E3=: - Store Least Significant Part of Double Float Register E3 (D3)¶
Overview¶
Mnemonic: e3=:
Function: Store least significant part of double float register D3 (E3)
Class: MOVE
Privilege: user
Format: E3=: <operand>
Description¶
Stores the least significant 32 bits of the double float register D3 (referred to as E3) to the specified operand. This instruction is used for integer/float register communication, allowing data transfer between integer and float registers without performing any type conversion.
Operation:
<operand> = E3 (least significant 32 bits of D3)
Key Characteristics:
- Integer/float register communication (no type conversion)
- Stores LSW (least significant word) of D3
- Can transfer float to integer register directly
- Essential for decomposing 64-bit double values
- 2-4 cycles (fastest with register destination)
- Sets Z and S flags based on stored value
- Paired with A3=: to extract complete D3 register
- No type conversion (bitwise transfer only)
- Used for double-precision bit extraction
When a register is specified as an operand, the general integer registers (I1-I4) are used. Thus, this instruction can transfer data between float and integer registers directly.
The double float registers D1-D4 are 64-bit registers, composed of a most significant part (A1-A4) and least significant part (E1-E4). This instruction stores only the least significant 32 bits.
Operands: 1 Variants: 1 opcode(s)
Variants¶
Total variants: 1
| Variant | Opcode | Prefix | Register | Addressing Modes |
|---|---|---|---|---|
| 1/1 | 0xFE3E | - | 3 | LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE |
Operands¶
Operand 1 (Destination)¶
The destination operand where the 32-bit least significant part of D3 (E3) will be stored.
Type: Word (32-bit) Access: Write
Supported modes:
- LOCAL - Local data area access (B.variable)
- RECORD - Record-relative access (R.field)
- REGISTER - Integer register (I1-I4)
- PRE_INDEXED - Indexed addressing with offset
- ABSOLUTE - Absolute memory address
Note: CONSTANT mode is not allowed for destination operands.
Trap Conditions¶
- Addressing traps: Invalid address, descriptor range violation, page fault, protection violation
- Illegal operand specifier (IOS): Attempting to use constant as destination
Data Status Bits¶
- Z (Zero): Set if source register E3 = 0, cleared otherwise
- S (Sign): Set to sign bit of source register E3 (bit 31)
- O (Overflow): Unaffected
- K (Flag): Unaffected
- C (Carry): Unaffected
Examples¶
Example 1: Store to local variable¶
% Store E3 to local word
E3=: B.LSW_DATA
Example 2: Store to integer register¶
% Transfer E3 to integer register I2 (no conversion)
E3=: I2
Example 3: Extract double float parts¶
% Split D3 into two separate words
A3=: B.UPPER % Store most significant
E3=: B.LOWER % Store least significant
Example 4: Write to record field¶
% Store E3 to record field
E3=: R.MANTISSA_FIELD
Performance Notes¶
- Typical cycles: 2-4 cycles depending on addressing mode
- Best case: 2 cycles (register to register)
- Worst case: 4+ cycles (memory access with page fault)
Reference Manual¶
Section: §16.9 Title: Integer float register communication