Skip to content

A2=: - Store Most Significant Part of Double Float Register A2

Overview

Mnemonic: a2=: Function: Store most significant part of double float register A2 Class: MOVE Privilege: user

Format: A2=: <operand>


Description

Stores the most significant 32 bits of the double float register A2 to the specified operand. This instruction is used for integer/float register communication, allowing data transfer between integer and float registers without performing any type conversion.

Operation:

<operand> = A2  (most significant 32 bits of D2)

Key Characteristics:

  • Integer/float register communication (no type conversion)
  • Stores MSW (most significant word) of D2
  • Can transfer float to integer register directly
  • Essential for register save/restore operations
  • 2-4 cycles (fastest with register destination)
  • Sets Z and S flags based on stored value
  • Used for saving float registers before calls
  • No type conversion (bitwise transfer only)
  • Paired with A2:= for save/restore sequences

When a register is specified as an operand, the general integer registers (I1-I4) are used. Thus, this instruction can transfer data between float and integer registers directly.

Note that a float register (A1-A4) is equivalent to the most significant part of a double float register (D1-D4), so A2=: stores the entire float register A2.

Operands: 1 Variants: 1 opcode(s)


Variants

Total variants: 1

Variant Opcode Prefix Register Addressing Modes
1/1 0xFE39 - 2 LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE

Operands

Operand 1 (Destination)

The destination operand where the 32-bit most significant part of A2 will be stored.

Type: Word (32-bit) Access: Write

Supported modes:

  • LOCAL - Local data area access (B.variable)
  • RECORD - Record-relative access (R.field)
  • REGISTER - Integer register (I1-I4)
  • PRE_INDEXED - Indexed addressing with offset
  • ABSOLUTE - Absolute memory address

Note: CONSTANT mode is not allowed for destination operands.


Trap Conditions

  • Addressing traps: Invalid address, descriptor range violation, page fault, protection violation
  • Illegal operand specifier (IOS): Attempting to use constant as destination

Data Status Bits

  • Z (Zero): Set if source register A2 = 0, cleared otherwise
  • S (Sign): Set to sign bit of source register A2 (bit 31)
  • O (Overflow): Unaffected
  • K (Flag): Unaffected
  • C (Carry): Unaffected

Examples

Example 1: Store to local variable

        ; Store A2 to local word variable
        A2=: B.TEMP_VALUE

Example 2: Store to integer register

        ; Transfer A2 to integer register I4 (no conversion)
        A2=: I4

Example 3: Store to array

        ; Store A2 to array element indexed by I2
        A2=: B.RESULTS(I2)

Example 4: Save/restore around subroutine

        ; Save A2 before call
        A2=: B.SAVE_A2
        CALL MODIFY_FLOAT_REGS
        A2:= B.SAVE_A2         ; Restore after call

Performance Notes

  • Typical cycles: 2-4 cycles depending on addressing mode
  • Best case: 2 cycles (register to register)
  • Worst case: 4+ cycles (memory access with page fault)

Reference Manual

Section: §16.9 Title: Integer float register communication


See Also