Skip to content

436B SetND500Param

Stub   MON 436B (286 decimal) · Mnemonic 5PASET · Group: Monitor Calls for Error Handling (manual section 2.8)

Available from: All programs (manual compatibility box)

Emulation source: src/handlers/mon_436B_SetND500Param.c

Description

Sets information about an ND-500 program. Use GetND500Param to read the 5 parameters when a program is terminated.

  • SINTRAN III sets some of the parameter values if you give the command @ENABLE-TERMINATION-HANDLING first.

Parameters

Name Type Direction Description
Buffer INTEGER2[5] In 5-word buffer: [0]=user/dir index (bits 24:16=user, 15:0=directory), [1]=terminal device number, [2]=error number or -1 if ESCAPE, [3][4]=user parameters.

Direction: In = the program supplies the value, Out = the call returns it, In/Out = both.

See also

TerminationHandling, GetUserParam, SetUserParam, and GetND500Param

Compatibility

Machines Users Programs
ND-500 All users All programs

The manual's compatibility box for this call, word for word.

Yes/no fields from the YAML extraction (not in the manual's words):

ND-100 ND-500 User programs RT programs System programs
No Yes No No No

Examples

From the manual (OCR text, not corrected).

INTEGER ARRAY : Buffer(0:4)
...
Monitor_Call('SetND500Param', Buffer(0))
INTEGER Buffer(5)
...
Monitor_Call('SetND500Param', Buffer(1))
Buffer : RECORD...END;
...
SetND500Param(Buffer);
01 Buffer.
   02 array COMP OCCURS 5 TIMES.
   ...
   MONITOR-CALL "SetND500Param" USING Buffer.
Buffer : W BLOCK 5
SetND500Param : EQU 37B9 + 436B
...
CALLG SetND500Param, 1, Buffer
This monitor call is not available on the ND-100. See SetUserParam.

ndmonlib implementation

Stub Registered MON_STATUS_NOT_IMPLEMENTED: the handler is a stub. mon_dispatch() in src/core/mon_dispatch.c reports the call as unimplemented without calling it.

Handler mon_436B_SetND500Param
Code lines 6 (non-blank, non-comment lines in the file)

Source

SINTRAN III Monitor Calls (ND-860228.2 EN), page 451.