Handoff: the ACCP control-store model, corrected end to end (2026-08-04)

Full path: E:\Dev\Ronny\NDInsight\SINTRAN\ND5000\HANDOFF-ACCP-CONTROL-STORE-MODEL-CORRECTED-2026-08-04.md WSL path: /mnt/e/Dev/Ronny/NDInsight/SINTRAN/ND5000/HANDOFF-ACCP-CONTROL-STORE-MODEL-CORRECTED-2026-08-04.md Date: 2026-08-04 Scope: the ACCP (ND-324716, MC68000) to ND-5000 control-store link in RetroCore Companions: HANDOFF-ACCP-LINK-SEAM-CONTRACT-2026-08-04.md (the living contract), ANSWER-CSA-QUESTION-FROM-LINK-AGENT-2026-08-04.md, HANDOFF-STARTMICROPROGRAM-SEAM-2026-08-04.md


THE HEADLINE

Five "MEASURED" facts about this link were wrong, and all five came from one root cause: the two latch bytes at 0x330000 and 0x330001 were being folded into a single register. 0x330001 sees 42,297 writes to 0x330000's 208, and holds bit 1 set almost permanently - so folding them held the control-store gate open across every shift sequence by accident, and the whole staging model was calibrated against that accident.

Claim Status
"The address is the NINTH GATED word" REPLACED - it is an address PHASE ending in command 0x3010
"The completed word must be LATCHED (gate closes and reopens)" REFUTED - a workaround for the spurious gate close
"Multiple shift+operate cycles inside ONE gate window" REFUTED - the gated staging buffer is never used at all
"0x0015 is the microprogram-run command" REFUTED - a generic strobe, 20,979 per boot
"0x00FF is an unmodelled register reading all-ones" REFUTED - a hard-coded immediate at ROM 0xCDA6

Anything else derived while the fold was active deserves the same scrutiny.

THE CORRECTED MODEL

The address phase - 0x76E6, called by EVERY path BEFORE the gate opens:

76ee  3d40 0014            move.w D0,(0x14,A6)              ; the address parameter
7704  33ee 0014 00550000   move.w (0x14,A6),(0x00550000).l  ; the address, written ONCE
770c  3084 / 3085          move.w D4,(A0) / move.w D5,(A0)  ; 16 clock pairs
7714  30bc 3010            move.w #0x3010,(A0)              ; LATCH IT AS THE ADDRESS
7728  30bc 0015            move.w #0x0015,(A0)              ; a generic strobe

Command words:

Word Meaning ROM
0x0018 perform the addressed control-store write 0x7446, 0x766C
0x2018 load the MIR 0x774C
0x2010 begin read-back verify 0x775A
0x2011 shift in one word 0x77B6
0x3010 latch the address 0x7714
0x0015 generic strobe, every access issues one 0x7728, 0x7904
0x0017 arm a microprogram start 0x78FC
0x0010/0x000F the clock pair, not commands

Gating: 0x330000 only. Bit 2 is the console path (0x7434), bit 1 the boot path (0x765A); both store the same 0x001144EE shadow to 0x330000. 0x330001 has its own shadow at 0x001144EF, is a different register, and what its bits select is OPEN.

The gate does not capture the shift. Audited by counting where each commit sourced its words over a real boot: latch / staging / ring = 0 / 0 / 8. Every microword is shifted out UNGATED. What the gate does select is unknown; "BUFFERED CI-bit groups" may still be the answer, but nothing has shown it.

The shift ring needs NINE slots. The address travels through the same 0x550000 port right after the eight halves, so eight slots evicted the first half and the microword committed one word out of step (33445566...F0010100 stored where 11223344...DDEEF001 was expected).

THE P0 ANSWER: EIGHT HALFWORDS

Asked: does microword 0x3FF0's low 64 bits get lost on write, or is it supplied by hardware?

Neither - the firmware writes all 128 bits. From the shift engine at 0x7776:

778a  lea     0x001144F0,A3      ; buffer start
7790  lea     (0x10,A3),A4       ; END = start + 0x10 = 16 BYTES
779c  move.w  #8,D3              ; 8 clock pairs per halfword
77a0  move.w  (A3),(A2)          ; halfword -> 0x550000
77aa  addq.l  #2,A3              ; next halfword
77ac  cmpa.l  A3,A4
77ae  bne.s   779C

A3 walks 0x1144F0 to 0x114500 in steps of 2 - 16 bytes, eight halfwords, 128 bits. The length is a hard-coded constant, so every path through 0x7776 sends eight; there is no four-halfword variant. 0x77B6 (shift in) is identical.

So if 0x3FF0's low half arrives wrong, it is a bug between the shift and the store, not a missing hardware contribution.

The runtime counter is built but its numbers are NOT quoted here. The test run came back with plausible values while the build had FAILED (CpuND5000.cs(2073,70): error CS0103: 'DfToD' does not exist), so they came from a stale DLL. Confirm against the counter once that builds.

MEASURED STATE

ACCP suite 141 passed, 0 failed
MIR loads per boot 284
addressed control-store writes per boot 8 (4 under the old model)
commits from latch / staging / ring 0 / 0 / 8
typed LOAD-CONTROL-STORE stores 112233445566778899AABBCCDDEEF001 at 0x0100

WHAT IS OPEN

  1. Implement IControlStoreSink.StartMicroprogram against the shared CpuND5000 - the station side owns this. It is the only thing between here and the card passing its own start/stop selftest, whose sole pass condition is word[6] of 0x001144F0 reading 0x0100.
  2. What the 0x330000 gate actually selects, now that it demonstrably does not capture the shift.
  3. What the 0x330001 bits mean - the start/stop sequence sets and clears bits 0..3 and ORs in 0x5C.
  4. Do 0x0017 and the octobus STARTMIC/ARMA path drive the same mechanism? If so they must share one model - two models of one register is the defect this whole document is about.

THE METHOD THAT ACTUALLY WORKED

Three hand-decodes of failed at CSA: 00FFH produced three different wrong answers. Two instruments in AccpMachine, both off by default, settled it in ~20 seconds of run time each:

  • WatchWordAddress -> WatchWordHits: one 16-bit cell; old value, new value, instruction count, and the PC of the instruction that had just retired.
  • TrapPcAddress + TrapFrameOffset -> TrapPcHits: D0, A6 and a frame word when a chosen instruction retires - for values living in a stack frame, which have no address to watch until A6 is known.

Fixture: E:\Dev\Repos\Ronny\RetroCore\Nuget\HackerCorpLabs.Emulation.Machines.Accp\tests\Nd5000CsaFailureTraceTests.cs

Rules earned the hard way today:

  • When a value cannot be traced statically, stop reading and measure.
  • A number a program prints is not necessarily a number it computed - check for an immediate first.
  • A round trip that agrees with itself proves nothing about what the far end is.
  • A green suite is not evidence that the REASON is right. Counters that name which path ran are.
  • Assert the build succeeded before believing any test number.