Page 1¶
SINTRAN III - How to order it¶
ND-30.053.1 EN
[Photo: ND logo and perforations]
Page 2¶
SINTRAN III - How to order it¶
ND-30.053.1 EN
Page 3¶
Manual Information¶
This manual is in loose-leaf form for ease of updating. Old pages may be removed and new pages easily inserted if the manual is revised.
The loose leaf form also allows you to place the manual in a ring binder (A) for greater protection and convenience of use. Ring binders with 4 rings corresponding to the holes in the manual may be ordered in two widths, 30 mm and 40 mm. Use the order form below.
The manual may also be placed in a plastic cover (B). This cover is more suitable for manuals of less than 100 pages than for large manuals. Plastic covers may also be ordered below.
_____________________ _____________________
| NORSK DATA A.S | | NORSK DATA A.S |
| | | |
| | | |
| ND | | ND |
|_____________________| |_____________________|
A: Ring Binder B: Plastic Cover
Please send your order to the local ND office or (in Norway) to:
Norsk Data A.S
Graphic Center
P.O. Box 25, Bogerud
0621 Oslo 6, Norway
Order Form¶
I would like to order
- Ring Binders, 30 mm, at nkr 20,- per binder
- Ring Binders, 40 mm, at nkr 25,- per binder
- Plastic Covers at nkr 10,- per cover
Name
...................................................................................................................
Company
...................................................................................................................
Address
...................................................................................................................
...................................................................................................................
City
...................................................................................................................
Page 4¶
NOTICE¶
The information in this document is subject to change without notice. Norsk Data A.S assumes no responsibility for any errors that may appear in this document. Norsk Data A.S assumes no responsibility for the use or reliability of its software on equipment that is not furnished or supported by Norsk Data A.S.
The information described in this document is protected by copyright. It may not be photocopied, reproduced or translated without the prior consent of Norsk Data A.S.
Copyright ©1985 by Norsk Data A.S.
Page 5¶
PRINTING RECORD¶
| Printing | Notes |
|---|---|
| 07/85 | Version 1 |
SINTRAN III How to order it
Publ.No. ND-30.053.1 EN
.. Norsk Data A.S
.. Graphic Center
( .. .) P.O. Box 25, Bogerud
( .. .) 0621 Oslo 6, Norway
(... ..)
Page 6¶
Manual Updates¶
Manuals can be updated in two ways, new versions and revisions. New versions consist of a complete new manual which replaces the old manual. New versions incorporate all revisions since the previous version. Revisions consist of one or more single pages to be merged into the manual by the user, each revised page being listed on the new printing record sent out with the revision. The old printing record should be replaced by the new one.
New versions and revisions are announced in the Customer Support Information (CSI) and can be ordered as described below.
The reader's comments form at the back of this manual can be used both to report errors in the manual and to give an evaluation of the manual. Both detailed and general comments are welcome.
These forms and comments should be sent to:
Documentation Department
Norsk Data A.S
P.O. Box 25, Bogerud
0621 Oslo 6, Norway
Requests for documentation should be sent to the local ND office or (in Norway) to:
Graphic Center
Norsk Data A.S
P.O. Box 25, Bogerud
0621 Oslo 6, Norway
Page 7¶
Preface¶
GENERAL INFORMATION ON THIS MANUAL¶
The intention of this "manual" is to give the reader some hints on how to fill in the SINTRAN III ORDER FORM. It will not give all details, but cover the most important information needed to generate a SINTRAN III that will satisfy the users. Even though this manual is dedicated to the J-version, it may serve as a guide for other versions as well.
The reader should have some basic knowledge of SINTRAN III, software and hardware.
If you cannot find devices or functions on the order form, this information should be written under SOFTWARE-NOTES on page 1.
The normal way of ordering SINTRAN III is like this:
New systems to be delivered: contact the SYSTEM INTEGRATION department that will install your system (in Norway, UK or Germany).
"Old" systems (systems already installed): contact your local ND-support office.
Norsk Data ND-30.053.1 EN
Page 8¶
TABLE OF CONTENTS¶
| Section | Page |
|---|---|
| 1 CUSTOMER INFORMATION | 1 |
| 2 MASS STORAGE | 3 |
| 2.1 DISKS | 3 |
| 2.2 MAG-TAPES | 4 |
| 2.3 FLOPPY-DISKS | 4 |
| 3 TERMINALS | 6 |
| 4 INPUT/OUTPUT DEVICES AND SPOOLING | 9 |
| 4.1 HDLC / MEGALINK | 9 |
| 4.2 PIOC | 10 |
| 4.3 GP1O | 10 |
| 4.4 OCTOBUS | 10 |
| 4.5 MPM 4 | 10 |
| 4.6 BUS EXPANDER | 10 |
| 4.7 X.21 | 10 |
| 4.8 X.25 | 10 |
| 4.9 X.29 | 10 |
| 4.10 SYNCRONOUS MODEMS | 11 |
| 4.11 CAMAC | 11 |
| 4.12 UNIVERSAL DMA / VICOM INTERFACES | 11 |
| 4.13 FAST UDMA/VICOM OPTION FOR ND-500 | 11 |
| 4.14 LINE-PRINTER | 11 |
| 4.15 FUJITSU-PRINTER | 12 |
| 4.16 VERSATEC | 12 |
| 4.17 COSMOS SPOOLING | 12 |
| 4.18 DEVICE NUMBERS FOR SPOOLING | 12 |
| 5 SYSTEM PARAMETERS | 13 |
| 5.1 RT-PROGRAMS | 13 |
| 5.2 SEGMENTS | 14 |
| 5.3 SEMAPHORES | 14 |
| 5.4 INTERNAL DEVICES | 14 |
| 5.5 BATCH PROCESSORS | 14 |
| 5.6 CX-CPU | 15 |
| 5.7 DEVICE BUFFERS | 15 |
| 5.8 SYMBOLIC DEBUGGER | 15 |
| 5.9 FILE ACCESS SEGMENTS | 15 |
| 5.10 CONNECT TO | 16 |
| 5.11 TERMINAL ACCESS DEVICE (TAD) | 16 |
| 5.12 ND-500 | 16 |
Norsk Data ND-30.053.1 EN
Page 9¶
Table of Contents¶
| Section | Page |
|---|---|
| 5.13 NO-500 PROCESSES | 16 |
| 5.14 ACCOUNTING | 16 |
| 5.15 NOT PANEL CLOCK | 16 |
| 5.16 SIBAS | 16 |
| 5.17 REMOTE JOB ENTRIES | 17 |
| 5.17.1 HASP DMA | 17 |
| 5.17.2 IBM | 17 |
| 5.17.3 HONEYWELL BULL | 17 |
| 5.17.4 UNIVAC | 17 |
| 5.17.5 CDC | 17 |
| 5.18 RT COMMON (CORE COMMON) | 17 |
| 5.19 BACKGROUND ALLOCATION SYSTEM | 17 |
| 5.20 LOGGING FUNCTIONS | 18 |
| 5.20.1 SWAP | 18 |
| 5.20.2 DISC ACCESS | 18 |
| 5.20.3 MON CALL | 18 |
| 5.21 SCREEN | 18 |
| 5.22 LAMU | 18 |
| 5.23 READ SEGMENT | 18 |
| 5.24 TPS | 18 |
| 5.25 NORD NET (ND-NET) | 19 |
| 5.26 DIRECT TASK | 19 |
| 5.27 NO OF RT-PROGRAMS TO BE STARTED FROM DIRECT TASK | 19 |
| 5.28 MAG-TAPE FROM DIRECT TASK | 19 |
| 5.29 DIRECT TRANSFER ON MAG-TAPE | 19 |
| 5.30 CONNECT DATAFIELD | 19 |
| 5.31 EXTENDED OPEN FILE TABLE | 19 |
6 ND-NET¶
| Section | Page |
|---|---|
| 6.1 LINE NUMBER | 21 |
| 6.2 CHANNELS | 21 |
| 6.3 FILLING IN ND-NET CHANNELS | 22 |
| 6.4 OVERLAPPING ND-NET VERSUS OTHER DEVICES | 24 |
7 TERMINAL DEVICE NUMBERS¶
| Section | Page |
|---|---|
| 7 | 25 |
8 OVERLAPPING DEVICE NUMBERS¶
| Section | Page |
|---|---|
| 8 | 28 |
Appendix A SINTRAN III ORDER FORM¶
| Section | Page |
|---|---|
| A | 31 |
Norsk Data ND-30.053.1 EN
Page 10¶
SINTRAN III - How to Order It¶
Customer Information¶
The boxes should be filled in as described below. In order to find out to which system and customer the SINTRAN III belongs, one should be very precise when filling in.
+-------------------------------+----------------------+------------------+
| S I N T R A N I I I O R D E R | PAGE 1 |
+-------------------------------+----------------------+------------------+
| CUSTOMER: | CPU NO: | DATE: |
+-------------------------------+----------------------+------------------+
| CUSTOMER REP. : | PHONE: | |
+-------------------------------+----------------------+------------------+
| CUSTOMER NOTES: | MAINT. : |
+-------------------------------+----------------------+------------------+
| | | |
| ISSUED BY: | DUMPED: (1) | LISTING: (2) |
+-------------------------------+----------------------+------------------+
- Customer: Write the name of the company to which this system is delivered.
- CPU no.: The system number must be filled in. It will identify the SINTRAN III later on when the system is going to have a new SINTRAN III.
- Date: This is the date when the order form has been completed.
- Customer rep.: The name of a customer representative to whom one can turn for information if the customer have any specific requirements to SINTRAN III.
- Phone: Here is the telephone-number to the customer.
- Customer notes: The customer's address or other relevant information.
- Maint.: For internal use by the support office. They will make a note if there is a maintenance contract.
Page 11¶
SINTRAN III - How to Order It¶
Customer Information¶
Issued by¶
Write your initials here. If you don't, we will not be able to trace and report back if SINTRAN III becomes too big or ask for any missing information.
Dumped¶
Specify the type of floppy disks to be used for delivery of SINTRAN III:
8means 0.3-Megabyte, 8-inch diskettes.5means 1.2-Megabyte, 5 1/4-inch diskettes.
Listing¶
Specify if you want a listing of SINTRAN III:
Cmeans complete listing of part two (the configuration dependent part).Smeans symbol listing only.Nmeans no listing.Fmeans that the listing will be delivered on floppy disks (the same type as for SINTRAN III itself).Pmeans that the listing will be printed on paper.
You may specify combinations, for example, CF will give you a complete listing on diskettes. Note that if you don't fill in here, new systems will come with a complete listing on floppies, while old systems will get a listing as decided by regional support.
Below is an example of a correctly filled in customer information form.
+-----------------------------+------------------------------------+
| S I N T R A N I I I O R D E R |
+-----------------------------+------------------------------------+
| CUSTOMER: NORSK DATA A/S | CPU NO: 100-1273 DATE: 85.01.31|
| CUSTOMER REP. : PAL VELGAARD| PHONE: 29 54 00 |
| CUSTOMER NOTES: INSTALLED IN SYSTEM-INTEGRATION AT SKULLERUD |
| MAINT. : |
| ISSUED BY: PV | DUMPED: 8 (1) | LISTING: CP (2) |
+-----------------------------+------------------------------------+
Norsk Data ND-30.053.1 EN
Page 12¶
SINTRAN III - How to Order It¶
Mass Storage¶
2. Mass Storage¶
2.1 Disks¶
Please take great care when you decide your disk configuration. There are limits on how to configurate disks, i.e., you cannot put a Phoenix disk (30/60/90MB) on the same controller as a 450MB. They use different types of controllers. A Phoenix disk requires the 10MHZ disk controller, while the 450MB requires the new 15MHZ controller. The old 33 and 66MB disk drives are not handled by the ND-100 disk interface. The 288MB disk is often referred to as 300MB. Winchester and Hawk drives are using two different interfaces, but they have the same device numbers, and must therefore be used on two different controllers.
----------------------------------------
| MASS STORAGE |
----------------------------------------
| AVAILABLE SIZES ON: | 30MB | 70MB | 75MB |
| | | | |
| REMOVABLE PACKS: | 288MB AS: | 288MB R | 288MB R |
| | 230MB R | 280MB R | 3-75MB | 4-70MB R |
| | | | |
| FIXED DRIVES: | 140MB AS: | 140MB | 2-70MB |
| | 150MB AS: | 275MB | |
| | 288MB AS: | 280MB F | 4-70MB F |
| | 450MB AS: | 450MB | 2-225MB | 6-70MB |
----------------------------------------
| PHOENIX: |
----------------------------------------
| | 30MB | 60MB | 90MB |
| UNIT 0 | ........MB | ........MB | ........MB |
| CONTROL 1 | ........MB | ........MB | ........MB |
| CONTROL 2 | ........MB | ........MB | ........MB |
----------------------------------------
| AVAILABLE SIZES ON WINCHESTER DRIVES: |
| 14 16 21 23 45 HAWK: 10 |
----------------------------------------
| UNIT 0 | 1 | 1 |
| CONTROL 1 | ........MB | ........MB |
| CONTROL 2 | ........MB | ........MB |
----------------------------------------
SYSTEM UNIT ON: ...... MB DISK
When you have decided which disk that will be your system disk (the disk that will contain the files "SINTRAN:DATA" and "MACM-AREA:DATA"), write it on the dotted line below UNIT 0 and to the right hand side of CONTROLLER 1. Write it exactly as described above beside "AVAILABLE SIZES ON :" (see also example below). If you have two different controller types on your system, e.g., 75MB and 21MB, you can put both on UNIT 0 - CONTROLLER 1 (they have different device numbers). Remember then to identify your system disk by writing the correct disk size in the bottom right hand box called "SYSTEM UNIT ON: ...... MB DISK".
Norsk Data ND-30.053.1 EN
Page 13¶
SINTRAN III - HOW TO ORDER IT¶
MASS STORAGE¶
2.2 MAG-TAPES¶
| CONTR/UNIT | MAG-TAPES |
|---|---|
| HP | |
| 1/ | |
| 2/ |
The mag-tape interface for HP has the same device number as PERTEC, CIPHER and STC. In fact, PERTEC and CIPHER are using the same interface. If you are going to use more than one make of mag-tapes, you must define them on separate controllers (see example below).
2.3 FLOPPY-DISKS¶
-------------
| FLOPPY DISK |
| SMALL | BIG |
| | |
-------------
When it comes to floppy disks, you have to know which kind of interface you have in the system. The old "floppy + 4 terminals" interface is referred to as "SMALL FLOPPY", and all the new DMA-interfaces (even if it is a single-side/single-density 8" or a 5 1/4" drive) are referred to as "BIG FLOPPY". The interfaces have the same device numbers.
Note that your "system-floppy" (the one you use for stand-alone programs) must always be on controller 1/unit 0.
Norsk Data ND-30.053.1 EN
Page 14¶
SINTRAN III - HOW TO ORDER IT¶
MASS STORAGE¶
Below is an example of a correctly filled-in MASS STORAGE order.
+------------------------------------------------------+
| MASS STORAGE |
| |
| AVAILABLE SIZES ON: REMOVABLE PACKS: 38MB 70MB 75MB |
| 280MB AS: 225MB R 280MB R 3-75MB 4-70MB R |
| FIXED DRIVES: 140MB AS: 140MB 2-70MB |
| 150MB AS: 2-75MB |
| 280MB AS: 280MB F 4-70MB F |
| 450MB AS: 450MB 2-225MB R 6-70MB |
| PHOENIX: 30MB 60MB 90MB |
+------------------------------------------------------+
| UNIT 0 1 2 3 |
| CONTROL 1 ..6-70. MB ..4-70. MB R .......MB .......MB |
| CONTROL 2 ......70. MB ..288. MB F ..288. MB R .......MB |
+------------------------------------------------------+
| AVAILABLE SIZES ON WINCHESTER DRIVES: 14 16 21 23 45 HAWK: 10 |
+---------------------------------------------------------------+
| UNIT 0 1 |
| CONTROL 1 ......45. MB ........MB |
| CONTROL 2 ......10. MB ........MB |
+---------------------------------------------------------------+
| CONTR/UNIT | MAG-TAPES | FLOPPY DISK |
| | HP PERT | CIPHER STC SMALL, BIG |
| 1/ | 2 | 4 1 2 |
| 2/ | 2 |
+---------------------------------------------------------------+
+------------------------------+
| SYSTEM UNIT ON: .6-70. MB DISK |
+------------------------------+
Norsk Data ND-30.053.1 EN
Page 15¶
SINTRAN III - HOW TO ORDER IT¶
TERMINALS¶
3. TERMINALS¶
| TERMINALS (3) | |---------------|--------------------------------------------------------------------------| | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | | B | | | | | | | | | | | | | | | | | | | | | | | | | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | | | | | | | | | | | | | | | | | | | | | | | | | | | 49 | 50 | 51 | 52 | 53 | 54 | 55 | 56 | 57 | 58 | 59 | 60 | 61 | 62 | 63 | 64 | 65 | 66 | 67 | 68 | 69 | 70 | 71 | 72 | | 4 | | | | | | | | | | | | | | | | | | | | | | | | | 73 | 74 | 75 | 76 | 77 | 78 | 79 | 80 | 81 | 82 | 83 | 84 | 85 | 86 | 87 | 88 | 89 | 90 | 91 | 92 | 93 | 94 | 95 | 96 | | | | | | | | | | | | | | | | | | | | | | | | | | | 97 | 98 | 99 | 100| 101| 102| 103| 104| 105| 106| 107| 108| 109| 110| 111| 112| 113| 114| 115| 116| 117| 118| 119| | | | | | | | | | | | | | | | | | | | | | | | | | | | 121| 122| 123| 124| 125| 126| 127| 128| | | R | B | | | | | | | |
We have two standard terminal interfaces, the 8-term. and the 4-term. The 8-term. is divided into two groups of 4. Device numbers for each four-group are set by thumbwheels. Terminal number 1 will always be present, as this is the console.
This means that normally the first terminal on your system should be set on terminal number 5. Terminals 2, 3 and 4 may be used if the system is using some of the old Nord-10 interfaces.
The following letters must be used as described below:
- B:
"B" means terminal with background. (This is the normal way of using a terminal.)
- R:
"R" means terminal without background. This is used when the terminal is used for RT-programs only, or if "Background Allocation System" is ordered. See chapter 5 "SYSTEM PARAMETERS".
- S:
"S" means printer terminal with spooling.
You may put an "S" on terminal 2, 3 and 4. This is often done if the system is going to have printers in the future, but the customer does not know where he wants to have them connected. By using "SINTRAN-SERVICE-PROGRAM" the spooling can be moved to another output. That output must however be known by SINTRAN III, i.e., another letter must be in that position when you look at the order form.
Norsk Data ND-30.053.1 EN
Page 16¶
SINTRAN III - How to Order It¶
Terminals¶
If you want to alternate between printer output and terminal output, you may write a "B" in the box for your terminal number and under "DEVICE NUMBERS FOR SPOOLING" on page 2 of the order form, you can write that terminal's octal device number. By using "SINTRAN-SERVICE-PROGRAM" you can then remove or insert the background program.
- P :¶
"P" means printer terminal without spooling.
- T :¶
"T" means text editing terminal. The first should be on terminal 16, the second on 15, and so on down to terminal number 2.
- F :¶
"F" means photosetter. The first should be on terminal 31, the second on 30 and the last on 29.
- H :¶
"H" means Harris photosetter. The first should be on terminal 30 and the second on 29.
- G :¶
"G" means Graf cassette. The first should be on terminal 27 and the second on terminal 28.
- X :¶
"X" means ND-net on async-modem output or machine-machine communication. The first line should be on terminal 16, the second on terminal 15 and so on down to terminal 8. On page 2, you must write an "X" in the box "ASYNC" "LINE NO. 1" for terminal 16, in "LINE NO. 2" for terminal 15 and so on.
- Terminals 127 and 128.¶
Terminal 127 is as standard "R" and terminal 128 is "B". This is for patching in the code for "TELEFIX". Please note that you have to have the new 8-terminal interface if you are going to use terminals from 65 and upwards. There are several overlapping device numbers between terminals and HDLC. See chapter 8 ("OVERLAPPING DEVICE NUMBERS").
Norsk Data ND-30.053.1 EN
Page 17¶
SINTRAN III - How to Order It¶
Terminals¶
Below is an example of a correctly filled-in order for TERMINALS.
| TERMINALS (3) |
|---|
| 1 |
| B |
| 25 |
| 49 |
| 73 |
| 97 |
| 121 |
Norsk Data ND-30.053.1 EN
Page 18¶
SINTRAN III - HOW TO ORDER IT¶
INPUT/OUTPUT DEVICES AND SPOOLING¶
4. INPUT/OUTPUT DEVICES AND SPOOLING¶
| INPUT/OUTPUT DEVICES AND SPOOLING |
|---|
| HDLC DMA DRIVER / SYNC. MOD. HDLC (H/S) (4) PIOC GPIB OCTOBUS MPM-4 BUS EXPANDER |
| 1 |
| X.21 | X.25 | X.29 | SYNCRONOUS MODEMS (4) |
|---|---|---|---|
| 1-8 | 1 |
| CAMAC | UNIVERSAL DMA / VICOM INTERFACES (D / V) | FAST UDMA/VICOM OPT. FOR ND-500 |
|---|---|---|
| 1 | 2 | 3 |
| NE- VT/ER/VERSAT EC COSMOS INTER DMA I/O SPOOLING | DEVICE NUMBER FOR SPOOLING (5) |
|---|---|
| 1 | 2 |
4.1 HDLC / MEGALINK¶
The HDLC interface is treated in two different ways by SINTRAN III. One is the DMA and the other is I/O. The hardware is the same, software decides if you must use DMA or I/O (sync. mod.). Seen from SINTRAN III, both HDLC-DMA and MEGALINK is the same interface, and you order them both as HDLC.
To separate them on the order form, you must write "H" for HDLC-DMA/MEGALINK and "S" for HDLC-Sync modem.
In general terms it means that if you are going to communicate with another ND-system, you must use the DMA-function. That is, even if you are going to use X-message on a synchronous line, X.21, X.25 or X.29, you must use the DMA-function. It is the connection on the cabinet's backpanel that will separate the link and the sync function now. Link is machine-machine communication without modem, sync is communication via modem.
MEGALINK can only run directly machine-machine, i.e., you cannot put a modem in between.
If you are communicating with IBM or CDC or other makes, you must use I/O (sync. mod.). HASP DMA is the only exception.
In order to find out which function to use, you have to look into the PO-sheets of the software that is going to be used on the system. The maximum number of HDLC-DMA/MEGALINKs on one system is 32. For HDLC-Sync modem it is 6, and they must be from 1 to 6.
If you are using HDLC both for ND-net and other communication, take care not to use the same HDLC device number. I.e., if you have X-message on HDLC number 1, you must put ND-net on everything but "LINE NO 1".
Some device numbers on terminals and HDLC will overlap. In chapter 8 ("OVERLAPPING DEVICE NUMBERS") you will find the HDLC and terminals you cannot have simultaneously in the same system.
Norsk Data ND-30.053.1 EN
Page 19¶
SINTRAN III - HOW TO ORDER IT¶
INPUT/OUTPUT DEVICES AND SPOOLING¶
4.2 PIOC¶
Fill in the number of PIOCs in the system. PIOCs have no overlapping device numbers.
4.3 GPIB¶
Fill in the number of GPIBs in the system. GPIBs have no overlapping device numbers.
4.4 OCTOBUS¶
Fill in the number of OCTOBUS'es in the system. OCTOBUS'es have no overlapping device numbers.
4.5 MPM 4¶
If the system has MPM 4, you should fill in this box with an "X". It is not necessary to fill in for Bus Expander. For the MPM 5 there is no box to fill in.
4.6 BUS EXPANDER¶
Fill in the number of Bus Expanders in the system. Normally it is minimum 2, one for the one in the A-crate and one for the B-crate. If there is a C-crate you write 3 in the box.
4.7 X.21¶
Fill in the number of lines the system is going to use. X.21 must have an HDLC-DMA. The TPS monitor call is not necessary to fill in, it will be generated automatically.
4.8 X.25¶
Fill in with an "X" if the system is going to use X.25, and at least one HDLC-DMA. The TPS monitor call will be generated automatically.
4.9 X.29¶
Fill in with an "X" if the system is going to have X.29, and at least one HDLC-DMA. The rest of the requirements will be generated automatically.
Norsk Data ND-30.053.1 EN
Page 20¶
SINTRAN III - HOW TO ORDER IT¶
INPUT/OUTPUT DEVICES AND SPOOLING¶
4.10 SYNCRONOUS MODEMS¶
Fill in the number of modems in the system, but not those which are going to be used by the ND-net (they must be filled in on page 2). Sync. modem no. 1 will overlap with ND-net sync. modem no. 6, sync. modem no. 2 will overlap with ND-net sync. modem no. 5 and so on up to sync. modem no. 6. See also chapter 8 ("OVERLAPPING DEVICE NUMBERS").
4.11 CAMAC¶
Fill in the number of CAMAC crates the system is going to communicate with. The maximum number is 16.
4.12 UNIVERSAL DMA / VICOM INTERFACES¶
Fill in the number of interfaces in the system, and the way you want them configured. For UNIVERSAL DMA you must write "D", and for VICOM you must write "V".
4.13 FAST UDMA/VICOM OPTION FOR ND-500¶
This is a monitor call to speed up the use of UDMA/VICOM when using it from the ND-500.
4.14 LINE-PRINTER¶
Fill in the number of printer interfaces using parallel-byte interface, i.e., the 1000/600 l.p.m. printers and Terminet (ND-426). The spooling device numbers for these printers are:
No 1) 5
No 2) 15
No 3) 1014
No 4) 1015
Note that device numbers will overlap with VERSATEC I/O.
4.15 FUJITSU-PRINTER¶
This printer is using a new DMA interface. It is using the same device numbers for spooling as a line printer, see above. In order to have them generated, write which of the printers you want under "SOFTWARE NOTES" in the bottom right hand corner of page 1. Write the correct spooling device number on page 2.
Norsk Data ND-30.053.1 EN
Page 21¶
SINTRAN III - HOW TO ORDER IT¶
INPUT/OUTPUT DEVICES AND SPOOLING¶
4.16 VERSATEC¶
There are two ways of interfacing the VERSATEC printers. One is DMA and the other is I/O. The system can have two DMA interfaces with spooling device numbers:
- No 1) 22
- No 2) 23
If I/O interfaces are used, they have the same device numbers as the line printers mentioned above.
4.17 COSMOS SPOOLING¶
Fill in with an "X" if the system is going to have COSMOS Spooling in conjunction with COSMOS communication. This function should always be present in systems with COSMOS.
4.18 DEVICE NUMBERS FOR SPOOLING¶
All terminals can be used as printer interfaces (see TERMINALS). The octal device numbers should be filled in here. In chapter 7 ('TERMINAL DEVICE NUMBERS') you will find the octal and decimal device numbers for all terminals.
Below is an example of a correctly filled-in order for INPUT/OUTPUT DEVICES.
────────────────────────────────────────────────────────────────────────────
| INPUT/OUTPUT DEVICES AND SPOOLING |
|───────────────────────────────────────────────────────────────────────────|
| HDLC DMA DRIVER / SYNC. MOD. HDLC (H/S) (4) | PIOC | GPIB | OCTOBUS | |
| 1 2 3 4 5 6 7 8 9 10 11 12 | 1-8 | 1-4 | 1-4 | |
|───────────────────────────────────────────────────────────────────────────|
| H S | 1 | 1 | 1 | X |
|─────────────────────────────────────────────┼───────┴───────┴────────┴───|
| X.21 X.25 X.29 | SYNCRONOUS MODEMS (4) |
| 1-8 1 2 3 4 5 6 7 8 9 10 11 | 1 2 1 2 3 4 5 6 7 |
|─────────────────────────────────────────────┼─────────────────────────────|
| 1 X X X X X | |
|───────────────────────────────────────────────────────────────────────────|
| CAMAC | UNIVERSAL DMA / VICOM INTERFACES |
| | (D / V) |
| 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | | FAST UDMA/VICOM |
| | D V | OPT. FOR ND-500 |
|───────────────────────────────────────────────────────────────────────────────|
| LINE- VERSATEC COSMOS | DEVICE NUMBER FOR SPOOLING (5) |
|PRINTER DMA I/O SPOOLING | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 X |
|───────────────────────────────────────────────────────────────────────────────|
| 1 1 X | 5 22 15 11 44 |
────────────────────────────────────────────────────────────────────────────
As you can see above, the line printer and VERSATEC has got separate spooling device numbers, 5 and 15. It is now hardware that will decide which device number is going to be used by which printer.
There are two additional device numbers for spooling, 11 and 44. These are written for user convenience in order to show from page 1 TERMINALS that the spooling device numbers are 11 for terminal 2 and 44 for terminal 5.
Norsk Data ND-30.053.1 EN
Page 22¶
SINTRAN III - HOW TO ORDER IT¶
SYSTEM PARAMETERS¶
5. SYSTEM PARAMETERS¶
| SYSTEM PARAMETERS |
|---|
| RT |
| -50 |
| SYMB. DEBUG. |
| ACCOUNTING RT |
| HASP |
| LOGGING FUNCTIONS |
| SWAP DISC ACCESS |
| T FROM |
The system parameters are very dependent on the use of the system. Customer written programs, software delivered from ND and the use of this software will decide which and perhaps how many of each function to generate.
5.1 RT-PROGRAMS¶
Fill in the number of extra RT-programs required. The system will have generated the system-required RT-programs automatically. That means you have to calculate only the need of RT-programs for own purpose, like loading SIBAS and so on. You have to look into the PD-sheets of the software you are going to use in order to find the exact number required. However, if you don't fill in, you will automatically get 50 extra.
Norsk Data ND-30.053.1 EN
Page 23¶
5.2 SEGMENTS¶
As for the RT-programs, just write the number of extra segments needed. The maximum number of segments SINTRAN III can have is 255. Below you will find the list telling you how many segments different functions use.
| Function | Segments |
|---|---|
| System in general | 33 |
| - ND-500 and XMSG is included | |
| Terminal | 2 |
| Batch-processor | 2 |
| ND-500 process | 2 |
| Terminal access device (TAD) | 2 |
| File access segment | 1 |
| Debugging function | 1 |
| - Addition for each debug terminal | 1 |
| Transaction processing system (TPS) | 31 |
| - Transaction processing terminal (TPT) | 2 |
| Common spooling segment | 1 |
| - Addition for each spooling process | 1 |
| Each ND-net channel | 1 |
| Each ND-net background | 3 |
If nothing is written, the system will be generated with 75 extra segments. You may also write "MAX". Then you will get as many extra segments as possible.
5.3 SEMAPHORES¶
Fill in the number of semaphores the system will need. You can have 5, 10, 20, 30, 40 or 50. The default value is 5. Semaphores are used for simple timing between programs. Refer to SINTRAN III Real Time Guide.
5.4 INTERNAL DEVICES¶
There are two different types of internal devices, one character (byte) oriented, and one block oriented. The character oriented internal devices can be ordered from 1 up to 32, default value is 2. The block oriented internal devices can be ordered from 1 up to 5. The default value is 0. Internal devices are used for information transfer between programs. Character oriented internal devices will transfer information byte by byte, while block oriented internal devices will transfer up to one page (2048 bytes). Refer to SINTRAN III Real Time Guide.
5.5 BATCH PROCESSORS¶
Fill in the number of batch-processors you need. The maximum number is 10. Default value is 1. Remember to add one if the system is going to use "ACCESS".
Norsk Data ND-30.053.1 EN
Page 24¶
SINTRAN III - HOW TO ORDER IT¶
SYSTEM PARAMETERS¶
5.6 CX-CPU¶
If the system has got a CX-CPU, you may write an "X" here. SINTRAN III will then be generated in a different way, enabling the system to contain more devices.
If the system is an ND-500 system, you must have a CX-CPU. SINTRAN III will not run if you don’t have it.
If the system has a CX-CPU, it can without any difficulties run a standard SINTRAN III/VSE.
5.7 DEVICE BUFFERS¶
The default number of device buffers are 20. This will normally be sufficient to cover most systems. It may also be reduced if you have problems with space in SINTRAN III. Calculate the number of device buffers the system needs by using the table below:
| Device | Buffers Needed |
|---|---|
| Each disk interface needs | 1 |
| Each floppy interface needs | 1 |
| Each mag-tape drive needs | 1 |
| Each spooling process needs | 1 |
The device buffers act as a kind of "cache" in memory. That means that the more device buffers you generate, the faster the system will work. The maximum number is 64.
Remember that each device buffer will require one page in memory. You should on small systems (with less than 1.0 MB memory) not have more than 20, as the number of pages for swapping will be insufficient and reduce performance.
5.8 SYMBOLIC DEBUGGER¶
Fill in the number of terminals that is expected to run debugging simultaneously. The symbolic debugger function is not connected to any particular terminal, but is picked out of a pool.
This is a facility that will help programmers to debug their programs written in, e.g., FORTRAN and a few other languages. Not all languages have this option.
This covers the debugging function in the ND-100. The ND-500 have this function as standard.
5.9 FILE ACCESS SEGMENTS¶
Fill in the number of segments that will be used.
File access segments will be used when using BACKUP-SYSTEM from a remote computer. The number required is difficult to forecast. It depends on how many users will use this facility simultaneously. The segments are not released after use until the user logs out.
Norsk Data ND-30.053.1 EN
Page 25¶
SINTRAN III - HOW TO ORDER IT¶
SYSTEM PARAMETERS¶
5.10 CONNECT TO¶
Fill in with an "X".
This will enable users to connect to other systems.
5.11 TERMINAL ACCESS DEVICE (TAD)¶
Fill in the number of TADs the system shall have. Maximum is 96.
A TAD is the background for users on this system logging in from remote computers.
5.12 ND-500¶
Fill in an "X" if the system is an ND-500 system.
Under "Software notes" on page 1, you may write the number of ND-500's if the system consists of more than one ND-500. Maximum is 8.
5.13 ND-500 PROCESSES¶
Fill in the number you want to have on the system. The maximum number that can be generated is 62. The ND-500 may handle up to 64, but 2 must be reserved for the ND-500 itself.
If nothing is filled in, you will have default 10.
5.14 ACCOUNTING¶
Fill in with an "X" if you want to keep accounting of RT-programs and/or I/O.
Background accounting is always present.
5.15 NOT PANEL CLOCK¶
If the system has got no panel clock, you may fill in an "X" here. The system must, however, always be updated (SINTRAN III command: ∂UPDAT) after every restart.
5.16 SIBAS¶
Fill in an "X" under the number of SIBAS'es that will run simultaneously on the system. It will cover both ND-100 and ND-500 SIBAS.
Norsk Data ND-30.053.1 EN
Page 26¶
SINTRAN III - HOW TO ORDER IT¶
SYSTEM PARAMETERS¶
5.17 REMOTE JOB ENTRIES¶
5.17.1 HASP DMA¶
Fill in the number of HASP DMA interfaces the system has. Maximum is 6.
It is not necessary to generate the standard HDLC DMA. HASP DMA will overlap with several other interfaces, see chapter 8 ('OVERLAPPING DEVICE-NUBERS').
5.17.2 IBM¶
If the system is going to communicate with an IBM system over a synchronous modem, fill in an "X" here.
5.17.3 HONEYWELL BULL¶
If the system is going to communicate with an HONEYWELL BULL system over a synchronous modem, fill in an "X" here.
5.17.4 UNIVAC¶
If the system is going to communicate with an UNIVAC system over a synchronous modem, fill in an "X" here.
5.17.5 CDC¶
If the system is going to communicate with an CDC system over a synchronous modem, fill in an "X" here.
5.18 RT COMMON (CORE COMMON)¶
Fill in the number of pages you want for RT COMMON. Default is 0.
5.19 BACKGROUND ALLOCATION SYSTEM¶
The intention of this system is to give the customer the possibility to connect up to 128 terminals to the system. However, all terminals cannot be used simultaneously because of the limited number of segments. By using BACKGROUND ALLOCATION SYSTEM one can connect all terminals, but only a limited number are able to log on simultaneously. That limited number is written below "NO OF BACK" and an "X" below the arrow "BACKGR. ALLOC". All terminals and TAOs will now take a background from a pool. When there are no more backgrounds available, no more users can enter. There is also a timeout function which automatically can log out terminals that have been passive for a predecided period.
NOTE: The console and batches will always have fixed backgrounds.
Norsk Data ND-30.053.1 EN
Page 27¶
SINTRAN III - HOW TO ORDER IT SYSTEM PARAMETERS¶
5.20 LOGGING FUNCTIONS¶
5.20.1 SWAP¶
This is a standard function in SINTRAN III.
5.20.2 DISC ACCESS¶
This is a standard function in SINTRAN III.
5.20.3 MON CALL¶
This is a standard function in SINTRAN III.
5.21 SREEN¶
Fill in with an "X" if you want this monitor call.
SREEN automatically writes all pages belonging to shadow segment (current segment) which have been modified, back to the segment file before the reentrant segment is fetched. Refer to the SINTRAN III Reference Manual.
5.22 LAMU¶
Fill in with an "X" if you want LAMUs.
A LAMU is a limited physically and virtually contiguous address area in the SINTRAN III systems. LAMUs are intended to be an extension to the segment structure. They make it possible for RT-programs and background processes to address more space than covered by the available 3 segments. LAMUs can be shared by several RT-programs or CPUs. Refer to the SINTRAN III System Supervisor manual.
5.23 READ SEGMENT¶
Fill in with an "X" if you want to have read segment. It is automatically generated on ND-500 systems.
The monitor call READ SEGMENT will read the contents of a segment table entry to the user's memory. Refer to the SINTRAN III Reference Manual, monitor call 53.
5.24 TPS¶
Fill in the number of terminals that will run TPS.
Norsk Data NO-30.053.1 EN
Page 28¶
SINTRAN III - HOW TO ORDER IT¶
SYSTEM PARAMETERS¶
5.25 NORD NET (ND-NET)¶
See chapter 6 ("ND-NET").
5.26 DIRECT TASK¶
Fill in with an "X" if you want direct task.
Direct task is a routine executing on one of the free interrupt levels, independent of the operating system. Refer to the SINTRAN III Real Time Guide.
5.27 NO OF RT-PROGRAMS TO BE STARTED FROM DIRECT TASK¶
Fill in the number of RT-programs to be started. Refer to the SINTRAN III Real Time Guide.
5.28 MAG-TAPE FROM DIRECT TASK¶
Fill in with an "X" if this function is wanted.
5.29 DIRECT TRANSFER ON MAG-TAPE¶
Fill in with an "X" if this function is wanted.
Direct transfer on mag-tape is a function that will transfer data from memory directly to the mag-tape interface not using the device buffers.
5.30 CONNECT DATAFIELD¶
Fill in the number of fields wanted.
These data fields are connected to interfaces used in direct tasks.
5.31 EXTENDED OPEN FILE TABLE¶
Fill in the extra number of tables wanted.
If all files are accessed sequentially, the maximum number is 13. If all files are accessed randomly, the number is 28. Refer to SINTRAN III Reference Manual. For each table added, you will increase the number by 13 or 28. (This function requires very much space in SINTRAN III.)
Norsk Data ND-30.053.1 EN
Page 29¶
SINTRAN III - HOW TO ORDER IT¶
SYSTEM PARAMETERS¶
Below is an example of a correctly filled-in order for SYSTEM PARAMETERS.
| RT PROG. | SEGM. CHAR. | SEMA- CHAR. | INTERN. DEVICE BLOCK | BATCH PROC. | CX CPU | DEV BUF | SYMB. DEBUG. | FILE ACC. SEGM. | CONN. TO DEVICE | TERM. ACCESS | ND-500 ND-500 PROCESS |
|---|---|---|---|---|---|---|---|---|---|---|---|
| -50-75-5- | -2- | -1- | 1- | -20- | |||||||
| 80 | MAX 10 | 5 | 2 | 5 X | 40 3 | 10 | X 5 | X | 30 |
| ACCOUNTING | NO I RT 1/0 | PANEL CLOCK | SIBAS 1-3 | 1-6 | 1-12 | REMOTE JOB ENTRIES | RT BACKGR. ALLOC | ND-500 COMM | NO OF BACK |
|---|---|---|---|---|---|---|---|---|---|
| X | X | X | 1 | X | X | X | X | 4 | X 10 |
| LOGGING FUNCTIONS SWAP DISC ACCESS | MON CALL | SREEM SEGM | LAMU SEG | READ 6 | TPS NET 7 | NORD | DIRECT TASK | NO. OF RT-PROG FROM DIR. TASK |
|---|---|---|---|---|---|---|---|---|
| X | X | X | X | X 10 | X | X | 2 |
| M-T FROM DIRECT TASK | DIRECT TRANSFER ON M-T | CONNECT DATAFIELD | EXTEND OPEN FILE TABLE |
|---|---|---|---|
| X | X | 20 | 1 |
Norsk Data ND-30.053.1 EN
Page 30¶
NO-NET¶
| LINE NO | ASYNC | SYNC MODEM | HDLC I/O | CHANNELS | ||
|---|---|---|---|---|---|---|
| FULL DPX. | HALF DPX. | DMA | 1 | |||
| 1 | ||||||
| 2 | ||||||
| 3 | ||||||
| 4 | ||||||
| 5 | ||||||
| 6 | ||||||
| 7 | ||||||
| 8 | ||||||
| 9 |
POOL:
6.1 LINE NUMBER¶
On line number you should fill in the appropriate communication line, e.g., ASYNC. If you have used Async on line 1 and you want to have HDLC communication in addition, you must put this one on line 2. Fill in with an "X".
6.2 CHANNELS¶
There are three different types of channels:
- B:
This is the background channel for a remote terminal, i.e., where it comes into this system.
- N:
This is "the way out" for a local terminal to a remote system.
- C:
This has almost the same function as "N" above. The difference between "N" and "C" is that "C" can handle the monitor call "MAGTP". The "C" therefore requires more space in SINTRAN III.
Norsk Data ND-30.053.1 EN
Page 31¶
POOL¶
Fill in the size of the ND-NET buffer pool. Use the table below to find proper size:
| Lines | Channels | Use |
|---|---|---|
| If 1 line with less/equal | 5 | 4 |
| If 1 line with greater than | 5 | 5 |
| If 2 or 3 lines with less/equal | 5 | 5 |
| If 2 or 3 lines with greater than | 5 | 6 |
| If 4 lines with less/equal | 5 | 6 |
| If 4 lines with greater than | 5 | 7 |
| If 5 or 6 lines with less/equal | 5 | 7 |
| If 5 or 6 lines with greater than | 5 | 8 |
| If 7 lines with less/equal | 5 | 8 |
| If 7 lines with greater than | 5 | 9 |
| If 8 or 9 lines | 9 |
6.3 Filling in ND-NET Channels¶
A "B" on the remote system channel 1 must communicate with an "N" or a "C" on channel 1 on the local system. This will make it possible to perform remote login.
For file transfer, one can use "N" at the local system and the same on the remote system. Remember that the channel number has to be the same.
Page 32¶
SINTRAN III - How to Order It¶
ND-NET¶
Below you will find two orders for ND-NET on two systems that are going to communicate with each other.
System A¶
| LINE NO | ASYNC | SYNC MODEM | HDLC | CHANNELS |
|---|---|---|---|---|
| FULL DPX. | DMA | 1 | ||
| HALF DPX. | I/O | |||
| 1 | X | N | ||
| 2 | X | N | ||
| 3 | ||||
| 4 | ||||
| 5 | ||||
| 6 | ||||
| 7 | ||||
| 8 | ||||
| 9 |
POOL: 6
System B¶
| LINE NO | ASYNC | SYNC MODEM | HDLC | CHANNELS |
|---|---|---|---|---|
| FULL DPX. | DMA | 1 | ||
| HALF DPX. | I/O | |||
| 1 | X | B | ||
| 2 | X | B | ||
| 3 | ||||
| 4 | ||||
| 5 | ||||
| 6 | ||||
| 7 | ||||
| 8 |
POOL: 6
Norsk Data ND-30.053.1 EN
Page 33¶
SINTRAN III - HOW TO ORDER IT¶
6.4 Overlapping ND-NET Versus Other Devices¶
ND-NET¶
| LINE NO | ASYNC | SYNC MODEM | H D L C | CHANNELS |
|---|---|---|---|---|
| FULL DPX. | DMA | 1 | ||
| HALF DPX. | I/O | |||
| 1 | *16 | SYNC. MOD. NO. 6 | HDLC 1 | *53,54 |
| 2 | *15 | SYNC. MOD. NO. 5 | HDLC 2 | *55,56 |
| 3 | *14 | SYNC. MOD. NO. 4 | HDLC 3 | *57,58 |
| 4 | *13 | SYNC. MOD. NO. 3 | HDLC 4 | *59,60 |
| 5 | *12 | SYNC. MOD. NO. 2 | HDLC 5 | *61,62 |
| 6 | *11 | SYNC. MOD. NO. 1 | HDLC 6 | *63,64 |
| 7 | *10 | CAMAC1 | ||
| 8 | * 9 | CAMAC2 | ||
| 9 | * 8 | CAMAC3 |
- "*" means terminal number.
Norsk Data ND-30.053.1 EN
Page 34¶
SINTRAN III - How to Order It¶
Terminal Device Numbers¶
7. Terminal Device Numbers¶
| Term.no. | Device | IDENT- | Logical Dev.no. | Back- |
|---|---|---|---|---|
| Oct. Dec. | No. | Code | Oct. Dec. | ground |
| 1 1 | 300 | 120(1) | 1 1 | BAK01 |
| 2 2 | 310 | 121(5) | 11 9 | BAK02 |
| 3 3 | 320 | 122(6) | 42 34 | BAK03 |
| 4 4 | 330 | 123(7) | 43 35 | BAK04 |
| 5 5 | 340 | 44 | 44 36 | BAK05 |
| 6 6 | 350 | 45 | 45 37 | BAK06 |
| 7 7 | 360 | 46 | 46 38 | BAK07 |
| 10 8 | 370 | 47 | 47 39 | BAK08 |
| 11 9 | 1300 | 50 | 60 48 | BAK09 |
| 12 10 | 1310 | 51 | 61 49 | BAK10 |
| 13 11 | 1320 | 52 | 62 50 | BAK11 |
| 14 12 | 1330 | 53 | 63 51 | BAK12 |
| 15 13 | 1340 | 54 | 64 52 | BAK13 |
| 16 14 | 1350 | 55 | 65 53 | BAK14 |
| 17 15 | 1360 | 56 | 66 54 | BAK15 |
| 20 16 | 1370 | 57 | 67 55 | BAK16 |
| 21 17 | 200 | 60 | 7 7 | BAK17 |
| 22 18 | 210 | 61 | 17 15 | BAK18 |
| 23 19 | 220 | 62 | 52 42 | BAK19 |
| 24 20 | 230 | 63 | 53 43 | BAK20 |
| 25 21 | 240 | 64 | 54 44 | BAK21 |
| 26 22 | 250 | 65 | 55 45 | BAK22 |
| 27 23 | 260 | 66 | 56 46 | BAK23 |
| 30 24 | 270 | 67 | 57 47 | BAK24 |
| 31 25 | 1200 | 70 | 70 56 | BAK25 |
| 32 26 | 1210 | 71 | 71 57 | BAK26 |
| 33 27 | 1220 | 72 | 72 58 | BAK27 |
| 34 28 | 1230 | 73 | 73 59 | BAK28 |
| 35 29 | 1240 | 74 | 74 60 | BAK29 |
| 36 30 | 1250 | 75 | 75 61 | BAK30 |
| 37 31 | 1260 | 76 | 76 62 | BAK31 |
| 40 32 | 1270 | 77 | 77 63 | BAK32 |
| 41 33 | 640 | 124 | 1040 544 | BAK33 |
| 42 34 | 650 | 125 | 1041 545 | BAK34 |
| 43 35 | 660 | 126 | 1042 546 | BAK35 |
| 44 36 | 670 | 127 | 1043 547 | BAK36 |
| 45 37 | 1100 | 130 | 1044 548 | BAK37 |
| 46 38 | 1110 | 131 | 1045 549 | BAK38 |
| 47 39 | 1120 | 132 | 1046 550 | BAK39 |
| 50 40 | 1130 | 133 | 1047 551 | BAK40 |
| 51 41 | 1140 | 134 | 1050 552 | BAK41 |
| 52 42 | 1150 | 135 | 1051 553 | BAK42 |
| 53 43 | 1160 | 136 | 1052 554 | BAK43 |
Norsk Data NO-30.053.1 EN
Page 35¶
SINTRAN III - How to Order II¶
Terminal Device Numbers¶
| Term. no. | Device No. | IDENT-Code | Logical Dev. no. | Background |
|---|---|---|---|---|
| Oct. | Dec. | Oct. | Dec. | |
| 54 | 44 | 1170 | 137 | 1053 |
| 55 | 45 | 1400 | 140 | 1054 |
| 56 | 46 | 1410 | 141 | 1055 |
| 57 | 47 | 1420 | 142 | 1056 |
| 60 | 48 | 1430 | 143 | 1057 |
| 61 | 49 | 1500 | 144 | 1060 |
| 62 | 50 | 1510 | 145 | 1061 |
| 63 | 51 | 1520 | 146 | 1062 |
| 64 | 52 | 1530 | 147 | 1063 |
| 65 | 53 | 1640 | 150 | 1064 |
| 66 | 54 | 1650 | 151 | 1065 |
| 67 | 55 | 1660 | 152 | 1066 |
| 70 | 56 | 1670 | 153 | 1067 |
| 71 | 57 | 1700 | 154 | 1070 |
| 72 | 58 | 1710 | 155 | 1071 |
| 73 | 59 | 1720 | 156 | 1072 |
| 74 | 60 | 1730 | 157 | 1073 |
| 75 | 61 | 1740 | 160 | 1074 |
| 76 | 62 | 1750 | 161 | 1075 |
| 77 | 63 | 1760 | 162 | 1076 |
| 100 | 64 | 1770 | 163 | 1077 |
| 101 | 65 | 140040 | 140040 | 2000 |
| 102 | 66 | 140041 | 140041 | 2001 |
| 103 | 67 | 140042 | 140042 | 2002 |
| 104 | 68 | 140043 | 140043 | 2003 |
| 105 | 69 | 140044 | 140044 | 2004 |
| 106 | 70 | 140045 | 140045 | 2005 |
| 107 | 71 | 140046 | 140046 | 2006 |
| 110 | 72 | 140047 | 140047 | 2007 |
| 111 | 73 | 140050 | 140050 | 2010 |
| 112 | 74 | 140051 | 140051 | 2011 |
| 113 | 75 | 140052 | 140052 | 2012 |
| 114 | 76 | 140053 | 140053 | 2013 |
| 115 | 77 | 140054 | 140054 | 2014 |
| 116 | 78 | 140055 | 140055 | 2015 |
| 117 | 79 | 140056 | 140056 | 2016 |
| 120 | 80 | 140057 | 140057 | 2017 |
| 121 | 81 | 140060 | 140060 | 2020 |
| 122 | 82 | 140061 | 140061 | 2021 |
| 123 | 83 | 140062 | 140062 | 2022 |
| 124 | 84 | 140063 | 140063 | 2023 |
| 125 | 85 | 140064 | 140064 | 2024 |
| 126 | 86 | 140065 | 140065 | 2025 |
Norsk Data ND-30.053.1 EN
Page 36¶
SINTRAN III - HOW TO ORDER II¶
TERMINAL DEVICE NUMBERS¶
| Term.no. Oct. Dec. | Device No. | IDENT-Code | Logical Dev.no. Oct. Dec. | Background |
|---|---|---|---|---|
| 127 87 | 140660 | 140066 | 2026 1046 | BAK87 |
| 130 88 | 140670 | 140067 | 2027 1047 | BAK88 |
| 131 89 | 140700 | 140070 | 2030 1048 | BAK89 |
| 132 90 | 140710 | 140071 | 2031 1049 | BAK90 |
| 133 91 | 140720 | 140072 | 2032 1050 | BAK91 |
| 134 92 | 140730 | 140073 | 2033 1051 | BAK92 |
| 135 93 | 140740 | 140074 | 2034 1052 | BAK93 |
| 136 94 | 140750 | 140075 | 2035 1053 | BAK94 |
| 137 95 | 140760 | 140076 | 2036 1054 | BAK95 |
| 140 96 | 140770 | 140077 | 2037 1055 | BAK96 |
| 141 97 | 141000 | 140100 | 2040 1056 | BAK97 |
| 142 98 | 141010 | 140101 | 2041 1057 | BAK98 |
| 143 99 | 141020 | 140102 | 2042 1058 | BAK99 |
| 144 100 | 141030 | 140103 | 2043 1059 | BAA100 |
| 145 101 | 141040 | 140104 | 2044 1060 | BAA101 |
| 146 102 | 141050 | 140105 | 2045 1061 | BAA102 |
| 147 103 | 141060 | 140106 | 2046 1062 | BAA103 |
| 150 104 | 141070 | 140107 | 2047 1063 | BAA104 |
| 151 105 | 141100 | 140110 | 2050 1064 | BAA105 |
| 152 106 | 141110 | 140111 | 2051 1065 | BAA106 |
| 153 107 | 141120 | 140112 | 2052 1066 | BAA107 |
| 154 108 | 141130 | 140113 | 2053 1067 | BAA108 |
| 155 109 | 141140 | 140114 | 2054 1068 | BAA109 |
| 156 110 | 141150 | 140115 | 2055 1069 | BAA110 |
| 157 111 | 141160 | 140116 | 2056 1070 | BAA111 |
| 160 112 | 141170 | 140117 | 2057 1071 | BAA112 |
| 161 113 | 141200 | 140120 | 2060 1072 | BAA113 |
| 162 114 | 141210 | 140121 | 2061 1073 | BAA114 |
| 163 115 | 141220 | 140122 | 2062 1074 | BAA115 |
| 164 116 | 141230 | 140123 | 2063 1075 | BAA116 |
| 165 117 | 141240 | 140124 | 2064 1076 | BAA117 |
| 166 118 | 141250 | 140125 | 2065 1077 | BAA118 |
| 167 119 | 141260 | 140126 | 2066 1078 | BAA119 |
| 170 120 | 141270 | 140127 | 2067 1079 | BAA120 |
| 171 121 | 141300 | 140130 | 2070 1080 | BAA121 |
| 172 122 | 141310 | 140131 | 2071 1081 | BAA122 |
| 173 123 | 141320 | 140132 | 2072 1082 | BAA123 |
| 174 124 | 141330 | 140133 | 2073 1083 | BAA124 |
| 175 125 | 141340 | 140134 | 2074 1084 | BAA125 |
| 176 126 | 141350 | 140135 | 2075 1085 | BAA126 |
| 177 127 | 141360 | 140136 | 2076 1086 | BAA127 |
| 200 128 | 141370 | 140137 | 2077 1087 | BAA128 |
| Term.no. Oct. Dec. | Device No. | IDENT-Code | Logical Dev.no. Oct. Dec. | Background |
|---|---|---|---|---|
Norsk Data NO-30.053.1 EN
Page 37¶
8. Overlapping Device Numbers¶
Overlapping Device Numbers, ND-100¶
| Hardware Device Name | First DevNo | Last DevNo | Ident-Code | Comment |
|---|---|---|---|---|
| REAL TIME CLOCK | 3 | 20 | 23 | 6 Overlaps with |
| EXTERNAL INTERRUPT | 2 | 20 | 23 | 6 Overlaps with |
| SYNCHRONOUS MODEM | 7 | 160 | 167 | 40 Overlaps with |
| LINE PRINTER | 3 | 160 | 163 | 35 |
| LINE PRINTER | 4 | 164 | 167 | 36 |
| SYNCHRONOUS MODEM | 8 | 170 | 177 | 10 Overlaps with |
| LINE PRINTER | 5 | 170 | 173 | 33 |
| LINE PRINTER | 6 | 174 | 177 | 32 |
| PARALLELL BYTE OUTPUT | 1 | 430 | 433 | 3 Overlaps with |
| LINE PRINTER | 1 | 430 | 433 | 3 |
| 10 MB DISC CONTR. | 1 | 500 | 507 | 1 Overlaps with |
| FINCH 8" DISC CONTR. | 1 | 500 | 507 | 1 |
| ST506 5" DISC CONTR. | 1 | 500 | 507 | 1 |
| STC MAG TAPE CONTR. | 4 | 500 | 507 | 1 |
| 10 MB DISC CONTR. | 2 | 510 | 517 | 5 Overlaps with |
| FINCH 8" DISC CONTR. | 2 | 510 | 517 | 5 |
| ST506 5" DISC CONTR. | 2 | 510 | 517 | 5 |
| STC MAG TAPE CONTR. | 3 | 510 | 517 | 5 |
| STC MAG TAPE CONTR. | 1 | 520 | 527 | 3 Overlaps with |
| PERTEC MAG TAPE CONTR. | 1 | 520 | 527 | 3 |
| STC MAG TAPE CONTR. | 2 | 530 | 537 | 7 Overlaps with |
| PERTEC MAG TAPE CONTR. | 2 | 530 | 537 | 7 |
| SMD 10 MHZ DISC CONTR. | 3 | 540 | 547 | 2 Overlaps with |
| SMD 15 MHZ DISC CONTR. | 3 | 540 | 547 | 2 |
| SMD 10 MHZ DISC CONTR. | 4 | 550 | 557 | 6 Overlaps with |
| SMD 15 MHZ DISC CONTR. | 4 | 550 | 557 | 6 |
| ND-500 | 5 | 560 | 577 | 76 Overlaps with |
| HASP DMA | 1 | 560 | 577 | 156 |
| VERSATEC DMA | 1 | 600 | 607 | 4 Overlaps with |
| VERSATEC PIO | 1 | 600 | 607 | 4 |
| ND-500 | 3 | 660 | 677 | 36 Overlaps with |
| TERMINAL INTERFACE | 35 | 660 | 667 | 126 |
| TERMINAL INTERFACE | 36 | 670 | 677 | 127 |
| SYNCHRONOUS MODEM | 9 | 1100 | 1107 | 70 Overlaps with |
| TERMINAL INTERFACE | 37 | 1100 | 1107 | 130 |
Norsk Data ND-30.053.1 EN
Page 38¶
SINTRAN III - How to Order It¶
Overlapping Device Numbers¶
| HARDWARE DEVICE NAME | FIRST DEVNO | LAST DEVNO | IDENT-CODE | Notes |
|---|---|---|---|---|
| SYNCHRONOUS MODEM | 10 | 1110 | 1117 | 44 |
| TERMINAL INTERFACE | 38 | 1110 | 1117 | 131 |
| SYNCHRONOUS MODEM | 11 | 1120 | 1127 | 50 |
| TERMINAL INTERFACE | 39 | 1120 | 1127 | 132 |
| SYNCHRONOUS MODEM | 12 | 1130 | 1137 | 54 |
| TERMINAL INTERFACE | 40 | 1130 | 1137 | 133 |
| SYNCHRONOUS MODEM | 13 | 1140 | 1147 | 60 |
| TERMINAL INTERFACE | 41 | 1140 | 1147 | 134 |
| SYNCHRONOUS MODEM | 14 | 1150 | 1157 | 64 |
| TERMINAL INTERFACE | 42 | 1150 | 1157 | 135 |
| SYNCHRONOUS MODEM | 15 | 1160 | 1167 | 74 |
| TERMINAL INTERFACE | 43 | 1160 | 1167 | 136 |
| SYNCHRONOUS MODEM | 16 | 1170 | 1177 | 75 |
| TERMINAL INTERFACE | 44 | 1170 | 1177 | 137 |
| UNIVERSAL DMA, Nord-10 | 1 | 1400 | 1407 | 24 |
| TERMINAL INTERFACE | 45 | 1400 | 1407 | 140 |
| UNIVERSAL DMA, Nord-10 | 2 | 1410 | 1417 | 25 |
| TERMINAL INTERFACE | 46 | 1410 | 1417 | 141 |
| UNIVERSAL DMA, Nord-10 | 3 | 1420 | 1427 | 26 |
| TERMINAL INTERFACE | 47 | 1420 | 1427 | 142 |
| UNIVERSAL DMA, Nord-10 | 4 | 1430 | 1437 | 27 |
| TERMINAL INTERFACE | 48 | 1430 | 1437 | 143 |
| HASP DMA | 5 | 1500 | 1517 | 162 |
| UNIVERSAL DMA, Nord-10 | 9 | 1500 | 1507 | 34 |
| TERMINAL INTERFACE | 49 | 1500 | 1507 | 144 |
| UNIVERSAL DMA, Nord-10 | 10 | 1510 | 1517 | 35 |
| TERMINAL INTERFACE | 50 | 1510 | 1517 | 145 |
| HASP DMA | 6 | 1520 | 1537 | 163 |
| TERMINAL INTERFACE | 51 | 1520 | 1527 | 146 |
| TERMINAL INTERFACE | 52 | 1530 | 1537 | 147 |
| SMD 10 MHZ DISC CONTR. | 1 | 1540 | 1547 | 17 |
| SMD 15 MHZ DISC CONTR. | 1 | 1540 | 1547 | 17 |
| SMD 10 MHZ DISC CONTR. | 2 | 1550 | 1557 | 20 |
| SMD 15 MHZ DISC CONTR. | 2 | 1550 | 1557 | 20 |
| FLOPPY DISC PIO | 1 | 1560 | 1567 | 21 |
| FLOPPY DISC DMA | 1 | 1560 | 1567 | 21 |
| FLOPPY & STREAMER 8’ | 1 | 1560 | 1567 | 21 |
| FLOPPY & STREAMER 5 & 8 | 1 | 1560 | 1567 | 21 |
Norsk Data ND-30.053.1 EN
Page 39¶
SINTRAN III - HOW TO ORDER IT¶
OVERLAPPING DEVICE NUMBERS¶
| HARDWARE DEVICE NAME | FIRST DEVNO | LAST DEVNO | IDENT-CODE | Overlaps with |
|---|---|---|---|---|
| FLOPPY DISC PIO | 2 | 1570 | 1577 | 22 |
| FLOPPY DISC DMA | 2 | 1570 | 1577 | 22 |
| FLOPPY & STREAMER 8" | 2 | 1570 | 1577 | 22 |
| FLOPPY & STREAMER 5 & 8 | 2 | 1570 | 1577 | 22 |
| VERSATEC DMA | 2 | 1600 | 1607 | 14 |
| VERSATEC PIO | 2 | 1600 | 1607 | 14 |
| HOLC AUTO LOAD | 1600 | 1603 | ||
| HDLC REMOTE LOAD | 1 | 1604 | 1607 | |
| HDLC / MEGALINK | 1 | 1640 | 1657 | 150 |
| TERMINAL INTERFACE 53 | 3 | 1640 | 1647 | 150 |
| TERMINAL INTERFACE 54 | 1650 | 1657 | 151 | |
| HDLC / MEGALINK | 2 | 1660 | 1677 | 151 |
| TERMINAL INTERFACE 55 | 3 | 1660 | 1667 | 152 |
| TERMINAL INTERFACE 56 | 1670 | 1677 | 153 | |
| HDLC / MEGALINK | 3 | 1700 | 1717 | 152 |
| TERMINAL INTERFACE 57 | 3 | 1700 | 1707 | 154 |
| TERMINAL INTERFACE 58 | 1710 | 1717 | 155 | |
| HDLC / MEGALINK | 4 | 1720 | 1737 | 153 |
| TERMINAL INTERFACE 59 | 3 | 1720 | 1727 | 156 |
| TERMINAL INTERFACE 60 | 1730 | 1737 | 157 | |
| HDLC / MEGALINK | 5 | 1740 | 1757 | 154 |
| TERMINAL INTERFACE 61 | 3 | 1740 | 1747 | 160 |
| TERMINAL INTERFACE 62 | 1750 | 1757 | 161 | |
| HDLC / MEGALINK | 6 | 1760 | 1777 | 155 |
| TERMINAL INTERFACE 63 | 3 | 1760 | 1767 | 162 |
| TERMINAL INTERFACE 64 | 1770 | 1777 | 163 |
Norsk Data ND-30.053.1 EN
Page 40¶
SINTRAN III - HOW TO ORDER IT¶
OVERLAPPING DEVICE NUMBERS
APPENDIX A¶
SINTRAN III ORDER FORM¶
On the next two pages you will find a complete SINTRAN III order form.
Norsk Data ND-30.053.1 EN
Page 41¶
I'm sorry, but I can't read the text or see any diagrams from the image you provided. The image appears to be illegible due to the yellow overlay and low contrast. Could you provide a clearer image or describe the contents, and I'll assist you in converting it to Markdown.
Page 42¶
SINTRAN III ORDER¶
Customer Information¶
- Customer:
- CPU No:
- Date:
- Tomer Rep.:
- Phone:
- Maint.:
- Customer Notes:
- Issued By:
- Dumped: (1)
- Listing: (2)
Mass Storage¶
Available Sizes on Removeable Packs¶
| Size | 23MB | 34MB | 70MB | 75MB |
|---|---|---|---|---|
| 280MB AS: | 280MB R | 280MB R | 3-75MB R | |
| 4-70MB R | ||||
| Control 1 | .......MB | .......MB | .......MB | .......MB |
| Control 2 | .......MB | .......MB | .......MB | .......MB |
Phoenix¶
| Unit | 0 | 1 | 2 | 3 |
|---|---|---|---|---|
| 30MB | 60MB | 90MB | ||
| Control 1 | .......MB | .......MB | .......MB | .......MB |
| Control 2 | .......MB | .......MB | .......MB | .......MB |
Available Sizes on Winchester Drives: 14, 16, 21, 23, 45, Hawk: 10¶
| Unit | 0 | 1 |
|---|---|---|
| Control 1 | .......MB | .......MB |
| Control 2 | .......MB | .......MB |
Control/Unit¶
| MAG-TAPES | FLOPPY DISK | |
|---|---|---|
| 1/ | HP | PERT |
| 2/ | ||
Terminals (3)¶
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
B
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96
97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120
121 122 123 124 125 126 127 128
R B
Notes¶
(1) 8: ON 8" FLOPPY 5: ON 5 1/4" FLOPPY
(2) C: COMPLETE LISTING F: ON FLOPPY
S: SYMBOL LISTING P: ON PAPER
N: NO LISTING
(Default: Listing on FLOPPY)
(3) B: TERM. WITH BACKGROUND
A: TERM. WITHOUT BACKGROUND
S: PRINTER TERM. WITH SPOOLING
P: PRINTER TERM. WITHOUT SPOOLING
T: TEXT EDITING (TERM. 16-2)
F: PHOTOSETTER (TERM. 29-31)
H: HARRIS PHOTOSETTER (TERM. 29-30)
G: GRAF CASSETTE (TERM. 27-28)
X: RESERVED FOR ND-NET
Delivery¶
- Mail:
- Local Pickup:
Software Notes¶
| Vers | Gen By | Date | |
|---|---|---|---|
Page 43¶
SINTRAN III ORDER¶
Input/Output Devices and Spooling¶
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 1-8 | 1-4 | 1-4 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HDLC DMA DRIVER | |||||||||||||||
| SYNC. MOD. HDLC (H/S) | |||||||||||||||
| (4) | |||||||||||||||
| PIOC | |||||||||||||||
| GPIB | |||||||||||||||
| OCTOBUS | |||||||||||||||
| MPM-4 | |||||||||||||||
| BUS EXPANDER |
| X.21 | X.25 | X.29 | SYNCRONOUS MODEMS (4) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1-8 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| CAMAC | UNIVERSAL DMA / VICOM INTERFACES (D/V) | FAST UDMA/VICOM OPT. FOR ND-500 |
|---|---|---|
| 1 2 3 4 5 5 6 7 8 9 10 11 12 13 14 15 16 |
| LINE- PRINTER | VERSATEC | COSMOS | DEVICE NUMBER FOR SPOOLING (5) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DMA, I/O SPOOLING |
System Parameters¶
| RT PROG. | SEGM. | SEMA- CHAR. | INTERN. DEVICE BLOCK | BATCH PROC. | CX CPU | DEV BUF | SYMB. DEBUG. | FILE ACC. SEGM. | CONN. TO DEVICE | TERM. ACCESS | ND-500 OR PROC |
|---|---|---|---|---|---|---|---|---|---|---|---|
| .50- | .75- | .5- | .2- | .1- | 20- | -10 |
Accounting¶
| NOI PANEL | SIBAS | REMOTE JOB ENTRIES | RT BACKGR. | ALLOC |
|---|---|---|---|---|
| RT I/O | CLOCK | 1-3 1-6 1-12 HASP DMA IBM HONEYWELL UNIVAC CDC COMM | # NO OF BACK |
Logging Functions¶
| SWAP DISC ACCESS | MON CALL | SCREEN | LAMU | READ SEGM (6) | TPS NET(7) | NORD | DIRECT TASK | NO. OF RT-PROG FROM DIR. TASK |
|---|---|---|---|---|---|---|---|---|
| M-T FROM DIRECT TASK | DIRECT TRANSFER ON M-T | CONNECT DATAFIELD | EXTEND OPEN FILE TABLE |
|---|---|---|---|
NO-NET¶
| LINE NO | ASYNC | SYNC MODEM FULL DPX. HALF DPX. DMA | H D L C I/O | CHANNELS | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | ||||||||||||||||||||
| 2 | ||||||||||||||||||||
| 3 | ||||||||||||||||||||
| 4 | ||||||||||||||||||||
| 5 | ||||||||||||||||||||
| 6 | ||||||||||||||||||||
| 7 | ||||||||||||||||||||
| 8 | ||||||||||||||||||||
| 9 |
POOL:
(4) EXCLUSIVE OF NO-NET CONNECTIONS
(5) GIVE OCTAL NUMBERS
(6) GIVE DECIMAL NUMBERS OF TERMINALS RUNNING TPS
(7) SPECIFY CONFIGURATION BELOW
Every SINTRAN will also contain as standard:
MAGTP, ECHO BREAK TABLE 7, TELINT/TELNET, EXTENDED ADDRESS MODE,
FIXC, 5 FIXC500, X-MESSAGE, XON/XOFF, INSTING/OUTSTRING, MON LOGIN
Page 44¶
SEND US YOUR COMMENTS!!!¶
_________
/ \\
( Please )
\_________/
Are you frustrated because of unclear information in this manual? Do you have trouble finding things? Why don’t you join the Reader’s Club and send us a note? You will receive a membership card — and an answer to your comments.
Please let us know if you - find errors - cannot understand information - cannot find information - find needless information
Do you think we could improve the manual by rearranging the contents? You could also tell us if you like the manual!
_____
/ \\
| ND |
\_____|
| |
| |
HELP YOURSELF BY HELPING US!!¶
Manual name: SINTRAN III — How to order it
Manual number: ND-30.053.1 EN
What problems do you have? (use extra pages if needed)
Do you have suggestions for improving this manual?
Your name: _____ Date: ____
Company: ______ Position: ___
Address: ______
What are you using this manual for?
| NOTE! | Send to: |
|---|---|
| This form is primarily for documentation errors. Software and system errors should be reported on Customer System Reports. | Norsk Data A.S Documentation Department P.O. Box 25, Bogerud 0621 Oslo 6, Norway Norsk Data's answer will be found on reverse side |
Page 45¶
Answer from Norsk Data¶
| Answered by | Date |
|---|---|
Norsk Data A.S
Documentation Department
P.O. Box 25, Bogerud
0621 Oslo6, Norway
Page 46¶
I'm unable to extract text or convert from the given image because it does not contain any visible text to convert into Markdown format. If you have another image with text, feel free to share it!