SETBI - Set Bit¶
Overview¶
Mnemonic: setbi
Function: Set bit to 1 unconditionally
Class: BITFIELD
Privilege: user
Format: t SETBI <operand/w/t>,<bit No./r/BY>
Description¶
Sets a specified bit in an operand to 1, regardless of its previous value. Only the specified bit is affected; all other bits in the operand remain unchanged.
Key Characteristics:
- Unconditional bit set operation (always sets to 1)
- Single-instruction bit manipulation (no register required)
- Supports 3 data types: BY (8-bit), H (16-bit), W (32-bit)
- More efficient than PUTBI for known bit sets
- All status flags cleared (Z, S, O, C all 0)
- Essential for flag enabling and hardware control
- Not atomic (requires synchronization in multiprocessor systems)
- Traps on out-of-range bit numbers
The bit number specifies which bit to set, with bit numbering following the ND-500 convention where bit 0 is the rightmost (least significant) bit. The operand can be a byte (BY), halfword (H), or word (W) data type.
Unlike PUTBI which stores a register bit value, SETBI unconditionally sets the target bit to 1. This makes it more efficient when you know you want to set a bit without first loading a register.
An illegal operand value trap (IOV) is triggered if:
<bit No.>is negative<bit No.>>= number of bits in the data type (8 for BY, 16 for H, 32 for W)
This instruction is essential for:
- Enabling flag bits
- Setting hardware control bits
- Implementing bit sets
- Marking status flags
Operands: 2 Variants: 3 opcode(s)
Variants¶
Total variants: 3 (one per data type, no register variants)
| Variant | Opcode | Data Type | Assembly Notation |
|---|---|---|---|
| 1/3 | 0xFE80 | BY | BY SETBI |
| 2/3 | 0xFE81 | H | H SETBI |
| 3/3 | 0xFE82 | W | W SETBI |
Operands¶
Operand 1 (Destination Operand)¶
The operand in which a bit will be set to 1. Only the specified bit is modified.
Type: BY, H, or W (determined by instruction prefix) Access: Write (read-modify-write)
Supported modes:
- LOCAL - Local variable
- RECORD - Record field
- REGISTER - Register (cannot use CONSTANT)
- PRE_INDEXED - Indexed addressing
- ABSOLUTE - Absolute memory address
Note: CONSTANT mode is not allowed for write operations.
Operand 2 (Bit Number)¶
The bit position to set to 1 (0 = rightmost/LSB).
Type: Byte (signed) Access: Read
Supported modes:
- LOCAL - Local variable containing bit number
- RECORD - Record field containing bit number
- CONSTANT - Immediate bit number
- REGISTER - Register containing bit number
- PRE_INDEXED - Indexed addressing
- ABSOLUTE - Absolute memory address
Note: Bit number must be 0 <= bitno < (8, 16, or 32 depending on operand type).
Trap Conditions¶
- Addressing traps: Invalid address, page fault, protection violation
- Illegal operand value (IOV):
- Negative
<bit No.> <bit No.>>= bits in data type
- Negative
Data Status Bits¶
- Z (Zero): Cleared (always 0)
- S (Sign): Cleared (always 0)
- O (Overflow): Cleared (always 0)
- C (Carry): Cleared (always 0)
Note: All status bits are unconditionally cleared, distinguishing SETBI from PUTBI.
Examples¶
Example 1: Enable interrupt flag¶
% Enable interrupts by setting bit 7 in control register
W SETBI B.CTRL_REG, 7
% Bit 7 of B.CTRL_REG now set to 1, other bits unchanged
Example 2: Set error flag¶
% Set error flag (bit 3) in status word
W SETBI B.STATUS, 3
Example 3: Mark bit in bitmap¶
% Mark resource as allocated in bitmap
% B.RESOURCE_ID contains the resource number
W1 := B.RESOURCE_ID
W2 := I1
W SHR I2, 5 % Divide by 32 for word index
W1 AND I1, 31 % Modulo 32 for bit position
W SETBI B.BITMAP(I2), I1
Example 4: Set multiple flags¶
% Set various status flags
W SETBI B.FLAGS, B.READY_BIT
W SETBI B.FLAGS, B.ENABLED_BIT
W SETBI B.FLAGS, B.INITIALIZED_BIT
Example 5: Set bit with ALT prefix¶
% Set FAILURE bit in word argument EXCEPTIONS on alternative domain
W SETBI ALT(IND(B.EXCEPTIONS)), FAILURE
Example 6: Conditional bit set¶
% Set error bit if error detected
W COMP B.RESULT, 0
IF>=GO NO_ERROR
W SETBI B.ERROR_FLAGS, B.OVERFLOW_BIT
NO_ERROR:
Performance Notes¶
- Typical cycles: 4-7 cycles depending on operand addressing modes
- Best case: 4 cycles (simple addressing)
- Worst case: 7+ cycles (complex indexed addressing with page fault)
Note: SETBI is slightly more efficient than loading a 1 into a register and using PUTBI, as it doesn't require a register and performs the operation in a single instruction.
Bit numbering: Remember that ND-500 uses little-endian bit numbering - bit 0 is the LSB.
Atomicity: SETBI is not atomic. In multi-processing environments, use synchronization primitives to protect shared flag variables.
Reference Manual¶
Section: §10.30 Title: Set bit