ND-210336 — ND-100 Symbolic Debugger

Status: IN-PROGRESS — install command and a real worked debugging session both sourced from real manuals; not yet run live in the emulator

Field Value
ND article number ND-210336 (also referenced as ND-10336 — the same base/21-prefixed-revision pattern seen throughout this catalog; the actual floppy in hand is labeled 210336F01)
Product name Symbolic Debugger for ND-100
Functional category Language Tools — Linkers / Loaders / Debuggers / Assemblers / Monitors
ND doc-category tag 60 General [curated]
CPU target ND-100
OS requirement unknown — no PD/PI sheet located
Related products ND-10335/ND-210166... — no: ND-10335 ND-500 Symbolic Debugger (companion product, same PI sheet family, see ../ND-10335/README.md) — same debugger for FORTRAN/COBOL/PLANC(/Pascal) programs, described together on ND-10335-C1-EN.md

Description

No PD or PI sheet naming this product specifically has been located — everything here is either from the mounted floppy or from the real System Supervisor manual's own worked example of installing it. The companion ND-500 product's PI sheet (ND-10335-C1-EN.md) describes the shared feature set both debuggers offer (breakpoints by line/routine/address/conditional, call-hierarchy inspection, DISPLAY/SET for variables, LOOK-AT commands with a built-in assembler/disassembler, symbolic references for modules compiled in DEBUG-MODE) — but does not describe the ND-100 version's own command syntax, which may differ from the ND-500 version documented in ND-10335B.

Versions

Version Subfolder Status Notes
F (rev 01) ND-210336F01 IN-PROGRESS — install command real/manual-sourced, usage not confirmed floppy 210336F01-XX-01D

Documentation

  • Program Description (PD-sheet): not located
  • Product Information (PI-sheet): not located under this article number — see the ND-500 companion's sheet, ND-10335-C1-EN.md, for the shared feature description
  • Manual(s): ND-60.158 Debugger User's Manual — ../../../Reference-Manuals/ND-60158-5-EN Symbolic Debugger - User Guide.md (this manual likely covers both the ND-100 and ND-500 debuggers — not yet cross-checked for ND-100-specific command differences)

Provenance

Floppy contents confirmed by downloading the image (MD5 6e073738400aa362f06fcbf827814808, from a floppy your friend imaged — logged in research/FLOPPY-BACKLOG-2026-08.md) and reading with ndtool. Install command found verbatim in the real ND-30.003.7 EN SINTRAN III System Supervisor manual's own worked example of setting up standard reentrant subsystems.


Parent: ../README.md (Software catalog)