A4:= - Load Most Significant Part of Double Float Register A4¶
Overview¶
Mnemonic: a4:=
Function: Load most significant part of double float register A4
Class: MOVE
Privilege: user
Format: A4:= <operand>
Description¶
Loads the most significant 32 bits of the double float register A4 from the specified operand. This instruction is used for integer/float register communication, allowing data transfer between integer and float registers without performing any type conversion.
Operation:
A4 = <operand> (most significant 32 bits of D4)
Key Characteristics:
- Integer/float register communication (no type conversion)
- Loads MSW (most significant word) of D4
- A4 register equivalent to MSW of D4 (float register)
- Can transfer integer to float register directly
- Essential for register restore and bit manipulation
- 2-4 cycles (fastest with register source)
- Sets Z and S flags based on loaded value
- Used for restoring float registers after calls
- No type conversion (bitwise transfer only)
When a register is specified as an operand, the general integer registers (I1-I4) are used. Thus, this instruction can transfer data between integer and float registers directly.
Note that a float register (A1-A4) is equivalent to the most significant part of a double float register (D1-D4), so A4:= loads the entire float register A4.
Operands: 1 Variants: 1 opcode(s)
Variants¶
Total variants: 1
| Variant | Opcode | Prefix | Register | Addressing Modes |
|---|---|---|---|---|
| 1/1 | 0xFE33 | - | 4 | LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE |
Operands¶
Operand 1 (Source)¶
The source operand containing the 32-bit word to load into the most significant part of A4.
Type: Word (32-bit) Access: Read
Supported modes:
- LOCAL - Local data area access (B.variable)
- RECORD - Record-relative access (R.field)
- CONSTANT - Immediate constant value
- REGISTER - Integer register (I1-I4)
- PRE_INDEXED - Indexed addressing with offset
- ABSOLUTE - Absolute memory address
Trap Conditions¶
- Addressing traps: Invalid address, descriptor range violation, page fault, protection violation
Data Status Bits¶
- Z (Zero): Set if source operand = 0, cleared otherwise
- S (Sign): Set to sign bit of source operand (bit 31)
- O (Overflow): Unaffected
- K (Flag): Unaffected
- C (Carry): Unaffected
Examples¶
Example 1: Load from local variable¶
% Load A4 from local word variable
A4:= B.MULTIPLIER
Example 2: Load from integer register¶
% Transfer I4 to A4 without conversion
A4:= I4
Example 3: Load from record field¶
% Load A4 from record field
A4:= R.DATA_FIELD
Example 4: Load immediate constant¶
% Load A4 with bit pattern
A4:= 03FF00000H % Specific float bit pattern
Performance Notes¶
- Typical cycles: 2-4 cycles depending on addressing mode
- Best case: 2 cycles (register to register)
- Worst case: 4+ cycles (memory access with page fault)
Reference Manual¶
Section: §16.9 Title: Integer float register communication