E1:= - Load Least Significant Part of Double Float Register E1 (D1)¶
Overview¶
Mnemonic: e1:=
Function: Load least significant part of double float register D1 (E1)
Class: MOVE
Privilege: user
Format: E1:= <operand>
Description¶
Loads the least significant 32 bits of the double float register D1 (referred to as E1) from the specified operand. This instruction is used for integer/float register communication, allowing data transfer between integer and float registers without performing any type conversion.
Operation:
E1 = <operand> (least significant 32 bits of D1)
Key Characteristics:
- Integer/float register communication (no type conversion)
- Loads LSW (least significant word) of D1
- Essential for constructing 64-bit double float values
- Paired with A1:= to build complete D1 register
- Can transfer integer to float register directly
- 2-4 cycles (fastest with register source)
- Sets Z and S flags based on loaded value
- Used for double-precision bit manipulation
- No type conversion (bitwise transfer only)
When a register is specified as an operand, the general integer registers (I1-I4) are used. Thus, this instruction can transfer data between integer and float registers directly.
The double float registers D1-D4 are 64-bit registers, composed of a most significant part (A1-A4) and least significant part (E1-E4). This instruction loads only the least significant 32 bits.
Operands: 1 Variants: 1 opcode(s)
Variants¶
Total variants: 1
| Variant | Opcode | Prefix | Register | Addressing Modes |
|---|---|---|---|---|
| 1/1 | 0xFE34 | - | 1 | LOCAL, RECORD, CONSTANT, REGISTER, PRE_INDEXED, ABSOLUTE |
Operands¶
Operand 1 (Source)¶
The source operand containing the 32-bit word to load into the least significant part of D1 (E1).
Type: Word (32-bit) Access: Read
Supported modes:
- LOCAL - Local data area access (B.variable)
- RECORD - Record-relative access (R.field)
- CONSTANT - Immediate constant value
- REGISTER - Integer register (I1-I4)
- PRE_INDEXED - Indexed addressing with offset
- ABSOLUTE - Absolute memory address
Trap Conditions¶
- Addressing traps: Invalid address, descriptor range violation, page fault, protection violation
Data Status Bits¶
- Z (Zero): Set if source operand = 0, cleared otherwise
- S (Sign): Set to sign bit of source operand (bit 31)
- O (Overflow): Unaffected
- K (Flag): Unaffected
- C (Carry): Unaffected
Examples¶
Example 1: Load from local variable¶
% Load E1 (least significant part of D1) from local word
E1:= B.LSW_VALUE
Example 2: Load from integer register¶
% Transfer I2 to E1 without conversion
E1:= I2
Example 3: Construct double float from two words¶
% Build D1 from two separate words
A1:= B.MSW % Load most significant part
E1:= B.LSW % Load least significant part
Example 4: Load immediate value¶
% Load E1 with specific bit pattern
E1:= 012345678H % Least significant bits of double
Performance Notes¶
- Typical cycles: 2-4 cycles depending on addressing mode
- Best case: 2 cycles (register to register)
- Worst case: 4+ cycles (memory access with page fault)
Reference Manual¶
Section: §16.9 Title: Integer float register communication