ND linker LOAD <obj> — error 52 investigation (blocker #1, LOAD object load)¶
CLOSED 2026-08-09 — every blocker in this document is fixed¶
OPEN-DOMAIN + LOAD works, the full link produces a running .DOM, and the
result is correct. Nothing below is a live bug. Read the rest as a record of how
it was found, not as a task list.
The run that closes it (2026-08-09)¶
Harness build/bin/diag_linkdrive, rebuilt from scratch first (make diag) —
the copy on disk was two weeks stale. Run from the $ND500USERS tree:
OPEN-DOMAIN "HTEST";;LOAD HELLO;;LOAD NC-LIB;;LOAD CAT-LIB;;
DEFINE-ENTRY stack-space,400000,d;;DEFINE-ENTRY heap-space,400000,d;;
REFER-ENTRY stack-space,rts_stack_size,d,d;;
REFER-ENTRY heap-space,rts_heap_size,d,d;;CLOSE;;EXIT
LOAD HELLO reports, with no error code:
Program:........164B P01 Data:...........164B D01 Debug:.........262B Bytes
The link completes and writes GUEST/HTEST.DOM (6,312,200 bytes). Loading and
stepping that domain gives a clean exit, and the right answer — HELLO.C is
int x; int main(){ x = 42; return x; } and after the run 0x0800006C holds
00 00 00 2A:
programHELLO terminated
execution time 0:00:00
[STOP] MON halt: Program exit (MON 0B LEAVE)
Stopped: MON halt at 0x08002FDA (after 15383 instructions)
Which commit fixed what — bisected, not assumed¶
Three separate faults, each producing a different error code, each fixed by a
different commit. Established by git bisect over faa46cc..4401ac5 in a
throwaway worktree, rebuilding the emulator and re-running the linker at every
step:
| Error | Fixed by | Cause |
|---|---|---|
(-677:52) |
177fa229 fix(libmon): DEABF returns version-qualified name |
DEABF returned B:NRF with no version; the linker rejects a version-less object name before opening it |
(0054:67) "no current domain" |
bce9562 fix(libmon): 256B DEABF returns K CLEAR on success, not K SET |
measured: 288402d still returns (0054:67), bce9562 does not |
(0054:16) "illegal control byte" |
a3047b1 fix(cpu): LOOPI index uses the instruction data type, not forced WORD |
H LOOPI:B b.0x14 read as WORD also swallowed b.0x16, so the NRF record scanner consumed one length byte too few and desynchronised |
So the last blocker went on 2026-07-20, with a3047b1. That commit's own
message already records LOAD TEST printing a Program:/Data: summary. This
document was simply never updated and described a dead blocker for three weeks.
Two traps hit while closing this — read before re-running anything here¶
- A stale harness produced a confident wrong answer. Two bisect runs were
void: the build step preferred the CMake target
diag_linkdrive, which does not exist before17b4c1e, and then fell through to a[ -x bw/bin/diag_linkdrive ]test that was still true from the previous, newer commit's build. Every step after the first therefore tested one new binary against every commit. It named177fa229, which agreed with what this document already claimed — that agreement is exactly what made it hard to spot. It was caught only becausefaa46ccreported GOOD on one run and BROKEN on another. Any bisect here must deletebw/bin/diag_linkdriveandbw/lib/*.abefore each build. $ND500USERScannot run pre-2026-07-19 code. ItsSYSTEM/holdsDDBTABLES-G06.VTMand depends on the later un-revisioned-name fallback in50B OPEN. Older commits fail the open, takeDDBTABLES-E.VTMinstead, and die with "Format of found DDBTABLES is not supported by this VTM" long before reachingLOAD. Bisecting needs a copy of the tree with aDDBTABLES-G.VTMadded.
Known bad data in the sandbox¶
GUEST/B.NRF, GUEST/A.NRF and GUEST/HOUT.NRF were all 0 bytes, which
is how this closure nearly went wrong: the first attempt at the "Reproduce"
command below reported Program:..........4B P01 and looked like a result. It
was measuring an empty file.
A.NRF and B.NRF were rebuilt 2026-08-09 through the real toolchain
(NC-A06 CHECK + GENERATE-CODE, nested CAT-500 codegen) driven by two new
MODE scripts alongside the existing COMPILE-HELLO.MODE:
| Object | Source | Size | Links to | Verified |
|---|---|---|---|---|
A.NRF |
A.C = int x;main(){ x = 1;} |
950 B | ATEST.DOM |
runs, exits via MON 0B LEAVE, x = 1 |
B.NRF |
B.C = x = VALUE (42) |
953 B | BTEST.DOM |
runs, exits via MON 0B LEAVE, x = 42 |
HOUT.NRF is still 0 bytes and cannot be rebuilt: there is no HOUT.C or
any other HOUT source in the sandbox, in $ND500_TESTDATA, or anywhere else
searched. The copy at $ND500_TESTDATA/ND500USERS/GUEST/HOUT.NRF is also 0
bytes. Treat it as an orphan, not as data.
One thing that changed and is not a fault¶
At CLOSE the linker now finds and runs LINKER-AUTO-FORT:JOB — it loads
(SYSTEM)NC-LIB and (SYSTEM)CAT-LIB and issues the DEFINE-ENTRY/REFER
lines itself. Scripts that also do those by hand get
*** WARNING - Redefinition of STACK-SPACE = 400000B ignored, which is
harmless. Older notes saying the auto-job is missing are out of date.
*** SOLVED 2026-07-19: root cause = DEABF returned a VERSION-LESS name ***¶
The linker's LOAD rejects a resolved object name that lacks a SINTRAN version.
Our 256B DEABF/FullFileName returned B:NRF (no version); the Monitor Calls manual
(ND-860228, 256B FULLFILENAME) states DEABF returns "the directory, the user, the file
name, the file type, AND the version." Appending the default version ;1 to FOUND
files (B:NRF;1) makes the linker open the object (50B OPEN ./GUEST/B.NRF as file
102) and proceed — the days-old (-677:52) is gone.
- Fix:
src/libmon/handlers/mon_256B_FullFileName.c— the four found-filesnprintfbranches now append;1. Only FOUND files get it (a not-yet- created file still returns not-found/err-46, so NC's create-if-missing is unchanged). - Verified: NC gate
dom_nc_compile4/4 still pass.mon_callsunit test fails but that is PRE-EXISTING (fails identically with the fix reverted — its DEABF fixture file is absent in the test env, hitting the not-found path; plus an unrelated 312B check). - How it was found: the earlier "gate B0040D75 / b.0x49 / K" framing was a dead end. A
MON-level trace showed that right after DEABF success the linker does NO file open — it
jumps straight to reading the error-message file and printing
(-677:52). So the reject is a check on DEABF's OUTPUT. The manual named the missing field (version); a one-line experiment (;1) confirmed it by making50B OPENfire.
(historical, FIXED by bce9562) "no current domain" — CHARACTERIZED 2026-07-19¶
MON-level trace of the full run (deterministic) pins the behaviour:
- OPEN-DOMAIN "A-TEST" (quoted create):
50B OPENcreate A-TEST.DOM (file 101) ->120B WFILE4096-byte empty header at block 0 ->256B DEABF'A-TEST:DOM;1' ->43B CLOSEfile 101. It then OPENs the ERROR-MESSAGE file (UE-ERMSG) and RFILEs it to format the(0000:00)success line. It NEVER reopens A-TEST.DOM. So OPEN-DOMAIN persists an empty domain file + prints success, but leaves NO open/current domain and (apparently) does not set the linker's in-memory current-domain pointer. - LOAD B:NRF (with the version fix):
50B OPENB.NRF (file 102) ->43B CLOSE-> current-domain check FAILS ->*** ERROR - Command not valid when no current domain or segment exists. (0054:67). Object handling is now fully correct; the fault is purely the missing current-domain state.
Manual truth (ND-860289 ND Linker): the workflow IS OPEN-DOMAIN "X" then LOAD
(p.197-200), and LOAD loads into "the current domain" (p.958). OPEN-DOMAIN must make the
new domain current. 0xB0048CC8 (=1) is NOT that state (already ruled out).
NEXT PROBE: find the linker's in-memory current-domain variable (the one LOAD's (0054:67) gate reads) and determine why OPEN-DOMAIN's quoted-create path does not set it — candidates: (a) the create path diverges from the open-existing path before the "set current" store; (b) OPEN-DOMAIN expects to read back a VALID domain header (ours is 4096 zeros) to build the descriptor and skips "set current" when the header is empty/invalid; (c) a MON call in the create path returns a value our emulation gets wrong. Approach: watch memory writes during OPEN-DOMAIN, then find which the LOAD gate reads as zero.
(historical) NEW frontier note (superseded by the characterization above): "no current domain"¶
With the object now opening, LOAD B:NRF hits:
*** ERROR - Command not valid when no current domain or segment exists. (0054:67)
OPEN-DOMAIN "A-TEST" DOES create the .DOM file (50B OPEN file 101 + 120B WFILE
4096-byte header), but it does not leave the linker's internal current-domain/segment
context set for the subsequent LOAD. Next step: trace what OPEN-DOMAIN must set (an
in-memory current-domain pointer/flag) that our emulation leaves unset, or whether
OPEN-DOMAIN needs a follow-up step. NOT caused by the ;1 fix (reproduces from a clean
domain create). The 0xB0048CC8 global (=1) is not this state.
(historical) original error-52 investigation follows¶
Full path: docs/LINKER-LOAD-ERROR52-INVESTIGATION.md
Date: 2026-07-18
Run from: build/link_sandbox (NOT nc_sandbox) — that directory no longer
exists; the linker now runs from the $ND500USERS tree. See the CLOSED section
at the top of this file.
Driver: ../bin/diag_linkdrive $ND500_TESTDATA/nd-linker/linker-b01.dom 'OPEN-DOMAIN "A-TEST";;LOAD B:NRF;;EXIT;;'
(delete GUEST/A-TEST.DOM between runs — quoted OPEN-DOMAIN create errors -62 if it already exists)
Status¶
- FIXED this session: the LOAD field re-prompt loop and
EXITB:NRFinput concatenation. Root cause: DEABF success did not setW1/i1 = 0, soi1kept the MON trampoline's leftover call-target0xF80000AE(0xF8000000 + 0xAE; 0xAE = 256B octal = DEABF's own routine number), which the linker read as a nonzero error code. Fix:ctx->set_i1(ctx->cpu, 0)on success insrc/libmon/handlers/mon_256B_FullFileName.c. Verified: OPEN-DOMAIN still creates+reads the domain; EXIT exits cleanly (MON 0B LEAVE); no infinite re-prompt. - STILL BLOCKED:
LOAD B:NRFnever50B OPENsB.NRF. After DEABF resolves the name, the linker raises error 52 ("(-677:52)", blank message) and returns to the command prompt. The object is never opened/read/relocated.
The error-52 site (byte-level, verified by BREAK/disasm)¶
Routine B0040C3C (ents $0x100) is the LOAD command's name handler. It:
- Parses the command-line string into a stage counter
b.0x49by scanning for delimiter chars (before calling DEABF):;(0x3B) ->b.0x49 = 2(B0040C79 / B0040C7E))(0x29) ->b.0x49 = 3(B0040C86 / B0040C8B):(0x3A) -> setsb.0x4Cflag, does NOT touch b.0x49 (B0040CA9..).(0x2E) ->b.0x49 = 4(B0040CBC / B0040CC1) The parsed string is the WHOLE command line atb.0x18(e.g. "LOAD B:NRF", dumped at 0xB0048FEC =4C 4F 41 44 20 42 3A 4E 52 46+ spaces). "B:NRF" has a:but no., sob.0x49stays 1.
B0040D44: setsb.0xD8 = 0xAEandcall B004D4F4(the universal MON-invoke dispatcher) -> runs DEABF (256B). DEABF now returns success (i1=0, K=1).B0040D75:if -k go B0040D7D.- K SET ->
call B0040C44= PROCEED (open/load the object). - K CLEAR ->
B0040D7D:by comp2 b.0x49,$4; if >< go B0040D85(ERROR-52). So K-clear only survives ifb.0x49 == 4. Observed at B0040D75 (LOAD round):ST1=0x62(K CLEAR),b.0x49 = 1,I1 = 0-> falls to B0040D7D -> b.0x49 != 4 -> error 52.
- K SET ->
Why K is clear at B0040D75 (the crux, UNRESOLVED)¶
The dispatcher B004D4F4 runs the callg (DEABF) at B004DA08, then
B004DA13 if k go B004DBF1 (K set) / B004DBD0 (K clear). BOTH result paths
converge at B004DBF6 and end in a plain ret (B004DBFA), which CLEARS K
(RET clears K; RETK sets it — confirmed by the Ifkret work, commit 20a9082). So
the dispatcher structurally returns K CLEAR regardless of the MON's K. Therefore
at B0040D75 K is ALWAYS clear, and success MUST come via b.0x49 == 4.
But b.0x49 is parsed from the raw command line "LOAD B:NRF", which has no .,
so it is 1. Feeding LOAD B:NRF. (explicit period) makes the parser reach
b.0x49 = 4 and suppresses error 52 — BUT it then takes an early branch that
skips DEABF and the load entirely (no open, no read), so the period is a red
herring, not a fix.
The open contradiction (needs carve/manual truth)¶
On real hardware LOAD B:NRF + CR must load the object. Yet:
- the dispatcher returns K clear (by
ret), and - the command-line parse of "LOAD B:NRF" yields
b.0x49 = 1(no.). So neither B0040D75 success route is satisfied by our emulation. Something about the real command-buffer contents, the command terminator, or the dispatcher's K/return handling differs from ours. Candidates to verify against the carve / ND-500 linker + SINTRAN command-processor docs:
- Command terminator: what byte terminates a linker command line in the
buffer the parser scans? Our DVINST stores CR (0x0D) and the linker's buffer
ends up space-padded with NO terminator; the parser wants a specific
delimiter. Does SINTRAN's terminal input deliver/convert to
.(0x2E), CR, or something the parser treats as end-of-command that also advances/【bypasses】 the b.0x49 gate? - Dispatcher K contract: does
B004D4F4really return K clear on MON success, and is B0040D75 therefore meant to pass viab.0x49 == 4— meaning the parsed buffer on real hardware DOES contain the delimiter that yields 4? - What is linker error 52? (context "-677"). Its message slot is blank in
UE-ERMSG-EN-C06.ERR; it is a linker-internal code, not a SINTRAN file error. Knowing its meaning would confirm whether this is a syntax/parse error or a load-step error.
Round-2 confirmations (2026-07-18) — the contradiction is airtight¶
Every emulator-side assumption was verified; none is a bug:
RETcorrectly clears K (src/cpu/instructions/CALL/Ret.c:43; matches the manual and the linker's RET=success / RETK=error convention). So the dispatcherB004D4F4ending inret(B004DBFA) returning K-clear is CORRECT.B004D4F4returns K-clear on every path: entry doesjumpg B005482C(arg-count jump table); all arg-count slots (0..N args, callgs at B004D9D9/E6/F6/DA08) converge toB004DBF6 -> ret. Confirmed by disasm.:is the correct SINTRAN type separator (not.):LOAD B.NRFmakes DEABF resolve nameB.NRF+ typeNRF-> host./GUEST/B.NRF.NRF(double, not found).LOAD B:NRFcorrectly resolvesB:NRF->./GUEST/B.NRF(found).LINKER.INITuses CR (0x0D) line terminators, not.— andLIST/SET-ADVANCED-MODEwork CR-terminated. So.is NOT a universal command terminator; only the LOAD routineB0040C3Cdemandsb.0x49==4.- The parse runs exactly once during LOAD (single
B0040C59hit), on the valid nameB:NRF(the:handler fires), correctly yieldingb.0x49=1.
Net: K is correctly clear AND b.0x49 is correctly 1 for a valid LOAD B:NRF, so
BOTH success routes at B0040D75 are unavailable -> error 52 — yet the real linker
loads LOAD B:NRF. The resolution is therefore in the linker's LOAD command
contract, NOT in any single MON/CPU behaviour we can see from here. This needs
the ND-500 linker (ND-500 Loader/Linker manual) and/or the S3FS carve — see the
three carve questions above, plus:
- What is the FULL control flow of the LOAD command handler between reading the
command line and opening the object file? Specifically: what must be true at
B0040D75 (routine B0040C3C) for LOAD to proceed to
call B0040C44— is it K,b.0x49==4, or is B0040C3C a pre-parse whose error-52 is caught/retried by a caller we have not traced? Where is the50B OPENof the object.NRF?
Session 2026-07-19 — independent re-derivation + Loader/Linker manual located¶
Re-verified the whole chain from scratch (fresh disasm of the loaded
linker-b01.dom, virtual addresses via nd500x --debug d 0x...); every step
matches the round-2 analysis above. Nothing new is broken; the contradiction is
confirmed a THIRD independent way.
- LOAD handler dispatcher call + gate, disassembled directly:
There is NO instruction between the call (D5C) and the gate (D75) that could set K from the returned W1. The gate reads K exactly as the dispatcher leaves it.
B0040D44: w move #174,b.216 ; b.216 = 0xAE = 256B = DEABF routine no. B0040D5C: call B004D4F4,$10,b.216,IND(b.196),... ; universal MON-invoke helper B0040D75: if-kgo $8 -> B0040D7D ; if NOT K -> b.0x49 check B0040D77: call B0040C44,$0 ; K SET -> PROCEED (load the object) B0040D7D: by comp2 b.73(=0x49),$4 ; K CLEAR -> need b.0x49 == 4, else err 52 - Dispatcher
B004D4F4slot for this callg isB004DA08;B004DA13 if k go B004DBF1 / B004DBD0, both converge toB004DBF6: w1:=b.12; w1=:r.12; ret(K clear). The K-set arm (B004DBF1) returns b.68 (DEABF's W1) as an error code; the K-clear arm (B004DBEDw stz b.12) returns 0. So with our DEABF returning K=1 + W1=0 the dispatcher returns 0/K-clear regardless — i.e. the DEABF K flag alone does NOT change the error-52 outcome (both polarities give K-clear at D75). => The DEABF success K polarity is a red herring for error 52; the gate needsb.0x49 == 4, which is set ONLY by a.in the pre-DEABF command-line scan.
- LOADER/LINKER MANUAL LOCATED:
$NDINSIGHT/Reference-Manuals/ ND-60.136.04A ND-500 Loader Monitor.md. It documents the OLD Linkage-Loader (NLL:SET-DOMAIN,LOAD-SEGMENT). Our binary is the NEW NDL (- ND LINKER, Version B01 10. January 1989 -, internal version 66.251), whose verbs areOPEN-DOMAIN/LOAD(confirmed in this binary's ownbuild/link_sandbox/GUEST/LINKER.HELP; the manual listsLOAD-SEGMENTas the "Related old Linkage-Loader command"). The manual does NOT document the NDL's internalb.0x49command parser, so it does not resolve the gate. A successful LOAD is documented (LINKER.HELP LOAD example) to printProgram:.....B Pxx Data:.....B Dxx.
- OPEN-DOMAIN behaviour fully traced (fresh domain, stale A-TEST.DOM removed):
50B OPEN "A-TEST":DOM(create, quoted) ->120B WFILE4096-byte header page ->256B DEABFecho ->43B CLOSE. Domain state is kept internally; the .DOM file is closed between commands. This all SUCCEEDS. Note: our quoted-create returns 076B "already exists" ifA-TEST.DOMis present, but the NDL OPEN-DOMAIN spec (LINKER.HELP) says an existing domain is ERASED — a separate, lower-priority correctness gap (only bites on re-link of an existing domain).
- LOAD path (fresh domain): reads
LOAD Bvia 511B DVIO ->256B DEABFresolvesB->B:NRF(K=1, i1=0, host./GUEST/B.NRFfound) -> error(-677:52). It never50B OPENsB.NRF. The117B RFILE FileNo=65 block 4seen next is the linker reading the still-open error-message fileUE-ERMSG-EN-C.ERRto format the (blank) error text, NOT reading B.NRF.
What b.0x49 == 4 MEANS (new, ruled a dead end)¶
Tested LOAD B.NRF (period) fresh. The (-677:52) is GONE — the period sets
b.0x49 = 4 and the gate passes — but the linker then prints
*** ERROR - Remote file-name .... So the . is NOT a type separator: the NDL
reads B.NRF as ND COSMOS remote-file syntax (remote system B, file
NRF). Confirmed by planting GUEST/B.NRF.NRF so our (colon-based) DEABF
resolves B.NRF->B.NRF:NRF: the linker still rejects it as a remote name.
=> b.0x49 == 4 is the REMOTE-FILE branch, irrelevant to a local object. : is
the correct type separator; LOAD B / LOAD B:NRF are the correct forms. The
period is definitively NOT a fix.
Microcode check — the K-flag hypothesis is CLOSED (ND-5000 microcode)¶
Checked the ND-5000 microcode directly ($ND5000UC/microcode/
MICRO-5800-A30.md, opcode table):
000701 RET | ... D,SC14 K,ZRO ... | -> RET clears K (micro-op K,ZRO)
000702 RETK | ... D,SC14 K,ONE ... | -> RETK sets K (micro-op K,ONE)
000706 RETB | ... K,ZRO ... | -> clears K
000707 RETBK | ... K,ONE ... | -> sets K
000774 SETK=K,ONE 000775 CLRK=K,ZRO
RET genuinely CLEARS K on real hardware — our Ret.c is correct, and the
dispatcher B004D4F4 really does return K-clear on every arm on real HW too.
=> K being clear at B0040D75 is NORMAL, not a divergence. The whole "why is K set
on real HW" question is a DEAD END: it is not set, and is not supposed to be.
Re-read of the gate with K ruled out (corrects the earlier framing)¶
With K-clear being correct, re-disassembling the branch targets shows B0040D75/ B0040D7D is NOT the error-52 emitter:
B0040D75: if-kgo -> B0040D7D ; K-clear (normal) path
B0040D77: call B0040C44 ; K-set only: entd; l=:b.184; w1=:b.12; ret (setup, then falls to D7D)
B0040D7D: by comp2 b.73,$4 ; b.0x49 == 4 (REMOTE) -> B0040D83 bi1 clr; ret (early return)
B0040D81: if>< -> B0040D85 ; b.0x49 != 4 (NORMAL) -> CONTINUES into the parser stage-machine
;=59, :=58, )=41,
'=39 via jumpg b.73), i.e. the same stage machine as B0040C3C. So for a normal
LOAD B:NRF the handler PROCEEDS past B0040D75; error 52 is emitted somewhere
DOWNSTREAM of the parser, not at this gate. The prior "B0040D75 gate => error 52"
framing is therefore imprecise: the gate is passed; the fault is later.
Corrected next step¶
Runtime-trace the ACTUAL executed instruction path from the DEABF return through to where error code 52 is produced (the diag BREAK/trace harness can do this, non-destructively) instead of static branch-reading. The K-flag and both manuals are exhausted; the remaining work is a linear trace of the parser/load continuation to the exact instruction that sets error 52.
(superseded) earlier framing: the single K question¶
The b.0x49 == 4 route is now RULED OUT (it is the remote-file branch, see
above). So on real hardware, for a local LOAD B / LOAD B:NRF, the ONLY way
past B0040D75 is K SET. The universal MON dispatcher B004D4F4 (which invokes
DEABF at slot B004DA08) structurally ends in ret (K clear) on every arm, so
in our model K is always clear at the gate. The whole blocker therefore reduces
to one question for the S3FS carve / a real-HW trace:
After
call B004D4F4returns to the LOAD handler at B0040D75, why is K SET on real hardware for a successful DEABF? Does the dispatcher's success arm actuallyretk(notret)? Does the LOAD handler set K from the returned W1 in a way we mis-decoded? Or does DEABF itself return via a path that leaves K set through the dispatcher?
Concretely, a real-HW trace need only report, at B0040D75 for LOAD B:NRF:
ST1 (is K set?), b.0x49, and I1. Everything reachable from the emulator +
both ND manuals (Loader/Monitor ND-60.136.04A and Monitor Calls ND-860228.2) is
now exhausted.
Session 2026-07-19 (part 2) — runtime trace executed (the "corrected next step")¶
Ran the non-destructive KWATCH / CALLTRACE / FTRACE harness over the LOAD round (instr window ~191530..194000). New, verified facts:
- The float-subsystem rebase does NOT affect this blocker:
LOAD B:NRFstill errors(-677:52)at the same place, byte-identical. Confirms the two are unrelated. - Post-DEABF control flow is now fully traced (CALLTRACE):
191530 B004DA11 (DEABF callg returns, K set, I1=0) <- DEABF success for B:NRF 191540 -> B0040D75 (the gate; PASSED, as the round-2 static analysis predicted) 191553..193088 scan loop B0040D89->DAA->DCE->DDA->B0040E53(loopi b.56,#127)->D89 i.e. a FIXED 127-iteration scan of the command buffer 193088 B0040E6D: RET -> returns to caller at B003D0E8 193088+ tail: B003D0E8 -> B003CFDA -> B0034AF1 / B0036ACD / B0040711 -> B0049903.. (B0049xxx/B004Axxx) = error MESSAGE FORMATTER - The LOAD line handler (B0040C3C/D75/127-byte scan) is a SUBROUTINE; B0040E6D is
its
ret. Its caller is at B003D0E8, which then dispatches viajumpg b.532(routine B003CFDA) into the tail. - "code 32" was a RED HERRING: the earlier KSET
I1=0x20 @B003F864isby1 sfill b.40at B003F861 space-filling a 156-byte line buffer (w move #156,b.40) before writing the error text. B003F855+ is the error-line FORMATTER, not the decision. - 52 (0x34) is NOT held in any I-reg across the tail window (FTRACE_VAL=0x34, no
hit), so
(-677:52)is computed/formatted, not passed as a bare register code.
Corrected next step (narrowed)¶
The error DECISION is upstream of the B003F855 formatter, in the tail
B003D0E8 -> B003CFDA(jumpg b.532) -> B0034AF1 / B0036ACD / B0040711 -> B0049903.
Next probe: CALLTRACE/step that chain to find the routine that PRODUCES the -677/52
pair (watch the memory word the formatter reads, or the arg passed into B0049903),
and determine what "-677:52" denotes (SINTRAN error record vs linker-internal). The
127-fixed-count scan (loopi b.56,#127) is also worth validating against the real
command-buffer length semantics.
Additional RULED-OUT items (2026-07-19 part 3)¶
- Global
0xB0048CC8is NOT the reject. B0036ACD doescomp2 [0xB0048CC8],$1; if< go(a domain/mode flag check). BREAK at B0036AD3 during the LOAD round (instr 193113) dumps0xB0048CC8 = 0x00000001, so1 < 1is FALSE -> the check PASSES and B0036ACD proceeds. The flag is correctly set by OPEN-DOMAIN (WATCH shows 1->FFFFFFFF->1 during startup, settled at 1). Not the cause. - B0049903 / B004A9xx / B004A69C are STRING/name utilities, not the error
reporter; they feed the B003F816/B003F855 line formatter (entered instr 193963
B003F7AA -> B003F816). B0036ACD returns early W1=1 only if the length routine B0040711 yieldsb.28-b.24+1 <= 0; in the LOAD round B0040711 returned W1=0 (valid), so that early-out did NOT fire either. - Net: gate, "code 32", the 0xB0048CC8 domain flag, and the B0040711 length early-out
are all RULED OUT. The
-677:52decision is still unpinned within the B003D0E8/B0032Bxx/B003A2xx/B00401FC tail. This needs a patient single-step of the ONE conditional that routes to the reporter (or the carve meaning of -677:52) -- a dedicated session; breadth-first call-tree mapping is not converging.
Reproduce¶
cd build/link_sandbox && rm -f GUEST/A-TEST.DOM
ND500X_PIN_CLOCK=1 ../bin/diag_linkdrive $ND500_TESTDATA/nd-linker/linker-b01.dom \
'OPEN-DOMAIN "A-TEST";;LOAD B:NRF;;EXIT;;' 2>&1 | grep -iE 'DEABF|\(-677|round='
# BREAK at the gate:
ND500X_PIN_CLOCK=1 ND500X_NOLOG=1 ND500X_BREAK_PC=0xB0040D75 \
ND500X_BREAK_DUMP_BREL=0x44 ND500X_BREAK_DUMPLEN=16 ../bin/diag_linkdrive ...
UPDATE 2026-07-19b: 257B FOPEN ruled OUT as the blocker; gate + control flow pinned¶
Investigated the "no current domain" blocker fresh with the diag_linkdrive disassembler (new ND500X_DISASM_AT/BASE/LEN feature) and calltrace.
Real, carve-grounded side-finding (LANDED, see SYNC-MON-257B-FOPEN-PRESENT-IN-SINTRAN-L.md)¶
During OPEN-DOMAIN, after creating the .DOM the linker does 312B MOINF on
257B and, if present, CALLS 257B FOPEN. Carve PROVED 257B IS present in
SINTRAN L: MCTAB[257B] @ 044-S3IDPIT (L-VSX-500) = 0x928A (0111212B), non-zero.
We were reporting it absent (STUB). Implemented FOPEN + flipped status + MOINF
now reports present. 40061/40061 + nc 4/4 pass. BUT this is the error-message-file
lookup path (FOPEN queries UE-ERMSG-EN-C:ERR), and LOAD STILL fails (0054:67).
So FOPEN is ORTHOGONAL to current-domain. Ruled out.
The current-domain check is a PURE IN-LINKER MEMORY VARIABLE (no MON call)¶
Extracted the MON calls the LOAD command makes: 256B DEABF (B:NRF;1) ->
50B OPEN B.NRF (file 102) -> 263B GDEVT -> 76B SETBS 4000 -> 43B CLOSE
file 102 -> 71B DESCF -> error. LOAD opens+validates+closes the object, then
checks current-domain and errors BEFORE loading. NO MON call queries or sets
current-domain. So OPEN-DOMAIN must set an in-linker memory variable that LOAD
reads, and our run leaves it zero/unset.
Gate mechanism pinned (disasm)¶
Command dispatcher region (disasm of B003D0A0..):
B003D0E2: call 0xB0040C3C ; LOAD command handler
B003D0E8: if-kgo +8 ; if K SET -> skip error (go B003D0F2)
B003D0EA: call 0xB003CFDA ; ELSE -> error handler (K clear == failure)
B0040D5C call B004D4F4 (universal MON dispatcher,
runs the DEABF/OPEN/SETBS/CLOSE above) -> B0040D75 -> scanner loop
B0040DAA->B0040DCE->B0040E53(127-byte scan)->B0040D89 (~5 passes) ->
B0040E6D ret -> B003D0E8 -> B003D100 ret -> B0034AF1 (error region) ->
B0034AF1 -> B0036ACD -> B0040711 -> B0049903 (error-message FORMATTER, fills a
156-byte line). Confirms the doc's earlier tail mapping.
NEXT PROBE (for a fresh session - this is a multi-layer disasm job)¶
The current-domain FAILURE is decided somewhere in the B0040D75 / B004D4F4 region BEFORE the scanner unwinds to B0034AF1. Two concrete tasks:
- Disassemble the OPEN-DOMAIN command handler's SUCCESS tail (the create path, around B004CAxx after the create/WFILE/CLOSE) and find the STORE to the current-domain variable - confirm whether that store executes in our run and what value it writes. Leading hypothesis (candidate b): the linker derives the current-domain id/pointer from the domain header, and our header is 4096 zeros -> derived id 0 -> LOAD's "!= 0" gate fails. A real create assigns a non-zero domain number even for empty content.
- Disassemble the LOAD-side current-domain test (in B0040D75/B004D4F4 region) to
get the EXACT data address it reads, then diff that address between
"OPEN-DOMAIN;LOAD" and bare-"LOAD" runs. If identical (zero) in both,
OPEN-DOMAIN's set-current never executed -> find why (early branch / value
from the empty header).
Tooling: diag_linkdrive now has ND500X_DISASM_AT=
ND500X_DISASM_BASE= ND500X_DISASM_LEN= (one-shot disasm on first PC hit, after feeds) and ND500X_CALLTRACE_LO/HI (prints PC discontinuities in an instr window). Rebuild diag_linkdrive with gcc (NOT make) against build/lib/*.a.
UPDATE 2026-07-19c: banner formatter is SHARED (success+error); decision is upstream in the frame¶
Kept hunting the current-domain variable with the diag_linkdrive disassembler + BREAK_PC frame/global dumps. New concrete facts:
The command executive B0034AF1 and the SHARED banner formatter¶
After a command handler returns, control reaches the command executive at B0034AF1. Relevant disasm:
B0034AFC: w1 =: <abs 0xB0048F60> ; store W1 to a linker global
B0034B02: test W1 ; if!=0 go +311
B0034B07: comp2 <abs 0xB0048CE0>, $11 ; if==go ...
B0034B10: comp2 <abs 0xB0048CE0>, $13 ; if!=go +135
B0034B1A: test b.144 ; if=go +59 -> B0034B57
B0034B57: bmove b.80,r.20 ; call 0xB0036ACD ; <-- SINTRAN result banner formatter
The success/error distinction is in the FRAME/regs, not the globals¶
Dumped the linker global control block 0xB0048C80..0xB0048DC0 at BOTH B0034B57 hits: BYTE-IDENTICAL between the success (OPEN-DOMAIN) and error (LOAD) runs. So the "(0000:00)" vs "(0054:67)" code is carried per-call, not in a global:
- OPEN-DOMAIN: B=B0001BD4 b.140=0x0C(12) I2=0x12(18) I4=0x0C(12) - LOAD: B=B0002274 b.140=0x05(5) I2=0x04(4) I4=0x03(3) The "no current domain" (0054:67) status is therefore DECIDED inside the LOAD command handler (upstream of B0034AF1) and passed down as the status code the banner formats. 0054B=44dec, 67B=55dec - not yet found verbatim in a reg/frame, so it is looked-up/computed, not a raw field.
Linker global control block map (0xB0048Cxx, byte-verified)¶
0xB0048CA0: "ERROR-CODE:VAR" ... "LANGUAGE:VAR" (config-variable name strings)
0xB0048CE0: 0x0000000D (=13) command code (comp'd to 11/13 in the executive)
0xB0048CEC: 0x00000001
0xB0048CFC: 0x0000001F (31) 0xB0048CF3: 0x00000028 (40)
0xB0048D68: ptr 0xB0048D18 0xB0048D74: ptr 0xB0048D18 (list head/tail, cnt 0x4F)
NEXT (fresh session): find the conditional that sets status 67 inside LOAD¶
The current-domain test + status assignment is inside the LOAD handler between its entry and the return to the executive - i.e. in the B0040C3C-parse -> B004D4F4-MON-dispatch -> B0040D75-scanner flow, or a sub-call thereof. Probe: BREAK at the LOAD-handler return and walk backwards, or watch for the first write of 0x37(55)/0x2C(44) or an error-index into the frame during the LOAD window [173830,191660]. The current-domain "handle" the handler reads is the real target; OPEN-DOMAIN must set it and our create path does not.
UPDATE 2026-07-19d: error code computed downstream; OPEN-DOMAIN handler call-chain located¶
Continued the current-domain-handle hunt. Ruled out the downstream layers and located the OPEN-DOMAIN handler body for next session.
The (0054:67) code is computed in the formatter, NOT stored in a global¶
- Executive
b.144(test b.144; if=go B0034B57) is NOT the error decider - it is the "run post-command autojob" flag:b.144 = ((W1==13)|b.440) & ((cmd==11)|(cmd==13)) & (global[0xB0048CC0]==1)(disasm B0034A80..B0034AD5). Both success and error reach the shared banner. - b.80 passed to the banner formatter B0036ACD is a descriptor
{ptr=0xB0048FEC, n1, n2}: OPEN-DOMAIN {12,19}, LOAD {5,9}. 0xB0048FEC is just the ECHOED COMMAND TEXT buffer ("OPEN-DOMAIN \"A-TEST\"" / "LOAD B:NRF"), not the code. - Dumped 0xB0048F60..0xB0049000 (linker status block) at BOTH banners: byte-identical except the echoed command. So (0054:67) is computed by the message path from the error condition, carried in regs/frame - the DECISION is upstream in the LOAD handler, already made before the banner.
OPEN-DOMAIN "create" MON sequence + handler location (for the set-current store)¶
OPEN-DOMAIN "A-TEST" create (instr window [104184,173830]):
50B OPEN "A-TEST":DOM (create, file 101) @ handler-called wrapper B004E80F/E874,
the create OPEN itself at instr 132725; then 76B SETBS 4000, 120B WFILE 4096
bytes block0 (the on-disk header), 256B DEABF, 43B CLOSE.
Call chain INTO the create (calltrace): ... B0020487 -> B0007195 -> B0002D92 ->
B000489B -> B0006D0C ... B0022688 ... B00226C5 -> B000061B -> B00026A2 -> ...
B000064C -> B004E80F (OPEN wrapper). The OPEN-DOMAIN command HANDLER lives up
this chain in the B0020487 / B0022688 / B0006Dxx region. NEXT SESSION: disassemble
that handler's body from its dispatch entry through its tail; find (a) the store
of the current-domain handle/pointer to a linker global and whether it executes,
and (b) the matching read on the LOAD side. Leading hypothesis unchanged: the
handle is derived from the domain and ends up 0 (our create writes a 4096-zero
header; check whether the WFILE buffer @0xB0013130 is structured on real HW).
Harness: diag_linkdrive now also supports ND500X_BREAK_AFTER=