RECVE - Receive from port¶
Overview¶
Mnemonic: recve
Class: IO (the grouping used by this project)
Privilege: not stated in the manual
Extension: '87 extension (ND-500 Reference Manual ND-05.009.4, June 1987 edition; the manual says it also runs on ND-500/1 and ND-500/2)
Manual section: 16.26.4, page 304
Variants¶
Total opcodes: 1
| Opcode | Assembly |
|---|---|
| 0x00B7 | w1 recve |
The opcodes are from the octal column of the manual's code table. The operand rules the assembler uses were copied from the nearest existing instruction with the same format; they are not stated in the manual (see the list of unproven points in the plan).
From the ND-500 Reference Manual¶
Copied from the manual's Markdown; the manual's tables are as printed.
Format:
W1 RECVE
| Assembly notation | Name | Hex code | Octal code |
|---|---|---|---|
| W1 RECVE | receive from port | B7H | 267B |
Operation:
\
Description:
Receive message from hole number. Message is returned in register 1. Size of message is returned in 'number of bytes'.
Trap Conditions: Protect violation, Illegal operand specifier
Data Status Bits: Unaffected
See Also¶
- ND-5000 '87 extension instructions - all 25, with counts
- IO instruction reference