Skip to content

INIT - Initialize Stack

Overview

Mnemonic: init Function: Initialize stack frame Class: CONTROL Privilege: user

Format: INIT <bottom_of_stack>, <main_demand>, <total_demand>


Description

Initializes the system stack by setting up the base register (B), stack pointer (SP), and top-of-stack register (TOS) according to the three operands. This instruction is typically executed once at program startup to establish the stack environment for the main program.

Key Characteristics:

  • Single-instruction stack initialization (replaces ~6 operations)
  • Sets B, TOS, L registers and stack frame fields
  • Automatic overflow detection (trap if main_demand >= total_demand)
  • Essential for program startup and context creation
  • Initializes both main and system stack spaces
  • Clears linkage fields (PREVB, RETA) for clean startup
  • Prevents stack corruption via demand validation
  • Typically first instruction in main program

The instruction performs the following operations:

  1. Loads B register with bottom-of-stack address
  2. Sets TOS = bottom_of_stack + total_system_demand
  3. Sets B.SP = bottom_of_stack + main_program_demand
  4. Clears B.PREVB (previous base) = 0
  5. Clears B.RETA (return address) = 0
  6. Clears L register = 0

Stack Layout After INIT:

[Bottom of stack] ← B register
[Main program stack space] (size = main_demand)
[Main program SP] ← B.SP
[Additional stack space] (size = total_demand - main_demand)
[Top of stack] ← TOS register

Trap Prevention: If main_demand >= total_demand, a stack overflow trap (STO) occurs immediately, preventing stack corruption.

Common Use Cases:

  • Program initialization (first instruction in main)
  • Creating new execution contexts
  • Stack frame setup for isolated tasks
  • Testing/debugging with controlled stack environments

Operands: 3 Variants: 1 opcode


Variants

Variant Opcode Assembly Notation
1/1 0x00DC INIT

Operands

Operand 1 (Bottom of Stack, Read):

  • Addressing modes: LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE
  • Data type: Word (W)
  • Role: 4-byte absolute address of stack bottom

Operand 2 (Main Program Demand, Read):

  • Addressing modes: LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE
  • Data type: Word (W)
  • Role: Stack space required by main program (bytes)

Operand 3 (Total System Demand, Read):

  • Addressing modes: LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE
  • Data type: Word (W)
  • Role: Total stack space (main + system, bytes)

Result: Registers B, TOS, L initialized; B.SP, B.PREVB, B.RETA set


Trap Conditions

  • Addressing traps: Invalid address or protection violation
  • Stack overflow (STO): main_demand >= total_demand

Data Status Bits

All flags unaffected


Examples

Example 1: Standard program initialization

% Initialize stack at program start
MAIN:
        INIT STACK_BASE, 4096, 16384
        % Stack: 4KB for main, 16KB total
        % Continue with main program

Example 2: Using symbolic constants

% Define stack parameters
STACK_BASE     EQU 0x100000    % 1MB base address
MAIN_STACK     EQU 0x1000      % 4KB for main
TOTAL_STACK    EQU 0x4000      % 16KB total

PROGRAM_START:
        INIT STACK_BASE, MAIN_STACK, TOTAL_STACK

Example 3: Dynamic stack allocation

% Allocate stack at runtime
        W1 MOVE HEAP_PTR, I1     % Get heap address
        INIT I1, 8192, 32768     % 8KB main, 32KB total

Example 4: Minimal stack for simple program

% Small stack for simple task
        INIT SMALL_STACK, 256, 1024
        % 256 bytes for main, 1KB total

Example 5: Validating stack demand

% Check before initializing
        W1 COMP MAIN_DEMAND, TOTAL_DEMAND
        IF>=GO STACK_ERROR      % main >= total would trap
        INIT STACK_ADDR, MAIN_DEMAND, TOTAL_DEMAND

Example 6: Multi-context system

% Initialize separate stacks for different tasks
TASK1_INIT:
        INIT TASK1_STACK, 2048, 8192
        % Task 1 stack initialized

TASK2_INIT:
        INIT TASK2_STACK, 2048, 8192
        % Task 2 stack initialized

Example 7: Embedded system boot

% Boot sequence with fixed memory layout
BOOT:
        INIT 0x10000, 0x800, 0x2000
        % Stack at 64KB, 2KB main, 8KB total
        CALL SYSTEM_INIT

Performance Notes

  • Execution: Single instruction replaces multiple register loads
  • Safety: Automatic overflow detection prevents stack corruption
  • Typical Use: Called once per program/context, not performance-critical
  • Stack Size: Choose total_demand carefully based on call depth and local variables
  • Alignment: Stack base should be word-aligned for optimal performance

Reference Manual

Section: §13.9 Title: Initialize stack


See Also

  • ENTB - Enter block (pushes new stack frame)
  • RETB - Return from block (pops stack frame)
  • CALL - Call subroutine