402B GetInputFlags¶
Stub MON 402B (258 decimal) · Mnemonic RFLAG · Group: Not grouped in manual
Available from: All programs (manual compatibility box)
Emulation source: src/handlers/mon_402B_GetInputFlags.c
Description¶
ND-100 and ND-500 programs may communicate through two 32-bit flag arrays. You can use the flags as you wish. GetInputFlags reads the input flags. The ND-100 sets these flags with the monitor call ND500Function. See the manual ND Linker User Guide and Reference Manual (ND-860289).
- You get the last values written to the flags. There is no queue.
Parameters¶
| Name | Type | Direction | Description |
|---|---|---|---|
Value |
INTEGER4 | Out | Flag values as a 32-bit integer. |
Direction: In = the program supplies the value, Out = the call returns it, In/Out = both.
See also¶
SetOutputFlags, ND500Function
Compatibility¶
| Machines | Users | Programs |
|---|---|---|
| ND-500 | All users | All programs |
The manual's compatibility box for this call, word for word.
Yes/no fields from the YAML extraction (not in the manual's words):
| ND-100 | ND-500 | User programs | RT programs | System programs |
|---|---|---|---|---|
| No | Yes | No | No | No |
Examples¶
From the manual (OCR text, not corrected).
INTEGER : Value
...
Monitor_Call('GetInputFlags', Value)
INTEGER Value
...
Monitor_Call('GetInputFlags', Value)
Value : LONGINT;
...
GetInputFlags(Value);
01 Value COMP.
...
MONITOR-CALL "GetInputFlags" USING Value.
Value : W BLOCK 1
GetInputFlags : EQU 37B9 + 402B
...
CALLG GetInputFlags, 1, Value
ndmonlib implementation¶
Stub Registered MON_STATUS_NOT_IMPLEMENTED: the handler is a stub. mon_dispatch() in src/core/mon_dispatch.c reports the call as unimplemented without calling it.
| Handler | mon_402B_GetInputFlags |
| Code lines | 5 (non-blank, non-comment lines in the file) |
Source¶
SINTRAN III Monitor Calls (ND-860228.2 EN), page 251.