Skip to content

ND-500 Instruction Documentation Standards

Purpose

This document defines the canonical formatting standards for all ND-500 instruction documentation files generated in /docs/instructions/asm/.


1. Hexadecimal Notation

Standard: Always use 0x prefix (C-style)

✅ CORRECT:

0xFC04
0x00B0
0xFFD0

❌ INCORRECT:

0FC04H   (Norsk Data style - use only when quoting Reference Manual)
FC04H
$FC04    (assembly style)

Rationale: Consistency with instructions.json and modern programming conventions.


2. Mnemonic Format

Standard: {prefix}{register} {mnemonic} {operands}

Examples:

Single-operand instructions:

W1 := B.VAR        ; Load word from local variable
H2 =: R.FIELD      ; Store halfword to record field
BY3 := 0xFF        ; Load byte constant

Multi-operand instructions:

W1 CIND B.INDEX, 1, 10       ; Calculate index with bounds 1-10
H1 ADD W2                    ; Add W2 to H1
F1 * F2                      ; Multiply F1 by F2

No-operand instructions:

RET                ; Return from subroutine
NOOP               ; No operation
HALT               ; Halt CPU

Spacing Rules:

  • One space between prefix-register and mnemonic
  • One space after mnemonic before first operand
  • Comma + space between operands
  • No space before comments (; starts on same line or indented)

3. Addressing Mode Syntax

Standard: Use the canonical names from chapter 8 (sections 8.3-8.16) of the ND-500 Reference Manual. There is no document under docs/ for these yet - the explainer that covered them was removed for ranking the modes by speed, which the manual never does.

Mode Syntax Example
CONSTANT value 42, 0x100, 3.14
CONSTANT_SHORT value:S B.0:S, B.4:S
REGISTER Rn, Wn, Hn, BYn, Fn, Dn W1, H2, F3
LOCAL B.displacement B.8, B.VAR
LOCAL_SHORT B.displacement:S B.0:S, B.1:S
RECORD R.displacement R.4, R.FIELD
RECORD_SHORT R.displacement:S R.0:S
ABSOLUTE address 0x1000, GLOBAL_VAR
LOCAL_INDIRECT IND(B.displacement) IND(B.PTR)
RECORD_INDIRECT IND(R.displacement) IND(R.NEXT)
ABSOLUTE_INDIRECT IND(address) IND(0x2000)
PRE_INDEXED B.disp(Rn) B.ARRAY(W2)
POST_INDEXED B.disp(Rn) B.DATA(H1)
DESCRIPTOR DESC(operand)(Rn) DESC(B.STR)(W1)
ALTERNATIVE_DOMAIN ALT(operand) ALT(B.PARAM)

4. Data Type Prefixes

Standard: Use uppercase prefix names

Prefix Full Name Usage
BI Bit BI1, BI2, BI3, BI4
BY Byte BY1, BY2, BY3, BY4
H Halfword H1, H2, H3, H4
W Word W1, W2, W3, W4
F Float F1, F2, F3, F4
D Double D1, D2, D3, D4
R_N Register/None Instruction has no explicit prefix

Note on R_N: This appears in instructions.json and means the instruction does NOT use a data type prefix (e.g., NOOP, RET, HALT).


5. Instruction File Naming

Standard: Lowercase, underscores for special characters

Rules:

  1. Use mnemonic as base filename
  2. Convert to lowercase
  3. Replace special characters:
    • := → assignto
    • =: → assignfrom
    • b:= → b_assignto
    • r:= → r_assignto
    • + → add
    • - → sub
    • * → mul
    • / → div
  4. Add .md extension

Examples:

Mnemonic Filename
:= assignto.md
=: assignfrom.md
CIND cind.md
ADD add.md
* mul.md
b:= b_assignto.md

6. Markdown File Structure

Standard Template:

# {INSTRUCTION_NAME}

## Overview

**Mnemonic:** {mnemonic}
**Function:** {FunctionName}
**Class:** {CLASS}
**Privilege:** {user|supervisor}

**Format:** {prefix}{register} {mnemonic} {operands}

---

## Description

{Detailed description from Reference Manual}

**Operation:**
```
{pseudo-code or mathematical operation}
```

---

## Variants

Total variants: {N}

| Variant | Opcode | Prefix | Register | Addressing Modes |
|---------|--------|--------|----------|------------------|
| 1/{N} | 0xXXXX | PREFIX | Rn | MODE1, MODE2, ... |
...

---

## Addressing Modes

### Operand 1: {description}

Supported modes:
- **MODE1:** {example}
- **MODE2:** {example}

### Operand 2: {description}
...

---

## Trap Conditions

- **Trap Name (BIT):** {when it occurs}
- ...

---

## Data Status Bits

- **Z (Zero):** {condition}
- **S (Sign):** {condition}
- **O (Overflow):** {condition}
- **K (Flag):** {condition}

---

## Examples

### Example 1: {description}

```assembly
{code}
```

**Explanation:** {what the code does}

### Example 2: {description}
...

---

## Performance Notes

- **Typical cycles:** {estimate}
- **Best case:** {scenario}
- **Worst case:** {scenario}

---

## Reference Manual

**Section:** {§X.Y}
**Page:** {page number}
**Title:** {section title}

---

## See Also

- [{related instruction 1}]({filename1}.md)
- [{related instruction 2}]({filename2}.md)
- [Trap System](../../ND-500-TRAPS.md)

7. Code Comment Style

Standard: Descriptive comments, aligned at column 40 (or after instruction)

Good Examples:

        W1 := B.VAR             ; Load local variable VAR
        W1 ADD 10               ; Add constant 10
        W1 =: B.RESULT          ; Store result

loop:
        W2 COMP 100             ; Check if W2 < 100
        IF >= GO done           ; Exit loop if W2 >= 100
        W2 ADD 1                ; Increment counter
        GO loop                 ; Continue loop

done:
        RET                     ; Return from subroutine

Bad Examples:

; Don't do this
W1 := B.VAR;load var           ; No space before comment
W1ADD 10                        ; Missing space after W1
W1=:B.RESULT                    ; No spaces around =:

8. Operand Naming Conventions

Standard: Use descriptive symbolic names

Variable Names:

  • Use UPPER_CASE for symbolic constants
  • Use PascalCase or snake_case for variables
  • Prefix local vars with nothing (implied B register)
  • Prefix record fields with nothing (implied R register)

Examples:

; Constants
MAX_SIZE = 1000
PI = 3.14159

; Local variables (B register)
        W1 := B.counter         ; Local variable
        W2 := B.array_size      ; Another local

; Record fields (R register)
        H1 := R.age             ; Record field
        W2 := R.salary          ; Another field

; Absolute addresses
        W3 := GLOBAL_COUNTER    ; Global variable

9. Cross-Reference Format

Standard: Markdown links, relative paths

See [LIND instruction](lind.md) for loading indexes.

For more on addressing, see the ND-500 Reference Manual, chapter 8.

External References:

**Reference Manual:** §15.9 Calculate Index (page 262)

**Trap Documentation:** See [Trap System](../../ND-500-TRAPS.md)

10. Variant Numbering

Standard: {current}/{total} format

Examples:

Variant 1/20
Variant 13/20
Variant 20/20

Always:

  • Use 1-based indexing (not 0-based)
  • Include total count
  • Update if variants change

11. Opcode Presentation

Standard: Show hex, binary, and decimal

Format:

Variant Opcode (Hex) Opcode (Binary) Opcode (Decimal)
1/4 0xFC04 1111_1100_0000_0100 64516
2/4 0xFC05 1111_1100_0000_0101 64517

Binary format: Use underscores for nibble separation (every 4 bits)


12. Ambiguity Resolutions

R_N Prefix

Meaning: "Register/None" - instruction has NO explicit data type prefix

Usage in docs:

**Prefixes:** NONE (R_N in JSON means no prefix required)

POST_INDEXED vs PRE_INDEXED

Clarification:

  • PRE_INDEXED: Index calculated BEFORE base: BASE + INDEX
  • POST_INDEXED: Index calculated AFTER base: (BASE) + INDEX

Both can apply to LOCAL (B) and RECORD (R) addressing.

SHORT Forms

Meaning: Compact encoding with word-unit displacements

Example:

  • B.0:S = B register + 0 words = B + 0 bytes
  • B.1:S = B register + 1 word = B + 4 bytes
  • B.2:S = B register + 2 words = B + 8 bytes

Validation Checklist

Before committing a new instruction file, verify:

  • [ ] Hex notation uses 0x prefix
  • [ ] Mnemonic format is {prefix}{register} {mnemonic} {operands}
  • [ ] All addressing modes use canonical names
  • [ ] Code examples have descriptive comments
  • [ ] Variant numbering is X/Y format
  • [ ] Cross-references use relative Markdown links
  • [ ] File named correctly (lowercase, special chars replaced)
  • [ ] All required sections present (see template)
  • [ ] UTF-8 encoding (no BOM)

Version: 1.0 Last Updated: 2025-11-08 Status: APPROVED