Skip to content

A3=: - Store Most Significant Part of Double Float Register A3

Overview

Mnemonic: a3=: Function: Store most significant part of double float register A3 Class: MOVE Privilege: user

Format: A3=: <operand>


Description

Stores the most significant 32 bits of the double float register A3 to the specified operand. This instruction is used for integer/float register communication, allowing data transfer between integer and float registers without performing any type conversion.

Operation:

<operand> = A3  (most significant 32 bits of D3)

Key Characteristics:

  • Integer/float register communication (no type conversion)
  • Stores MSW (most significant word) of D3
  • Can transfer float to integer register directly
  • Essential for register save/restore operations
  • 2-4 cycles (fastest with register destination)
  • Sets Z and S flags based on stored value
  • Used for saving float registers before calls
  • No type conversion (bitwise transfer only)
  • Paired with A3:= for save/restore sequences

When a register is specified as an operand, the general integer registers (I1-I4) are used. Thus, this instruction can transfer data between float and integer registers directly.

Note that a float register (A1-A4) is equivalent to the most significant part of a double float register (D1-D4), so A3=: stores the entire float register A3.

Operands: 1 Variants: 1 opcode(s)


Variants

Total variants: 1

Variant Opcode Prefix Register Addressing Modes
1/1 0xFE3A - 3 LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE

Operands

Operand 1 (Destination)

The destination operand where the 32-bit most significant part of A3 will be stored.

Type: Word (32-bit) Access: Write

Supported modes:

  • LOCAL - Local data area access (B.variable)
  • RECORD - Record-relative access (R.field)
  • REGISTER - Integer register (I1-I4)
  • PRE_INDEXED - Indexed addressing with offset
  • ABSOLUTE - Absolute memory address

Note: CONSTANT mode is not allowed for destination operands.


Trap Conditions

  • Addressing traps: Invalid address, descriptor range violation, page fault, protection violation
  • Illegal operand specifier (IOS): Attempting to use constant as destination

Data Status Bits

  • Z (Zero): Set if source register A3 = 0, cleared otherwise
  • S (Sign): Set to sign bit of source register A3 (bit 31)
  • O (Overflow): Unaffected
  • K (Flag): Unaffected
  • C (Carry): Unaffected

Examples

Example 1: Store to local variable

        % Store A3 to local word variable
        A3=: B.OUTPUT

Example 2: Store to integer register

        % Transfer A3 to integer register I3 (no conversion)
        A3=: I3

Example 3: Store to array

        % Store A3 to array element
        A3=: B.BUFFER(I1)

Example 4: Preserve register during computation

        % Save A3 during complex calculation
        A3=: B.TEMP_A3
        % ... other float operations ...
        A3:= B.TEMP_A3         % Restore

Performance Notes

  • Typical cycles: 2-4 cycles depending on addressing mode
  • Best case: 2 cycles (register to register)
  • Worst case: 4+ cycles (memory access with page fault)

Reference Manual

Section: §16.9 Title: Integer float register communication


See Also