RUN area level-14 livelock and IIC mis-decode: measured analysis (13/15-JUL-2026)

Solved 15-JUL-2026, commit 3acef36 (status-fence wiring + FIDBO swap fix; MOR wired to level 12 in the same commit). What remains open is only that RUN has never been run to its end and is not gated - see tests/instruction-verify/CAMPAIGN-STATUS.md. The superseded theories and the step-by-step log that led here are in git history.

INSTRUCTION-B RUN stalls right after == DUMMY OUTPUT STARTED == and never prints IOX-ERROR STARTED. Everything below is probe-measured on the FF-mode runSim build (probes: ND120_PROBE_RUNIDENT in runSim/Run120.cpp), after the tape-storm fix (C-device interrupts now actually assert BINT lines) and both CPU fixes (QREG dc61bd6, SSEL 2e2ea37).

Measured chain

  1. RUN starts its stressors. The dummy-output phase performs IOX writes that raise real IOX-error internal interrupts (ioxerr_n input pulses, ~every 1000 evals).
  2. Each pulse latches request bit 10 in CGA_INTR (IRSRC bit map: bits 0-3 = external levels 10-13; bits 8-13 = internal detects: 8=Z, 10=IOXERR, 11=PARERR, 12=NOR, 13=POWFAIL; latched in IRQ_REG RQBITs, set/hold until CLRQ).
  3. The CPU switches to PIL 14 correctly (measured PIL trace: ...10, 13, 12, then 14).
  4. THE FAULT: at PIL 14, EVERY macro instruction boundary re-dispatches the internal-interrupt service (csa 03756 -> EXT14 -> PLINT -> MACRI): measured 14,487 EXT14 dispatches for 14,486 MACRI boundaries in 1.1M evals, while TAIIC (the TRA IIC microcode at csa 03665, which ends in CLR14: R1:=037760; CLRXX: PIC,MCLPID = the internal-detect clear) stays FROZEN at 21 entries. The level-14 handler never executes its dismissal, the detect bit is immortal, levels 10-13 starve.

Why re-dispatch is not suppressed

CGA_INTR has NO PIL input - suppression of requests at-or-below the current level is done via the PIC mask register (MPIE, PICMASK in CNTLR/IRQ_MASK). The level-switch microcode reloads it on every switch (PLINT -> PLVO -> PICFM/PICF2, PIC,LMSK); for a switch TO level 14 the mask must disable the internal detect bits (the microcode's own constant 077760 = bits 4-13 appears at PICF2+1 for exactly this).

Measured during the storm: PICMASK stuck at 100562 (bits 9-13 = the internal detects LEFT ENABLED) and never rewritten - the PLINT loop cycles 01133-01142 (PLINT/PLVO+1/PLVO+2) taking the COND,F=0 F,RETURN early path and never reaches PICFM/PICF2 (01163-01171). The 21 successful TAIIC entries during startup prove the flow works in other conditions.

ROOT CAUSE FOUND: SBIT (status register bit) mis-wiring - schematic p.87

The DELILAH interrupt system is a close copy of the Am2914 Vectored Priority Interrupt Controller (Ronny, 13-JUL; confirmed against the 1978 Am2900 Family Data Book). The Am2914 rule that RUN depends on:

"The Read Vector microinstruction ... also automatically loads the value 'vector plus one' into the Status Register." (Am2900 Family Data Book)

The Status Register is the fence that stops the interrupt just taken from being re-dispatched. Our CGA_INTR_CNTLR_VECGEN_STAT implements it as six SBIT cells (schematic p.87), whose D input is:

D = (SIN & DCDG & DCDF & GPE)      <- load S-bus data   (LDSTAT)
  | (DCDG & DCDFN & STS)           <- hold
  | (VINN & DCDF & DCDGN)          <- load vector+1     (RDVECT)

TWO transcription bugs, both now schematic-verified with Ronny (13-JUL):

  1. Cell (..._STAT_SBIT.v GATES_3): the vector-load NAND's middle input was GPE; the sheet's SBIT detail box shows DCDF. With GPE there the vector+1 load could not fire.
  2. Instances (..._STAT.v, all six): the six SBIT blocks on the sheet are drawn WITHOUT pin names (only the detail box names them), so the original transcription had to guess the pin order - and four pins were rotated. Verified pin reads (Ronny, top SBIT = HISTAT2, pins from top): pin2 = the XNOR increment output (VINN = the vector+1 bit), pin3 = HIF (the group F strobe, also on HISTAT1/HISTAT0), pin6 = G_N (same on all six SBITs). Correct wiring: VINN=XNOR chain, DCDF/DCDFN=HIF/HIFN (LOF/LOFN), DCDG/DCDGN=G_N/G, GPE=HIF (LOF), SIN=S-bus. As previously wired (GPE=HIF with DCDG=HIF_n) the S-bus load term was self-contradictory (HIF & HIF_n), and VINN was tied to a uniform strobe instead of the per-bit increment - which is why the status registers only ever read all-zeros or all-ones (LOSTAT = 0 or 7, HISTAT = 0) in every probe.

Net effect: the Am2914 status fence never worked anywhere in this machine. Nothing but RUN exercises it (all 13 other INSTRUCTION-B areas pass with the fence dead), so it went unnoticed until the IOX-error stress storm - where the missing fence lets EXT14 re-dispatch at every macro boundary, starving the level-14 handler before it can reach its TRA IIC dismissal.

REGENERATION HAZARD: the Logisim CGA_INTR sheet needs the same corrections (cell GATES_3 input + the six instance pin maps) or regenerating CGA_INTR_CNTLR_VECGEN_STAT*.v reintroduces both bugs.

13-JUL: status-fence fix - the livelock is gone

With the corrected wiring (below) - now the RTL default; ND120_INTR_STATUS_FENCE_OFF restores the old dead fence:

fence dead (before) fence live (now)
EXT14 re-dispatches in the storm window 14 487 1
TRA IIC reached (the handler's dismissal) 21 (all pre-storm) 22 - it runs
HISTAT / LOSTAT stuck 0 / real values (7,3,2,5...)
CPU self-test passes passes (no regression)
INSTRUCTION-B boots yes yes

The level-14 livelock is FIXED. The final wiring (all four cases fall out of the confirmed cell equation + the MDCD strobe polarities):

DCDF/DCDFN = HIF / HIF_n     (group F strobe: RDVECT-of-this-group, LDSTAT)
DCDG/DCDGN = G / G_N         (G is ACTIVE LOW: 1 idle, 0 on RDVECT/MCLR)
VINN       = XNOR chain      (the vector+1 bits)
GPE        = HIGE / LOGE     (group-enable, the FIDBO3/FIDBO4 buffers)
SIN        = S-bus
  idle -> hold | LDSTAT -> load S-bus | RDVECT -> load vector+1 | MCLR -> clear

The earlier "self-test hangs with the fence on" was MY error, not a second RTL bug: I had DCDG/DCDGN swapped because I read G as active-high. The comparator (VECGEN_CMP/MAGCMP, p.88 - computes VGES = (V >= S), the correct Am2914 rule) and IRGEL (p.90-95) were AUDITED and are CORRECT - no changes needed there.

Verified NOT the cause

  • MDCD HIK/LOK strobe gates: match the schematic (p.96) exactly - D0N/D1N/ D4N with EPICN and the vector-clear-enable flops. A-OP 1 = CLRMPID and A-OP 4 = LCLRMPID are real PIC commands (Microprogrammer's Guide ND-06.031 ch.3) missing from the ND110Compile token table, but the DELILAH microcode NEVER issues them - DELILAH dismisses internal detects via CLR14/MCLPID (data-path J clear, measured working).
  • RQBIT latch semantics, IRSRC bit mapping, priority X-codes: all measured correct.
  • Unanswered IDENTs: handled gracefully (INSTRUCTION-B's init sweeps all levels with no devices answering and proceeds fine).
  • The C-model tape: answers and releases its level-12 IDENT correctly.

HIVCE hold-term input: ruled R (scan illegible - decided by analysis)

The schematic scan (p.96) is unreadable at the HIVCE flop's hold input - could be P or R (Ronny: leaning R, 13-JUL). RULED R by analysis: (1) the HI/LO halves are mirror-symmetric everywhere else and LOVCE legibly uses R; (2) R = the {MCLR,CLRMPID,LCLRMPID,RDVECT}&EPIC strobe, which gives the flop exactly the "armed by RDVECT until the next clear-family command" lifetime that LCLRMPID ("clear int for LAST vector read") requires; (3) the only P-candidate (IRGEL PD) has no functional story here. Our CGA_INTR_CNTLR_MDCD.v already uses the R-equivalent (s_gates41_out) for both flops - correct as-is, no change. Functionally inert either way on this machine (DELILAH microcode never issues LCLRMPID); re-verify only if some future microcode uses the vector-read clear.

15-JUL: IIC architecture confirmed (nd100x + ND-120 uc-emulator) - the exact mapping

TRA IIC (nd100x cpu_instr.c:1888) returns calcIIC() = HIGHEST SET BIT of (IID & IIE), then clears IID/IIC. IID is a SEPARATE register from the Am2914 IREQ. IID bit -> IIC code (console prints code in OCTAL): bit5=Z bit6=PI bit7=IOX bit8=PTY(10o) bit9=MOR(11o) bit10=POW(12o)

ND-120 uc-emulator note (Ronny): the two internal sources use DIFFERENT conventions in the model: IOX -> SetInterruptDetectbits(1<<10) = Am2914 IREQ bit 10 (hivec 2) MOR -> InternalInterruptLvl14(1<<9,..) = IID bit 9 directly

Reconciled mapping for our DELILAH hardware (IRSRC IREQ bits -> IIC): IOX IREQ10(hivec2) -> IID/IIC bit 7 (IIC 7) PAR IREQ11(hivec3) -> IID/IIC bit 8 (IIC 10o) MOR IREQ12(hivec4) -> IID/IIC bit 9 (IIC 11o) POW IREQ13(hivec5) -> IID/IIC bit 10 (IIC 12o) => IIC_bit = IREQ_bit - 3 (= hivec + 5)

15-JUL: ROOT CAUSE FOUND + FIXED - FIDBO[1]<->[2] swap

THE BUG: CGA_INTR_CNTLR.v:109-111 swapped FIDBO bits 1 and 2 on the status-fence write path (s_fidbo_2_0 -> VECGEN.FIDBO_2_0 -> HISIN/LOSIN, the value the microcode LDSTAT writes into the Am2914 status register): s_fidbo_2_0[1] = s_fidbo_15_0[2]; // WRONG (swapped) s_fidbo_2_0[2] = s_fidbo_15_0[1]; // WRONG (swapped) The swap maps 2<->4 and 3<->5 (values where bit1!=bit2); 0,1,6,7 unchanged.

WHY IT MISDECODES IOX AS MOR: the AIIC (TRA IIC) microcode scans the status fence: writes fence=Q, checks IRQ = (hivec >= status). The hardware stored histat = swap(Q&7) but the comparator used the UNSWAPPED hivec. For IOX (hivec 2): hivges passes only when swap(Q&7) <= 2, i.e. Q&7 in {0,1,4}; highest = 4. So the microcode brackets IOX at ITS fence value 4 and computes the IIC for vector 4 = MOR = IIC 11 octal, instead of vector 2 = IOX = IIC 7.

WHY ONLY RUN FAILED: only the LDSTAT (microcode-written status) path goes through this swap. The normal interrupt fence uses the hardware RDVECT vector+1 auto-load (VINN), which does NOT go through s_fidbo_2_0. So self- test, RTC (level 13), and all 13 instruction areas - which use RDVECT-based fencing - passed, and only RUN's internal-interrupt TRA IIC scan (LDSTAT- based, and the only test exercising vectors 2/3 through it) failed.

RED HERRINGS RULED OUT along the way (all measured): - The IIE&37760 mask DOES work: LMSK sets PICMASK[14]=1, hivec drops 6->2. (The C# LLM's "bit 14 leaks / mask missing" hypothesis was wrong for us.) - MOR wiring not firing (MOR-off run byte-identical). - Encoder (PTYENC), VHR, comparator (MAGCMP), OSMUX all verified correct. - The swap initially looked ruled-out because post-swap histat=2 read as "found vec 2" - but that was swap(4); the microcode's fence was 4.

FIX: CGA_INTR_CNTLR.v now assigns s_fidbo_2_0[2:0] straight through from s_fidbo_15_0[2:0] - one version, no ifdef and no escape hatch. The CGA_INTR_CNTLR_tb.v testbench carries dedicated FIDBO no-swap assertions. VALIDATED 15-JUL: self-test 0 STERR, unit suite 49/49, all 13 instruction-verify areas unchanged, and RUN handles IOX-ERROR and reaches LEVEL 13 / ARGUMENT == END OF TEST == (the reference RUN-console-ND120.log sequence). That is one area's end inside RUN's level loop, not the end of RUN: RUN as a whole is still NOT proven and not gated (see tests/instruction-verify/CAMPAIGN-STATUS.md).

C# behavior (TRA IIC clears IOX/MOR sources, keeps level-14 bit 14) is CORRECT - matches nd100x (gIID=0 clears sources, gPID bit14 separate). Not a bug.