Handoff: the ND-5000 macro trap path - THA, ENTT retryability, abort flag¶
Date: 2026-10-05. Branch fix-5000 in nd500x (local only, nothing pushed),
plus one commit on nd100x. Lane: MACRO only - plain Nd5000 attach, no
--microword, no --accp.
Read docs/CURRENT-PLAN.md first; this document is the narrative for the
four plan sections added on 2026-10-05.
Goal¶
Get DOM programs running under real SINTRAN over the octobus - CPU-STAT and NC. Not reached. The run now gets roughly twice as far as it did and dies in a different place.
What was fixed, with the evidence¶
1. THA was zero for a whole run (segment-12 "bounds" fault)¶
Not a bounds fault at all. THA (trap handler address) is a DIT-resident
field at offset 182, indexed by CED, and nothing in nd500x ever sourced it -
it stayed 0. The swapper's trap-handler install loop then wrote handler
addresses to 0 + trapno*4; the n=12 store landed on the process's own THA
copy at offset 0x30 and the next store went to 0x0800481A.
Oracle: the ND-5000 symbolic control-store listing MICRO-5800-B30.LIST
(location indexed in docs/EXTERNAL-ARTIFACTS.md) - 012210 LOAD_THA and
012233 STOR_THA both route through 012035 CED_TO_DIT, which builds a DIT
address from SRF14 (CED). So THA is read from memory on every access, not
held in a register.
Fixes:
src/cpu/cpu.c:nd500_dit_read_tha,nd500_dit_read_ith,nd500_dit_write_ith,nd500_is_in_trap_handler,nd500_set_in_trap_handler. The DIT is the single holder of ITH when configured; the C struct field is only the fallback.- nd100x
src/machine/mfbus_bridge.c: the THA read belongs inmfbus_declare_capability_table, NOT inmfbus_load_context. Placed inmfbus_load_contextit runs before DITBASE is set and reads the PREVIOUS process's PCB - which shows up as crossed PS/DIT pairs in the log.
Verified after the fix: the install loop's counter at logical 0x34 climbs
9 -> 41 and stops, segment 13 demand-pages through all 63 pages, and the
handler for trap 38 is 0x08004924 = 0x080047C2 + 29 steps, 12 bytes apart,
each an entt.
2. ENTT was not retryable - 503 RETT refusals¶
RETT ... Not in trap handler fired 503 times in one run. Root cause: ENTT
set B before writing its 47-word frame. A page fault partway through the
frame restarted the instruction with B already changed, and the restarted
ENTT took its instruction-sequence-error arm.
Proof: the per-step trace shows B=0x00000004 then B=0x08001728 at the
same PC.
Fix, aligned with the C# (Entt.c): pre-validate the whole frame span
(180 + 40 bytes) with nd500_mmu_peek_space before any mutation; on a hole,
report the page fault against cpu->trap_saved_PC - the ORIGINAL trapping
instruction, not fi->address. Emulated.Tests.ND500's
EnttFaultRestartTests.cs states that restart-at-ENTT "can never be the
design", because every process continue runs 011370B and the restarted ENTT
takes its ISE arm. B, TOS and L are set at the END, behind a terminal
abort guard.
Measured: refusals 503 -> 0, parks 70 -> 131.
3. The abort flag, where the C# unwinds instead¶
The C# throws Nd500InstructionAbortException and catches it in
CpuND500.Execute.cs:716 with UnwindOnAbortedAccess default true, so it is
abort-safe by construction. nd500x has no unwind, so every access site needs
if (nd500_trap_occurred() || cpu->instr_aborted) return;.
The two emulators agree on the model: the flag is set in exactly one place
(C# CpuND500.Trap.cs:940, C src/cpu/cpu.c:1578), for non-ignorable traps
only, and cleared per step at the top (C# Execute.cs:628, C cpu.c:252).
Real defects found by the systematic CALL/ENT/RET comparison, not by single-file reasoning:
instruction_helpers.c:nd500_load_string_descriptorreturnedtrueunconditionally, making 27 STRING-class checks dead code.CALL/Call.c:121andCALL/Callg.c:244: out-of-bounds WRITES - the argument loops ran toND500_MAX_OPERANDS(258) against apending_call_arg_addresses[256]array. Rebounded toTRAP_SEQ_MAXARG.CALL/Entm.c:TOScommitted between the guards; moved below the terminal guard besideB/L.BRANCH/{Loop,Loopd,Loopi}.c: a faulted index write-back could still commit the branch PC.cpu_instr.cmmu_read8/16/32: no abort check after the translate.
The open failure - where the next session starts¶
With 952441d the run ends in:
FATAL * 21B:77B * ND-500(0) Monitor Internal
Fatal internal system error - ND-500(0) CPU locked
Reason..............ND-5000 lock timeout
preceded by about sixty IDENTICAL parks:
parked on trap 46B at P=0x8004924 fault=0x8001800 psn=11
That is the ENTT frame write faulting, correctly refusing to half-apply, and SINTRAN never satisfying the page-in - so it re-faults until the monitor gives up. Distinct park PCs for the whole run: 0x8000004, 0x8000012, 0x800453B, 0x800467F, 0x8004751, 0x8004924.
Two things to measure rather than assume:
- the same fault was reported
psn=12in earlier runs andpsn=11now. The ENTT frame atTHA+256 = 0x08001728spans into 0x08001800, so WHICH physical segment that lands in is itself a measurement. - nd500x lacks the C#'s one-fault-per-instruction suppression
(
CpuND500.MMU.cs:1646), so one instruction can re-fault many times. That may be what the monitor is seeing.
Recorded, NOT changed - each needs its own evidence first¶
- Flags committed after a faulted destination store. Systemic, eight classes.
- Raw translate-then-access sites outside
src/cpu/instructions/:nd500_fecall.c:868-881,nd500_mon_sintran.c:72/91/143/156/169/186,nd500_ndix_boot.c:95, the trap-vector fetch atcpu.c:1918, and the debugger paths. SYSTEM/Swap.c's non-retryable half-done swap. Shared gap; the C# relies on its unwind.- The string corruption
(YSTSMS S S S S S)TERMINAL-1- no candidate. perform_block_copyodd-trailing-byte parity defect.- Segment 11's missing instruction-side pages; segment 14 never reached.
Traps that cost time in THIS session - do not repeat them¶
- A pool snapshot only decodes correctly in its OWN run. Physical
placement is per-run:
pa = 0x74800 + (logical & 0xFFFFFF)in one snapshot,0x7F7800in the next. A branch was reported as the divergence from a disassembly of the wrong run's snapshot, and retracted.ND500X_VWATCH=<hex>[:<len>](added insrc/cpu/nd500_settings.c/.h, reported bynd500_ptewatch_wrinsrc/machine/io.c) exists because of this and logs PC, vaddr AND paddr together. MFBUS_PCDUMPis a stop-time PC sampler, not an execution tracer. It reporting nothing for an address is NOT evidence the address never executed.- Watch the address the instruction computes, not the one in the source
text.
b.0x18withB=0x1Cis address 0x34. - The trap sink is what RECORDS a raise. Calling only
nd500_stop_on_trapwithout offering to the sink first regressed the run from 319 parks to 68. Do both, inraise_trap's order. - The sink always returns 0 by design - "declined" is not "absent".
- The bridge's ITH carry overwrote the DIT with a stale copy
(
dit_ITH=1->0); carry REMOVED, DIT is the holder. Thedispatch_pending[]shadow was measured:= 0at every save and REVERTED. nd100xsrc/machine/mfbus_bridge.cis48f06b4plus the THA move only.
Commits, in order¶
nd500x, branch fix-5000:
777924c VWATCH / 3fb4c6a nd500_dit_read_tha / 0987e16 plan: segment-12
traced to THA / 5cad152 non-faulting handler probe + A-segment in copy log /
6cf8b0b plan: trap-path chain / 196c49a plan: ENTT interlock /
46d827f plan: interlock carry ruled out / 952441d CALL/ENT/RET family
aligned with the C# / 53d9008 abort flag honoured where the reference
unwinds.
nd100x: 440ca49 THA load / 48f06b4 THA read placement.
Nothing pushed. Both branches stay local.
How to reproduce a run¶
The pty-driven SINTRAN sessions used here were written to the session
scratchpad, not to the repo (they would carry root-anchored paths). The
sequence each one drives is: ESC / SYSTEM / ND-500 / DEFINE-SWAP-FILE /
PLACE-DOMAIN CPU-STAT / RUN / LIST-ACTIVE-PROCESSES, capturing stderr and the
console separately. docs/INVESTIGATION-TRAPS.md has the three-command
bring-up for this lane.