Skip to content

154B AssignCAMACLAM

Stub   MON 154B (108 decimal) · Mnemonic ASSIG · Group: Device Handling (manual section 2.11)

Available from: RT programs (manual compatibility box)

Emulation source: src/handlers/mon_154B_AssignCAMACLAM.c

Description

Assigns a graded LAM in the CAMAC identification table to a logical device number in the logical number table. See CAMACFunction and CAMACGLRegister for more details.

Notes

  • Remove the LAM by specifying logical device number -1.

Parameters

Name Type Direction Description
DeviceNumber INTEGER In Logical device number. See appendix B.
GradedLAMNumber INTEGER In Graded LAM number. Use 0 for high priority on interrupt level 13.
CrateNumber INTEGER In CAMAC crate number in the range 0:15.

Direction: In = the program supplies the value, Out = the call returns it, In/Out = both.

See also

CAMACFunction, BCNAFCAMAC, BCNAF1CAMAC, CAMACIOInstruction, CAMACGLRegister

Compatibility

Machines Users Programs
ND-100 and ND-500 User RT and user SYSTEM RT programs

The manual's compatibility box for this call, word for word.

Yes/no fields from the YAML extraction (not in the manual's words):

ND-100 ND-500 User programs RT programs System programs
Yes Yes Yes Yes No

Examples

From the manual (OCR text, not corrected).

INTEGER : DeviceNo, GradedLAMNumber, CrateNo
...
ON ROUTINEERROR DO
    IF ErrCode >< 0 THEN ...
ENDON
Monitor_Call('AssignCAMACLAM', DeviceNo, GradedLAMNumber, CrateNo)
INTEGER DeviceNo, GradedLAMNumber, CrateNo
...
Monitor Call('AssignCAMACLAM', DeviceNo, GradedLAMNumber, CrateNo)
IF (ErrCode .NE. 0) THEN ...
DeviceNumber, GradedLAMNumber, CrateNumber : INTEGER2;
...
AssignCAMACLAM(DeviceNumber, GradedLAMNumber, CrateNumber);
IF ErrCode <> 0 THEN ...
01 DeviceNo COMP.
01 GradedLAMNumber COMP.
01 CrateNo COMP.
01 ErrCode COMP.
...
MONITOR-CALL "AssignCAMACLAM" USING DeviceNo, GradedLAMNumber, CrateNo.
CALL "CbError" USING ErrCode.
IF ErrCode NOT = 0 GO ...
DeviceNo : W BLOCK 1
GradedLAMNumber : W BLOCK 1
CrateNo : W BLOCK 1
ErrCode : W BLOCK 1
AssignCAMACLAM : EQU 37B9 + 154B
...
CALLG AssignCAMACLAM, 3, DeviceNo, GradedLAMNumber, CrateNo
    IF K GO ERROR
...
ERROR : W1 =: ErrCode              %ErrorCode in W1 register.
LDT GRLAM      %Graded LAM.
LDA CRATE      %Crate number.
COPY SA DD
LDA DEVNO      %Logical device number.
MON 154        %Monitor call AssignCAMACLAM.
JAN ERROR      %Error if register A is negative.
...
ERROR, ...     %Error number in register A.
...
GRLAM, ...
DEVNO, ...
CRATE, ...

ndmonlib implementation

Stub Registered MON_STATUS_NOT_IMPLEMENTED: the handler is a stub. mon_dispatch() in src/core/mon_dispatch.c reports the call as unimplemented without calling it.

Handler mon_154B_AssignCAMACLAM
Code lines 8 (non-blank, non-comment lines in the file)

Source

SINTRAN III Monitor Calls (ND-860228.2 EN), page 104.