Skip to content

SHL - Shift Left (Logical Shift)

Overview

Mnemonic: shl Function: Logical left shift (or right shift with negative count) Class: SHIFT Privilege: user Format: t SHL <operand>, <count>


Description

Performs a logical shift operation on a byte, halfword, or word operand. The shift count is interpreted as a signed byte value:

  • Positive count: Shifts left (bits move toward MSB)
  • Negative count: Shifts right (bits move toward LSB)
  • Zero count: No operation (operand unchanged)

In a logical shift, zeros are shifted in from the opposite end. Bits shifted out are discarded (the last bit shifted out goes to the carry flag).

Operation:

For positive count (left shift):
  operand << count → operand
  Zeros fill from right
  MSB bits shifted out to carry

For negative count (right shift):
  operand >> |count| → operand
  Zeros fill from left
  LSB bits shifted out to carry

result = 0 → Z flag
result.signbit → S flag

Key Characteristics:

  • Logical shift (zeros fill from opposite end)
  • Bidirectional: positive count = left, negative count = right
  • Last bit shifted out captured in carry flag
  • Fast multiplication/division by powers of 2
  • Supports byte, halfword, and word types (no bit/float/double)
  • Sets Z and S flags based on result
  • Variable shift count (runtime-determined via signed byte)
  • More efficient than repeated add/subtract for powers of 2

Common Use Cases:

  • Multiplication/division by powers of 2
  • Bit field alignment
  • Mask generation
  • Data packing/unpacking
  • Fast arithmetic operations
  • Bit manipulation

Operands: 2 (operand to shift, shift count) Variants: 3 opcodes (BY, H, W - no bit or float types)


Variants

Variant Opcode Data Type Assembly Notation
1/3 0xFCA8 Byte BY SHL
2/3 0xFCA9 Halfword H SHL
3/3 0xFCAA Word W SHL

Note: SHL is not available for BI (bit), F (float), or D (double) data types.


Operands

Operand 1 (Destination, Read-Modify-Write):

  • Addressing modes: LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE
  • Data type: Matches instruction prefix (BY/H/W)
  • Role: Value to be shifted
  • Access: Read original, write shifted result

Operand 2 (Shift Count, Read):

  • Addressing modes: LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE
  • Data type: Signed byte value
  • Role: Number of positions to shift
  • Range: -(size-1) to +(size-1)
    • BY: -7 to +7
    • H: -15 to +15
    • W: -31 to +31
  • Trap: Count >= operand size causes illegal operand value trap

Trap Conditions

  • Addressing traps: Invalid address, page fault, protection violation
  • Illegal operand value (IOV): Shift count >= operand bit size

Data Status Bits

  • Z (Zero): Set if result = 0, cleared otherwise
  • S (Sign): Set to result's sign bit
  • C (Carry): Last bit shifted out
  • V (Overflow): Unaffected

Examples

Example 1: Multiply by 2 (shift left 1)

        % Fast multiply by 2
        W1 := B.VALUE
        W1 SHL 1            % Equivalent to W1 * 2

Example 2: Multiply by 256 (shift left 8)

        % Shift left 8 positions
        W2 SHL 8            % Equivalent to W2 * 256

Example 3: Shift right using negative count

        % Divide by 4 (shift right 2)
        W3 SHL -2           % Equivalent to W3 / 4 (logical)

Example 4: Shift byte value

        % Shift byte left by 4 bits
        BY1 SHL 4

Example 5: Variable shift count

        % Shift by count in variable
        W SHL B.COUNT, TWOFACTORS

Example 6: Align bit field

        % Align 12-bit value to upper bits
        H1 SHL 4            % Move bits 0-11 to bits 4-15

Example 7: Create bit mask

        % Create mask with N ones
        W1 := 1
        W1 SHL B.NUM_BITS
        W1 DEC              % Now has NUM_BITS ones

Example 8: Extract and align field

        % Extract field from packed data
        W1 MOVE PACKED_DATA
        W1 SHL 16           % Align field to high bits
        W1 SHL -24          % Right-align 8-bit field

Example 9: Power of 2 multiplication

        % Multiply by 16 (2^4)
        W2 := B.VALUE
        W2 SHL 4

Example 10: Zero shift (no-op)

        % Legal but does nothing
        W1 SHL 0            % No change, flags updated

Performance Notes

  • Execution: 2-3 cycles depending on shift count
    • Small shifts (1-8): ~2 cycles
    • Large shifts (>8): ~3 cycles
  • Direction: Negative count performs right shift
  • Optimization: Use SHL for powers-of-2 multiplication instead of MUL
  • Trap overhead: Shift count validation adds minimal overhead

Multiplication equivalents:

% Instead of:
W1 MUL 2            % Slower

% Use:
W1 SHL 1            % Faster

% Powers of 2:
W1 SHL 2            % × 4
W1 SHL 3            % × 8
W1 SHL 4            % × 16
W1 SHL 5            % × 32

Shift count validation:

% Valid shifts (W type, 32-bit):
W1 SHL 31           % OK - shift left 31 positions
W1 SHL -31          % OK - shift right 31 positions
W1 SHL 0            % OK - no-op

% Invalid (traps):
W1 SHL 32           % TRAP - IOV
W1 SHL -32          % TRAP - IOV

% For halfword (16-bit):
H1 SHL 15           % OK
H1 SHL 16           % TRAP - IOV

% For byte (8-bit):
BY1 SHL 7           % OK
BY1 SHL 8           % TRAP - IOV

Logical vs Arithmetic shift:

  • SHL: Logical shift (zeros fill)
  • SHA: Arithmetic shift (sign bit preserved on right shift)
  • For left shifts, SHL and SHA behave identically
  • For right shifts:
    • SHL fills with zeros
    • SHA fills with sign bit (preserves sign for signed numbers)

Reference Manual

Section: §10.24 Title: Logical shift


See Also

  • SHR - Shift right (if separate instruction exists)
  • SHA - Shift arithmetic (preserves sign)
  • MUL - Multiplication (slower than shift for powers of 2)