324B OctobusFunction¶
Stub MON 324B (212 decimal) · Mnemonic OCTIO · Group: Not grouped in manual
Available from: All programs (manual compatibility box)
Emulation source: src/handlers/mon_324B_OctobusFunction.c
Description¶
Performs various functions on an old Octobus (earlier than version 3).
Parameters¶
| Name | Type | Direction | Description |
|---|---|---|---|
FunctionCode |
INTEGER2 | In | Function number: 0=kick, 1=wait for kick, 5=read Octobus status, 6=Who am I. |
DeviceNo |
INTEGER2 | In | Logical device number. |
Parameter |
INTEGER2 | In/Out | Function dependent parameter. Function 0 returns destination station. Function 5/6 return status value. |
Direction: In = the program supplies the value, Out = the call returns it, In/Out = both.
Compatibility¶
| Machines | Users | Programs |
|---|---|---|
| ND-100 and ND-500 | All users | All programs |
The manual's compatibility box for this call, word for word.
Yes/no fields from the YAML extraction (not in the manual's words):
| ND-100 | ND-500 | User programs | RT programs | System programs |
|---|---|---|---|---|
| Yes | Yes | No | No | No |
Examples¶
From the manual (OCR text, not corrected).
| Parameter | Type | Block | Description |
|-------------|----------|-------|-------------------------------------------------|
| Func | W | BLOCK 1 | |
| DevNo | W | BLOCK 1 | |
| Par3 | W | BLOCK 1 | May be destination station or return value. |
| Status | W | BLOCK 1 | |
| OctobusFunction | EQU | 37B9 + 324B | |
CALLG OctobusFunction, 3, Func, DevNo, Par3
IF K GO Error
W1 =: Status
...
Error, ...
LDA (PAR
%Load register A with address of parameter list.
MON 324
%Monitor call OctobusFunction.
PAR, FUNC
LDN
STAT
FUNC, O
%Function.
LDN, ...
%Logical device number.
STAT, ...
%Status.
ndmonlib implementation¶
Stub Registered MON_STATUS_NOT_IMPLEMENTED: the handler is a stub. mon_dispatch() in src/core/mon_dispatch.c reports the call as unimplemented without calling it.
| Handler | mon_324B_OctobusFunction |
| Code lines | 8 (non-blank, non-comment lines in the file) |
Source¶
SINTRAN III Monitor Calls (ND-860228.2 EN), page 361.