A4:= - Load Most Significant Part of Double Float Register A4

Overview

Mnemonic: a4:= Function: Load most significant part of double float register A4 Class: MOVE Privilege: user

Format: A4:= <operand>


Description

Loads the most significant 32 bits of the double float register A4 from the specified operand. This instruction is used for integer/float register communication, allowing data transfer between integer and float registers without performing any type conversion.

Operation:

A4 = <operand>  (most significant 32 bits of D4)

Key Characteristics:

  • Integer/float register communication (no type conversion)
  • Loads MSW (most significant word) of D4
  • A4 register equivalent to MSW of D4 (float register)
  • Can transfer integer to float register directly
  • Essential for register restore and bit manipulation
  • 2-4 cycles (fastest with register source)
  • Sets Z and S flags based on loaded value
  • Used for restoring float registers after calls
  • No type conversion (bitwise transfer only)

When a register is specified as an operand, the general integer registers (I1-I4) are used. Thus, this instruction can transfer data between integer and float registers directly.

Note that a float register (A1-A4) is equivalent to the most significant part of a double float register (D1-D4), so A4:= loads the entire float register A4.

Operands: 1 Variants: 1 opcode(s)


Variants

Total variants: 1

Variant Opcode Prefix Register Addressing Modes
1/1 0xFE33 - 4 LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE

Operands

Operand 1 (Source)

The source operand containing the 32-bit word to load into the most significant part of A4.

Type: Word (32-bit) Access: Read

Supported modes:

  • LOCAL - Local data area access (B.variable)
  • RECORD - Record-relative access (R.field)
  • CONSTANT - Immediate constant value
  • REGISTER - Integer register (I1-I4)
  • PRE_INDEXED - Indexed addressing with offset
  • ABSOLUTE - Absolute memory address

Trap Conditions

  • Addressing traps: Invalid address, descriptor range violation, page fault, protection violation

Data Status Bits

  • Z (Zero): Set if source operand = 0, cleared otherwise
  • S (Sign): Set to sign bit of source operand (bit 31)
  • O (Overflow): Unaffected
  • K (Flag): Unaffected
  • C (Carry): Unaffected

Examples

Example 1: Load from local variable

        % Load A4 from local word variable
        A4:= B.MULTIPLIER

Example 2: Load from integer register

        % Transfer I4 to A4 without conversion
        A4:= I4

Example 3: Load from record field

        % Load A4 from record field
        A4:= R.DATA_FIELD

Example 4: Load immediate constant

        % Load A4 with bit pattern
        A4:= 03FF00000H        % Specific float bit pattern

Performance Notes

  • Typical cycles: 2-4 cycles depending on addressing mode
  • Best case: 2 cycles (register to register)
  • Worst case: 4+ cycles (memory access with page fault)

Reference Manual

Section: §16.9 Title: Integer float register communication


See Also