ND-5000 Hardware Maintenance Manual — Emulation-Relevant Analysis¶
Source: E:\Dev\Ronny\NDInsight\Reference-Manuals\500\ND-05.017.01 EN ND-5000 HARDWARE MAINTENANCE.md
(ND-05.017.01, OCR'd 2026-07-18; ~12250 lines). Grade [DOC-manual] unless noted; where
it CONFIRMS our independent carve I mark [V-confirms].
This is an extraction of the parts that matter for the ND-100↔ND-5000 emulation (octobus, mailbox, CPU model/backplane, init/CS-load). It is NOT a full read of the manual; §6 is a chapter map pointing to what remains for deeper dives.
1. Octobus station-number map (ch 3.1) [V-confirms + extends carve]¶
"A maximum of 62 stations (processors) can be connected to one bus… all devices are given a unique station number. The octobus is not visible above the low-level OS."
| Station no. (octal) | Device |
|---|---|
| 1 | ND-100 |
| 2–7 | MFB controllers |
| 10–13 | SCSI controllers (disk) |
| 14–15 | Matra VME |
| 16–17 | Multifunction communication |
| 20 | Hyperchannel |
| 21–23 | FDDI (Fibermet) |
| 24–27 | FPS-5000 |
| 30–33 | Graphic controller |
| 34–67 | Free for expansion |
| 70–76 | ND-5000 |
- CONFIRMS + EXTENDS our carve: hardware reserves 70–76 for ND-5000 CPUs; SINTRAN's
carved
FN5DEST=070B / LN5DEST=073B(4 CPUs) is the SOFTWARE subset it actually addresses (CPU 1–4 = 70B/71B/72B/73B, ch 2.1.5). ND-100 = station 1. - MASTER arbitration (ch 3.1): lowest station number becomes MASTER → ND-100 (station 1) is the natural bus master. Bus lines XRREQ/XCLK/XDAT/XRFO; MASTER pulses XRFO every 15 µs; collision = give-up-and-retry with priority increment (the "Lost Access Counter").
2. Octobus frame + message format (ch 3.2 / 3.3) [V-confirms carve]¶
30-bit frame (+Start/Stop): Priority | Destination | C | B | Source | Information |
Parity | Ack. The 16-bit FIFO/wire form the driver sees:
| 15 | 14 13 12 11 10 09 | 08 07 06 05 04 03 02 01 00 |
| C | B Dest/Source | INFORMATION |
00=timeout(15 retries), 01=OK, 10=dest busy(255 retries), 11=parity
error / ambiguous.
Information-byte sub-decode (CONFIRMS our OCB/E-K-M-S model):
E K M S | meaning
1 . . . | Emergency (power-fail, master-clear, reset AQP) — hardware/driver decoded
0 1 . . | Kick (wake a handler; activate/terminate ND-5000)
0 0 0 0 | Ident (interrupt ND-100 from ND-5000)
0 0 1 1 | Start of multibyte (SOMB)
0 0 1 0 | End of multibyte (EOMB)
0 0 . . | (C=0) data byte — part of multibyte
Four message streams (ch 3.3) — confirms our whole model:
1. IDENT → IDENT ENTRIES; "immediately activates a process with correct working set…
used to interrupt the ND-100 from the ND-5000 CPU." ← the answer-back / GIVEINT path.
2. KICK → HANDLER ENTRIES; "Kick number 1 starts scanning the execution queue" in
the ND-5000 CPU. ← CONFIRMS carved N100KICK=1 = ACTIVATE (execution-queue walk).
3. MULTIBYTE → OMD; "CMD number 3 handled by the Access Processor (ACP/ACCP)";
used for control-store load + AQP commands. ← CONFIRMS OMD/CS-load path.
4. EMERGENCY → hardware/driver decoded.
3. THE BACKPLANE-ID ANSWER — who reports the CPU's id over octobus (ch 3.4 + 2.1.5/2.1.6)¶
Question: with multiple CPUs, who reports the correct backplane/station id back to the ND-100 over octobus?
Answer: each ND-5000 CPU reports its OWN id, independently — there is no central arbiter. Mechanism, layer by layer [DOC + V-confirms]:
- Per-slot MF-backplane EEPROM holds
STATION NO(ch 2.1.6;LIST-CONFIGURATIONshowsSTATION NO: 0000070Bfor a slot, alongside CPU MODEL / POWER FAIL DESTINATION / BROADCAST TYPE / SPEED / MASTER CONTROL REG). It is set per slot with the updating tool (SET-CPU-MODEL+CONFIGURATE-SLOT); a 4-CPU ND-5900 is configured CPU 1→70B, 2→71B, 3→72B, 4→73B (ch 2.1.5). Clearing/losing the EEPROM loses it (ch 2.1.6). - The CPU's LOCAL octobus interface is INITIALIZED with that Station no. (ch 3.4): the octobus hardware on the ND-5000 CPU takes initiation parameters = {BADAP reg., Speed, Station no.}. So each CPU's octobus transmitter is armed with its own station number at init (loaded from the slot's backplane config; exact loader = MF-bus controller / ACCP reading the EEPROM [D]).
- On transmit, the hardware stamps the
Sourcefield with that station number (ch 3.2: "Source = station number of transmitting device"). When a CPU answers the ND-100, it sends an IDENT (ch 3.3 stream 1), and the frame carries its source station. - The ND-100 (station 1) reads the
Sourcefield of the received frame to know which CPU answered.
So responsibility is DISTRIBUTED: each CPU owns its identity via (its slot's EEPROM →
its octobus interface init → the Source field it stamps). No CPU reports for another; the
octobus guarantees unique station numbers. The microcode's role is only to inherit its
identity from the ACCP/backplane (SYS_READ of SYSPAR/CON5IDENT at INIT_SAMSON; SAMSON_CPU
patch constant is the CPU's own number) — it is NOT the authority for the station id.
EMULATION MAPPING [V — our code already models this]: OctobusFabric does dest→source
rewrite so each answer frame carries the originating OctobusND5000Station.StationNumber;
each station instance carries its own number = the "per-slot EEPROM station no." Multi-CPU
= multiple station instances, each with its own number 70B–73B — matching the hardware
"each CPU reports its own" model. The one thing NOT modeled is the EEPROM/init-parameter
plumbing (BADAP/Speed/Station-no load) — in the emulator the station number is assigned
directly, which is behaviorally equivalent [D].
4. CPU model / EEPROM (ch 2.1.6) [DOC — pairs with the microcode word-7 finding]¶
SET-CPU-MODELwrites the model (values 2/4/5/7/8) to the per-slot MF-backplane EEPROM;LIST-CONFIGURATIONreads it back (CPU MODEL: 000007B). Needs the updating tool's special PROMs (350156 Compact / 350157 large cabinet).- WARNING (ch 2.1.6):
INITIATE-EEPROMon the MF-controller slot orCONFIGURATE-SLOTon the CPU slot (with config saved) DESTROYS the CPU-model setting. - Cross-link: the model the MICROCODE reports to SINTRAN comes from control-store word 7
of the loaded image (see
docs/MC/README.md§3 +ND5000-FAMILY-MODELS-REFERENCE.md§1.6); the EEPROM model is the MF-bus hardware's separate copy — an upgrade sets BOTH (new microprogram floppy carries word 7 + updating tool writes the EEPROM), which is why every upgrade step pairs "replace microprogram version 14xxx" with "set CPU model".
5. Init / control-store load / ACCP (ch 3.6, 6.2) [DOC — relevant to CS-load gate]¶
- ACCP = Access Processor, with a console (ch 3.6.1) and an ND-5000 self-test (ch 3.6.2); self-test failure is a startup error (ch 6.2 "ND-5000 Self-Test Fails").
- Control-store loading (ch 6.2.1) + startup error messages (ch 6.2.2/6.2.3) — the live "Loading Control Store" behavior we model on the classic 3022 has an ND-5000/ACCP analog here; worth a targeted read when closing CS-load fidelity on the octobus generation.
- MF-bus TEST AND MAINTENANCE PROGRAM (ch 8.5): commands incl.
INIATE-EEPROM(212),LIST-OCTOBUS-STATION(215),OCTOBUS-SELFTEST(215) — the tooling that reads/writes the backplane config discussed in §3–4.
6. Chapter map — where to dig next (NOT yet analysed in depth)¶
- Ch 4 Hardware Trace Module — trace memory, software control, dump-on-error, decoding tools. Could inform an emulator trace/debug facility.
- Ch 6.2.2/6.2.3 error messages — the authoritative ND-5000 startup/error vocabulary; useful for matching emulator behavior to real diagnostics.
- Ch 7 ND-5000 Monitor debug commands — LOOK-AT-PROGRAM/DATA/STACK/REGISTER/SRF/ RESIDENT-MEMORY, breakpoints, address trace, trap handling, LIST-MEMORY-CONFIGURATION, "List E00 level and version". Directly relevant to the register-window / SRF model and to the live-oracle debugging approach (these are the commands to drive in a live capture).