21B InUpTo8Bytes¶
Stub MON 21B (17 decimal) · Mnemonic M8INB · Group: Input and Output Monitor Calls (manual section 2.5)
Available from: All programs (manual compatibility box)
Emulation source: src/handlers/mon_21B_InUpTo8Bytes.c
Description¶
See also In8Bytes, InByte, InString, In4x2Bytes, and Out8Bytes.
Parameters¶
| Name | Type | Direction | Description |
|---|---|---|---|
DeviceNumber |
INTEGER2 | In | Logical device number. See appendix B. |
NoOfBytes |
INTEGER2 | Out | Number of bytes read (output). For word-oriented devices, returns word count. |
InData |
BYTES[8] | Out | The 8 bytes of input data (output). |
Direction: In = the program supplies the value, Out = the call returns it, In/Out = both.
See also¶
In8Bytes, InByte, InString, In4x2Bytes, and Out8Bytes
Compatibility¶
| Machines | Users | Programs |
|---|---|---|
| ND-100 and ND-500 | All users | All programs |
The manual's compatibility box for this call, word for word.
Yes/no fields from the YAML extraction (not in the manual's words):
| ND-100 | ND-500 | User programs | RT programs | System programs |
|---|---|---|---|---|
| Yes | Yes | Yes | Yes | No |
Examples¶
From the manual (OCR text, not corrected).
INTEGER : DeviceNumber, NoOfBytes
BYTES : InData(0:7)
...
ON ROUTINEERROR DO
IF ErrCode > 0 THEN ...
ENDON
Monitor_Call('InUpTo8Bytes', DeviceNumber, NoOfBytes, InData)
INTEGER DeviceNumber, NoOfBytes
CHARACTER InData*8
...
Monitor_Call('InUpTo8Bytes', DeviceNumber, NoOfBytes, InData(1:8))
IF (ErrCode .NE. 0) THEN ...
DeviceNumber, NoOfBytes : INTEGER2;
InData : RECORD...END;
...
InUpTo8Bytes(DeviceNumber, NoOfBytes, InData);
IF ErrCode <> 0 THEN ...
01 DeviceNumber COMP.
01 NoOfBytes COMP.
01 InData PIC X(8).
01 ErrCode COMP.
...
MONITOR-CALL "InUpTo8Bytes" USING DeviceNumber, NoOfBytes, InData.
CALL "CbError" USING ErrCode.
IF ErrCode NOT = 0 GO ...
DeviceNumber : W BLOCK 1
NoOfBytes : W BLOCK 1
InData : STRING 8
ErrCode : W BLOCK 1
InUpTo8Bytes : EQU 37B9 + 21B
...
CALLG InUpTo8Bytes, 3, DeviceNumber, NoOfBytes, InData
IF K GO ERROR
...
ERROR : W1 =: ErrCode %ErrorCode in W1 register.
LDT DEVNO %Logical device number.
MON 21 %Monitor call InUpTo8Bytes.
JMP ERROR %Error return from monitor call.
STD BYTES %Normal return, store first 4 bytes read.
COPY SL DA
STA BYTES+2 %Store next 2 bytes read.
STX BYTES+3 %Store last 2 bytes read.
STT COUNT %Store number of bytes (or words) read.
...
ERROR, ... %Error number in register A.
...
DEVNO, ...
COUNT, 0
BYTES, 0
0
0
0
ndmonlib implementation¶
Stub Registered MON_STATUS_NOT_IMPLEMENTED: the handler is a stub. mon_dispatch() in src/core/mon_dispatch.c reports the call as unimplemented without calling it.
| Handler | mon_21B_InUpTo8Bytes |
| Code lines | 6 (non-blank, non-comment lines in the file) |
Source¶
SINTRAN III Monitor Calls (ND-860228.2 EN), page 325.