Skip to content

SETK - Set K Flag

Overview

Mnemonic: setk Function: Set K status flag bit Class: CONTROL Privilege: user

Format: SETK


Description

Sets the K (user flag) bit in the CPU status register to 1. The K flag is a general-purpose user flag that can be set, cleared, and tested by software for application-specific purposes. Unlike other status bits (Z, S, C, V) which are set automatically by arithmetic/logical operations, the K bit is entirely under software control.

Operation:

K flag = 1

Key Characteristics:

  • User-controlled flag (not set by arithmetic operations)
  • Single-cycle execution (very fast)
  • Cannot trap (always succeeds)
  • Independent of other flags (Z, S, C, V unchanged)
  • Paired with CLRK (clear) and IFKGO/IF-KGO (test)
  • Essential for custom control flow and state tracking
  • Common in subroutine return status (RETK uses K=1 for success)
  • Useful for boolean state across operations

K Flag Uses:

  • Custom Condition Flags: Storing boolean state across operations
  • Semaphores/Locks: Simple synchronization primitive
  • State Machines: Tracking current state in algorithms
  • Error Indicators: Marking error conditions in subroutines
  • Feature Flags: Enabling/disabling optional behavior
  • Communication: Passing single-bit information between routines
  • Loop Control: Custom loop termination conditions (with IFKGO)

The K bit can be tested with conditional branches like IFKGO (if K set, goto) and IF-KGO (if K clear, goto), making it useful for custom control flow patterns not directly supported by standard comparison flags.

Operands: 0 Variants: 1 opcode


Variants

Variant Opcode Assembly Notation
1/1 0xFE02 SETK

Operands

None: Operates directly on K bit in status register.

Result: K flag bit = 1


Trap Conditions

None: This instruction cannot trap


Data Status Bits

  • K (User flag): Set to 1
  • Z, S, C, V: Unaffected

Examples

Example 1: Set error flag

% Mark error condition
VALIDATE:
        W1 COMP INPUT, MAX
        IF>GO SET_ERROR
        CLRK              % Clear error flag
        RET
SET_ERROR:
        SETK              % Set error flag
        RET

Example 2: Simple semaphore

% Acquire lock
ACQUIRE_LOCK:
        IFKGO LOCKED      % If K=1, lock already held
        SETK              % Set lock
        % Critical section
        RET
LOCKED:
        % Wait or handle contention

Example 3: Feature toggle

% Enable optional feature
        SETK              % K=1 means feature enabled

PROCESS:
        % Do main work
        IFKGO DO_OPTIONAL % If K set, do optional work
        RET
DO_OPTIONAL:
        % Optional feature code
        RET

Example 4: State machine

% Two-state machine (K=0: idle, K=1: active)
IDLE_STATE:
        % Wait for event
        IF=GO EVENT_OCCURRED
        RET
EVENT_OCCURRED:
        SETK              % Enter active state
        GO ACTIVE_STATE

ACTIVE_STATE:
        % Process while active
        IF=GO DONE
        RET
DONE:
        CLRK              % Return to idle
        GO IDLE_STATE

Example 5: Subroutine success indicator

% Return success/failure via K flag
OPEN_FILE:
        % Try to open file
        W1 COMP RESULT, 0
        IF<GO OPEN_FAILED
        SETK              % Success: K=1
        RET
OPEN_FAILED:
        CLRK              % Failure: K=0
        RET

% Caller checks K flag
        CALL OPEN_FILE
        IFKGO FILE_OPENED
        % Handle failure

Example 6: Loop termination with custom condition

% Process until K flag set (by external event/interrupt)
        CLRK              % Clear flag initially
LOOP:
        % Process work
        IFKGO DONE        % Exit if K set
        GO LOOP
DONE:

Example 7: Boolean result passing

% Set K based on complex condition
CHECK_CONDITION:
        W1 COMP A, B
        IF<>GO NOT_EQUAL
        W2 COMP C, D
        IF<>GO NOT_EQUAL
        SETK              % Both equal: K=1
        RET
NOT_EQUAL:
        CLRK              % At least one not equal: K=0
        RET

Performance Notes

  • Size: 2 bytes (single-word instruction)
  • Execution: 1 cycle (direct status register write)
  • No Side Effects: Only K bit modified, all other state preserved
  • vs Other Flags: K is the only user-controlled flag (Z/S/C/V are automatic)
  • Typical Use: Infrequent - mainly for special-purpose control flow

Reference Manual

Section: §15.11 Title: Set flag


See Also

  • CLRK - Clear K flag
  • IFKGO - Branch if K flag set
  • IF-KGO - Branch if K flag clear