BYCONV - Convert to Byte¶
Overview¶
Mnemonic: byconv
Function: Convert source operand to 8-bit byte
Class: FLOAT_MATH
Privilege: user
Format: t1 BYCONV <source/r/t1>,<dest/w/BY>
Description¶
Converts a source operand of any supported type (BI, H, W, F, D) to 8-bit byte (integer) format and stores the result in the destination.
Operation:
<dest> = (byte)<source>
Key Characteristics:
- Type converter to 8-bit signed integer
- 5 source types supported (BI, H, W, F, D)
- Zero extension for bit (BI)
- Truncation with overflow check for larger integers
- Float conversions use truncation (round toward zero)
- IOV trap when value outside range (-128 to 127)
- Essential for character and string processing
- Integer conversions fast (5-7 cycles), float slower (8-10 cycles)
- Narrowest integer conversion (high overflow risk)
The conversion handles:
- Bit to byte: Zero extension (BI → BY)
- Larger integers to byte: Truncation with overflow check (H/W → BY)
- Float/double to byte: Rounding toward zero with range check
- Identity: Byte to byte is a simple copy
If the source value is outside the representable range of an 8-bit signed integer (-128 to 127), an illegal operand value (IOV) trap occurs.
This instruction is essential for:
- Packing data into 8-bit fields
- Character/string processing
- Interface with 8-bit data structures
- Type casting in high-level languages
Operands: 2 Variants: 5 opcode(s)
Variants¶
Total variants: 5 (one per source type)
| Variant | Opcode | Source Type | Dest Type | Assembly Notation |
|---|---|---|---|---|
| 1/5 | 0xFD44 | BI | BY | BI BYCONV |
| 2/5 | 0xFD4F | H | BY | H BYCONV |
| 3/5 | 0xFD54 | W | BY | W BYCONV |
| 4/5 | 0xFD59 | F | BY | F BYCONV |
| 5/5 | 0xFD5E | D | BY | D BYCONV |
Operands¶
Operand 1 (Source)¶
Source value to convert.
Type: BI, H, W, F, or D (determined by instruction prefix) Access: Read
Supported modes: LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE
Operand 2 (Destination)¶
Destination for converted 8-bit byte value.
Type: BY (byte) Access: Write
Supported modes: LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE
Trap Conditions¶
- Addressing traps: Invalid address, page fault, protection violation
- Illegal operand value (IOV): Source value outside byte range (-128 to 127)
Data Status Bits¶
- Z (Zero): Set if result = 0
- S (Sign): Set to sign bit of result
- O (Overflow): Set on conversion overflow
- C (Carry): Not affected
Examples¶
Example 1: Convert word to byte¶
% Convert word to byte, check for overflow
W BYCONV I1, B.BYTE_VAL
IF-KGO CONV_OK
% Value too large for byte
CALL OVERFLOW_HANDLER
CONV_OK:
Example 2: Float to byte conversion¶
% Convert float percentage to byte (0-100)
F BYCONV B.PERCENT, R.BYTE_PERCENT
Example 3: Store character¶
% Store ASCII character code
W BYCONV I1, B.STRING(I2)
Performance Notes¶
- Typical cycles: 5-10 cycles
- Integer conversions: 5-7 cycles
- Float conversions: 8-10 cycles
Reference Manual¶
Section: §15.2 Title: Data type conversion