CARVE ANSWER - Octobus own-station number: read from INPUT STATUS (+2) bits 13:8, statically

Answers E:\Dev\Ronny\ND5000UC\CARVER-REQUEST-OCTOBUS-STATION-NUMBER-2026-07-18.md (how does SINTRAN/TPE read and validate the ND-100 octobus own station number).

Sources of truth: - D:\ND\S\testprog\x\octobus-b00.test (TPE OCTOBUS B00), full fresh disassembly this session via nd100-dis. File-to-VA mapping file word offset = VA - 0x6B00, double-validated against two independently known words from the 2026-07-16 carve (magic 0x71C7 at VA 0xd080 = file word 0x6580; station mask 0x3F00 at VA 0xd3cb = file word 0x68cb). All ram:xxxx addresses below are the same hex VAs as the Ghidra project. - SINTRAN\NPL-SOURCE\NPL\PH-P2-OPPSTART.NPL (OCSTART, CH5CPUPRESENT), MP-P2-N500.NPL / RP-P2-N500.NPL (5STATION usage), SINTRAN\NPL-SOURCE\SYMBOLS\L07\l07-kallsyms.txt (ASTAT symbol).

Tags: [V] = byte/source-cited, [I] = inferred with basis.


TL;DR - the four answers

  1. The own station number is read from the receive (INPUT) STATUS register (+2), bits 13:8 - a STATIC hardware readback of the thumbwheels. Routine ram:d704: read(+2); AND 0x3F00; SHR 8. It is read IMMEDIATELY AFTER an input master-clear and BEFORE any transmit, and stored to ctx[6]. The dest-0 loopback seen in your traces is the subsequent CROSS-CHECK, not the read. [V]
  2. The self-send cross-check transmits frame word 0x0000 (dest = station 0) and compares the PRE-TRANSMIT +2 station field against the received frame's bits 13:8 from +0. Master-clear comes FIRST (before both reads); +2 is read BEFORE the transmit, +0 once AFTER; there is NO master-clear between transmit and the reads, and +2 is NOT re-read after the frame arrives. Reply detection is a POLL of +2 bit 3 (up to 100 status reads); the input interrupt (ident 40B) is enabled and cross-checked as a diagnostic, but is not the detection mechanism. [V]
  3. The +2 station field is NOT a frame field at all. TPE requires it to hold the own station right after master-clear with an EMPTY input FIFO. Reads of +0 and master-clears must not change it. [V]
  4. Self-sends use TWO destination flavors: dest 0 (the LIST-HARDWARE-CONFIGURATION cross-check) and dest = own station (test 1). Both must be delivered back into the sender's own input side (RFT in +2, frame in +0 with hardware-stamped source station, input ident if enabled). Local-vs-bus routing is not observable from this binary; the polling window (~100 status reads) tolerates either. [V for the requirements; routing [I]]

Why your emulator prints STATION NO. = 0 and (patched) the cross-check error: ctx[6] comes from the +2 read at step 2 below. Your +2 station field is 0 unless a frame arrived, so ctx[6] = 0. Unpatched, the raw 0x0000 echo also has source 0, so 0 == 0, no error, prints 0. Patched to stamp station 1 into the echoed +0 data, the check compares ctx[6] = 0 (from +2, pre-transmit) vs 1 (from +0) and prints exactly "Receive status: 0 / Receive data: 1". The single correct fix is: +2 bits 13:8 must ALWAYS read the configured station number (thumbwheels), statically, independent of any received frame. That fixes the STATION NO. column, the Clear-Device status check, and the cross-check in one move. [V]


1. Q1 - where the own station number comes from

1.1 The read primitive [V]

ram:d704 (octobus_read_own_station_from_input_status):
  d707  rec.arg1 := dev            ; hardware device number (ctx[5])
  d70a  call d473                  ; = IOX read INPUT STATUS (+2) (d473 body: SAA 2, d733 IOXT)
  d70d  AND 0x3F00                 ; literal word at ram:d713 = 3f00
  d70e  SHA ZIN SHR 10(oct)        ; >> 8
  d70f  return A                   ; = station number

Companion ram:d715 is identical but AND 0x0030; >> 4 = +2 bits 5:4 = the "Speed" field (see section 3.3), stored to ctx[7]. [V]

1.2 Where it is called and stored [V]

cmd_list_hardware_configuration @ ram:7b24 calls the 3-phase controller prober ram:7242 three times with phase arguments 0, 1, 2 (computed jump through the table at ram:731e: phase 0 -> 7248, phase 1 -> 727d, phase 2 -> 72cf).

Phase 1 loops controllers 1..4 (index global [0x71e4], ctx = 0x7198 + 14i) and for each PRESENT controller (ctx[1] != 0) calls ram:c1f2* - the self-send cross-check - at ram:72a6. Inside c1f2:

c1f7-c1fc  write INPUT CONTROL (+3) := 020B      ; input master clear (d3f8)
c1fe-c203  A := d704(ctx[5])                     ; read +2, extract bits 13:8
c204-c205  ctx[6] := A                           ; <- THE own-station store
c206-c20a  ctx[7] := d715(ctx[5])                ; +2 bits 5:4 (Speed)

ctx[6] is populated from +2 BEFORE any transmit. The LIST-HARDWARE- CONFIGURATION "STATION NO." column is printed from ctx[6] afterwards. [V]

1.3 SINTRAN never reads it at all [V - NPL]

  • OCSTART (PH-P2-OPPSTART.NPL:4039, addr 063367): presence check = IOX read of HDEV+2 with IOX-error trap (TRR IIE / TRA IIC, error code 7 = absent), then T:=HDEV+DCONT; 20; IOXT and T+4; IOXT = 020B written to +3 and +7 ("CLEAR INTERFACE"). No station read anywhere. Comment: "THIS OCTOBUS DRIVER ONLY HANDLE ONE OCTOBUS INTERFACE (DEVICE 0)".
  • The ND-100 driver never needs its own station in software: the hardware inserts the source station into transmitted frames (manual section 3.2/3.3.1, and the TPE receive decode at ram:d3ae relies on it).
  • ND-5000 station numbers are CONSTANTS, not hardware reads: CH5CPUPRESENT (PH-P2-OPPSTART.NPL:063104) probes IOX 100406 (output status) for presence, polls bit 3 (ready), then ASTATION\/COMD=:5STATION. ASTATION resolves in the L07 symbol list to ASTAT = 0x38 = 070B (l07-kallsyms.txt:1653) [V value; the ASTAT=ASTATION 5-char truncation is [I], strong]. With COMD = CPU index 0..3 this yields stations 70B..73B for CPU 1..4 - matching the manual's station table. It then sends the "masterclear Samson system" kick: A SH 10 BONE CBIT BONE EBIT = station<<8 | C | E, \/CMMACLE -> IOX 100405, then \/CMACONT (continue ACCP). RP-P2-N500.NPL:976 confirms: X.CPUNO+FN5DEST-1=:X.5STATION.

(The requester's point that the ND-5000 CPU reads its own station from the backplane EEPROM {BADAP, Speed, Station no} is the other side of the same coin: each card has a local static source for its own number; on the ND-100 octobus interface that static source is exposed to software as +2 bits 13:8.)


2. Q2 - the exact self-send cross-check sequence [V]

Function ram:c1f2 (octobus_selfsend_station_crosscheck), called per present controller from LIST-HARDWARE-CONFIGURATION phase 1. Complete IOX order:

 1. +3 := 020B                     input master clear
 2. read +2 -> ctx[6] := bits13:8  OWN STATION (before any transmit!)
 3. read +2 -> ctx[7] := bits5:4   Speed field
 4. "Clear Device" verify (ram:c180 = c132 + c159):
      output side (ram:d676): +7 := 004B ; +7 := 0x50 (120B) ;
        poll +6 until (status AND 0x01FD) == 0x0008   (only RFT set), <=100 polls
        else "Wrong transmit status after Clear Device"
      input side (ram:d633):  +3 := 020B (master clear again) ;
        poll +2 until (status AND 0x3F3D) ==
                      (ctx[6] << 8) | (ctx[7] << 4) | 0x04, <=100 polls
        else "Wrong receive status after Clear Device"
        -- i.e. station field present, Speed unchanged, bit2 = 1, bit3 = 0,
           bits 0,1 = 0, with the FIFO EMPTY
 5. +7 := 0xFC01 (176001B)         output control: bit0 = interrupt enable +
                                   high-bit field(s) not decoded here [I]
 6. +3 := 041B  (0x21)             input control: bit0 = interrupt enable +
                                   bit5 (0x20; meaning not decodable from this
                                   binary [I])
 7. poll +6 bit3 (output RFT) <=100 (ram:c07a/d591); timeout ->
      "Not ready for transfer on transmit", abort (return 0)
 8. +5 := 0x0000                   THE SELF-SEND: pack {C=0,B=0,dest=0,byte=0}
                                   (ram:d6bf -> pack d3df -> write d3ce).
                                   Destination station field = 0.
 9. wait receive (ram:c0a9 mode 1 -> d5b8):
      poll +2 bit3 (input RFT) <=100 (ram:d591)
      PLUS interrupt cross-check: the level-13 ident service records input/output
      idents in flags [0x71e0]/[0x71df] (+ ident code in [0x71e2]); c0a9 reports
      "enabled but no interrupt" / "interrupt but not enabled" style diagnostics
      and spurious idents via [0x71de]. Detection itself is the POLL.
10. read +0 ONCE -> decode (ram:d3ae): srcStation = bits13:8 (mask 0x3F00)
11. compare ctx[6] (from step 2) vs srcStation (from step 10):
      not equal -> report ram:b0a3 = "The station number read from the receive
      status register is not equal the source station number read from the
      receive data register, when the controller sends a message to itself."
      printed values: "Receive status" = ctx[6], "Receive data" = srcStation.

Direct answers to the sub-questions:

  • What is transmitted: one frame word 0x0000 - dest station 0, data byte 0, C = B = 0. (ram:c22b-c235: d6bf(dev, 0, 0, 0, 0); pack proven at ram:d3df: frame = C<<15 | B<<14 | station<<8 | byte.)
  • Interrupt or poll: POLL of +2 bit 3. The input interrupt is ENABLED (041B, bit0) and its arrival is verified as a diagnostic through the level-13 ident bookkeeping, but a reply is accepted purely on the RFT poll.
  • Order of +2 vs +0: +2 FIRST - and crucially BEFORE the transmit (step 2); +0 once, after the frame arrives (step 10). The error text's "read from the receive status register" refers to the pre-transmit read. +2 is NOT re-read after reception for this check.
  • Master-clear position: BEFORE the reads/transmit (steps 1 and 4-input). Never between the transmit and the +0 read. Your emulator's observation ("TPE serviced 41B, master-cleared input, then read +2 = 0") fits step 4 of the NEXT controller iteration or a re-run - within one c1f2 pass there is no post-transmit master-clear. [V for the sequence; the trace alignment is [I]]

3. Q3 - receive STATUS (+2) station field semantics [V]

The station field in +2 is a constant readback of the configured own station number (hardware thumbwheels TH3/TH4 on PCB 3096):

  • It must be correct IMMEDIATELY AFTER an input master-clear (020B) with the FIFO empty: d633's expected value requires bit3 = 0 (no frame waiting) and bit2 = 1 while bits 13:8 = own station (step 4 above). So it cannot be "frame at FIFO head" or "last frame received" - there IS no frame.
  • It is read for the STATION NO. column before any traffic (step 2).
  • Neither master-clear nor reads of +0 may change it (the same value must satisfy step 2, step 4's poll, and the step 11 comparison).

3.2 What the "source station of a received frame" actually is

The per-frame source station lives in bits 13:8 of the received DATA word read from +0 (decode ram:d3ae, mask 0x3F00 at ram:d3cb) - hardware inserts it into every frame. The +2 field is a different, static thing that happens to use the same bit positions.

3.3 TPE's own register documentation (DECODE-STATUS-REGISTER strings) [V]

INPUT status (+2), string block at ~ram:a5f4:

Bit Meaning (TPE text) Note
0 Interrupt enable readback of control bit 0 (shadowed by TPE at [0xd39e])
1 Not used
2 "Fifo full" label text; the Clear-Device check REQUIRES bit2 = 1 on an EMPTY fifo, so the wire sense is "room available" - your FifoNotFull is right
3 Ready for transfer = frame available (RFT)
4-5 Speed text says "bit 3-5 - Speed"; the code mask is 0x0030 (ram:d715), so bits 5:4
6-7 Not used
8-13 Station number the static own-station field
14-15 Not used

OUTPUT status (+6), string block just before it:

Bit Meaning
0 Interrupt enable
1 Not used
2 Request on (RQ)
3 Ready for transfer (RT)
4 Error
5 Retry counter 0 (RE)
6 Not present (NP)
7 Busy (BU)
8 Parity error (PA)
9-14 Not used
15 Master

(Bits 2-8 match the transmission-statistics mapping already verified in OCTOBUS-TEST-PROTOCOL-RE.md section 2. Bit 15 "Master" is new - it ties to the "No new master is selected / Master, Octobus station number:" strings at ~ram:bd6e; that master-selection test was not carved this pass.)


4. Q4 - self-send routing [V requirements / [I] mechanism]

TPE uses two self-send flavors:

  1. dest = 0 (frame 0x0000) - the LIST-HARDWARE-CONFIGURATION cross-check (ram:c1f2, described above). The error string calls this "sends a message to itself", i.e. destination 0 is treated as self.
  2. dest = own station (frame = ctx[6]<<8) - ram:c1a3, whose literal-pool reference sits in test 1 (test1_transmit_receive_loop @ ram:7d9d). Sequence: Clear Device -> +7 := 0xFC01 -> +3 := 1 (int enable only, NO bit5) -> wait output RFT -> transmit ownStation<<8 -> wait INPUT frame (c0a9 mode 1) -> also wait OUTPUT completion (c0a9 mode 0). [V]

What the hardware must do (either flavor): deliver the frame back into the sender's OWN input side - input RFT sets, the frame appears in +0 with the hardware-stamped source station (= own station), and the input ident (40B) fires if input control bit0 is set. The output side completes normally (41B).

Immediate vs bus-delayed: not observable from this binary. Both waits are 100-iteration status polls, so a bus round-trip latency is fully tolerated. Emulator recommendation: immediate-consistent delivery is the simplest model that satisfies every check; nothing in TPE requires bus delay. [I]

Related self-referential behavior proven in the same pass: the presence scanner ram:c479 (fills ctx[10..13], the "STATIONS SEEN" bitmap) skips its own station (if station == ctx[6] -> next, ram:c49b-c49e) - self-presence is never probed on the bus. Each other station 1..62 is probed with: Clear Device -> +7 := 1 -> wait output RFT -> transmit C-frame 0x8000 | station<<8 | 0xA2 -> wait output completion -> station present = output status bit6 (Not present) CLEAR (ram:d56a). [V]


5. New/renamed functions for the Ghidra map [V]

Address Suggested name What it is
ram:7242 octobus_probe_controllers_phase switch(arg 0/1/2) via table ram:731e; loops controllers 1..4 over 0x7198 ctx table
ram:7248 .phase0: presence probe per controller (ctx[1] := c196 result; c196 -> e48d = IOX-trap probe)
ram:727d .phase1: calls c1f2 per present controller
ram:72cf .phase2: calls c4f3 per present controller (needs ctx[1] AND ctx[2])
ram:7321 octobus_ensure_probed_select_first runs phase 0 once ([0x71eb] guard), selects first present controller into [0x71e5]/[0x71e6]
ram:c1f2 octobus_selfsend_station_crosscheck section 2; the ONLY caller of reporter b0a3
ram:c1a3 octobus_selfsend_to_own_station test-1 helper; dest = ctx[6]
ram:c180 octobus_clear_device_verify_both = c132 (output) + c159 (input), ANDs results
ram:c132 / ram:d676 clear-device check, OUTPUT side +7:=4; +7:=0x50; poll +6 (mask 0x01FD == 0x08); reporter a3fb
ram:c159 / ram:d633 clear-device check, INPUT side +3:=020B; poll +2 (mask 0x3F3D == st<<8|spd<<4|4); reporter a64b
ram:c479 octobus_probe_presence_bitmap per-station probe loop, skips own station
ram:c4f3 / ram:c51f phase2 wrapper / bitmap stability compare c479 into local, copy to ctx[10..13]; c51f re-reads and compares (reporter b035)
ram:c07a octobus_wait_output_rft d591(side=0) + timeout reporters a7fe/a74c
ram:c0a9 octobus_wait_frame_and_check_ints d5b8 + spurious-ident ([0x71de]) and int-expectation diagnostics
ram:d591 octobus_poll_rft poll +2 or +6 bit 3, <=100 ([0x71e3] counter)
ram:d5b8 octobus_wait_transfer_record_ints d591 twice + snapshots [0x71df]/[0x71e0]/[0x71e1]/[0x71e2]
ram:d704 octobus_read_own_station_from_input_status (+2 AND 0x3F00) >> 8
ram:d715 octobus_read_speed_from_input_status (+2 AND 0x0030) >> 4
ram:d6bf octobus_send_single_frame pack {C,B,station,byte} (d3df) -> +5 (d3ce)
ram:d6e2 octobus_receive_single_frame_decode +0 (d3a0) -> decode (d3ae) ->
ram:d56a octobus_station_present_from_np read +6, return NOT bit6 (Not present)
ram:d57e octobus_output_error_bit read +6, return bit4 (Error)
ram:b0a3 report_selfsend_station_mismatch owns the section-2 error string (~ram:b136)
ram:b526 report_response_station_vs_receive_data owns "...station number in the Test Protocol response ... not equal ... receive data register" (~ram:b5c7) - refines the earlier generic "header reporter" label

Globals refined: [0x71de] spurious/unexpected-ident flag (cleared by ident service d740 and by c0a9), [0x71df] output-ident-received flag, [0x71e0] input-ident-received flag, [0x71e1] ident-arrived flag, [0x71e2] captured ident code, [0x71e3] poll countdown, [0x71e4] controller loop index, [0x71e5] first-present controller, [0x71eb] probed-once guard, [0xd39e]/[0xd39f] input/output interrupt-enable shadows (set by d3f8/d434 from value bit 0), [0x71a5] per-controller bookkeeping bit words (EXR-computed bit set/clear). Register wrappers: d726 iox_write(dev+off), d733 iox_read, d3a0 read +0, d473 read +2, d3f8 write +3, d3ce write +5, d4ce read +6, d434 write +7, d740 level-13 IDENT (clears [0x71de], returns ident code).

6. What was NOT carved (honest gaps)

  • The meaning of output-control value 0xFC01's high bits (retry count is the obvious candidate for a multi-bit field, but that is a GUESS - marked [I]; the manual's register description should settle it).
  • Input-control bit 5 (0x20) in the 041B write: not decodable from this binary.
  • The LIST-HARDWARE-CONFIGURATION row printer ram:78ef (which ctx fields feed the IDENT CODES columns) - not walked; STATION NO. = ctx[6] and STATIONS SEEN = ctx[10..13] popcount are established from the probe side.
  • The master-selection test (bit 15 / "No new master is selected") and the probe byte 0xA2's protocol-level meaning (E+M flags, OMD 2 per the manual's low-byte flag layout) - identified, not walked.
  • SOCTO/SOCTW receive-path handling of the +2 station field in SINTRAN: OCSTART and CH5CPUPRESENT are source-verified above; the interrupt-time driver body was not re-carved this pass.