Skip to content

343B Configuration

Not registered   MON 343B (227 decimal) · Mnemonic CONFG · Group: Monitor Calls for Internal Use (manual section 2.14)

Available from: not known - no compatibility box captured from the manual

Emulation source: none - not registered in ndmonlib

Description

System configuration read/write (manual sections 2.14 and 2.17, short name CONFG). Indexed configuration access with 6 sub-functions. Internal-use call; contract is RE-derived from the labelled handler body.

Notes

  • Version history: L-version defined five new configuration parameters, numbers 51B-55B (and extended parameter 41B) (ND-860230-6-EN Sintran III - Release Information - L-Version.md:1319). N-version extended configuration parameter 52B by introducing a new subparameter number 10B (SUBIN); the older subparameters are unchanged (ND-860230-8-EN SINTRAN III - Release Information - N-version.md:1015, 1058-1070).
  • Internal-use monitor call (manual sections 2.14 / 2.17); not intended for user programs.
  • Handler MNCFG at RP-P2-CONFG.NPL:220 - indexed configuration read/write, 6 sub-functions. VERIFIED (labelled handler body read).
  • Sub-functions are selected by an index; the exact caller convention (register/CALLG mapping) is not confirmed from the available source.

Parameters

Name Type Direction Description
SubFunction INTEGER In UNVERIFIED - configuration sub-function index (one of 6 read/write functions). Exact caller convention not confirmed from the available source.

Direction: In = the program supplies the value, Out = the call returns it, In/Out = both.

Compatibility

ND-100 ND-500 User programs RT programs System programs
Yes No No No Yes

From the YAML extraction; this call's page in the manual had no compatibility box that was captured.

ndmonlib implementation

Not registered Not registered in src/core/mon_registry.c. mon_dispatch() reports the call as unimplemented.

Source

Reverse-engineered from SINTRAN III NPL source + ND-860228-2-EN manual (sections 2.14 / 2.17).