FECLOS (IF) NDIX FECLOS (IF)¶
NAME¶
feclos - close a sub-device.
SYNOPSIS¶
#define FE_CLOS 0x4
feclos(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct rpk {
short completion;
};
GENERIC DEVICES¶
| Code | Device |
|---|---|
| 1 | disk |
| 2 | tape |
| 3 | terminal-in |
| 4 | terminal-out |
| 5 | invalid(clock) |
| 6 | invalid |
| 7 | xmsg |
| 8 | invalid(si) |
SUB-DEVICES¶
Any subdevice codes corresponding to already open sub-devices on the generic device are allowed. All other sub-devices cause an error.
VALID QUALIFIERS¶
synchronous and asynchronous.
DESCRIPTION¶
The feclose monitor call closes a currently open sub-device. After this call has been issued no more I/O may be performed until the sub-device has been opened again. The ND-100 should cause all pending I/O to be completed before returning from this call.
COMMAND PACKET FORMAT¶
None.
RESPONSE PACKET FORMAT¶
Standard (see § 4.1.3).
NOTES¶
This call is always used synchronously.
Page 2¶
FEDCTL(IF)¶
NAME¶
fedctl - control an open sub-device.
SYNOPSIS¶
#define FE_DCTL 0x9
fedctl(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk_intr {
/* empty */
};
struct cpk_disk {
short operation;
short format_no;
};
struct cpk_tape {
short operation;
short parameter;
};
struct cpk_term {
short operation;
short parameter;
};
struct cpk_xmsg {
short request;
short parameter;
};
struct rpk_xxx { /* terminal, si */
short completion;
};
struct rpk_disk {
short completion;
short status;
};
struct rpk_tape {
short completion;
short status;
short ops;
};
Page 3¶
FEDCTL(IF) NDIX FEDCTL(IF)¶
GENERIC DEVICES¶
- disk
- tape
- terminal-in
- invalid(terminal-out)
- invalid(clock)
- invalid
- xmsg
- software interrupt
SUB-DEVICES¶
Any open sub-devices on the above generic devices.
VALID QUALIFIERS¶
Synchronous or asynchronous. Terminal operations are always synchronous. All others are always asynchronous.
DESCRIPTION¶
The fedctl monitor call is used to perform certain, non I/O, functions. The operation is either synchronous or asynchronous. In asynchronous mode the completion is signalled via an interrupt on the appropriate device.
COMMAND PACKET FORMAT¶
Varies slightly according to the device:
DISK¶
| name | offset/size | meaning |
|---|---|---|
| operation | 0 2 | 1 set floppy format (spec by param) |
| 2 format floppy(80 tracks) | ||
| parameter | 2 2 | format number |
These commands will cause an error return if performed on a non-floppy device. The format-floppy (2) command will cause the format to be done according to the currently set format.
TAPE¶
| name | offset/size | meaning |
|---|---|---|
| operation | 0 2 | 1 forward space n files (specified by param) |
| 2 backward space n files | ||
| 3 forward space n records | ||
| 4 backward space n records | ||
| 5 rewind | ||
| 6 rewind and unload | ||
| 7 get drive h/w status | ||
| 8 write EOF (currently using 0) | ||
| parameter | 2 2 | Optional parameter n if required by func. |
Page 4¶
TERMINAL¶
| name | offset/size | meaning |
|---|---|---|
| operation | 0 2 | 1 Flush output (generic device 4) |
| 2 change baudrate (specified by param). | ||
| 3 change flags (param specifies new flags). | ||
| 4 invalid | ||
| 5 drop dtr | ||
| 6 define xon/xoff characteristics | ||
| (spec by parameter & pchars) | ||
| parameter | 2 2 | Optional parameter as required by func: |
Baudrate¶
#define B0 0
#define B50 0000001
#define B75 0000002
#define B110 0000003
#define B134 0000004
#define B150 0000005
#define B200 0000006
#define B300 0000007
#define B600 0000010
#define B1200 0000011
#define B1800 0000012
#define B2400 0000013
#define B4800 0000014
#define B9600 0000015
#define EXTA 0000016
#define EXTB 0000017
Control Flags¶
#define EVEN 00 (even parity)
#define ODD 01 (odd parity)
#define RAW 02 (raw mode)
Xon/Xoff¶
#define X_RAW 00
#define X_TANDEM 01
#define X_DECCTQ 02
| pchar1 | 4 2 | Optional parameter - xoff character |
|---|---|---|
| pchar2 | 6 2 | Optional parameter - xon character |
Terminal fedctl(if) calls will be issued to the input subdevice only, but will affect both input and output devices, and must always be synchronous. The X_TANDEM parameter is always accompanied by 2 optional characters to specify the xoff character and the xon. The X_DECCTQ parameter is accompanied by one xoff character as in this mode any character acts as an xon character. Due to speed considerations, all flow-control handling must be performed in the ND-100.
XMSG¶
| name | offset/size | meaning |
|---|---|---|
| request | 0 2 | 1 Kick |
| 2 Wait for buffer to have n bytes free | ||
| parameter | 2 2 | number of bytes required by request 2 above. |
SOFTWARE INTERRUPT¶
A fedctl call from this device is used to schedule an interrupt at ipl 4 from the ND-100 on the
[Illegible text]
EN 페이지 3
Page 5¶
RESPONSE PACKET FORMAT¶
Varies slightly according to the device:
DISK, TAPE¶
Standard (see § 4.1.3).
TERMINALS, SOFTWARE INTERRUPT¶
Standard (completion code only).
XMSG¶
None.
Page 6¶
FEERRM(IF) NDIX FEERRM(IF)¶
NAME¶
feerrm – send error code to ND-100
SYNOPSIS¶
#define FE_ERRM 0xE
feerrm(dev, req, req, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk {
short error_code;
};
GENERIC DEVICES¶
Valid on all Generic Devices (even non-existent ones). The Generic device/subdevice combination specifies the device causing the error.
VALID QUALIFIERS¶
synchronous only.
DESCRIPTION¶
The feerrm monitor call is used to send an error code to the ND-100, following the detection of an inconsistency or non-fatal error during ND-100/ND-500 communications. The error is associated with a particular sub-device.
COMMAND PACKET FORMAT¶
| name | offset/size | meaning |
|---|---|---|
| error_code | 0 2 | NDIX Error Code |
RESPONSE PACKET FORMAT¶
Standard (see §4.1.3).
EN 1
Page 7¶
FEEXIT(IF) NDIX FEEXIT(IF)¶
NAME¶
feexit – shutdown the NDIX system.
SYNOPSIS¶
#define FE_EXIT 0xB
feexit(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk {
short s3_how;
long howto, rootdev;
short contigno, pageno, condev;
long crshdev, crshst, crshend;
char message[80];
char bootme[256];
};
GENERIC DEVICES¶
None, ignored.
SUB-DEVICES¶
None, ignored.
VALID QUALIFIERS¶
synchronous, it never returns.
DESCRIPTION¶
The feexit monitor call reverses the effect of the feinit(if) call by shutting down the NDIX system running in the ND-500 processor. According to the value of s3_how, NDIX is either disabled totally or rebooted from the SINTRAN-III file whose pathname is given in bootme.
The number of contiguous pages required by the NDIX kernel may be indicated, if the number previously allocated was not sufficient, and the minimum number of pages that should be allocated for use by NDIX in the initial bitmap. These numbers should be retained and used by the interface in between warm starts.
The values of howto and rootdev should be also stored in a static area, and passed back to NDIX at the next feinit(if) call. This monitor call never returns to the caller.
COMMAND PACKET FORMAT¶
| name | offset/size | meaning |
|---|---|---|
| s3_how | 0 2 | Bit coded field indicating the reboot action to be taken by the ND-100. |
| Bit 0: 0 shutdown completely | ||
| 1 reboot | ||
| 1: reset stored values | ||
| 2: reboot with specified contiguous area | ||
| (not implemented) | ||
| 3: reboot with specified no of xtra pages |
Page 8¶
FEEXIT(IF) NDIX FEEXIT(IF)¶
Crash Dump Procedure¶
- (not implemented)
- 4: take crash dump before reboot
- (not implemented)
| Howto | Description | Value |
|---|---|---|
| 2 | how to reboot NDIX (single/multiuser) | rootdev 6 |
| 4 | NDIX root filesystem device | contigno 10 |
| 2 | no of contig pages required by NDIX (unused) | pageno 12 |
| 2 | min no of pages in first bitmap (unused) | condev 14 |
| 2 | NDIX console minor device | no creshdev 16 |
| 4 | device/subdevice for crash dump (not implemented) | crsht 20 |
| 4 | block offset for start of crash dump | crshend 24 |
| 4 | crash dump must not go beyond this block | message 28 |
| 80 | console message. | bootme 108 256 system file pathname. |
In all cases the null terminated string 'message' should be printed once on the NDIX system console and once on the SINTRAN-III system console. If bit 1 is set in s3_how then NDIX should be rebooted from the image contained in the SINTRAN-III data file whose name is given in the null terminated string 'bootme'. For example 'bootme' might contain the string:
(SYSTEM)VMUNIX
In this case NDIX would be booted from the files (SYSTEM)VMUNIX:PSEG and (SYSTEM)VMUNIX:DSEG, which must be present in the main directory on the SINTRAN-III filesystem. If bit 1 is set then the values of howto and rootdev should be saved in a manner that associates them permanently with the file named in bootme and passed back in the feinit call when the file is booted.
RESPONSE PACKET FORMAT¶
None.
Page 9¶
FEIDEV(IF) NDIX FEIDEV(IF)¶
NAME¶
feidev – initialise a generic device.
SYNOPSIS¶
#define FE_IDEV 0x2
feidev(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk_xxxx {
short ipl;
};
struct cpk_term {
short ipl;
long pparam;
};
struct cpk_xmsg {
short ipl;
long paralist;
};
struct rpk_xxx {
short completion;
short subdevc;
};
struct rpk_terminal {
short completion;
long locdevm;
short remdevc;
};
struct rpk_clock {
short completion;
struct s3_date now; /* the date in SIII format */
};
GENERIC DEVICES¶
| Number | Meaning |
|---|---|
| 1 | disk |
| 2 | tape |
| 3 | terminal input |
| 4 | terminal output |
| 5 | clock |
| 6 | invalid |
| 7 | xmsg |
| 8 | software interrupt |
Page 10¶
FEIDEV(IF) NDIX FEIDEV(IF)¶
SUB-DEVICES¶
None, ignored.
VALID QUALIFIERS¶
synchronous
DESCRIPTION¶
The feidev monitor call is used to initialize a generic device, prior to I/O and before any feopen(if) calls are issued on its subdevices. The monitor call may only be used synchronously.
COMMAND PACKET FORMAT¶
Varies according to the device:
| name | offset/size | meaning |
|---|---|---|
| DISK, TAPE, SI | ||
| ipl | 0/2 | Interrupt priority level for this generic device |
| TERMINAL | | | | ipl | 0/2 | Interrupt priority level for this generic device | | pparam | 2/4 | ND100 address of shared character counters |
| XMSG | | | | ipl | 0/2 | Interrupt priority level for this generic device | | paralist | 2/4 | ND100 address of xmsg parameter list buffer |
RESPONSE PACKET FORMAT¶
Varies according to the device:
| name | offset/size | meaning |
|---|---|---|
| CLOCK | ||
| completion | 0/2 | 0 command completed ok n interface error code |
| now | 2/12 | SINTRAN-III format date (must be GMT) |
| TERMINAL-INPUT | | | | completion | 0/2 | 0 command completed ok n interface error code | | locdevm | 2/4 | 32 bit mask of local devices present. Each bit set on indicates 4 terminal lines physically present. | | remdev | 6/2 | count of remote devices |
| DISK TAPE XMSG | | | | completion | 0/2 | 0 command completed ok n interface error code | | subdevc | 2/2 | count of valid logical subdevices available for use |
Page 11¶
FEIDEV(IF) - NDIX - FEIDEV(IF)¶
If the generic device being initialised is the clock then it will begin interrupting immediately, at 40ms intervals. This differs from the other devices which must be opened using the FE_OPEN call before any I/O can be performed.
Page 12¶
FEINIT(IF) NDIX FEINIT(IF)¶
NAME¶
feinit – system initialisation
SYNOPSIS¶
#define FE_INIT 0x1
feinit(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk {
short ux_vers;
long cxbadd;
long errxcb, errdata;
long intvec;
long errvec;
};
struct rpk {
short completion;
long howto, rootdev;
short condev;
long spst, scont, sndix;
long stext, sdata, sstack, sfree, sbuffer, sphys;
long private;
short cputype, s3_vers;
long sharedseg;
short contigno, pageno;
char booted[256];
};
GENERIC DEVICES¶
Always zero. Ignored.
SUB-DEVICES¶
None, ignored.
VALID QUALIFIERS¶
synchronous
DESCRIPTION¶
Feinit is a monitor call made once at system startup to tell the ND-100 that the NDIX program has been correctly loaded and to pass basic system parameters between NDIX and the SINTRAN-III ND-500 driver. Unlike all the other monitor calls supported by the ND100/NDIX interface the addresses of the response and command packets are ND-500 data segment logical addresses (KVA) and not ND-100 physical addresses. This is necessary because the NDIX kernel does not yet know the extent of the ND-100 private memory and therefore cannot perform the relocation itself. All other monitor calls use ND-100 physical addresses, i.e. they relocate all the ND-500 physical addresses by the value private. The ND-100 should regard the failure of the NDIX program to make an feinit call within a reasonable time (say 10 seconds) as a fatal error. The operation of this call is always synchronous.
EN | 1
Page 13¶
COMMAND PACKET FORMAT¶
| name | offset/size | meaning |
|---|---|---|
| ux_vers | 0 2 | A version number for the NDIX system. |
| cxbadd | 2 4 | ND-500 logical addr interrupt cxb array |
| errcxb | 6 4 | ND-500 logical addr context block for traps |
| errdata | 10 4 | ND-500 logical addr trap data area |
| intvec | 14 4 | ND-500 logical addr of interrupt vector |
| errvec | 18 4 | ND-500 logical addr of fatal trap vector |
RESPONSE PACKET FORMAT¶
| name | offset/size | meaning |
|---|---|---|
| completion | 0 2 | 0 command completed successfully |
| n | interface error code | |
| howto | 2 4 | how to reboot NDIX (passed from previous exit) |
| rootdev | 6 4 | NDIX root filesystem device (passed from exit) |
| condev | 10 2 | NDIX console minor-device no (from exit or LOAD) |
| spst | 12 4 | ND100 phys addr of PST |
| scont | 16 4 | ND100 phys addr of NDIX contig area (ignored) |
| sndix | 20 4 | ND100 phys addr of NDIX process segment (ignored) |
| stext | 24 4 | ND100 phys addr of NDIX program segment |
| sdata | 28 4 | ND100 phys addr of NDIX data segment |
| sstack | 32 4 | ND100 phys addr of NDIX stack segment |
| sfree | 36 4 | ND100 phys addr of start of free memory |
| sbuffer | 40 4 | ND100 phys addr of end of contig area (ignored) |
| sphys | 44 4 | ND100 phys addr of start of non-existent memory |
| private | 48 4 | size of ND-100 private memory in bytes |
| cputype | 52 2 | The ND500 cputype on which system is running |
| s3_vers | 54 2 | SIII version in use |
| sharedseg | 56 4 | ND-100 phys addr of shared segment index page |
| contigno | 60 2 | Length of contiguous area in pages (ignored) |
| pageno | 62 2 | Number of pages in primary bitmap (ignored) |
| booted | 64 256 | system file pathname |
Booted This is a null-terminated string which specifies the name of the SINTRAN-III data file from which the NDIX system is being booted. For example bootme might contain the string:
(SYSTEM)VMUNIX
In this case NDIX would have been booted from the files (SYSTEM)VMUNIX:PSEG and (SYSTEM)VMUNIX:DSEG.
Page 14¶
FEOPEN(IF) NDIX FEOPEN(IF)¶
NAME¶
feopen – open a subdevice for I/O.
SYNOPSIS¶
#define FE_OPEN 0x3
feopen(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk_disk {
short format;
};
struct cpk_xmsg {
long datbuf;
};
struct rpk_disk {
short completion;
long devtype;
long frmsiz;
short secsiz;
};
struct rpk_tape {
short completion;
short status;
};
struct rpk_xxxx {
short completion;
};
GENERIC DEVICES¶
| number | meaning |
|---|---|
| 1 | disk |
| 2 | tape |
| 3 | terminal-in |
| 4 | terminal-out |
| 5 | invalid(clock) |
| 6 | invalid |
| 7 | xmsg |
| 8 | invalid(si) |
SUB-DEVICES¶
Any sub-devices passed back when the generic device was feidev'd are allowed. All other sub-devices cause an error.
Page 15¶
FEOPEN(IF) NDIX FEOPEN(IF)¶
VALID QUALIFIERS¶
Synchronous and asynchronous.
DESCRIPTION¶
The feopen monitor call prepares a sub-device on a previously feidev'd generic device for I/O. The sub-device must be one of those passed back to this feidev call. Until an feopen call has been performed on a sub-device all I/O should be disallowed, following an feopen all I/O requests should be enabled.
For terminal devices configured for hard carrier an asynchronous feopen call is used. The open only succeeds when the carrier is present. Shared terminal devices must also use the asynchronous call, the open succeeds only when the user requests access to NDIX. For other (soft carrier) devices the synchronous call is used on open.
COMMAND PACKET FORMAT¶
DISK¶
| name | offset/size | meaning |
|---|---|---|
| format | 0 4 | Format type for floppy disk. |
XMSG¶
| name | offset/size | meaning |
|---|---|---|
| datbuf | 0 4 | Physical ND-100 address of data buffer |
RESPONSE PACKET FORMAT¶
Standard apart from disk.
DISK¶
| name | offset/size | meaning |
|---|---|---|
| completion | 0 2 | 0 command completed ok |
| n interface error code | ||
| devtype | 2 4 | Code indicating type of disk |
| frmsiz | 6 4 | Size in sectors if code indicated SCSI disk or |
| format number if code indicated floppy disk | ||
| secsiz | 10 2 | unused |
The devsiz parameter allows NDIX to determine the maximum capacity of the disk drive in sectsiz byte blocks, which represent the smallest read or write request size performed by the NDIX disk drivers. The NDIX system assumes that these blocks can be addressed linearly in the range 0 -> devsiz-1.
Page 16¶
FERCON(IF) NDIX FERCON(IF)¶
NAME¶
fercon – synchronous read from system console
SYNOPSIS¶
#define FE_RCON 0x6
fercon(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk {
long physaddr;
};
struct rpk {
short completion;
};
GENERIC DEVICES¶
Only valid on generic device number 3. All other generic devices cause an error.
SUB-DEVICES¶
Unused.
VALID QUALIFIERS¶
Synchronous only.
DESCRIPTION¶
The fercon monitor call is used to read single bytes from the terminal which has been designated the NDIX system console by SINTRAN-III. The operation of this command is always synchronous.
COMMAND PACKET FORMAT¶
| name | offset/size | meaning |
|---|---|---|
| physaddr | 0 / 4 | ND-100 physical address input buffer. |
The input byte should be placed in the least significant eight bits of the input buffer longword. This is identical to the functioning of the INBT Sintran III monitor call.
RESPONSE PACKET FORMAT¶
Standard (completion code only).
Page 17¶
FEREAD(IF) NDIX FEREAD(IF)¶
NAME¶
feread – read data from a sub-device.
SYNOPSIS¶
#define FE_READ 0x5
feread(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk_disk {
long nbytes;
long physaddr;
long devaddr;
};
struct cpk_tape {
long maxbytes;
long physaddr;
};
struct cpk_terminal {
long dummy;
long physaddr;
};
struct rpk_xxxx {
short completion;
short status;
long nbytes;
};
struct rpk_term {
short completion;
long nbytes;
};
GENERIC DEVICES¶
| type | meaning |
|---|---|
| 1 | disk |
| 2 | tape |
| 3 | terminal-in |
| 4 | invalid(terminal-out) |
| 5 | invalid(clock) |
| 6 | invalid |
| 7 | invalid(xmsg) |
| 8 | invalid(si) |
SUB-DEVICES¶
Any open sub-devices are valid, otherwise an error return is generated.
Page 18¶
FEREAD(IF) NDIX FEREAD(IF)¶
VALID QUALIFIERS¶
Asynchronous only.
DESCRIPTION¶
The feread monitor call is used to transfer data between peripherals, attached to the ND-100, and the ND-500 physical memory. A completion interrupt should be generated.
COMMAND PACKET FORMAT¶
DISK¶
| name | offset/size | meaning |
|---|---|---|
| nbytes | 0 4 | Number of bytes to read. |
| physaddr | 4 4 | ND-100 phys address of buffer to be read into. |
| devaddr | 8 4 | Logical 1024 byte block on the disk where |
| the data is to be read from. |
TAPE¶
| name | offset/size | meaning |
|---|---|---|
| maxbytes | 0 4 | Number of bytes to be read from the tape |
| (the expected record size). | ||
| physaddr | 4 4 | ND-100 phys address of buffer to be read into. |
TERMINAL¶
| name | offset/size | meaning |
|---|---|---|
| dummy | 0 4 | unused |
| physaddr | 4 4 | ND-100 phys address of buffer to be read into |
RESPONSE PACKET FORMAT¶
Varies according to the device:
DISK, TAPE¶
| name | offset/size | meaning |
|---|---|---|
| completion | 0 2 | 0 command completed ok |
| n interface error code | ||
| status | 2 4 | h/w status |
| nbytes | 6 4 | The number of bytes read |
TERMINAL¶
| name | offset/size | meaning |
|---|---|---|
| completion | 0 2 | 0 command completed ok |
| n interface error code | ||
| nbytes | 2 4 | The number of bytes read |
Page 19¶
FEWCON(IF) NDIX FEWCON(IF)¶
NAME¶
fewcon – synchronous write to system console
SYNOPSIS¶
#define FE_WCON 0x8
fewcon(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk {
long physaddr;
};
struct rpk {
short completion;
};
GENERIC DEVICES¶
Only valid on generic device number 4. All other generic devices cause an error.
SUB-DEVICES¶
Unused.
VALID QUALIFIERS¶
synchronous only.
DESCRIPTION¶
The fewcon monitor call is used to write single bytes to the terminal which has been designated the NDIX system console by SINTRAN-III. The operation of this command is always synchronous.
COMMAND PACKET FORMAT¶
| name | offset/size | meaning |
|---|---|---|
| physaddr | 0 4 | ND-100 physical address output buffer. |
The ND-100 should write the character, specified in the least significant eight bits of the 32 bit long-word specified by physaddr to the system console. This mirrors the functionality of the OUTBT Sintran III monitor call.
RESPONSE PACKET FORMAT¶
Standard (completion code only).
Page 20¶
FEWRIT(IF) NDIX FEWRIT(IF)¶
NAME¶
fewrit – write data to a sub-device.
SYNOPSIS¶
#define FE_WRIT 0x7
fewrit(dev, req, rpk, cpk)
struct nd5_dev dev;
struct nd5_req req;
struct cpk_disk {
long nbytes;
long physaddr;
long devaddr;
};
struct cpk_tape {
long nbytes;
long physaddr;
};
struct cpk_terminal {
long nbytes;
long physaddr;
};
struct rpk_xxxx {
short completion;
short status;
};
struct rpk_term {
short completion;
};
GENERIC DEVICES¶
| type | meaning |
|---|---|
| 1 | disk |
| 2 | tape |
| 3 | invalid |
| 4 | terminal-out |
| 5 | invalid(clock) |
| 6 | invalid |
| 7 | invalid(xmsg) |
| 8 | invalid(si) |
SUB-DEVICES¶
Any open sub-devices are valid, otherwise an error return is generated.
VALID QUALIFIERS¶
Asynchronous only.
Page 21¶
FEWRIT(IF) NDIX FEWRIT(IF)¶
DESCRIPTION¶
The fewrit monitor call is used to transfer data between peripherals, attached to the ND-100, and the ND-500 physical memory. A completion interrupt should be generated on the appropriate subdevice.
COMMAND PACKET FORMAT¶
| name | offset/size | meaning |
|---|---|---|
| DISK | ||
| nbytes | 0 4 | Number of bytes to write. |
| physaddr | 4 4 | ND-100 physical address of buffer containing data to write. |
| devaddr | 8 4 | Logical 1024 byte block on the disk where the data is to be written to. |
| TAPE | | | | nbytes | 0 4 | The number of bytes to be written to the tape (the record size). | | physaddr| 4 4 | ND-100 physical address of buffer containing data to write. |
| TERMINAL | | | | nbytes | 0 4 | Number of bytes to be written to the terminal. | | physaddr| 4 4 | ND-100 physical address of buffer containing data to write. |
RESPONSE PACKET FORMAT¶
Standard (see §4.1.3)
EN 2