Skip to content

52B TerminalMode

Validated   MON 52B (42 decimal) · Mnemonic TERMO · Group: Monitor Calls for Terminal Handling (manual section 2.6)

Available from: Background programs (manual compatibility box)

Emulation source: src/handlers/mon_52B_TerminalMode.c

Description

Selects various terminal functions. You may stop output on full page. Input may be converted to uppercase letters. A delay after carriage return can be set. You may also set automatic logout if the line between the terminal and the computer is broken.

  • Terminal mode can also be set on TADs.

Parameters

Name Type Direction Description
DeviceNumber INTEGER In Logical device number of the terminal. See appendix B. Use 1 for your own terminal.
Mode INTEGER In Terminal mode (0-15):
Bit 0: Capital letters (1=yes)
Bit 1: Delay after return (1=yes)
Bit 2: Stop on full page (1=yes)
Bit 3: Auto-logout on line break (1=yes for modes 8-15)

Direction: In = the program supplies the value, Out = the call returns it, In/Out = both.

See also

GetTerminalMode, @TERMINAL-MODE

Compatibility

Machines Users Programs
ND-100 and ND-500 All users Background programs

The manual's compatibility box for this call, word for word.

Yes/no fields from the YAML extraction (not in the manual's words):

ND-100 ND-500 User programs RT programs System programs
Yes Yes No No No

Examples

From the manual (OCR text, not corrected).

INTEGER : DeviceNumber, Mode

...

ON ROUTINEERROR DO

    IF ErrCode > 0 THEN ...

ENDON

Monitor_Call('TerminalMode', DeviceNumber, Mode)
INTEGER DeviceNumber, Mode
...
Monitor_Call('TerminalMode', DeviceNumber, Mode)
If (ErrCode .NE. 0) THEN ...
DeviceNumber, Mode : INTEGER2;
...
TermMode(DeviceNumber, Mode);   \[Note routine name.\]
IF ErrCode <> 0 THEN ...
01 DeviceNumber COMP. 01 Mode COMP.
01 ErrCode COMP.
MONITOR-CALL "TerminaIMode" USING DeviceNumber, Mode.
CALL "CbError" USING ErrCode.
IF ErrCode NOT = 0 GO ...
DeviceNumber : W BLOCK 1
Mode : W BLOCK 1
ErrCode : W BLOCK 1
TerminalMode : EQU 37B9 + 52B
...
CALLG TerminalMode, 2, DeviceNumber, Mode
IF K GO ERROR
...
ERROR : W1 =: ErrCode &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;%ErrorCode in W1 register.
LDA (PAR &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;%Load register A with address of parameter list.
MON 52 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;%Monitor call TerminalMode.
JAF ERROR &nbsp;%Handle error if register A is non-zero.
...
ERROR, ... &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;%Error number in register A.
...
PAR, DEVNO &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;%Logical device number.
MODE &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;%Communication mode.
...
DEVNO, ...
MODE, ...

ndmonlib implementation

Validated Registered MON_STATUS_VALIDATED in src/core/mon_registry.c: implemented, tested and working.

Handler mon_52B_TerminalMode
Code lines 20 (non-blank, non-comment lines in the file)

Source

SINTRAN III Monitor Calls (ND-860228.2 EN), page 533.