Skip to content

ND-5000 '87 extension instructions

The ND-500 Reference Manual (ND-05.009.4, June 1987 edition) says the ND-5000 uses the same instructions as the ND-500, and that a number of new instructions were introduced with the ND-5000. These also run on ND-500/1 and ND-500/2 CPUs. The manual labels each of them ('87 extension) in its section heading. This page lists all of them, with the manual's own text for each, and says which are already in instructions.json and which are not.

Counts

Counted by tools/gen_87_extension_doc.py from the manual's labels and instructions.json. "Opcode entries" are the entries of instructions.json (what the emulator's tables call variants); "distinct opcodes" count each opcode value once, because some entries share an opcode.

Instructions Opcode entries Distinct opcodes
ND-500 base (not labelled '87), in instructions.json 229 1063 1033
'87 extension, already in instructions.json 23 34 34
All of instructions.json today 252 1097 1067
'87 extension according to the manual 25 not counted 46 (+ 0 instructions whose opcodes the script could not read)
ND-5000 total according to the manual (base + all '87) 254 not counted 1079 (+ 0 unread)

The ND-500 base row assumes instructions.json holds every non-'87 instruction of the manual. That was not checked here; only the '87 instructions were.

The instructions

Section Instruction What it does Manual page Opcodes in the manual Status in instructions.json Handler in nd500x
10.36 AMODB Integer modulo 0xFFBC to 0xFFC7 missing from instructions.json no opcode in the data, so no handler
10.37 ENTIER SIMULA Entier function 0xFDC7, 0xFDC8 in instructions.json, same opcodes yes, every opcode has a handler
15.15 PLCCN Convert PLANC descriptor to ND-500 descriptor 268 0xFFFD in instructions.json, same opcodes yes, every opcode has a handler
15.16 NCPLC Convert ND-500 descriptor to PLANC descriptor 269 0xFFFE in instructions.json, same opcodes no, illegal instruction trap
15.17 CLINIT Initialize local clock 270 0xFF1E in instructions.json, same opcodes yes, every opcode has a handler
15.18 CLREAD Read local clock 271 0xFF1F in instructions.json, same opcodes yes, every opcode has a handler
16.11 DDIRT Dump 'Dirty' 285 0xFFFA in instructions.json, with the manual's opcodes and also 0xFE1E yes, every opcode has a handler
16.26.1 RHOLE read from NUCLEUS Hole 301 0xFE9E missing from instructions.json no opcode in the data, so no handler
16.26.2 WHOLE write to NUCLEUS hole 302 0xFE9D in instructions.json, same opcodes no, illegal instruction trap
16.26.3 SEND Send to port 303 0xB6 in instructions.json, same opcodes no, illegal instruction trap
16.26.4 RECVE Receive from port 304 0xB7 in instructions.json, same opcodes no, illegal instruction trap
16.27.1 SREGBL Save register block 307 0xFFF7 in instructions.json, same opcodes yes, every opcode has a handler
16.27.2 LREGBL Load register block 308 0xFFF6 in instructions.json, same opcodes yes, every opcode has a handler
16.27.3 SCNTXT Save context block 309 0xFFF9 in instructions.json, same opcodes yes, every opcode has a handler
16.27.4 LCNTXT Load context block 310 0xFFF8 in instructions.json, same opcodes yes, every opcode has a handler
16.28 REXT Read from device external to CPU 311 0xFFE8, 0xFFE9, 0xFFEA, 0xFFEB in instructions.json, same opcodes yes, every opcode has a handler
16.29 WEXT Write to device external to CPU 312 0xFFEC, 0xFFED, 0xFFEE, 0xFFEF in instructions.json, same opcodes yes, every opcode has a handler
16.30 TOSSP Special load of TOS 313 0xFE9F in instructions.json, same opcodes no, illegal instruction trap
16.31 RPHS Read from physical segment 314 0xFFF5 in instructions.json, same opcodes yes, every opcode has a handler
16.32 WPHS Write to physical segment 315 0xFFF4 in instructions.json, same opcodes yes, every opcode has a handler
16.33 CAD Load CAD 316 0xFDBA in instructions.json, same opcodes yes, every opcode has a handler
16.34 JUMPS Call supervisor 317 0xB9 in instructions.json, same opcodes yes, every opcode has a handler
16.35 SVERS Store microprogram version 318 0xFFFB in instructions.json, same opcodes yes, every opcode has a handler
16.36 SCPUNO Store CPU number 319 0xFFFC in instructions.json, same opcodes yes, every opcode has a handler
16.37 PHYLADR Get physical address 320 0xFFF0, 0xFFF1, 0xFFF2, 0xFFF3 in instructions.json, same opcodes yes, every opcode has a handler

"Handler in nd500x" means the opcode has an entry in the dispatch table of src/cpu/nd500_instructions.c (read by the script). An opcode without an entry raises the illegal instruction trap. An entry says a handler exists, not that it is complete or correct; the header of each handler names what is unsettled.

Misprints in the manual's code tables found by the script:

  • AMODB (10.36): BYn AMODB: hex column gives 0xFFBC, octal column gives 0xFFBC, 0xFFBD, 0xFFBE, 0xFFBF; octal used
  • AMODB (10.36): Hn AMODB: hex column gives 0xFFC0, octal column gives 0xFFC0, 0xFFC1, 0xFFC2, 0xFFC3; octal used
  • AMODB (10.36): Wn AMODB: hex column gives 0xFFC4, octal column gives 0xFFC4, 0xFFC5, 0xFFC6, 0xFFC7; octal used
  • REXT (16.28): Wn REXT: hex column gives 0xFFE8, octal column gives 0xFFE8, 0xFFE9, 0xFFEA, 0xFFEB; octal used
  • WEXT (16.29): Wn WEXT: hex column gives 0xFFEC, octal column gives 0xFFEC, 0xFFED, 0xFFEE, 0xFFEF; octal used
  • SCPUNO (16.36): SCPUNO: hex column gives 0xFF7CC, octal column gives 0xFFFC; octal used

The manual text for each instruction

Copied from the manual's Markdown. Page headers and footers are dropped; the manual's tables are as printed.

10.36 AMODB - Integer modulo

Status in instructions.json: missing from instructions.json.

Handler in nd500x: no opcode in the data, so no handler.

Format: tn AMODB ,

Assembly notation Name Hex code Octal code
BYn AMODB byte integer modulo FFBCH 177674B+n-1
Hn AMODB halfword integer modulo FFCOH 177700B+n-1
Wn AMODB word integer modulo FFC4H 177704B+n-1

Operation:

<operand1> - ((operand1) div <operand2>) * <operand2> -> Res if   res = 0 then 0 -> result elseif   sign(res) >< sign() then res+ -> result else   res -> result endif

Description:

The specified register is loaded corresponding to the SIMULA IMOD definition. The function applies to integer operands only.

Trap Condition:

Divide by zero

Data Status Bits:

result = 0 -> Z result.signbit -> S

10.37 ENTIER - SIMULA Entier function

Status in instructions.json: in instructions.json, same opcodes. Class in the data: FLOAT_MATH.

Handler in nd500x: yes, every opcode has a handler.

Format: t ENTIER <source/r/t1>,<destination/w/w>

Assembly notation Name Hex code Octal code
F ENTIER float entier FDC7H 176707B
D ENTIER double float entier FDC8H 176710B

Operation:

if int(source) > source then
    int(source) - 1 -> destination
else
    int(source) -> destination
endif

Description:

The function calculates the integer part of the source in accordance to the SIMULA Entier definition and stores it as a 32 bit integer in the destination.

Data Status Bits:

  • result = 0 -> Z
  • .signbit -> S
  • integer overflow -> O
Page Title
160 ND-500 Reference Manual

Chapter 11

Arithmetical Instructions

15.15 PLCCN - Convert PLANC descriptor to ND-500 descriptor

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: W PLCCN \<source/r/W>,\<destination/w/W>

Assembly notation Name Hex code Octal code
W PLCCN convert to ND-500 descriptor FFFDH 177775B

Operation: (u-l+1) -> N a + 1 -> A

Description:

A PLANC descriptor is converted to an ND-500 descriptor.

The descriptors are as shown below:

Planc descriptor ND-500 descriptor
address (a) Number of elements (N)
lower (l) Address (A)
upper (u)

Data Status Bits: Number of elements = 0 -> Z Signbit -> S

15.16 NCPLC - Convert ND-500 descriptor to PLANC descriptor

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: no, illegal instruction trap.

Format: W NCPLC <source/r/W>,<destination/w/W>

Assembly notation Name Hex code Octal code
W NCPLC convert to PLANC descriptor FFFEH 177776B

Operation:

A -> a O -> l N - 1 -> u If u-l+1 < 0, 0 -> N

Description:

Convert ND-500 descriptor to planc descriptor.

The descriptors are as shown below:

ND-500 descriptor Planc descriptor
Number of elements (N) address (a)
Address (A) lower (l)
upper (u)

Data Status Bits:

Upper = O -> Z Signbit -> S

15.17 CLINIT - Initialize local clock

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Assembly notation Name Hex code Octal code
CLINIT initialize CPU's clock FF1EH 177436B

Operation: 0 ->

Description:

Privileged instruction

The CPU contains a local clock running at 1 microsecond cycle time.

Clock is reset and started.

Trap Conditions: None

Data Status Bits: Unaffected

15.18 CLREAD - Read local clock

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Assembly notation Name Hex code Octal code
CLREAD read CPU's clock FF1FH 177437B

Operation:

<clock> -> W1

Description:

The clock value is read into register number 1. Time is an integer value giving the number of microseconds since the last CLINIT instruction.

Note that the clock counts for a period of 2**32 microseconds after which it starts from zero again.

Trap Conditions:

None

Data Status Bits:

  • <clock> = 0 -> Z
  • <clock>.signbit -> S

16.11 DDIRT - Dump 'Dirty'

Status in instructions.json: in instructions.json, with the manual's opcodes and also 0xFE1E. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Assembly notation Name Hex code Octal code
DDIRT dump dirty FFFAH 177772B

Operation: Dump dirty

Description: Data marked 'dirty' in the data cache is written to the memory. If no cache is present, the instruction has no effect.

Trap Conditions: None

Data Status Bits: Unaffected

Example:

DDIRT

16.26.1 RHOLE - read from NUCLEUS Hole

Status in instructions.json: missing from instructions.json.

Handler in nd500x: no opcode in the data, so no handler.

Format: BY RHOLE (,)

Assembly notation Name Hex code Octal code
BY RHOLE Read hole FE9EH 177236B

Operation: while not end of strings do S(I1) -> D(I2), I1+1 -> I1, I2+1 -> I2 enddo

Description:

Bytes are moved from source hole to destination string until either source is empty or until destination is full.

String descriptor:

Length of source string
Start address of string

Hole descriptor:

Hole number
Reserved

Trap Conditions:

No access to hole : PV trap. Nothing moved, registers unchanged. The hole is not a message : IOV trap. Nothing moved, registers unchanged. Outside source or destination : Descriptor Range Trap.

Data Status Bits:

Outside source : K = 0, I1, I2 Unchanged, DR trap condition. Outside destination : K = 1, I1, I2 Unchanged, DR trap condition. Source empty : K = 0, I1, I2 next element. Destination full : K = 1, I1, I2 next element.

16.26.2 WHOLE - write to NUCLEUS hole

Status in instructions.json: in instructions.json, same opcodes. Class in the data: IO.

Handler in nd500x: no, illegal instruction trap.

Format: BY WHOLE <string/r/by/I1>, <hole/w/by/I2>

Assembly notation Name Hex code Octal code
BY WHOLE Write hole FE9DH 177235B

Operation: while not end of strings do S(I1) -> D(I2), I1+1 -> I1, I2+1 -> I2 enddo

Description:

Bytes are moved from source string to destination hole until either source is empty or until destination is full.

String descriptor:

Length of source string
Start address of string

Hole descriptor:

Hole number
Reserved

Trap Conditions:

  • No access to hole : PV trap. Nothing moved, registers unchanged.
  • The hole is not a message : IOV trap. Nothing moved, registers unchanged.
  • Outside source or destination : Descriptor Range Trap.

Data Status Bits:

  • Outside source : K = 0, I1, I2 Unchanged, DR trap condition.
  • Outside destination : K = 1, I1, I2 Unchanged, DR trap condition.
  • Source empty : K = 0, I1, I2 next element.
  • Destination full : K = 1, I1, I2 next element.

16.26.3 SEND - Send to port

Status in instructions.json: in instructions.json, same opcodes. Class in the data: IO.

Handler in nd500x: no, illegal instruction trap.

Format: W1 SEND \

Assembly notation Name Hex code Octal code
W1 SEND send to port B6H 266B

Operation: I1 -> \

Description:

Message of register 1 is sent to hole number as specified by the operand.

Trap Conditions: Protect violation, Illegal operand specifier

Data Status Bits: Unaffected

16.26.4 RECVE - Receive from port

Status in instructions.json: in instructions.json, same opcodes. Class in the data: IO.

Handler in nd500x: no, illegal instruction trap.

Format: W1 RECVE ,

Assembly notation Name Hex code Octal code
W1 RECVE receive from port B7H 267B

Operation: \ -> I1, length of message -> \

Description:

Receive message from hole number. Message is returned in register 1. Size of message is returned in 'number of bytes'.

Trap Conditions: Protect violation, Illegal operand specifier

Data Status Bits: Unaffected

16.27.1 SREGBL - Save register block

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: SREGBL {mask/r/W}, {address/r/W}

Assembly notation Name Hex code Octal code
SREGBL save register block FFF7H 177767B

Operation: Save register block registers in specified address according to 'mask'.

Description:

The registers specified in the mask are stored in logical memory locations addressed by {address} plus register number*4. The register numbers are shown in chapter 2.

16.27.2 LREGBL - Load register block

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: LREGBL ,

Assembly notation Name Hex code Octal code
LREGBL load register block FFF6H 177766B

Operation

Load register block from logical address according to 'mask'.

Description

The registers specified in the mask are loaded from logical memory locations addressed by {address} plus register number*4. The register numbers are shown in chapter 2.

When executed in non-privileged mode, the 'mask' will be reduced to include only registers that may be modified by assembly instructions in non privileged mode.

When included in the mask, registers residing in the domain information table are loaded from the logical address to the domain information table pointed out by PS and CED as result of the LREGBL instruction.

16.27.3 SCNTXT - Save context block

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: SCNTXT <mask/r/W>, <address/r/W>

Assembly notation Name Hex code Octal code
SCNTXT save context FFF9H 177771B

Operation: Store context block registers in specified address according to 'mask'.

Description:

Privileged instruction

Context block of current process number is saved in physical address according to 'mask'. If address = 0, context save area of the current process is used.

The registers specified in the mask are stored in locations addressed by <address> plus register number*4. The register numbers are shown in chapter 2.

When context save area is used, this is addressed by:

(process number+1)*400B + an operating system defined address.

16.27.4 LCNTXT - Load context block

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: LCNTXT <mask/r/W>,<address/r/W>,<process number/r/W>

Assembly notation Name Hex code Octal code
LCNTXT load context FFF8H 177770B

Operation: Load context block registers from specified address according to mask.

Description:

Privileged instruction

Context block of 'process number' is loaded from physical address according to 'mask'. If address = 0, context save area of the current process is used. If process number is less than 0, current process number is maintained.

The registers specified in the mask are loaded from locations addressed by <address> plus register number*4. The register numbers are shown in chapter 2.

When context block save area is used, this is addressed by:

(process number+1)*400B + an operating system defined address.

16.28 REXT - Read from device external to CPU

Status in instructions.json: in instructions.json, same opcodes. Class in the data: IO.

Handler in nd500x: yes, every opcode has a handler.

Format: Wn REXT \<device/r/W>

Assembly notation Name Hex code Octal code
Wn REXT read from external FFE8H 177750B+n-1

Operation: \ -> In

Description:

Privileged instruction.

Information is read from external device into the specified register. Further devices will be supported in later versions.

Device numbers:

Device = 0 : OCTO-bus / ACCP.

Data Status Bits:

Nothing read 1 -> K else 0 -> K

16.29 WEXT - Write to device external to CPU

Status in instructions.json: in instructions.json, same opcodes. Class in the data: IO.

Handler in nd500x: yes, every opcode has a handler.

Format: Wn WEXT

Assembly notation Name Hex code Octal code
Wn WEXT write to external device FFEC 177754B+n-1

Operation: In ->

Description:

Privileged instruction.

Information is written into external device from the specified register. Further devices will be supported in later versions.

Register 'n' is written to 'device'.

Device numbers:

Device = 0 : OCTO-bus / ACCP.

Data Status Bits:

Unable to write data 1 -> K else 0 -> K

16.30 TOSSP - Special load of TOS

Status in instructions.json: in instructions.json, same opcodes. Class in the data: MOVE.

Handler in nd500x: no, illegal instruction trap.

Format: TOSSP :=

Assembly notation Name Hex code Octal code
TOSSP special load of TOS FE9F 177237B

Operation: -> TOS

Description:

The TOS register is loaded from the operand. Before the value is loaded, a check on magnitude greater than B.SP is performed. If true, a stack overflow trap condition exists.

Trap condition: Stack overflow trap

Data Status Bits: = 0 -> Z .signbit -> S

16.31 RPHS - Read from physical segment

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: RPHS

Assembly notation Name Hex code Octal code
RPHS read from physical segment FFF5H 177765B

Operation:

while I1 > 0 do
  S([I4,I3) -> D(<domain number>.I2)
  I3 + 1 -> I3
  I2 + 1 -> I2
  I1 - 1 -> I1
enddo

Description:

Privileged instruction

Copy a number of bytes from logical address on physical segment to logical address on the domain.

  • I1 : Number of bytes to be moved.
  • I2 : Logical address on the domain.
  • I3 : Address on the physical segment.
  • I4 : Physical segment number.

Operand : domain number.

The copy operation is continued until the number of bytes left is equal to 0 (I1 = 0) or a page boundary is reached on the physical segment. Number of bytes to be moved is counted down and will be zero when the move operation is completed. The addresses are incremented during the copy operation.

The instruction is meant for use when copying data from a physical segment in one process to a domain in another. The physical segment number is used together with the physical segment table pointer to find the physical page number of the wanted data page or of the corresponding index page.

Data Status Bits:

  • no bytes left = 0 : 1 -> Z
  • page boundary and no bytes left < 0 : 0 -> Z

16.32 WPHS - Write to physical segment

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: WPHS <domain number/r/W>

Assembly notation Name Hex code Octal code
WPHS write to physical segment FFF4H 177764B

Operation:

while I1 > 0 do     S(domain number.I2) -> D(I4.I3)     I3 + 1 -> I3     I2 + 1 -> I2     I1 - 1 -> I1 enddo

Description:

Privileged instruction

Copy number of bytes from logical address on the domain to logical address on physical segment.

  • I1 : Number of bytes to be moved.
  • I2 : Logical address on the domain.
  • I3 : Address on the physical segment.
  • I4 : Physical segment number.
  • Operand : domain number.

The copy operation is continued until the number of bytes left is equal to 0 (I1 = 0) or a page boundary is reached on the physical segment. Number of bytes to be moved is counted down and will be zero when the move operation is completed. The addresses are incremented during the copy operation.

The instruction is meant for use when copying data to a physical segment in one process from a domain in another. The physical segment number is used together with the physical segment table pointer to find the physical page number of the wanted data page or of the corresponding index page.

Data Status Bits:

no bytes left = 0   : 1 -> Z page boundary and no bytes left < 0 : 0 -> Z

16.33 CAD - Load CAD

Status in instructions.json: in instructions.json, same opcodes. Class in the data: MOVE.

Handler in nd500x: yes, every opcode has a handler.

Format

CAD :=

Assembly Notation

Name Hex Code Octal Code
load CAD FDBAH 176672B

Operation

-> CAD

Description

Privileged instruction

Load current alternative domain register.

Data Status Bits

  • Operand = 0 -> Z
  • .signbit -> S

16.34 JUMPS - Call supervisor

Status in instructions.json: in instructions.json, same opcodes. Class in the data: BRANCH.

Handler in nd500x: yes, every opcode has a handler.

Format: JUMPS <address/r/W>

Assembly notation Name Hex code Octal code
JUMPS call supervisor B9H 271B

Operation: P -> context.P B -> context.B <address> -> P <cpuno> -> W1

Description:

Save P and B register in context block. Execution is started in <address>. The instruction implies SOLO mode.

W1 returns the ND-500/ND-5000 CPU number.

Trap Conditions: None

16.35 SVERS - Store microprogram version

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: SVERS <destination/w/w>

Assembly notation Name Hex code Octal code
SVERS store version FFFBH 177773B

Operation: <microprog.vers> -> <destination>

Description:

Store microprogram version to destination address.

Data Status Bits: Status bit set according to version.

16.36 SCPUNO - Store CPU number

Status in instructions.json: in instructions.json, same opcodes. Class in the data: STRING.

Handler in nd500x: yes, every opcode has a handler.

Format: SCPUNO

Assembly notation Name Hex code Octal code
SCPUNO store CPU number FF7CCH 177774B

Operation: <CPUNO> -> <destination>

Description:

Store CPU number in destination address.

Data Status Bits:

Status bit set according to CPU number.

16.37 PHYLADR - Get physical address

Status in instructions.json: in instructions.json, same opcodes. Class in the data: SYSTEM.

Handler in nd500x: yes, every opcode has a handler.

Format: tn PHYLADR

Assembly notation Name Hex code Octal code
tn PHYLADR get physical address FFF0+n-1 177760B+n-1

Operation:

tr(addr(operand)) -> In

Description:

The specified index register is loaded with the logical address of operand translated to physical ND-500/ND-5000 address.

Trap Conditions:

Data Status Bits: