SET1 - Set to One¶
Overview¶
Mnemonic: set1
Function: Set operand to constant value 1
Class: CONTROL
Privilege: user
Format: t SET1 <operand>
Description¶
Replaces the contents of the destination operand with the value one (1). This instruction provides a convenient shorthand for initialization and counter setup. All data status bits are cleared after execution.
Operation:
1 → <operand>
Key Characteristics:
- Sets operand to exactly 1
- Works with all data types: BI, BY, H, W, F, D
- All status flags cleared
- Single operand instruction
- Efficient for loop counter initialization
- Float/double get 1.0 value
Common Use Cases:
- Loop counter initialization
- Boolean flag setting
- Reset counters to 1
- Initialize accumulators
- Set iteration start value
Operands: 1 (destination, write-only) Variants: 6 opcodes (one per data type)
Examples¶
Example 1: Initialize loop counter¶
% Start loop at 1
W1 SET1 B.COUNTER
LOOP: % Loop body
W1 ADD 1, B.COUNTER
W1 COMP 10, B.COUNTER
IF<=GO LOOP
Explanation: Initialize loop counter to 1 instead of 0.
Example 2: Set float to 1.0¶
% Initialize float multiplier
F SET1 IND(B.START)
% F register indirectly sets value to 1.0
Explanation: Set floating-point argument to 1.0.
Example 3: Boolean flag¶
% Mark as active/true
BY SET1 ACTIVE_FLAG
% Check later
BY COMP 1, ACTIVE_FLAG
IF=GO IS_ACTIVE
Explanation: Use 1 as true value for boolean flag.
Example 4: Reset counter¶
% Reset iteration counter
W SET1 RETRY_COUNT
% Start retry loop
Explanation: Reset counter to initial value of 1.
Example 5: Initialize array element¶
% Set array entry to 1
W2 MOVE INDEX
H SET1 ARRAY(W2)
Explanation: Initialize indexed array element to 1.
Trap Conditions¶
- Addressing traps: Invalid operand address
Data Status Bits¶
- All cleared: Z=0, S=0, C=0, V=0, all flags cleared
Reference Manual¶
Section: §10.18 Title: Set to one