]
    LOOP{"LPSELECTION != -1?"}
    CHKSEL{"LPSELECTION\n1, 2, or 3?"}
    FAILA["FAIL A:\nLPCLENTRY = 1"]
    CHKDF{"Datafield ptrs\nnon zero?"}
    FAILB["FAIL B:\nLPCLENTRY = 1"]
    LOADHDEV["T = HDEV + 2\nEnable IIE"]
    CHKTYPE{"LPSELECTION\n= 2?"}
    EXRST["EXR ST\nType 2 Parallel"]
    IOXT["IOXT\nType 1 or 3"]
    CHKHW{"Hardware\nfound?"}
    FAILC["FAIL C:\nLPCLENTRY = 1"]
    OK["LPCLENTRY = 0\nPrinter active"]
    NEXT["Next LPTA entry"]
    DONE["End CHLPS"]

    START --> LOOP
    LOOP -->|"Yes"| CHKSEL
    LOOP -->|"No, terminator"| DONE
    CHKSEL -->|"Valid 1 2 3"| CHKDF
    CHKSEL -->|"0 or >3"| FAILA
    CHKDF -->|"Non zero"| LOADHDEV
    CHKDF -->|"Zero"| FAILB
    LOADHDEV --> CHKTYPE
    CHKTYPE -->|"Yes, Type 2"| EXRST
    CHKTYPE -->|"No, Type 1 or 3"| IOXT
    EXRST --> CHKHW
    IOXT --> CHKHW
    CHKHW -->|"Present"| OK
    CHKHW -->|"IOX error"| FAILC
    FAILA --> NEXT
    FAILB --> NEXT
    FAILC --> NEXT
    OK --> NEXT
    NEXT --> LOOP

    classDef error fill:#F44336,stroke:#C62828,stroke-width:2px,color:#fff
    classDef success fill:#4CAF50,stroke:#2E7D32,stroke-width:2px,color:#fff
    classDef hw fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff
    classDef decision fill:#FFA726,stroke:#F57C00,stroke-width:2px,color:#000
    classDef process fill:#009688,stroke:#00695C,stroke-width:2px,color:#fff

    class FAILA,FAILB,FAILC error
    class OK success
    class EXRST,IOXT,LOADHDEV hw
    class CHKSEL,CHKDF,CHKTYPE,CHKHW,LOOP decision
    class START,NEXT,DONE process

Fail Points Summary:

Fail Point Condition Result
A LPSELECTION=0 or >3 LPCLENTRY=1, printer skipped
B Datafield address is 0 LPCLENTRY=1, printer skipped
C Hardware test fails (IOX error) LPCLENTRY=1, printer skipped

Phase 2: XCHLPS - LDNT Population

Source: PH-P2-OPPSTART.NPL:2120-2156 (exact L07 source code)

053515   INTEGER CSXXY,CLPSELECTION
053517   XCHLPS:
053517          "0LPTA"=:CSXXY; *1BANK
053522          DO WHILE CSXXY.LPSELECTION><-1
053527             IF X.LPCLENTRY><0 THEN
053531                CALL CLLPENTRY; GO NXTLP              % CLEAR ALL TABLE-ENTRIES FOR THIS L-P
053533             FI
053533             IF CSXXY.LPSELECTION=3 THEN
053540                A:=0                                  % NO DMA-DF
053541             ELSE
053542                A-1+"LPDMDF"; X+A; X.S0               % DMA-DF
053546             FI
053546             A=:D:=CSXXY.LPSELECTION
053551             A-1+"LPIODF"; X+A; X.S0
053555             X:=CSXXY
053556             CALL FAR UPDLPLOGNO                      % UPDATE LOG.DEV.NO TABLE
053557             IF CSXXY.LPSELECTION=1 THEN              % "DMPR-TYPE" PRINTER
053564                X.2LPIDENT; *2BANK
053566                CALL FAR 10IDCLEAR                    % CLEAR ENTRY IN LEVEL 10 IDENT-CODE-TABLE
053567             ELSE
053570                T:=X.2LPIDENT; A-1+"LPDMDF"; X+A; X.S0=:D
053576                "ITB10"-"PITEX"=:X; *2BANK
053602                A:=MPIFPHPAGE SH 12; X+A+T-1          % X=ADDR IN IDENT-CODE-TABLE (ITB10)
053607                T:=MPIBANK; A:=D; *STATX; 1BANK       % UPDATE IDENT-CODE TABLE
053613                CSXXY.1LPDMDF; *2BANK
053616                CALL FAR 11EIDCLEAR                   % CLEAR "DMPR-TYPE" FROM EXTENDED-IDENT-CODE-TABLE
053617             FI; *1BANK
053620             1=:CLPSELECTION
053622             DO WHILE CLPSELECTION<<=3
053626                IF CLPSELECTION><CSXXY.LPSELECTION THEN
053633                   A-1+"LPDMDF"; X+A; X.S0; *2BANK    % A=DMA-DF
053640                   CALL FAR RFTMTABLE; *1BANK         % REMOVE FROM TIMER TABLE
053642                FI; MIN CLPSELECTION
053643             OD
053644   NXTLP:    CSXXY+LPTBSIZE=:CSXXY
053647          OD; *2BANK

Line-by-line analysis:

Line Code Effect
2123-2125 IF X.LPCLENTRY><0 THEN CALL CLLPENTRY If CHLPS disabled this printer, clear ALL table entries (LDNT, ITB10, ITB11, timer)
2127-2131 IF CSXXY.LPSELECTION=3 THEN A:=0 ELSE ... X.S0 Get DMA datafield (Type 3 has none, so A:=0)
2132-2135 A=:D:=... CALL FAR UPDLPLOGNO Get I/O datafield, call UPDLPLOGNO to write into LDNT
2136-2146 IF CSXXY.LPSELECTION=1 THEN...ELSE... Type 1: clear ITB10 entry; Type 2/3: write DMA-DF into ITB10 at ident code position
2147-2153 DO WHILE CLPSELECTION<<=3 Loop types 1-3, remove timer table entries for unused types
flowchart TD
    START["XCHLPS: For each LPTA entry"]
    CHKCL{"LPCLENTRY\n= 0?"}
    CLENTRY["CLLPENTRY: line 2092\nClear LDNT, ITB10, ITB11\nClear timer table entries"]
    SKIP["GO NXTLP\nSkip to next printer"]
    GETDF["Get I/O DF and DMA DF\nfrom LPSELECTION offsets"]
    UPDLOG["UPDLPLOGNO: line 2047\nCNVRT lookup\nWrite DF into LDNT via STATX"]
    SETITB["Write DMA DF into\nITB10 at ident code position\nline 2140"]
    CLEANUP["Loop types 1 to 3\nRFTMTABLE for unused types\nline 2148"]
    NEXT["Next LPTA entry\n+16 words"]

    START --> CHKCL
    CHKCL -->|"Yes, LPCLENTRY=0"| GETDF
    CHKCL -->|"No, LPCLENTRY!=0"| CLENTRY
    CLENTRY --> SKIP --> NEXT
    GETDF --> UPDLOG --> SETITB --> CLEANUP --> NEXT

    classDef error fill:#F44336,stroke:#C62828,stroke-width:2px,color:#fff
    classDef success fill:#4CAF50,stroke:#2E7D32,stroke-width:2px,color:#fff
    classDef decision fill:#FFA726,stroke:#F57C00,stroke-width:2px,color:#000
    classDef process fill:#009688,stroke:#00695C,stroke-width:2px,color:#fff

    class CLENTRY,SKIP error
    class UPDLOG,SETITB success
    class CHKCL decision
    class START,GETDF,CLEANUP,NEXT process

How UPDLPLOGNO writes the LDNT (PH-P2-OPPSTART.NPL:2047-2062):

UPDLPLOGNO:
       AD=:CSVAD; X=:CXXX1                    % Save A=I/O-DF, D=DMA-DF
       IF X.LPLOGNO><0 THEN                    % LPLOGNO=5 for LP1
          A=:D SHZ -6; *2BANK                  % Extract group (5>>6 = 0)
          X:=CNVRT(A); A:=D/\77 SH 1+1; X+A   % CNVRT[0] + index*2 + 1 = slot address
          T:=LOGDBANK; A:=CSVAA; *STATX 10; STZTX  % Write: LOG.NO-OUT=I/O-DF, LOG.NO-IN=0
          *1BANK
       FI
       IF CXXX1.LPDMLOGNO><0 THEN              % LPDMLOGNO=1167 for LP1
          ...                                   % Similarly write DMA-DF into LDNT
       FI; EXIT

This writes the I/O datafield address (e.g., DILP1=107102₈ for Type 2) into the LDNT slot for logical device 5. After this, LOGPH(5) will find the datafield and return it instead of 0.

Phase 3: COPY-FILE Data Flow (when working)

flowchart TD
    CMD["@COPY FILE LINE PRINTER, source"]
    OPEN["Open peripheral file\nResolves to logical device 5"]
    OUTBT["OUTBT MON 2\nwith device 5"]
    LOGPH["LOGPH: LDNT lookup\nReturns datafield address"]
    BIOTR["BIOTR: Output buffer handler"]
    LPPUT["IOTRANS -> LPPUT\n7 bit ASCII translation"]
    STDEV["STDEV: Start device driver"]
    TLPRINT["TLPRINT: Level 11 transfer"]

    subgraph HWLOOP [Hardware IO Loop]
        WRCHAR["IOX 0431: Write character"]
        WRCTRL["IOX 0433: Write control word\nActivate + IE"]
        WAIT["Wait for Level 10\nreadyForTransfer interrupt"]
        IDENT["IDENT PL10\nIdent code 3 -> ITB10"]
    end

    CMD --> OPEN --> OUTBT --> LOGPH --> BIOTR --> LPPUT --> STDEV --> TLPRINT
    TLPRINT --> WRCHAR --> WRCTRL --> WAIT --> IDENT
    IDENT -->|"Next character"| WRCHAR

    classDef cmd fill:#009688,stroke:#00695C,stroke-width:2px,color:#fff
    classDef kernel fill:#3F51B5,stroke:#283593,stroke-width:2px,color:#fff
    classDef driver fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff
    classDef hw fill:#E91E63,stroke:#AD1457,stroke-width:2px,color:#fff

    class CMD,OPEN cmd
    class OUTBT,LOGPH,BIOTR,LPPUT kernel
    class STDEV,TLPRINT driver
    class WRCHAR,WRCTRL,WAIT,IDENT hw

Printer Types in SINTRAN

LPSELECTION Config Name NPL Driver Boot HW Test Ident (LP1) Ident (LP2)
0 Not configured -- Skipped -- --
1 DMA (Fujitsu) DMPR *IOXT 140230₈ 140231₈
2 Parallel (CDC/DP) DMLP *EXR ST 3₈ 23₈
3 Serial DLPR *IOXT 3₈ 23₈

Other print-capable devices in SINTRAN: - Terminal-based matrix printers (ND device 414-417, name "PRINTER") - Versatec printers/plotters (ND device 603-606, name "LINE-PRINTER-1") - Any device reachable via spooling (@APPEND-SPOOLING)

Emulator CDC 9380 implementation: Parallel = Type 2 (DMLP), ident code 3₈


Symbol Cross-Reference Table

Core Addresses (version-dependent)

Symbol K03 L07 M06 Description
0LPTA 033172₈ 036370₈ 036241₈ Line printer config table
0SPTA 033233₈ 036431₈ 036302₈ Spooling device table
CNVRT 004327₈ 004327₈ 004327₈ LDNT group conversion table
LOGDB 006545₈ 006620₈ 006604₈ Logical device bank
ITB10 126156₈ 153414₈ 155732₈ Ident table level 10
ITB11 126325₈ 077637₈ 077425₈ Ident table level 11
ITB12 126347₈ 153563₈ 156101₈ Ident table level 12

Printer Datafield Addresses (version-dependent)

Symbol K03 L07 M06 Description
DMLP1 052321₈ 107006₈ 106012₈ LP1 Type 2 (Parallel) datafield
DILP1 052415₈ 107102₈ 106106₈ LP1 Type 2 input datafield
DMPR1 052532₈ 107217₈ 106223₈ LP1 Type 1 (DMA) datafield
IDMP1 052563₈ 107250₈ 106255₈ LP1 Type 1 main datafield
DLPR 053203₈ 107670₈ 106676₈ LP1 Type 3 (Serial) datafield
DMLP2 052667₈ 107354₈ 106361₈ LP2 Type 2 datafield
DMPR2 053100₈ 107565₈ 106572₈ LP2 Type 1 datafield
IDMP2 053131₈ 107616₈ 106624₈ LP2 Type 1 main datafield
DLPR2 053236₈ 107723₈ 106731₈ LP2 Type 3 datafield

Fixed Offsets (same across all versions)

Symbol Value Description
LPTBS 000020₈ (16 words) LPTA entry size
0NLPS 000002₈ Number of line printers
HDEV 177775₈ (-3) HW device address offset in datafield
XHDEV 177774₈ (-4) Extended HW device offset
STDEV 000010₈ Start device routine offset
LPSEL 000000₈ LPSELECTION offset in LPTA entry

LPTA Entry Structure

Each LPTA entry is 16 words (020₈). The table starts at 0LPTA and contains 0NLPS (2) entries, terminated by -1 (177777₈).

block-beta
    columns 4

    block:header:4
        columns 4
        H0["Word +0\nLPSELECTION\n0=off 1=DMA\n2=Par 3=Ser"]
        H1["Word +1\nLPLOGNO\nLogical dev num"]
        H2["Word +2\nLPDMLOGNO\nDMA logical num"]
        H3["Word +3\n1LPIODF\nType 1 IO df"]
    end

    block:datafields:4
        columns 4
        D0["Word +4\n2LPIODF\nType 2 IO df"]
        D1["Word +5\n3LPIODF\nType 3 IO df"]
        D2["Word +6\n1LPDMDF\nType 1 DMA df"]
        D3["Word +7\n2LPDMDF\nType 2 DMA df"]
    end

    block:identcodes:4
        columns 4
        I0["Word +10\n3LPDMDF\nType 3 DMA df"]
        I1["Word +11\n1LPIDENT\nType 1 ident"]
        I2["Word +12\n2LPIDENT\nType 2 ident"]
        I3["Word +13\n3LPIDENT\nType 3 ident"]
    end

    block:footer:4
        columns 4
        F0["Word +14\nLPCLENTRY\n0=OK, !=0 off"]
        F1["Word +15\nreserved"]
        F2["Word +16\nreserved"]
        F3["Word +17\nreserved"]
    end

    style H0 fill:#F44336,stroke:#C62828,stroke-width:2px,color:#fff
    style D0 fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff
    style D3 fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff
    style I2 fill:#009688,stroke:#00695C,stroke-width:2px,color:#fff
    style F0 fill:#FFA726,stroke:#F57C00,stroke-width:2px,color:#000

Legend: LPSELECTION (red) is the root cause field. Datafield pointers (blue) must be non-zero for the selected type. Ident code (teal) maps to ITB10 interrupt dispatch. LPCLENTRY (amber) indicates boot detection result.

Offset Symbol Description
+0 LPSELECTION Printer type: 0=off, 1=DMA, 2=Parallel, 3=Serial
+1 LPLOGNO Main logical device number
+2 LPDMLOGNO DMA datafield logical number
+3 1LPIODF Type 1 (DMPR) I/O datafield address
+4 2LPIODF Type 2 (DMLP) I/O datafield address
+5 3LPIODF Type 3 (DLPR) I/O datafield address
+6 1LPDMDF Type 1 DMA datafield address
+7 2LPDMDF Type 2 DMA datafield address
+10₈ 3LPDMDF Type 3 DMA datafield address
+11₈ 1LPIDENT Type 1 ident code
+12₈ 2LPIDENT Type 2 ident code
+13₈ 3LPIDENT Type 3 ident code
+14₈ LPCLENTRY Clear flag: 0=OK, non-zero=disabled by boot
+15₈-17₈ (reserved) Padding to 16-word boundary

Source: PH-P2-CONFG-TAB.NPL -- actual DATA statement:

INTEGER ARRAY 0LPTA(0)
*"8LP1+8DLP1+8NLP1+8DVE1
"DATA( 0,    5, 1167, IDMP1, DILP1,  DLPR, DMPR1, DMLP1,  DLPR, 140230,  3,  3, 0,0,0,0) % LINE PRINTER 1.
*"8LP2+8DLP2+8NLP2+8DVE2
"DATA( 0,   15, 1175, IDMP2, DILP2, DLPR2, DMPR2, DMLP2, DLPR2, 140231, 23, 23, 0,0,0,0) % LINE PRINTER 2.
DATA( -1)                              % END OF TABLE TERMINATOR

The "8LP1 SINGEN macro controls the LPSELECTION value (word 0). All other fields (datafield addresses, ident codes) are filled in at compile time regardless of LPSELECTION.


Memory Inspection Checklist

Use these addresses for SINTRAN L07. For other versions, substitute from the Symbol Cross-Reference Table.

Diagnostic Decision Tree

flowchart TD
    START["Error 33: NO SUCH LOGICAL UNIT"]
    S1{"Step 1:\nLPSELECTION\nat 036370?"}
    FIX1["FIX: Patch LPSELECTION\nfrom 0 to 2"]
    S2{"Step 2:\nDatafield ptrs\nnon zero?"}
    FIX2["Disk image corruption\nRegenerate with SINGEN"]
    S3{"Step 3:\nHDEV = 0430?"}
    FIX3["Wrong HDEV value\nCheck datafield integrity"]
    S4{"Step 4:\nLPCLENTRY = 0\nafter boot?"}
    FIX4["HW test failed\nCheck EXR ST or try Type 3"]
    S5{"Step 5:\nLDNT entry\nnon zero?"}
    FIX5["XCHLPS did not run\nCheck boot sequence"]
    S6["Configuration OK\nCheck file system\nand peripheral file"]

    START --> S1
    S1 -->|"= 0"| FIX1
    S1 -->|"1, 2, or 3"| S2
    S2 -->|"Zero"| FIX2
    S2 -->|"Non zero"| S3
    S3 -->|"Wrong"| FIX3
    S3 -->|"= 0430"| S4
    S4 -->|"!= 0"| FIX4
    S4 -->|"= 0"| S5
    S5 -->|"= 0"| FIX5
    S5 -->|"Non zero"| S6

    classDef error fill:#F44336,stroke:#C62828,stroke-width:2px,color:#fff
    classDef success fill:#4CAF50,stroke:#2E7D32,stroke-width:2px,color:#fff
    classDef decision fill:#FFA726,stroke:#F57C00,stroke-width:2px,color:#000
    classDef start fill:#009688,stroke:#00695C,stroke-width:2px,color:#fff

    class FIX1,FIX2,FIX3,FIX4,FIX5 error
    class S6 success
    class S1,S2,S3,S4,S5 decision
    class START start

Step 1: Check LPSELECTION

Address: 036370₈ (word 0 of LPTA LP1 entry)

Dump 16 words at 036370:
  Word +0:  LPSELECTION  -- must be 1, 2, or 3 (NOT 0)
  Word +1:  LPLOGNO      -- should be 5 (logical device number)
  Word +14: LPCLENTRY    -- should be 0 after successful boot

If LPSELECTION = 0: This is the root cause. The printer was not configured in SINGEN. Proceed to Fix: Patching LPSELECTION.

Step 2: Check Datafield Pointers

Based on the LPSELECTION value, verify the datafield addresses are populated:

LPSELECTION I/O Datafield (offset) Expected Value (L07) DMA Datafield (offset) Expected Value (L07)
1 +3 (1LPIODF) IDMP1 = 107250₈ +6 (1LPDMDF) DMPR1 = 107217₈
2 +4 (2LPIODF) DILP1 = 107102₈ +7 (2LPDMDF) DMLP1 = 107006₈
3 +5 (3LPIODF) DLPR = 107670₈ +10 (3LPDMDF) (may be 0)

If either datafield address is 0: Boot code sets LPCLENTRY=1 at Fail Point B.

Step 3: Check HDEV in the Datafield

Read HDEV at offset -3 from the selected I/O datafield reference:

LPSELECTION Datafield HDEV address (L07) Expected HDEV value
1 IDMP1 = 107250₈ 107250 - 3 = 107245₈ 0430₈
2 DILP1 = 107102₈ 107102 - 3 = 107077₈ 0430₈
3 DLPR = 107670₈ 107670 - 3 = 107665₈ 0430₈

HDEV should be 0430₈ (LP1 IOX base address). The boot code computes the test address as HDEV+2 = 0432₈ (status register).

Step 4: Check LPCLENTRY After Boot

Address: 036370₈ + 014₈ = 036404₈

Read word at 036404:
  If 0:     Boot hardware test passed, printer active
  If non-0: Boot disabled the printer (hardware test failed)

Step 5: Check LDNT Entry for Device 5

1. Read CNVRT at 004327 -- get first word (CNVRT[0])
2. CNVRT[0] is a page number in LOGDBANK
3. Entry for device 5: offset = 5 * 2 + 1 = 013
4. If entry is 0 -> LDNT not populated -> confirms root cause

Step 6: Check Ident Code

Address (L07): Word +12₈ in LPTA = 036370₈ + 012₈ = 036402₈

For Type 2 (Parallel), ident code should be 3₈. This value is used to set up the ITB10 interrupt dispatch table entry during XCHLPS.


Fix: Patching LPSELECTION

What to Patch

Version Address Current Value New Value Meaning
K03 033172₈ 000000 000002 Enable Parallel/CDC printer
L07 036370₈ 000000 000002 Enable Parallel/CDC printer
M06 036241₈ 000000 000002 Enable Parallel/CDC printer

Value 2 = Parallel/CDC printer type (DMLP), which matches the emulator's CDC 9380 implementation.

Method: Patch the Disk Image

The LPTA table resides in the SINTRAN system area on disk. Patch word 0 of the table from 000000 to 000002 in the disk image file before booting.

Method: Patch Memory After Load

Alternatively, patch the word in memory after the SINTRAN image is loaded but before boot code runs CHLPS. This avoids modifying the disk image.

What Happens After Patching

With LPSELECTION=2, the CHLPS boot code will:

  1. See LPSELECTION=2 (valid, passes Fail Point A check)
  2. Load Type 2 datafield addresses from +4 (2LPIODF) and +7 (2LPDMDF)
  3. Verify datafields are non-zero (passes Fail Point B check)
  4. Read HDEV from the datafield, compute T = HDEV+2 = 0432₈
  5. Use *EXR ST (Type 2 path) to test printer presence
  6. If no IOX error: LPCLENTRY stays 0 (passes Fail Point C)
  7. XCHLPS sees LPCLENTRY=0, calls UPDLPLOGNO to populate LDNT entry for device 5
  8. @COPY-FILE LINE-PRINTER, file finds device 5 in LDNT and proceeds
flowchart LR
    PATCH["Patch\nLPSELECTION=2"]
    BOOT["Reboot\nSINTRAN"]
    CHLPS["CHLPS:\nValid type\nPass A"]
    DF["Datafields\nnon zero\nPass B"]
    EXR["EXR ST\nIOX 0432\nPrinter found\nPass C"]
    XCHLPS["XCHLPS:\nUPDLPLOGNO\nPopulate LDNT"]
    WORK["COPY FILE\nLINE PRINTER\nworks"]

    PATCH --> BOOT --> CHLPS --> DF --> EXR --> XCHLPS --> WORK

    classDef fix fill:#FFA726,stroke:#F57C00,stroke-width:2px,color:#000
    classDef pass fill:#4CAF50,stroke:#2E7D32,stroke-width:2px,color:#fff
    classDef hw fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff

    class PATCH,BOOT fix
    class CHLPS,DF,EXR pass
    class XCHLPS hw
    class WORK pass

Verification After Patching

After rebooting with LPSELECTION=2:

Check 1: LPCLENTRY

Read word at 036404₈ (L07). Must be 0 (hardware test passed).

Check 2: LDNT Entry

Follow the LDNT lookup from Step 5. The entry for device 5 should now contain a non-zero datafield address.

Check 3: Functional Test

@COPY-FILE LINE-PRINTER, test-file

Should produce output on the emulated printer without error 33.


Fallback: Debugging Hardware Detection

If LPCLENTRY becomes 1 after reboot (hardware test failed), the EXR ST instruction did not successfully reach the printer.

Add Emulator Logging

In devicemanager.c -- log printer IOX accesses:

if (address >= 0430 && address <= 0433) {
    printf("LP IOX %s addr=%06o val=%06o\n",
           is_write ? "WR" : "RD", address, value);
}

In cpu_instr.c around DoEXR -- log EXR executions:

printf("EXR: T=%06o executing=%06o\n", gT, exr_instr);

Try LPSELECTION=3 (Serial) Instead

If Type 2 (Parallel/CDC) fails because *EXR ST does not properly trigger an IOX, try LPSELECTION=3 (Serial). Type 3 uses *IOXT for hardware testing, which directly issues an IOX to the T register address. The ident codes are the same (3₈), so the rest of the pipeline should work identically.

Patch the same address with value 000003 instead of 000002.


EXR ST vs IOXT Analysis

The boot hardware test uses different instructions depending on printer type:

  • Type 2 (Parallel/CDC): *EXR ST -- execute instruction from T register
  • Type 1/3 (DMA/Serial): *IOXT -- IOX Test using T register as address

How EXR Works

void DoEXR(ushort instr) {
    sr = (instr >> 3) & 0x07;            // sr=6 for T register
    exr_instr = gReg->reg[CurrLEVEL][sr]; // Read T register value
    do_op(exr_instr, true);               // Execute as instruction
}

The value in T is executed as a machine instruction. If T contains an IOX-like value, it may or may not trigger an actual IOX depending on encoding.

Instruction Path Comparison

flowchart TD
    subgraph TYPE2 [Type 2: Parallel CDC]
        T2HDEV["HDEV + 2 -> T register"]
        T2EXR["EXR ST:\nExecute T as instruction"]
        T2DO["do_op: Decode T value"]
        T2IOX["If IOX encoded:\nndfunc_iox masks to 11 bits"]
        T2IO["io_op: Access IOX 0432"]
    end

    subgraph TYPE13 [Type 1 and 3: DMA Serial]
        T13HDEV["HDEV + 2 -> T register"]
        T13IOXT["IOXT:\nIOX Test using T as address"]
        T13IO["io_op: Access full T value"]
    end

    subgraph RESULT [Detection Result]
        FOUND["Printer found\nLPCLENTRY = 0"]
        NOTFOUND["IOX error\nLPCLENTRY = 1"]
    end

    T2HDEV --> T2EXR --> T2DO --> T2IOX --> T2IO
    T13HDEV --> T13IOXT --> T13IO
    T2IO --> FOUND
    T13IO --> FOUND
    T2IO --> NOTFOUND
    T13IO --> NOTFOUND

    classDef hw fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff
    classDef code fill:#E91E63,stroke:#AD1457,stroke-width:2px,color:#fff
    classDef success fill:#4CAF50,stroke:#2E7D32,stroke-width:2px,color:#fff
    classDef error fill:#F44336,stroke:#C62828,stroke-width:2px,color:#fff

    class T2HDEV,T13HDEV hw
    class T2EXR,T2DO,T2IOX,T13IOXT code
    class T2IO,T13IO hw
    class FOUND success
    class NOTFOUND error

What HDEV Contains

Scenario A: HDEV = plain IOX address (e.g., 0430₈) - T = 0430 + 2 = 0432₈ - IOXT path: io_op(0432) -> printer found - EXR ST path: executes 0432₈ as MRI -> no IOX error -> device "present" (but doesn't actually test HW)

Scenario B: HDEV = IOX instruction encoding (e.g., 0164430₈) - T = 0164430 + 2 = 0164432₈ - EXR ST path: do_op(0164432) -> ndfunc_iox() -> masks to 11 bits -> io_op(0432) -> printer found - IOXT path: io_op(0164432) = io_op(59674) -> NO device -> IOX ERROR

Most likely: HDEV contains a plain IOX address. Both paths should pass boot detection.


Data Flow: Working Print Path

When the printer is properly configured and LDNT is populated:

flowchart TD
    subgraph USER [User Command Layer]
        CMD["@COPY FILE LINE PRINTER, source"]
        OPEN["Open peripheral file\nResolves to logical device 5"]
    end

    subgraph KERNEL [Kernel Monitor Call Layer]
        OUTBT["OUTBT MON 2\ndevice 5"]
        LOGPH["LOGPH\nLDNT lookup via CNVRT\nReturns datafield addr"]
        BIOTR["BIOTR\nOutput buffer handler"]
    end

    subgraph DRIVER [Device Driver Layer]
        LPPUT["IOTRANS -> LPPUT\nCharacter translation\n7 bit ASCII"]
        STDEV["STDEV -> TLPRINT\nLevel 11 transfer"]
    end

    subgraph HARDWARE [Hardware IO Layer]
        WRCHAR["IOX 0431\nWrite character"]
        WRCTRL["IOX 0433\nWrite control + IE"]
        WAIT["Level 10 interrupt\nreadyForTransfer"]
        IDENT["IDENT PL10\nCode 3 -> ITB10\n-> datafield"]
    end

    CMD --> OPEN --> OUTBT --> LOGPH --> BIOTR --> LPPUT --> STDEV
    STDEV --> WRCHAR --> WRCTRL --> WAIT --> IDENT
    IDENT -->|"Next char"| WRCHAR

    classDef user fill:#009688,stroke:#00695C,stroke-width:2px,color:#fff
    classDef kernel fill:#3F51B5,stroke:#283593,stroke-width:2px,color:#fff
    classDef driver fill:#2196F3,stroke:#1565C0,stroke-width:2px,color:#fff
    classDef hw fill:#E91E63,stroke:#AD1457,stroke-width:2px,color:#fff

    class CMD,OPEN user
    class OUTBT,LOGPH,BIOTR kernel
    class LPPUT,STDEV driver
    class WRCHAR,WRCTRL,WAIT,IDENT hw

Layer Legend: - Teal = User command layer - Indigo = Kernel monitor call layer (LOGPH, BIOTR) - Blue = Device driver layer (LPPUT, TLPRINT) - Magenta = Hardware I/O layer (IOX registers, interrupts)


Key Source Files

File Content Status
PH-P2-CONFG-TAB.NPL LPTA table DATA statement, SINGEN macros Verified
PH-P2-OPPSTART.NPL:454-478 CHLPS boot detection (exact source above) Verified
PH-P2-OPPSTART.NPL:182-209 CLOGPH/XLOGPH - LOGPH simulation revealing algorithm Verified
PH-P2-OPPSTART.NPL:2039-2062 UPDLPLOGNO - writes DF into LDNT Verified
PH-P2-OPPSTART.NPL:2082-2116 CLLPENTRY - clears LDNT, ITB10, ITB11, timer Verified
PH-P2-OPPSTART.NPL:2118-2156 XCHLPS - LDNT population (exact source above) Verified
PH-P2-START-BASE.NPL:207-210 CCNVRT array (compile-time CNVRT copy) Verified
CC-P2-COMMON.NPL:50-105 CFLOGDV/9GTLOGDV - reverse LOGPH using CNVRT Verified
RP-P2-MONCALLS.NPL:112256 A:=D; CALL LOGPH - device 5 lookup Verified
RP-P2-MONCALLS.NPL:107240 IF A=0 GO ERR - error 33 trigger Verified
RP-P2-MONCALLS.NPL:3433 BIOTR output handler Call site verified
MP-P2-2.NPL:070540 LPPUT character translation Call site verified
IP-P2-1.NPL:044060 TLPRINT driver Call site verified
LOGPH (body) Actual LOGPH procedure Not in available source

Note: The body of LOGPH is not in any of the 45 available NPL source files. It is called via CALL LOGPH from 14+ files. The algorithm is known from the boot-time simulation CLOGPH/XLOGPH at PH-P2-OPPSTART.NPL:182.

NPL source location: ../NPL-SOURCE/NPL/ Symbol tables: ../NPL-SOURCE/SYMBOLS/



Parent: README.md -- Device Documentation Index Sibling: ../OS/README.md -- Operating System Documentation


Diagnostic guide based on analysis of SINTRAN III NPL source code and ND-100 emulator testing.