COMP - Compare

Overview

Mnemonic: comp Function: Compare with accumulator (register) Class: COMPARE Privilege: user

Format: t COMP <operand> (implicitly compares accumulator register with operand)


Description

Compares the implicit accumulator register (determined by register number embedded in opcode) with the specified operand by performing a subtraction without storing the result. Sets status flags Z, S, C, V based on the comparison result, enabling subsequent conditional branches.

COMP is the fundamental comparison instruction in the ND-500 architecture. Unlike SUB, it discards the arithmetic result and only updates flags. This "true comparison" correctly handles signed overflow - the sign bit accurately reflects the comparison result even when subtraction would overflow.

Comparison Semantics:

FLAGS = (Accumulator - Operand)  % Result discarded, only flags set

Status Flag Interpretation:

  • Equal: Z=1 (accumulator == operand)
  • Not Equal: Z=0 (accumulator != operand)
  • Less Than (signed): S=1, Z=0 (accumulator < operand)
  • Greater Than (signed): S=0, Z=0 (accumulator > operand)
  • Less/Equal (signed): S=1 OR Z=1 (accumulator <= operand)
  • Greater/Equal (signed): S=0 OR Z=1 (accumulator >= operand)

Key Characteristics:

  1. Implicit Accumulator: Register number (1-24) encoded in opcode - no explicit destination register
  2. Non-Destructive: Accumulator and operand unchanged; only flags modified
  3. True Comparison: Sign flag correctly reflects signed comparison even on overflow
  4. All Data Types: Supports BI, BY, H, W, F, D types with appropriate comparison semantics
  5. Conditional Branch Integration: Designed to precede IF=GO, IFGO, etc.

Common Use Cases:

  • Loop termination conditions (COMP counter, limit)
  • Bounds checking (COMP index, array_size)
  • Null/zero detection (COMP value, 0)
  • Range validation (COMP input, MIN / COMP input, MAX)
  • Sorting comparisons
  • Search termination
  • Conditional execution guards

COMP is typically followed by conditional branch instructions that test the flags it sets. The combination COMP + IFxGO is one of the most common instruction pairs in ND-500 code.

Operands: 1 (plus implicit accumulator register) Variants: 24 opcode(s)


Variants

Variant Opcode Range Register Assembly Notation Note
1-24 0x0030-0x003F
0xFC18-0xFC1F
R1-R24 BI/BY/H/W/F/D COMP 24 register variants

Note: Opcode encodes both the register number and operation. Different opcode ranges for different register groups.


Operands

Operand 1 (Comparand, Read):

  • Addressing modes: LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE
  • Data type: Same as instruction prefix (BI/BY/H/W/F/D)
  • Role: Value to compare against accumulator

Implicit Accumulator (Source):

  • Register: Encoded in opcode (R1-R24)
  • Role: Left-hand side of comparison

Result: No result register - only status flags updated


Trap Conditions

  • Addressing traps: Invalid address or protection violation
  • Floating-point exceptions: For F/D types (invalid operation, denormal)

Note: COMP does NOT trap on signed overflow (unlike some arithmetic ops)


Data Status Bits

  • Z (Zero): Set if accumulator == operand
  • S (Sign): Set if accumulator < operand (signed comparison)
  • C (Carry): Set if no borrow (accumulator >= operand unsigned). C=1 means A >= B, C=0 means A < B.
  • V (Overflow): Set if signed comparison would overflow (but S still correct!)
  • K (Interrupt bits): Unaffected

Examples

Example 1: Loop termination

% Loop from 0 to LIMIT-1
        W1 CLR
LOOP:
        % Loop body
        W1 ADD 1, I1
        W1 COMP I1, LIMIT
        IF<GO LOOP        % Continue if I1 < LIMIT

Example 2: Bounds checking

% Check if index within array bounds
        W1 COMP INDEX, 0
        IF<GO UNDERFLOW   % Index < 0 (invalid)
        W1 COMP INDEX, ARRAY_SIZE
        IF>=GO OVERFLOW   % Index >= SIZE (invalid)
        % Index is valid

Example 3: Null pointer check

% Check if pointer is null
        W1 COMP PTR, 0
        IF=GO NULL_PTR_HANDLER
        % Pointer is valid, continue

Example 4: Floating-point comparison

% Compare temperature against threshold
        F1 COMP TEMPERATURE, THRESHOLD
        IF>GO OVERHEAT_ALARM
        IF<GO UNDERHEAT_ALARM
        % Within normal range

Example 5: Search loop

% Linear search for value
        W1 CLR
SEARCH:
        W2 COMP ARRAY(I1), TARGET
        IF=GO FOUND
        W1 ADD 1, I1
        W1 COMP I1, COUNT
        IF<GO SEARCH
        % Not found
        GO NOT_FOUND
FOUND:
        % I1 contains index of found element

Example 6: Three-way comparison (sorting)

% Compare A and B for sorting
        W1 COMP A, B
        IF<GO A_LESS_THAN_B
        IF>GO A_GREATER_THAN_B
        % A == B (equal)
        GO EQUAL_HANDLER

A_LESS_THAN_B:
        % A < B
        GO SORT_ASCENDING

A_GREATER_THAN_B:
        % A > B
        GO SORT_DESCENDING

Example 7: Range validation

% Validate input is in range [MIN, MAX]
        W1 COMP INPUT, MIN
        IF<GO OUT_OF_RANGE    % INPUT < MIN
        W1 COMP INPUT, MAX
        IF>GO OUT_OF_RANGE    % INPUT > MAX
        % Input is valid
        GO PROCESS_INPUT

Performance Notes

  • Size: 2+ bytes (opcode + operand encoding)
  • Execution Time: Typically 1-2 cycles (register comparison)
  • vs SUB: COMP is semantically better for comparisons (no result to discard)
  • Branch Pairing: Modern implementations may fuse COMP+IFxGO into single µop
  • Overflow Safety: Sign flag remains correct even on signed overflow
  • Floating-Point: F/D comparisons follow IEEE 754 semantics
  • Optimization: Compilers emit COMP instead of SUB when result unused

Reference Manual

Section: §10.9 Title: Compare


See Also

  • IF=GO - Conditional branch if equal
  • IF<GO - Conditional branch if less than
  • IF>GO - Conditional branch if greater than
  • IF>=GO - Conditional branch if greater or equal
  • IF<=GO - Conditional branch if less or equal
  • TEST - Bitwise test operation
  • COMP2 - Two-operand compare
  • SUB - Subtraction with result