Disassembly Display Issues - Fixed¶
Summary¶
Two issues were identified and fixed in the WASM debugger's disassembly display:
- PC incorrectly set to 0 instead of 4 - Entry point not honored for executables
- Addresses shown as signed decimals - Hard to read (e.g.,
-402649088instead of0xE8001000)
Issue 1: PC Set to 0 Instead of Entry Point (0x4)¶
Problem¶
When loading the kernel executable, the debugger set PC to 0 instead of 4, causing disassembly to start at the a.out header (invalid instructions) rather than the first executable instruction (INIT).
Symptoms:
Disassembly starting at 0x00000000:
00000000 00 ???
00000001 00 ???
00000002 00 ???
00000003 00 ???
00000004 DC... init $-402649088,$20,$16384 ← Should start here!
Root Cause¶
File: src/ndlib/ndlib_aout.c (Line 442)
Buggy code:
if (entry == 0 || entry == 4) {
/* Object file - use first instruction from map */
uint32_t first_instr = ndlib_symbols_first_instruction_addr();
pc = (first_instr > 0) ? first_instr : 0;
} else {
/* Executable - use entry point */
pc = entry;
}
Problem: The condition entry == 4 incorrectly assumes entry point 4 means "object file". This is wrong! Entry point 4 is valid for executables (it's where code starts after the 4-byte a.out header).
Why entry point is 4:
- Bytes 0-3: a.out magic number (0x0109) and header
- Byte 4+: First executable instruction
Fix¶
File: src/ndlib/ndlib_aout.c (Line 442-449)
Fixed code:
if (entry == 0) {
/* Object file (no entry point) - use first instruction from map */
uint32_t first_instr = ndlib_symbols_first_instruction_addr();
pc = (first_instr > 0) ? first_instr : 0;
} else {
/* Executable - use entry point (even if it's 4) */
pc = entry;
}
Changes:
- Removed
|| entry == 4condition - Only treat
entry == 0as object file - All non-zero entry points are valid for executables
Result¶
After fix, PC is correctly set to 0x00000004, and disassembly starts at the INIT instruction.
Issue 2: Address Display Format (Disassembler Formatting)¶
Problem¶
The disassembler shows addresses as signed decimal integers instead of hexadecimal, making them hard to read and correlate with memory addresses.
Example:
init $-402649088,$20,$16384
Should be:
init $0xE8001000,$20,$16384
Analysis¶
The value -402649088 is mathematically correct - it's the signed 32-bit interpretation of 0xE8001000:
>>> hex(0xE8001000)
'0xe8001000'
>>> int(0xE8001000) # Unsigned
3892318208
>>> struct.unpack('i', struct.pack('I', 0xE8001000))[0] # Signed
-402649088
Since 0xE8001000 has bit 31 set (high bit), it's negative when interpreted as signed int32.
Root Cause¶
The disassembler uses %d format (signed decimal) instead of 0x%X format (hexadecimal) for immediate operands.
File: Disassembler formatting code (need to locate exact location)
Fix Needed¶
The disassembler should:
- Display addresses and large constants in hexadecimal (
0x...) - Display small constants (<256) in decimal for readability
- Use unsigned interpretation for all addresses
Example improved output:
Before: init $-402649088,$20,$16384
After: init $0xE8001000,$20,$16384
Before: call $436207616,$0
After: call $0x1A000000,$0 (or with symbol: call _kernel_main,$0)
Status¶
Issue 1 (PC): ✓ FIXED - WASM build updated Issue 2 (Display): ⚠ Identified - Requires disassembler formatting changes
Verification¶
Test Case: Load kernel.zip in WASM Debugger¶
Before fix:
PC = 0x00000000
Disassembly shows:
00000000 00 ???
00000001 00 ???
00000002 00 ???
00000003 00 ???
After fix:
PC = 0x00000004
Disassembly shows:
00000004 DC 00 10 00 E8 14 CE 00 40 init $-402649088,$20,$16384
0000000D 1D FF dctsb
0000000F 1C FF pctsb
Expected after Issue 2 fix:
PC = 0x00000004
Disassembly shows:
00000004 DC 00 10 00 E8 14 CE 00 40 init $0xE8001000,$20,$16384
0000000D 1D FF dctsb
0000000F 1C FF pctsb
00000011 C3 00 00 00 1A 00 call $0x1A000000,$0
Build and Test¶
# Rebuild WASM with PC fix
cd .
make wasm
# Start web server
make wasm-serve
# Open browser to http://localhost:8000
# Load Demo Kernel
# Check browser console for PC value
# Verify disassembly starts at 0x00000004
Expected console output:
[updateUI] PC updated: 0x00000004
[updateDisassembly] currentPC=0x4
Technical Details¶
A.out File Format¶
Header (32 bytes):
Offset Size Field Value (kernel)
------ ---- ---------- --------------
0x00 2 a_magic 0x0109 (IMAGIC)
0x02 2 (padding) 0x0000
0x04 4 a_text 762 bytes (0x2FA)
0x08 4 a_data 72 bytes (0x48)
0x0C 4 a_bss 78608 bytes (0x13310)
0x10 4 a_syms 408 bytes (0x198)
0x14 4 a_entry 0x00000004 ← Entry point!
0x18 4 a_trsize 0 bytes
0x1C 4 a_drsize 0 bytes
Text segment starts at offset 0x20 (after header) Entry point 0x04 is relative to memory address 0, not file offset
When loaded into memory:
- Memory 0x00-0x03: Header (not executable, shows as ???)
- Memory 0x04: First instruction (INIT) ← Entry point points here
Why Entry Point is 4¶
The a.out format uses memory addresses, not file offsets:
- File offset 0x20 contains the first instruction byte
- But that instruction loads at memory address 0x04
- Entry point field contains 0x04 (memory address)
- Loader skips the header bytes when loading to memory
Object Files vs Executables¶
Object File (.o):
- Magic: 0x0107 (OMAGIC) or 0x010B
- Entry point: 0 (no entry - needs linking)
- Relocations present (a_trsize, a_drsize > 0)
Executable:
- Magic: 0x0109 (IMAGIC)
- Entry point: Non-zero (e.g., 0x04)
- Relocations removed (a_trsize, a_drsize = 0)
- All symbols resolved
Previous buggy logic assumed:
if (entry == 0 || entry == 4) // WRONG!
→ treat as object file
Correct logic:
if (entry == 0) // RIGHT!
→ treat as object file (no entry point set)
else
→ treat as executable (entry point valid)
Impact¶
Before Fix¶
User experience:
- Loads kernel.zip
- Sees disassembly starting at 0x00000000
- First 4 lines show
???(invalid instructions) - INIT instruction shown at line 5
- Can't single-step from PC=0 (would trap on 0x00)
- Must manually
set PC 4before stepping
JavaScript console shows:
PC = 0x00000000
[updateDisassembly] currentPC=0x0
After Fix¶
User experience:
- Loads kernel.zip
- PC automatically set to 0x00000004
- Disassembly starts at INIT instruction
- Single-step works immediately
- No manual PC adjustment needed
JavaScript console shows:
PC = 0x00000004
[updateDisassembly] currentPC=0x4
[INIT] Stack initialized at B=0xE8001000, TOS=0xE8005000
Future Improvements¶
Disassembler Hex Formatting¶
Changes needed in disassembler:
-
Address operands → Always hex
// Before: printf("$%d", value); // After: printf("$0x%08X", value); -
Small constants → Decimal (for readability)
if (value < 256) { printf("$%d", value); } else { printf("$0x%X", value); } -
Symbol resolution (if symbol available)
const char* sym = nd500_symbols_lookup_addr(value); if (sym) { printf("%s", sym); // e.g., "_kernel_main" } else { printf("$0x%08X", value); }
Example Improved Output¶
Current:
00000004 init $-402649088,$20,$16384
00000011 call $436207616,$0
Improved:
00000004 init $0xE8001000,$20,$16384
00000011 call _kernel_main,$0
Or with both address and symbol:
00000011 call _kernel_main @ 0x1A000000,$0
Summary¶
| Issue | Status | Impact |
|---|---|---|
| PC set to 0 instead of 4 | ✓ FIXED | Critical - allows proper execution from entry point |
| Addresses shown as signed decimal | ⚠ Identified | Minor - cosmetic, doesn't affect functionality |
Fix deployed: WASM build updated with PC fix in build_wasm/bin/
Remaining work: Update disassembler to show hex addresses (cosmetic improvement)
Files Modified:
src/ndlib/ndlib_aout.c(Line 442: Fixed PC initialization logic)
Build command:
make wasm
Verification:
make wasm-serve
# Open http://localhost:8000
# Load Demo Kernel
# Verify PC = 0x00000004 in debugger