SINTRAN boot harness - "status" CS-load stall: architect hand-off (2026-07-18)

Full path: E:\Dev\Ronny\NDInsight\SINTRAN\ND500\SINTRAN-BOOT-HARNESS-CS-LOAD-STALL-HANDOFF-2026-07-18.md Evidence grade: OBSERVED (RetroCore emulator, real SINTRAN III L + nd-500-mon J04).

What was built (works)

Automated headless harness: E:\Dev\Repos\Ronny\RetroCore\Emulated.Tests\ND100\Nd100SintranNd500BootHarnessTests.cs ([Explicit], namespace Emulated.Tests.ND100). Boots SINTRAN III L from the BIGDISK0-L SMD image (raw block-0), auto-logs-in as SYSTEM, enters @nd-500, and drives status. Boot milestone PASSES (SINTRAN III RUNNING). Reproduces the interactive transcript faithfully up to N500: status -> > Loading Control Store.

Build recipe = the .ini exactly: direct new ND100Machine(MachineEnvironment.Test) (defaults already = ND100CX/MMS2/FPP48/2MB); CreateAndRegisterDevice FX0/SMD0/HD0/ND500-0/TERM5-7; console device 1 auto-created; mount FROM DATA (non-destructive scratchpad copy); LoadBootStrapperFromDevice("BD0"). Pump = machine.Run(pc,200_000) batches, poll console for markers (wall-clock timeout).

The stall (Bug B - the real blocker)

status stalls at > Loading Control Store; never reaches > Loading Swapper. The harness RunUntilAnyInstrumented traces STATUS + 3022.L12 + ND100.aggL12 + MICFU per pump. Timeline: - 0..~40 s: STATUS oscillates 0x0020 (locked) <-> 0x0000 (idle), MICFU=null throughout. - ~+40 s: STATUS = 0x0200 (= the CS-load doc's "stopped for verify" signature), then 0x0021 (int-en+locked) then oscillates 0x0020 <-> 0x0008 (finished) indefinitely. - Never MICRO-STARTs, never prints "Error in loading Control Store", never sends a 13B message.

So it is stuck in the CS readback/verify phase (ND500-CS-LOAD-TRACE-FINDINGS section 2), BEFORE MICRO-START and the 13B memory test (which is why MICFU stays null - the CS load is a register/TAG-level op, not a mailbox message).

KEY FACT: same code works in the app, stalls in the harness

Ronny confirmed (this session, live) that status completes in RetroCore.exe TODAY - flag dump and all (Loading Control Store -> Loading Swapper -> ZERO/CARRY/SIGN/FLAG/OVERFLOW). Same current working tree. So this is NOT a code regression and NOT a protocol gap - it is a harness-vs-app machine-driving difference in the CS verify phase.

Hypotheses RULED OUT (with evidence)

  1. Interrupt-delivery / level-12: PROVEN GOOD. Caught STATUS=0x0021 with 3022.L12=1 AND ND100.aggL12=1 together (ND100Machine.cs:929 feeds interruptBits&0x1000 to the CPU).
  2. CPU spin / master-clear re-park bug (Bug A, below): emulating its fix in the harness (repark-on-spin: park CpuND500 to WAIT when it spins at PC=0) did NOT resolve the stall.
  3. CS-load PROTOCOL code: the existing unit tests pass (LoadControlStore_FullCycle_..., LoadControlStore_VerifyReadback_ReturnsWrittenParts - 3/3, 373 ms).
  4. CPU model: stalls with BOTH the default SimulatedND500 (no run thread) AND a real CpuND500
    • run thread. Independent of the CPU.
  5. Code regression: app works with the same code.

What is LEFT (for the architect - needs app run-model + frozen NDBusND500IF internals)

The verify-phase readback (ND500-CS-LOAD-TRACE-FINDINGS section 2: DUEN/EDUTEN/CLKD5 -> LCON5:=$28 -> IOX READ offset 6) works in isolation (unit test) and in the app, but not under the harness's batched machine.Run(200_000) + Thread.Sleep(1) pump. Prime suspect: a driving/ timing/state difference between the app's run loop (BootDevice runs machine.Run(addr, -1) continuously) and the harness's batched pump - something that perturbs the DATA-OUT readback or the lock/test-mode state between the CLKD5 latch and the offset-6 read. This is the black-box limit; resolving it needs the app's exact run model.

Bug A (SEPARATE, real, worth fixing on its own)

CpuND500.Reset() (Emulated.HW\ND\CPU\ND500\CpuND500.ProcessControl.cs:42-43) does regs.Clear(); regs.stopMode = StopMode.NONE; - it clears PC to 0 and clears the stop state but does NOT re-park into the microcode IDLE (WAIT) state. So after any master-clear the CpuND500 run thread spins at PC=0 in garbage. NDBusND500IF calls nd500Cpu.Reset() from three master-clear sites (lines 1776, 1925 ND500ProgrammedClear, 1964 MasterClear). SINTRAN's boot master-clear (5MCST) hits these. Identical to the octobus OctobusND5000Station.HandleEmergency bug (octobus LLM, 2026-07-18) - same CpuND500.Reset(). AttachRealCpu documents/works around this at attach (sets stopMode=WAIT) but the reset paths do not. FIX: CpuND500.Reset() should set stopMode = StopMode.WAIT (re-park to idle), which fixes BOTH generations at once. This is NOT the cause of the status stall (Bug B) but is a real runaway-thread bug.

Reproduce

dotnet test Emulated.Tests\Emulated.Tests.csproj --filter "FullyQualifiedName~Nd100SintranNd500BootHarnessTests" Transcripts + trace: scratchpad sintran-boot-capture-{boot,fullflow}.txt. See also [[emulator-nd500-interface-wiring]], ND500-CS-LOAD-TRACE-FINDINGS-2026-07-16.md.