Skip to content

ALOG10 - Common Logarithm (log₁₀)

Overview

Mnemonic: alog10 Function: Common logarithm (base 10) Class: FLOAT_MATH Privilege: user

Format: tn ALOG10 <argument>


Description

Calculates the base 10 logarithm (common logarithm) of the argument and loads the result into the specified float or double float register.

Operation:

Fn/Dn = log₁₀(<argument>)

Key Characteristics:

  • Hardware-accelerated common logarithm (base 10)
  • Argument must be positive (> 0)
  • IVO trap on non-positive argument (result = -5.8×10⁷⁶)
  • Essential for pH, decibels, Richter scale
  • 8 register variants (F1-F4, D1-D4)
  • 180-220 cycles (complex transcendental function)
  • Common in scientific and engineering calculations
  • Z flag set when result = 0 (e.g., log₁₀(1) = 0)
  • Result loaded into specified float/double register

The argument must be positive (> 0). Zero or negative values cause an invalid operation (IVO) trap condition and the result is set to -5.8×10⁷⁶ (largest negative floating point number).

The common logarithm is widely used in science and engineering for pH calculations, decibel measurements, Richter scale (earthquakes), sound intensity, and scientific notation. If y = log₁₀(x), then x = 10ʸ.

Operands: 1 Variants: 8 opcode(s)


Variants

Total variants: 8 (2 data types × 4 registers)

Variant Opcode Prefix Register Data Type
1/8 0xFF80 F 1 Float
2/8 0xFF81 F 2 Float
3/8 0xFF82 F 3 Float
4/8 0xFF83 F 4 Float
5/8 0xFFAC D 1 Double Float
6/8 0xFFAD D 2 Double Float
7/8 0xFFAE D 3 Double Float
8/8 0xFFAF D 4 Double Float

Operands

Operand 1 (Argument)

The argument operand containing the value to take the common logarithm of (must be > 0).

Type: Float or Double Float (matching register type) Access: Read

Supported modes:

  • LOCAL - Local data area access (B.variable)
  • RECORD - Record-relative access (R.field)
  • CONSTANT - Immediate constant value
  • REGISTER - Float register (A1-A4 or D1-D4)
  • PRE_INDEXED - Indexed addressing with offset
  • ABSOLUTE - Absolute memory address

Trap Conditions

  • Addressing traps: Invalid address, descriptor range violation, page fault, protection violation
  • Invalid operation (IVO): Argument ≤ 0; result set to -5.8×10⁷⁶

Data Status Bits

  • Z (Zero): Set if result = 0, cleared otherwise (e.g., log₁₀(1) = 0)
  • S (Sign): Set to sign bit of result (bit 31 for float, bit 63 for double)
  • O (Overflow): Unaffected
  • K (Flag): Unaffected
  • C (Carry): Unaffected

Examples

Example 1: Common logarithm from variable

        % Load common logarithm of BIGNUMB
        F4 ALOG10 BIGNUMB

Example 2: pH calculation

        % Calculate pH = -log10([H+])
        F1 ALOG10 B.H_CONCENTRATION
        F1 NEG                   % Negate to get pH
        F1 =: B.PH_VALUE

Example 3: Decibel calculation

        % Calculate dB = 10 * log10(P/P0)
        F2 := B.POWER
        F2 / B.REFERENCE_POWER   % P/P0
        F2 ALOG10 F2             % log10(P/P0)
        F2 * 10.0                % 10 * log10(P/P0)
        F2 =: B.DECIBELS

Example 4: Order of magnitude

        % Find order of magnitude of a number
        D1 ALOG10 B.VALUE
        D1 INT D1                % Truncate to integer
        D1 =: B.ORDER_OF_MAG
        % e.g., 1234 -> log10(1234) = 3.09... -> 3

Performance Notes

  • Typical cycles: 180-220 cycles (complex transcendental function)
  • Best case: ~180 cycles (simple argument values)
  • Worst case: ~220 cycles (complex argument values, table lookup + polynomial approximation)

Note: Logarithmic functions are significantly slower than basic arithmetic operations due to table lookup and polynomial approximation algorithms.


Reference Manual

Section: §12.15 Title: Common logarithm


See Also