Skip to content

NCPLC - Convert ND-500 descriptor to PLANC descriptor

Overview

Mnemonic: ncplc
Class: SYSTEM (the grouping used by this project)
Privilege: not stated in the manual
Extension: '87 extension (ND-500 Reference Manual ND-05.009.4, June 1987 edition; the manual says it also runs on ND-500/1 and ND-500/2)
Manual section: 15.16, page 269

Variants

Total opcodes: 1

Opcode Assembly
0xFFFE w ncplc

The opcodes are from the octal column of the manual's code table. The operand rules the assembler uses were copied from the nearest existing instruction with the same format; they are not stated in the manual (see the list of unproven points in the plan).


From the ND-500 Reference Manual

Copied from the manual's Markdown; the manual's tables are as printed.

Format: W NCPLC <source/r/W>,<destination/w/W>

Assembly notation Name Hex code Octal code
W NCPLC convert to PLANC descriptor FFFEH 177776B

Operation:

A -> a O -> l N - 1 -> u If u-l+1 < 0, 0 -> N

Description:

Convert ND-500 descriptor to planc descriptor.

The descriptors are as shown below:

ND-500 descriptor Planc descriptor
Number of elements (N) address (a)
Address (A) lower (l)
upper (u)

Data Status Bits:

Upper = O -> Z Signbit -> S


See Also