FCONV - Convert to Float¶
Overview¶
Mnemonic: fconv
Function: Convert source operand to 32-bit IEEE 754 float
Class: FLOAT_MATH
Privilege: user
Format: t1 FCONV <source/r/t1>,<dest/w/F>
Description¶
Converts a source operand of any supported type (BI, BY, H, W, D) to 32-bit IEEE 754 single-precision floating-point format and stores the result in the destination.
Operation:
<dest> = (float)<source>
Key Characteristics:
- Type converter to IEEE 754 single-precision float
- 5 source types supported (BI, BY, H, W, D)
- Exact conversion for integers ≤ 2²⁴
- Precision loss for large integers and double downcasts
- Rounding to nearest representable float value
- IOV trap when double outside float range
- Essential for mixed precision arithmetic
- 7-12 cycles (integer 7-9, double 10-12)
- Interface with 32-bit float APIs
The conversion handles:
- Integer to float: Exact conversion for values within float precision
- Double to float: Rounding to nearest representable float value
- Identity: Float to float is a simple copy
Precision loss may occur when converting:
- Integers larger than 2²⁴ (float mantissa has only 24 bits)
- Double values requiring more precision than single precision
An illegal operand value (IOV) trap occurs if the source double value is outside the representable float range.
This instruction is essential for:
- Mixed precision arithmetic
- Converting integers to floating-point
- Downcasting from double precision
- Interface with 32-bit float APIs
Operands: 2 Variants: 5 opcode(s)
Variants¶
Total variants: 5 (one per source type)
| Variant | Opcode | Source Type | Dest Type | Assembly Notation |
|---|---|---|---|---|
| 1/5 | 0xFD47 | BI | F | BI FCONV |
| 2/5 | 0xFD4C | BY | F | BY FCONV |
| 3/5 | 0xFD51 | H | F | H FCONV |
| 4/5 | 0xFD56 | W | F | W FCONV |
| 5/5 | 0xFD61 | D | F | D FCONV |
Operands¶
Operand 1 (Source)¶
Source value to convert.
Type: BI, BY, H, W, or D (determined by instruction prefix) Access: Read
Supported modes: LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE
Operand 2 (Destination)¶
Destination for converted 32-bit float value.
Type: F (float) Access: Write
Supported modes: LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE
Trap Conditions¶
- Addressing traps: Invalid address, page fault, protection violation
- Illegal operand value (IOV): Double value outside float range
Data Status Bits¶
- Z (Zero): Set if result = 0.0
- S (Sign): Set if result is negative
- O (Overflow): Set on conversion overflow
- C (Carry): Not affected
Examples¶
Example 1: Convert integer to float¶
% Convert word integer to float for calculation
W FCONV I1, B.FLOAT_RESULT
F MUL B.FLOAT_RESULT, 3.14159, B.FINAL
Example 2: Downcast double to float¶
% Convert double to single precision
D FCONV B.DOUBLE_VAL, B.FLOAT_VAL
Example 3: Mixed precision arithmetic¶
% Convert byte count to float for percentage calc
BY FCONV B.COUNT, E1
F DIV E1, B.TOTAL, E1
F MUL E1, 100.0, B.PERCENTAGE
Performance Notes¶
- Typical cycles: 7-12 cycles
- Integer to float: 7-9 cycles (conversion + normalization)
- Double to float: 10-12 cycles (rounding logic)
Reference Manual¶
Section: §15.2 Title: Data type conversion