CLEBI - Clear Bit¶
Overview¶
Mnemonic: clebi
Function: Clear bit to 0 unconditionally
Class: BITFIELD
Privilege: user
Format: t CLEBI <operand/w/t>,<bit No./r/BY>
Description¶
Clears a specified bit in an operand to 0, regardless of its previous value. Only the specified bit is affected; all other bits in the operand remain unchanged.
Key Characteristics:
- Unconditional bit clear operation (always sets to 0)
- Single-instruction bit manipulation (no register required)
- Supports 3 data types: BY (8-bit), H (16-bit), W (32-bit)
- More efficient than PUTBI for known bit clears
- Z flag always set to 1 (distinguishes from PUTBI)
- Essential for flag clearing and hardware control
- Not atomic (requires synchronization in multiprocessor systems)
- Traps on out-of-range bit numbers
The bit number specifies which bit to clear, with bit numbering following the ND-500 convention where bit 0 is the rightmost (least significant) bit. The operand can be a byte (BY), halfword (H), or word (W) data type.
Unlike PUTBI which stores a register bit value, CLEBI unconditionally clears the target bit to 0. This makes it more efficient when you know you want to clear a bit without first loading a register.
An illegal operand value trap (IOV) is triggered if:
<bit No.>is negative<bit No.>>= number of bits in the data type (8 for BY, 16 for H, 32 for W)
This instruction is essential for:
- Disabling flag bits
- Clearing hardware control bits
- Implementing bit clears
- Resetting status flags
Operands: 2 Variants: 3 opcode(s)
Variants¶
Total variants: 3 (one per data type, no register variants)
| Variant | Opcode | Data Type | Assembly Notation |
|---|---|---|---|
| 1/3 | 0xFE7D | BY | BY CLEBI |
| 2/3 | 0xFE7E | H | H CLEBI |
| 3/3 | 0xFE7F | W | W CLEBI |
Operands¶
Operand 1 (Destination Operand)¶
The operand in which a bit will be cleared to 0. Only the specified bit is modified.
Type: BY, H, or W (determined by instruction prefix) Access: Write (read-modify-write)
Supported modes:
- LOCAL - Local variable
- RECORD - Record field
- REGISTER - Register (cannot use CONSTANT)
- PRE_INDEXED - Indexed addressing
- ABSOLUTE - Absolute memory address
Note: CONSTANT mode is not allowed for write operations.
Operand 2 (Bit Number)¶
The bit position to clear to 0 (0 = rightmost/LSB).
Type: Byte (signed) Access: Read
Supported modes:
- LOCAL - Local variable containing bit number
- RECORD - Record field containing bit number
- CONSTANT - Immediate bit number
- REGISTER - Register containing bit number
- PRE_INDEXED - Indexed addressing
- ABSOLUTE - Absolute memory address
Note: Bit number must be 0 <= bitno < (8, 16, or 32 depending on operand type).
Trap Conditions¶
- Addressing traps: Invalid address, page fault, protection violation
- Illegal operand value (IOV):
- Negative
<bit No.> <bit No.>>= bits in data type
- Negative
Data Status Bits¶
- Z (Zero): Set to 1 (always)
- S (Sign): Not affected
- O (Overflow): Not affected
- C (Carry): Not affected
Note: Z flag is always set to 1, distinguishing CLEBI from PUTBI.
Examples¶
Example 1: Clear register bit¶
% Clear bit N of word register R1
W CLEBI R1, N
% Bit N of R1 now 0, other bits unchanged
Example 2: Disable interrupt flag¶
% Disable interrupts by clearing bit 7 in control register
W CLEBI B.CTRL_REG, 7
% Bit 7 of B.CTRL_REG now cleared to 0
Example 3: Clear error flag¶
% Clear error flag (bit 3) in status word
W CLEBI B.STATUS, 3
Example 4: Clear bit in bitmap¶
% Mark resource as free in bitmap
% B.RESOURCE_ID contains the resource number
W1 := B.RESOURCE_ID
W2 := I1
W SHR I2, 5 % Divide by 32 for word index
W1 AND I1, 31 % Modulo 32 for bit position
W CLEBI B.BITMAP(I2), I1
Example 5: Clear multiple flags¶
% Clear various status flags
W CLEBI B.FLAGS, B.ERROR_BIT
W CLEBI B.FLAGS, B.BUSY_BIT
W CLEBI B.FLAGS, B.PENDING_BIT
Example 6: Mask implementation¶
% Clear specific bits to create a mask
W1 := -1 % All bits set
W CLEBI I1, 0 % Clear bit 0
W CLEBI I1, 15 % Clear bit 15
W CLEBI I1, 31 % Clear bit 31
% W1 now contains mask with holes at bits 0, 15, 31
Example 7: Conditional bit clear¶
% Clear ready bit if timeout occurred
W COMP B.TIMER, B.TIMEOUT
IF<GO NO_TIMEOUT
W CLEBI B.STATUS, B.READY_BIT
NO_TIMEOUT:
Performance Notes¶
- Typical cycles: 4-7 cycles depending on operand addressing modes
- Best case: 4 cycles (simple addressing)
- Worst case: 7+ cycles (complex indexed addressing with page fault)
Note: CLEBI is slightly more efficient than loading a 0 into a register and using PUTBI, as it doesn't require a register and performs the operation in a single instruction.
Bit numbering: Remember that ND-500 uses little-endian bit numbering - bit 0 is the LSB.
Atomicity: CLEBI is not atomic. In multi-processing environments, use synchronization primitives to protect shared flag variables.
Reference Manual¶
Section: §10.29 Title: Clear bit
See Also¶
- SETBI - Set bit to 1 unconditionally
- PUTBI - Put bit (clear from register value)
- GETBI - Get bit (extract bit into register)
- AND - Logical AND (can clear multiple bits with mask)
- Trap System