DAP (Debug Adapter Protocol) integration in nd500x¶
Full path of this document: docs/DAP_INTEGRATION.md
nd500x has a working DAP server so the emulator can be driven from VS Code or any DAP client (including the dap-debugger MCP server). The integration mirrors the sibling nd100x emulator.
Default port: 4500 (nd100x uses 4711; the ND-500 emulator uses 4500 so both can run side by side).
Starting the server¶
# Headless: load a DOM and serve DAP until the client disconnects
./build/bin/nd500x --dom program.dom --dap # port 4500
./build/bin/nd500x --dom program.dom --dap 4600 # explicit port
# From the interactive REPL
./build/bin/nd500x --debug
nd500> dap # port 4500
nd500> dap 4600 # explicit port
With --dap the CPU does not start running until the client sends
continue (or launch without stopAtEntry).
Architecture¶
| Piece | Full path |
|---|---|
| DAP adapter (all command callbacks) | src/debugger/dap_adapter.c |
| Protocol library (vendored submodule) | external/libdap/ |
| Breakpoint/watchpoint engine (shared with CLI) | src/machine/breakpoints.c |
Register-name table (shared with CLI set) |
src/machine/debug_api.c |
| Unit tests | test/test_dap_adapter.c |
- libdap owns the TCP transport, JSON parsing and response serialization.
The adapter only implements
static int cmd_xxx(DAPServer*)callbacks that read parsed arguments fromserver->current_command.context.<cmd>and write results back into the same struct. - The DAP server runs on its own pthread pumping
dap_server_run()every 10 ms. Callbacks never execute the CPU; continue/step ask the machine run-thread to run (nd500_dbg_run) or perform one synchronous step. - Stop reporting: the CPU sets
m->run_flag = 0andm->stop_reasonwhen a breakpoint, watchpoint or trap hits (src/cpu/cpu.c,src/machine/io.c). TheDAP_CHECK_CPU_EVENTShook polls this every server loop iteration and sends the DAPstoppedevent (reasons:breakpoint,data breakpoint,step,pause,exception). - Breakpoints and watchpoints go into the same
BreakpointManager(m->bp_mgr) that the CLIbp/wpcommands use. The adapter tracks which entries it created so DAP replace-all semantics never remove CLI-created breakpoints. - Debugger memory access uses
nd500_dbg_mem_read_raw/write_raw, which bypass the bus layer so DAP reads and writes never trigger watchpoints. - When no DAP server has been started there is no additional per-instruction cost: no thread exists and the only hot-path checks (breakpoint manager consults) predate the DAP work.
Address spaces¶
Memory references accept the nd100x prefixes:
phys:/P:- raw physical addressdspace:/D:(and no prefix) - virtual address, translated through the data page tables when the MMU is enabledispace:/I:- virtual address, translated through the program page tables
Translation happens page by page (2 KB ND-500 pages) via
nd500_mmu_translate. Translations from the DAP thread never leave a CPU
trap pending (any trap raised by a debugger-initiated translation is
cleared immediately).
Data breakpoints (watchpoints)¶
dataBreakpointInfo resolves a symbol or address expression and returns a
dataId of the form:
V:0xADDRESS:LENGTH virtual address (translated via MMU at set time)
P:0xADDRESS:LENGTH physical address (used as-is)
setDataBreakpoints parses the dataId and calls wp_add() with
WP_TYPE_READ and/or WP_TYPE_WRITE (accessType readWrite creates both).
The watchpoint engine observes physical bus addresses, so virtual watch
addresses are translated when the watchpoint is set.
Registers as variables¶
Eight scopes mirror the CLI regs command's sections (the canonical ND-500
register report):
- Core (1001): PC, FLAGS, ST1, ST2, plus the Flags ASCII summary (PDZSCKO, uppercase=set) with the individual flags nested under it
- Integer Registers (1002): I1-I4 (W/H/BY/BI aliases in the description)
- Float Registers (1003): A1-A4, E1-E4, plus computed read-only D1-D4 (64-bit E:A converted to IEEE754)
- Addressing (1004): L, B, R
- Special (1005): TOS, LL, HL, THA
- MMU / Domain (1200): CED, CAD, PS, PSTP, DITBASE
- Trap Control (1006): OTE1/2, CTE1/2, MTE1/2, TEMM1/2
- Status Flags (1100): P, D, Z, S, C, K, O decoded from ST1
Register watchpoints (break on change) are available for PC, I1-I4, L, B, R
via dataBreakpointInfo/setDataBreakpoints with a register name (dataId
R:<NAME>) - the same engine the CLI wp reg <name> uses, now checked in
the CPU step loop.
setVariable writes registers by name; evaluate accepts a register name,
a symbol, or a numeric literal. The name-to-storage mapping lives in one
table in src/machine/debug_api.c
(nd500_dbg_reg_set_by_name etc.), shared with the CLI set command.
Console I/O (custom commands, nd100x convention)¶
consoleEnableswitches the SINTRAN MON console to the captured queue implementation; program output is then streamed to the client as DAPoutputevents (categorystdout).consoleWritequeues keyboard input. Backslash escapes\r,\n,\t,\\are translated;hex:input mode sends raw bytes.
Building and testing¶
make # DAP built automatically when external/libdap exists
make without-dap # SKIP_LIBDAP=ON, adapter compiled out
cd build && ctest # includes the dap_adapter unit test
./build/bin/test_dap_adapter # run the adapter unit tests directly
The unit tests (test/test_dap_adapter.c) drive the registered callbacks
through a transport-less DAPServer via nd500_dap_bind() and verify
machine-side effects (BreakpointManager contents, memory, registers).
End-to-end testing was done with the dap-debugger MCP client against
nc-a06.dom: instruction breakpoints, stopped events, stepping, pause,
register/memory inspection, virtual/physical reads, data breakpoints,
register watchpoints and console I/O, including catching the known NC
compiler crash at PC=0x08023EA4 (protection violation, wild pointer in a
heap linked list) as a live stopped event with reason exception.
The complete per-command test matrix (usage variants and results) is in
docs/DAP_COMMAND_TEST_MATRIX.md. Behaviour bug
reports from client-side sessions go to
docs/DAP_BUG_REPORTS.md.