Skip to content

Old-format domains (:PSEG + :DSEG + DESCRIPTION-FILE:DESC) run directly in the monitor shell

Date: 2026-09-15. nd500x change; C# (RetroCore) has no equivalent yet.

What changed

Typing a domain name at the nd500x monitor shell (nd500x --monitor, the run_500.sh path) used to resolve ONLY <user>/<NAME>.DOM then SYSTEM/<NAME>.DOM. A domain shipped in the OLD format - <NAME>:PSEG, <NAME>:DSEG, <NAME>:LINK plus an entry in the owning user's DESCRIPTION-FILE:DESC - gave NO SUCH COMMAND OR DOMAIN, and the only route was to convert it first with the vendor CONVERT-DOM-A03 program (docs/CONVERT_DOMAIN_FORMAT_AND_USAGE.md).

Now stage_domain() in src/frontend/nd500x/nd500x_shell.c falls back to the old format: it looks the typed name up (exact match, case-insensitive) in the current user's DESCRIPTION-FILE.DESC, then in SYSTEM/DESCRIPTION-FILE.DESC, and ndlib_load_old_domain() in src/ndlib/ndlib_dom.c stages the pair into the same in-memory image the :DOM reader produces, so ndlib_dom_load_to_machine() places it with no change. Both shell load paths use it: the @ prompt / RECOVER-DOMAIN, and the nested MON 317B UECOM runner.

The DESC byte layout is include/nd500_desc.h, a verbatim copy of src/include/nd500/desc.h from the pcc-nd500 tree (its offsets were read out of the ND-500 Loader/Debug Monitor's own print code and checked on 13 vendor floppies).

The mapping, and the evidence for every value

The staged image reproduces what CONVERT-DOM-A03 writes for the same files. Two conversions made under nd500x were dumped (header bytes 0xD8-0x104 and the segment table at 0x254) and compared with their DESC entries:

Field DESC entry (LINKAGE-LOAD-H02) Converted $ND500USERS/FLOPPY-USER/LINKAGE-LOAD-H02.DOM
start address STADR 0xB0000DD1 STADDR@0xD8 0xB0000DD1
THA 0xB0215310 THA@0xE0 0xB0215310
segment number PSEG use 0x00400000 = bit 22, DSEG use same segment table slot 22
PROG image .pseg 123989 bytes (PLB 0 + PSIZE 123988 + 1) seg 22 PROG SZ 123989, FLA 0, ATT 0x10002000
DATA image .dseg 2184977 bytes (DLB 75834 + DSIZE 2109142 + 1) seg 22 DATA SZ 2184977, FLA 0, ATT 0xE1002000
trap enable ENABLEINT 0x0FFE00AC OTE1@0xF0 0xFC015800, OTE2@0xEC 0x0000001F
TEMM (not in DESC) TEMM1@0x100 0xFFFFFA00, TEMM2@0xFC 0x0000001F
Field DESC entry (LED-B03) Converted $ND500USERS/SYSTEM/LED-NEW.DOM
start address 0x08000004 0x08000004
THA 0x0806011C 0x0806011C
segment number PSEG/DSEG use 0x00000002 = bit 1 slot 1
PROG / DATA .pseg 223695, .dseg 394525 SZ 223695 / 394525, FLA 0, same ATT values
trap enable ENABLEINT 0 OTE1 = OTE2 = 0
TEMM - same constant as above

Conclusions taken from that, and nothing more:

  • The WHOLE .pseg is the program segment image from segment offset 0, and the WHOLE .dseg is the data image from offset 0. DLB is NOT an offset into the segment (LINKAGE-LOAD has DLB 75834 and its converted DATA size is still the full file).
  • Segment number = the single set bit of the domain entry's PSEG/DSEG use bitmaps.
  • ENABLEINT -> OTE: all 15 set bits of 0x0FFE00AC land 9 bits higher in the 64-bit OTE (OTE1 low word, OTE2 high word): bits 2,3,5,7 -> OTE1 11,12,14,16; bits 17-22 -> OTE1 26-31; bits 23-27 -> OTE2 0-4. Implemented as OTE1 = ENABLEINT << 9, OTE2 = ENABLEINT >> 23. One non-zero witness only (plus LED's trivial zero). Exact for it; a second domain with a non-zero ENABLEINT would confirm or refute it.
  • TEMM is the same constant in both conversions and is copied as a constant. Its meaning was not derived.
  • Header identification bytes 4-7 = 97, 3, 0xF8, 0 as in both conversions (0xF8 carries the is-domain-file flag the reader tests).

What is refused rather than guessed

  • A domain whose DESC segment chain has more than one entry: the segment entry's own segment-number field is not decoded, so entries could not be assigned to segment slots. All 13 known DESC files have exactly one segment per domain with PSEG use == DSEG use.
  • A .pseg/.dseg whose byte count differs from PLB+PSIZE+1 / DLB+DSIZE+1: the files do not belong to that entry. Message names the file, its size and the expected size.
  • A missing segment file: message names the DESC, the segment name and the last path tried.
  • No abbreviation matching for old-format names (the :DOM path keeps the carved COMPS/GOBJI abbreviation rule; the DESC lookup needs the exact name).

Where the segment files are looked for

The DESC segment name has the form (directory:user)NAME. Candidates, in order, with root = the parent of the DESC's directory (the sintran-root/USER layout): <root>/<user>/NAME.PSEG, then the DESC's own directory, then <root>/SYSTEM/NAME.PSEG (the own-directory-then-(SYSTEM) rule every unqualified file open already follows). So LED-B03's DESC can live in the login user's directory while the pair stays under SYSTEM.

Verified runs (2026-09-15, build from this change)

  • LED-B03 typed as GUEST with $ND500USERS/GUEST/DESCRIPTION-FILE.DESC (a copy of $ND500_TESTDATA/LED/x/description-file.desc) and the pair under $ND500USERS/SYSTEM: placed in domain 1 at 0x08000004, painted the editor screen ("Main" window, LED: prompt, "August 24, 1988."), exited at end of piped input after 507595 instructions - the SAME instruction count and screen as running the converted LED-NEW.DOM.
  • LINKAGE-LOAD-H02 typed as DOMAIN-USER from that user's DESC: placed at 0xB0000DD1, printed the Nll: prompt, EXIT returned to the shell.
  • Truncated .dseg: refused with the size message; nothing placed.
  • ctest: 39 of 39 pass.

$ND500USERS/SYSTEM/DESCRIPTION-FILE.DESC is the LINKAGE-LOAD-H02 description file (2 domains: SCRATCH-DOMAIN, LINKAGE-LOAD-H02); it does not list LED-B03 and was not modified. Merging DESC files is not implemented: the 256-byte page header is not decoded, so a written DESC would be a guess.

For the C# side

RetroCore's loader reads :DOM only. To mirror: read the DESC entry with the offsets in include/nd500_desc.h, load both files whole as segment images at offset 0 into the bitmap's segment slot, copy STADR/THA, derive OTE as above, and refuse the same cases.