Skip to content

STZ - Store Zero

Overview

Mnemonic: stz Function: Store zero to operand Class: MOVE Privilege: user Format: t STZ <operand>


Description

Replaces the contents of the destination operand with zero. This instruction provides an efficient way to clear variables, array elements, or registers without requiring a separate zero constant. The zero flag (Z) is always set to 1 after execution.

Operation:

0 → operand
1 → Z flag

Key Characteristics:

  • Efficient zero-store instruction (no constant operand needed)
  • 6 data type variants (BI, BY, H, W, F, D)
  • Z flag always set to 1 after execution
  • Faster than MOVE 0, dest (2-3 cycles vs 3-4)
  • More compact encoding (3 bytes vs 5-7)
  • Essential for initialization and clearing
  • Write-only operation (no source read)
  • Common in loops and state reset
  • Single-element clearing (use BMOVE for bulk)

STZ is commonly used for initialization, clearing accumulators, and resetting state variables. It is more efficient than loading zero into a register and then storing it.

Common Use Cases:

  • Variable initialization
  • Array element clearing
  • Register zeroing
  • State reset operations
  • Clearing flags or status bytes

Operands: 1 (destination, write-only) Variants: 6 opcodes (BI, BY, H, W, F, D)


Variants

Variant Opcode Data Type Assembly Notation
1/6 0xFC85 Bit BI STZ
2/6 0x0048 Byte BY STZ
3/6 0x0049 Halfword H STZ
4/6 0x004A Word W STZ
5/6 0x004B Float F STZ
6/6 0x004C Double D STZ

Operands

Operand 1 (Destination, Write):

  • Addressing modes: LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE
  • Data type: Matches instruction prefix (BI/BY/H/W/F/D)
  • Role: Destination to be cleared to zero
  • Note: CONSTANT addressing mode is not supported (cannot write to constant)

Trap Conditions

  • Addressing traps: Invalid address, page fault, protection violation
  • Write protection: Attempt to write to read-only memory

Data Status Bits

  • Z (Zero): Always set to 1
  • S (Sign): Unaffected
  • C (Carry): Unaffected
  • V (Overflow): Unaffected

Examples

Example 1: Clear byte variable

        % Clear the byte FLAGS
        BY STZ FLAGS

Example 2: Clear word counter

        % Zero a word variable
        W STZ B.COUNT

Example 3: Clear array element

        % Clear array element indexed by W2
        W STZ ARRAY(W2)

Example 4: Reset record field

        % Clear a record field
        W STZ R.VALUE

Example 5: Initialize float to zero

        % Set float variable to 0.0
        F STZ TEMPERATURE

Example 6: Clear local variable

        % Zero a local stack variable at offset 16
        W STZ B.16

Example 7: Clear multiple array elements

        % Clear first 10 elements of array
        W1 CLR
LOOP:
        W STZ BUFFER(W1)
        W1 INC
        W1 COMP 10
        IF<GO LOOP

Performance Notes

  • Execution: 2-3 cycles (faster than MOVE 0, dest)
  • Efficiency: More compact encoding than loading zero constant
  • Memory: Single instruction vs. multi-byte constant load + store
  • Best for: Single-element clearing (use BMOVE for bulk zeroing)

Comparison:

  • W STZ VAR: 3 bytes, 2 cycles
  • W MOVE 0, VAR: 5-7 bytes, 3-4 cycles

Reference Manual

Section: §10.17 Title: Store zero


See Also

  • CLR - Clear register
  • MOVE - General move/store
  • BMOVE - Block move/fill (bulk zeroing)
  • INIT - Initialize operations