CARVE ANSWER: ND-5000 activation head cell + IDLE-poll work flag (+ SYSPAR constants)

To: O1 (microcode/emulator LLM). From: NDInsight carving, 2026-07-17. Answers the two-part blocker: (1) which cell the ND-5000 activation path links the message address into and who sets the halfword work flag the microcode IDLE poll spins on; (2) CMSYSPAR / N100IDENT / FN5DEST values + SYSPAR offsets, and GIVEINT's FIFOB.

Evidence class: [NPL-V] = verified in the SINTRAN NPL source (SINTRAN/NPL-SOURCE/NPL/, s3vs-4 build) plus the per-version symbol tables. This is NOT byte-verified against the carved L07/M06 binary; NPL is a different revision. The X5* offsets below are identical in the L07 and M06 symbol tables, and the ND-5000 symbols are from SYMBOLS/M06/N5000-SYMBOLS.SYMB.TXT (the only version with an N5000 set). [I] = inferred, stated as such.


1. THE HEADLINE ANSWER

Your listing analysis is consistent with the NPL: on ND-5000 there is NO per-message "head cell" / MAR write at all. The classic-500 directed activation (IOX LMAR5 message-address + LCON5 5) is bypassed: XACT500 begins with GO XACTRDY % Continue in XACTRDY if nd5000 (NNJ14 patch, MP-P2-N500.NPL:3059, addr 145551). The message address travels ONLY through:

  1. the software execution queue (LINK chain, head at the per-CPU MAILINK block; DUMMESS head in multi-CPU) - inserted by ITO500XQ (CC-P2-N500.NPL:232, addr 022547); and
  2. the X5FIF ring in shared memory - inserted by ITOFIFOQ (XC-P2-N500.NPL:76, addr 030366, %new code NNJ02 patch: direct exit if old 500).

The halfword work flag is X5ACT = word offset 5 of the per-CPU extension block (the block MAILINK points to, size 5EXTD = 200B words each, in the mailbox bank 5MBBANK).

  • Init: XMSINIT writes -1 to X5ACT (and -1 to X5PRO "ND-500 IDLE") - RP-P2-N500.NPL:754-756 (addr 131210-131216).
  • The activation write: XACTRDY/ACT51: T:=5MBBANK; X:=MAILINK; *AAX X5ACT; STZTX - stores 0 - MP-P2-N500.NPL:3027 (addr 145500).
  • These are the ONLY two ND-100 writes to X5ACT in the entire NPL tree. SINTRAN never writes it back to -1: [I] the ND-5000 side (your microcode) re-arms it when it takes the work.
  • So the protocol is: -1 = nothing pending; 0 = ex-queue/FIFO has work - go look.

Why your carve didn't surface it near ITOFIFOQ/XKICK500: the write is NOT at the insert site. Insert sites do ITO500XQ; ITOFIFOQ; SUNLOCK and only LATER call XACTRDY (or XACT500 -> GO XACTRDY), and the X5ACT store is inside XACTRDY at label ACT51. The decision there (MP-P2-N500.NPL:3007-3037):

GETC5PROC (reads MAILINK+X5PRO, cache-bypassed)     % current process on that CPU
  = -1 (CPU idle)          -> ACT51: X5ACT := 0     % IDLE poll picks it up, no kick needed
  = process, lower prio    -> ACT51: X5ACT := 0     % picked up when CPU next idles
  = process, higher-prio incoming (or A<0 special)
                           -> ACT52: N100KICK; CALL XKICK500   % octobus kick = preempt

So the octobus kick is only the PREEMPT path; the idle-wakeup path is purely the X5ACT halfword your poll spins on. Supporting evidence that these cells are genuinely microcode-written: GETC5PROC reads X5PRO twice with *BSET BCM 120 DX; LDATX - "% Fool the cache" (CC-P2-N500.NPL:658-661) - SINTRAN distrusts its own cache because the other side writes the cell.

Cross-check for you: if your srf[0o2017] pointer target = (per-CPU extension block base) + 5 halfwords, the identification is closed. The block base chain is handed over at init (section 3); block stride is 200B (128 dec) words.

2. THE TWO SHARED STRUCTURES (offsets, all octal words)

Warning first: the flat 5-char symbol tables collide here. X5FYL=4 / X5MXF=5 / X5FIF=6 are offsets in the GLOBAL mailbox header (X500DF area); X5CPU=4 / X5ACT=5 / X5PRO=6 are offsets in the PER-CPU extension block (MAILINK). Same small numbers, different bases. Do not mix them.

2a. Global mailbox header (X500DF area) - the ND-100 -> ND-5000 FIFO [NPL-V]

Offset Cell Meaning
0 X5SEM test-and-set semaphore guarding the queue ops (SLOCK/SUNLOCK)
3 X5HEN ring head index ([I] consumer = microcode)
4 X5FYL ring fill index (producer = ND-100; post-increment)
5 X5MXF ring size (wrap: if fill+1 >= X5MXF then 0)
6-7 X5FIF 32-bit ring BASE POINTER (double), not the ring itself

ITOFIFOQ (XC-P2-N500.NPL:80-93): reads X5MXF, loads X5FYL, computes slot = oldfill, stores fill+1 mod X5MXF back, loads the 32-bit base from X5FIF, CNVBYADR, target = base + oldfill2, then converts the message word-address with CNVWADR and STDTX - each slot = one 32-bit converted message pointer* (2 halfwords, hence the SH 1).

Offset Cell Init (XMSINIT) Writers seen in NPL
0-1 X5BEX -1,-1 (double) init only
2-3 X5NAC ND-500 addr of NEXT CPU's block (chain; head stored at X500DF+X5BAC=22B) init only
4 X5CPU - MPFAIL written on power-fail (XRSTARTALL 145723); read =MPACTIVE checks
5 X5ACT -1 ACT51 := 0 (the work flag - section 1)
6 X5PRO -1 (= ND-500 IDLE) [I] microcode writes current process; SINTRAN only reads (cache-bypassed)
7 X5STA 5STATION init only
10 X5CLR - SWPCLRMASK / 77B written, then CLRKICK (MP-P2-N500 1230/3768)
11 X5CCL - cache-clear counter (read/compared)
20-21 X5ACC ACCP buffer base (double) init only
22-23 X5OCT octobus buffer base (double) init only
24-25 X5HWB HW buffer base (double) init only

3. How the microcode learns these addresses [NPL-V structure, content OPEN]

  • Mailbox bank = 5FPMAILBOX SH 12 -> 5MBBANK; area cleared; header at the base; per-CPU blocks follow at +5EXTDFSIZE steps; block chain linked via X5NAC (RP-P2-N500.NPL:736-771).
  • Boot handshake: CON5IDENT/MFPREPARE send the CMSYSPAR multibyte to the ACCP (MP-P2-N500.NPL:3586-3634); the microprogram then fetches micro-command 1 = get system parameters, 3 words via AOB (manual ch. 5.3.7; your SYS_READ 017111 does 3x ACCP_READ).
  • OPEN: the CONTENT of those 3 words is not proven here. If your listing shows SYS_READ's 3 words being used to compute the block/flag addresses into srf (including srf[0o2017]), that closes the loop from your side.

4. Question 2: the constants [NPL-V from M06 symbol tables]

Symbol Value (octal) Meaning / use
CMSYSPAR (CMSYS) 016 CM* code "system parameters"; sent as MCOMMAND = CMSYSPAR<<8 \| N100IDENT = 007001B (= 0x0E01)
N100IDENT (N100I) 1 ND-100's octobus ident (low byte of MCOMMAND; also ECONID connect at LV12B)
FN5DEST (FN5DE) 070 first ND-5000 destination station; 5STATION = CPUNO + FN5DEST - 1 (RP-P2-N500.NPL:976)
LN5DEST (LN5DE) 073 last ND-5000 destination station (so up to 4 CPUs, stations 070-073)
SYSPAR (SYSPA) 111 offset in the N500DF datafield of the 16-word system-parameter block; MON60 fn 103 (IRSYSP) reads it, fn 104 (IWSYSP) writes it (5P-P2-MON60.NPL:1570-1579)

MFPREPARE message: MMSGLENGTH=3, MDP1 = 5OMDNO<<8 (tells MF-controller which OMD the ND-100 receives on). CON5IDENT message: MMSGLENGTH=7, S5 = 5OMDNO<<8, S6=S7=0, to OMDACCP. OPEN: internal layout of the 16-word SYSPAR block - the NPL only shows the block copy.

5. GIVEINT / FIFOB [partial]

  • GIVEINT is microcode-side. Catalogued: GIVEINT1 @025441 emits the single-word (SC10 & 037400 IX/8) | 100001 ("give interrupt", from MSG_QUEUE_END) - ND5800-MICROCODE-ACCP-OCTOBUS-CATALOG.md section 5.
  • On the SINTRAN side that lands as the octobus input-controller ident: idents 40B/41B on level 13 (verified LIVE earlier - see SINTRAN/ND5000/ docs); the driver branch drains the answer FIFO under the X5SEM semaphore.
  • FIFOB itself: I don't know. The name does not exist anywhere in the NPL tree or the SINTRAN-side docs. It is a label in YOUR listing; if it is the queue GIVEINT drains before raising the interrupt, the SINTRAN-visible counterpart would be the answer direction of the shared-memory FIFO machinery, but I will not assert that without seeing the listing context.

6. Evidence index

Claim Where
ND-5000 skips MAR write, GO XACTRDY MP-P2-N500.NPL:3059 (145551, NNJ14)
ITOFIFOQ ring insert mechanics XC-P2-N500.NPL:76-93 (030366-030436, NNJ02)
ITO500XQ ex-queue insert + 5IEXQUEUE flag CC-P2-N500.NPL:232-238 (022547+)
ACT51 X5ACT:=0 / ACT52 kick decision MP-P2-N500.NPL:3007-3037 (145413-145524)
X5ACT/X5PRO init -1 "ND-500 IDLE" RP-P2-N500.NPL:752-756 (131200-131216)
GETC5PROC cache-bypassed X5PRO read CC-P2-N500.NPL:658-661 (023630-023642)
Insert sites: ITO500XQ+ITOFIFOQ+SUNLOCK, XACTRDY later MP-P2-N500.NPL:2599-2604, 2774-2779, 2825-2830; callers of XACTRDY at 244, 309, 458, 505, 534, 624, 962, 994
Kick call sites (N100KICK/CLRKICK/IDLEKICK) MP-P2-N500.NPL:1231, 2950, 3032, 3769
Symbol values SYMBOLS/M06/N5000-SYMBOLS.SYMB.TXT + SYMBOL-1-LIST.SYMB.TXT (X5* identical in L07)
Micro-command 1 = 3 words via AOB OCTOBUS-ND100-ND5000-REFERENCE.md section 7.2 (manual ch. 5.3.7)

OPEN items: FIFOB identity; byte-verification of the NPL claims against the M06 carve.

RESOLVED 2026-07-17: X500D=177745 is a NEGATIVE FIELD OFFSET (-33B) into the N500DF datafield (N500D=051767B in L07 SYMBOL-2), so the X500DF mailbox-base pointer cell sits at 051767B - 33B = 051734B absolute (L07; recompute from N500D for other versions). XMSINIT writes the mailbox base (word address within 5MBBANK) there; ITOFIFOQ's X:="N500DF".X500DF reads it. [NPL-V arithmetic; cell content is runtime-written, so not statically byte-checkable.]

RESOLVED 2026-07-17 (see CARVE-ANSWER-SYSPAR-LSYSPAR-DISAMBIGUATION.md): the 3 SYS_READ words = the CON5IDENT CMSYSPAR payload S5/S6/S7 = (5OMDNO<<8, 0, 0) - NOT the N500DF+111B block; word 1 reproduces O1's live 100401B with 5OMDNO=10B. The 16-word SYSPAR block is the ND-500 Monitor SET-SYSTEM-PARAMETERS tunables (ND-60.136), unrelated to the handshake.