10. Implementation Guide + C / C# Code Review

This file (a) tells you what to implement, and (b) reviews the two existing software models against the documentation, with special attention to the boot/autoload path (which was explicitly requested). Reviewed:

  • RetroCore C# — E:\Dev\Repos\Ronny\RetroCore\Emulated.HW\ND\CPU\NDBUS\NDBusFloppyDMA.cs (read in full for this review).
  • nd100x C — /home/ronny/repos/nd100x/src/devices/floppy/deviceFloppyDMA.c + .h (read in full for this review).
  • Cross-reference: the handoff E:\Dev\Repos\Ronny\nd-120\Verilog\docs\HANDOFF-nd100x-floppy-dma-manual-fixes.md.

Verdicts use: manual = ND-11.021.1, firmware = the 34300G.bin ROM (authoritative for actual behaviour).


10.1 The boot / autoload path — what actually happens today

STATUS UPDATE (RetroCore C#): implemented. NDBusFloppyDMA.ExecuteAutoload() now performs a real autoload — see §10.1a below. The stub description that follows is retained for the nd100x C model (still a stub) and as the historical baseline.

Original short answer: nothing real. In both emulators ExecuteAutoload was a stub. Neither read the floppy, located the BPUN bootstrap, or DMA'd an image into ND-100 memory. Compare against the real firmware flow in 04-boot-and-autoload.md §4.3.

nd100x C (ExecuteAutoload, line 227):

/* TODO: Implement */
/* TODO: DMA TRANSFER PROM bootcode to ND-100 Memory */
Device_QueueIODelay(self, IODELAY_FLOPPY, (IODelayedCallback)AutoLoadEnd, 0, self->interruptLevel);
It transfers no data, but it does queue AutoLoadEnd, which sets RFT and raises the completion interrupt. So the guest doesn't hang — it just gets a "done" with an empty result.

RetroCore C# (ExecuteAutoload, line 506):

Log($"Executing Autoload");
/* TODO: DMA TRANSFER PROM bootcode to ND-100 Memory */
//active = true;
//QueueIODelay(10, AutoLoadEnd, 0, InterruptLevel);
The completion call is commented out. So AutoLoadEnd never runs, RFT is never re-set, and no interrupt fires — a guest that actually issued control-word autoload and waited for RFT would hang. This is strictly worse than nd100x. AutoLoadEnd (line 1028) is therefore dead code.

Why booting still works today: the machine setup loads the BPUN bootstrap into ND-100 memory by a different route and calls InitializeForBoot(unit) (C#, line 402), which just sets selectedDrive and rsr1 = ReadyForTransfer. That is an out-of-band shortcut, not the controller's real autoload. Real "press LOAD → boot from floppy" through the controller is not emulated in either model.

10.1a How the RetroCore C# autoload is now implemented

NDBusFloppyDMA.ExecuteAutoload() (control-word bit 2) now: 1. Picks the boot unit (the selected drive, or 0 — the firmware selects/restores drive 0). 2. Marks the controller busy (clears RFT). 3. Calls a host delegate OnAutoloadRequest(unit). The controller can't reference the BPUN parser directly (it lives in Emulated.Utilities, which references Emulated.HW — referencing it back is circular), so the machine services the request: ND100Machine.LoadFloppyBpunIntoMemory(controllerId, unit) reads the first track, parses the BPUN image (reusing the existing BPUN class), and DMAs the code into ND-100 memory at the BPUN load address. This is the same helper the ND-100 LOAD path (LoadBootStrapperFromFloppy) now uses, so the two boot routes share one implementation. 4. On success: errorCode = TRANSFER_OK, select the unit, complete with RFT (+ interrupt) via the queued AutoLoadEnd. The ND-100 LOAD microcode transfers control — the controller does not jump, matching the firmware. 5. On failure (no media / bad BPUN / no handler): errorCode = NO_BOOTSTRAP_FOUND_ON_DISKETTE (oct 50), and AutoLoadEnd reflects it in the hardware status word (bit 4 OR-of-errors + bit 7 hard error).

Covered by tests in Emulated.Tests.ND100\ControllerFloppyDMA\TestNDBusFloppyDMA.cs (Autoload_Success_*, Autoload_NoHandler_ReportsHardError, Autoload_HandlerReturnsFailure_ReportsHardError). Divergence #9 is resolved for C#; nd100x C remains a stub.

What a correct autoload needs (from firmware, §4.3/§4.6): 1. On control-word bit 2 (State I) — and, given the §4.2 ambiguity, also accept the bit-8 fetch-and-execute path the ND-100 microcode may use. 2. RESTORE to track 0, read the first ~2 KB into a buffer. 3. Locate the BPUN signature '!' (0x21); require a CR (0x0D) within the preceding 128 bytes and an octal digit '0'..'7' just before it → else error 50₈. 4. (Optional) reject an out-of-date monitor → error 51₈. 5. Parse the BPUN header → ND-100 load address + word count; DMA the image there. 6. Complete with an interrupt. Do not start execution — the ND-100 LOAD microcode does.

Because the exact BPUN header arithmetic is not fully resolved (§4.6 [COULD NOT DETERMINE]), a functional emulator should parse the BPUN format from its own spec, and can validate against the working image …\N100-FLOPPY-3112\ND Code\DEPOSIT 0 77400.txt.


10.2 Divergence table (both models vs. the documentation)

Winner = what the firmware/manual say is correct.

# Topic nd100x C RetroCore C# Firmware/manual says Who's right
1 Error-code bit position errorCode:7 at bit 8 (.h ~L318) errorCode << 9 (bits 9–14) (code&0x3F)<<1 in high byte → bits 9–14 [FW @06b4] C#
2 IOX +4 read returns status2.raw (never populated) returns same as +2 +4 == +2 hardware status word (§3.1 Note 1) C#
3 Two-status-word split conflated (dualDensity into CB+6) conflated (dualDensity bit 15 into CB+6) HW word (IOX) has b15 dual-density, no code; Status Word 1 (CB+6) has code b9–14, b15 clear neither
4 Write-protect on WRITE enforced → WRITE_PROTECTED, abort floppyIsWriteProtected read but unused → write succeeds oct 16 real, abort before write [FW @0e84/@1ea2] nd100x
5 Bit 4 "OR of errors" computed = hardError\|deleted\|retry never set (InclusiveOrReg2 unused) set whenever code≠0 (or DMA error) [FW @06bc] nd100x, but see 5b
5b Bit 4 formula detail misses plain errorCode≠0 case (e.g. CRC alone) — firmware sets b4 on any non-zero code neither fully
6 Error-code enum completeness has WRITE_PROTECTED, RAM_ERROR, DRIVE_NOT_READY missing WRITE_PROTECTED(14), FORMAT_NOT_FOUND(8=oct10), RAM_ERROR(oct71) full octal table (§3.9) nd100x
7 Backend read/write fail code DRIVE_NOT_READY (oct 20) CRC_ERROR (5) drive/backend failure ≈ not-ready; CRC = bad media (§3.10) nd100x
8 IDENTIFY / unknown cmd completion IDENTIFY + default both queue ReadEnd → complete IdentifyFloppy has no case → default: break → no ReadEnd → RFT never set → hang every command must complete + interrupt [FW @03e3] nd100x
9 Autoload stub, but completes (no data) stub, completion commented out → hang full bootstrap load (§4.3) neither
10 Dual-density bit 15 location on CB+6 (wrong) + IOX on CB+6 (wrong) + IOX IOX hardware word only; clear in CB+6 (§3.4/§3.7) neither

10.3 RetroCore C# — specific findings

STATUS: divergences 1-10 now FIXED. - C#: write-protect enforced (WRITE_PROTECTED=14); bit-4 OR set when errorCode!=0; IDENTIFY/default complete; enum gained WRITE_PROTECTED/FORMAT_NOT_FOUND/RAM_ERROR; autoload + error-image done; two-status-word split done — IOX +2/+4 → CalculateHardwareStatusWord (bit-15 dual-density, no code), CB+6 → CalculateStatusWord1 (code bits 9-14, bit-15 clear). - nd100x C: error code moved to bits 9-14 (.h bitfield, FIX 1); IOX +4 → hardware word (FIX 2); split into CalculateHardwareStatusWord / CalculateStatusWord1 (FIX 3); bit-4 formula includes errorCode!=0 (5b). Builds clean. - Tests: TestNDBusFloppyDMA.cs (WriteData_OnWriteProtectedFloppy_* asserts the split, IdentifyFloppy_Completes_*). C# 251/0.

Remaining follow-ups (not blockers): Status Word 2 §3.5.2.2 bit remap, C real BPUN autoload, the 7 PIO tasks.

Ordered by severity.

  1. Write-protect not enforced (divergence 4). NDBusFloppyDMA.cs:736 computes floppyIsWriteProtected = IsDeviceReadOnly(unit) and never reads it. WriteData (:818) writes unconditionally. Fix: before the write, if floppyIsWriteProtected, set errorCode = WRITE_PROTECTED (add = 14 to the enum), set RFT, write the status block, interrupt, and return — do not write. (Match the nd100x WRITE block at C :445.)

  2. IDENTIFY / unknown command hangs (divergence 8). IdentifyFloppy = 0x38 has no case in the switch (:780), so it hits default: break (:957). The post-switch block writes Status 1/2 once but never queues ReadEnd, so ReadyForTransfer (cleared at :769) is never restored and no interrupt fires. Fix: give default (and Identify) a QueueIODelay(IODELAY_FLOPPY, ReadEnd, unit, InterruptLevel) like every other case.

  3. Bit 4 "OR of errors" never set (divergence 5). InclusiveOrReg2 is declared (:278) but never assigned. Fix: in the status-word builder, set bit 4 when errorCode != TRANSFER_OK (the firmware truth), not the nd100x hardError|deleted|retry formula.

  4. Two status words conflated (divergence 3/10). CalculateStatusWithDualDensity() (:437) ORs in DualDensityController (bit 15) and is used for both the IOX read (:425) and the CB+6 memory writeback (:727,796,844,968,1019). Per §3.4, bit 15 in Status Word 1 (CB+6) must be clear. Fix: split into two builders — a hardware- status-word builder (bit 15 set, no error code) for IOX +2/+4, and a Status-Word-1 builder (error code at bits 9–14, bit 15 clear) for the CB+6 writeback.

  5. Autoload is a no-op that hangs (divergence 9). See §10.1. Fix: implement the §4.3 flow, or at minimum re-enable a completion so the guest doesn't hang.

  6. Error-code enum incomplete (divergence 6). Add WRITE_PROTECTED = 14, FORMAT_NOT_FOUND = 8, RAM_ERROR = 0x39 (oct 71 = 57 dec), etc. Note values are decimal placed at bits 9–14, so the SINTRAN driver reads them back as the octal figure (e.g. value 14 → bits 9–14 = 14 dec = 016 octal = "Write protected", matching §3.9).

  7. Minor correctness bugs:

    • :744 case 2: bytes_pr_sector = 123; — typo, must be 128 (128 B/sector). Also at C# :882 the ReadFormat comment repeats "123".
    • :638 sectors_pr_track = 18; with the comment noting DD is 8 sectors/track — the geometry (:748-749) mixes sectors_pr_track and sectors_pr_track-1 and is not the manual geometry (8 sectors × 77 tracks). This "works" for the current boot path but is not format-correct; derive geometry from the selected format (§5).
    • Backend read/write failure uses CRC_ERROR (:792,840); prefer DRIVE_NOT_READY (divergence 7).

Correct in C# (keep): error code << 9 (divergence 1 ✓), IOX +4 == +2 (divergence 2 ✓), Reset() leaving RFT clear (matches firmware; prevents a spurious level-11 interrupt).

10.4 nd100x C — specific findings

  1. Error code at bit 8, must be bit 9 (divergence 1). deviceFloppyDMA.h errorCode : 7 sits at bits 8–14. Fix (handoff FIX 1):

    uint16_t hardError : 1;   // Bit 7
    uint16_t notUsed8  : 1;   // Bit 8
    uint16_t errorCode : 6;   // Bits 9-14
    uint16_t notUsed15 : 1;   // Bit 15
    

  2. IOX +4 returns the wrong register (divergence 2). FloppyDMA_Read :127 returns data->status2.raw (which is never populated). Fix (handoff FIX 2): return the hardware status word, same as +2.

  3. Two status words conflated (divergence 3/10). CalculateStatusRegister1 sets dualDensity = 1 and is used for both IOX +2 (:124) and the CB+6 writeback (:632). Fix (handoff FIX 3): a CalculateHardwareStatusWord() (b15 set, no code) for IOX, and a CalculateStatusWord1() (code b9–14, b15 clear) for CB+6.

  4. Bit 4 formula incomplete (divergence 5b). inclusiveOrBits = hardError | deletedRecord | retryOnController (:104) misses the common case where only errorCode is set (e.g. CRC, write-protect) with none of those three bits. Firmware sets bit 4 on any non-zero code. Fix: || (errorCode != 0).

Correct in nd100x (keep): write-protect enforcement (:449), command completion for IDENTIFY/default (:583/:588), the full error-code enum, DRIVE_NOT_READY for backend failures.

  1. C# write-protect + error enum (divergence 4, 6) — small, high value, unblocks correct error reporting. Add WRITE_PROTECTED = 14.
  2. C# IDENTIFY/default completion (divergence 8) — prevents a real hang.
  3. C# bit-4 OR-of-errors (divergence 5) — trivial once the status builder is touched.
  4. Both: split the two status words (divergence 3/10) — the structural fix; do C# and C together so they stay bit-identical, and validate against the corrected Verilog testbench (nd-120/Verilog/…/nd_floppy_dma_tb.v, TB_RESULT: PASS).
  5. nd100x error-code bit position + IOX +4 (divergence 1, 2) — per handoff FIX 1/2.
  6. Autoload (divergence 9) — the largest piece; implement the §4.3 firmware flow if real controller-driven boot is wanted. Until then, at least re-enable the C# completion so it cannot hang.

10.6 Validation

  • There is no standalone unit test for the nd100x floppy DMA; validate by booting SINTRAN / running the BFDIS driver and confirming it reads the error code from CB+6 bits 9–14 and detects the DMA controller via IOX +2 bit 15. [handoff §How to validate]
  • RetroCore has floppy DMA tests under E:\Dev\Repos\Ronny\RetroCore\Emulated.Tests.ND100\ControllerFloppyDMA\TestNDBusFloppyDMA.cs — extend these for write-protect (expect error 016₈ at CB+6 bits 9–14), IDENTIFY completion (expect RFT + interrupt), and the bit-4 OR flag.
  • The corrected Verilog core + its passing testbench are the bit-exact oracle for the two-status-word split.