Skip to content

E2=: - Store Least Significant Part of Double Float Register E2 (D2)

Overview

Mnemonic: e2=: Function: Store least significant part of double float register D2 (E2) Class: MOVE Privilege: user

Format: E2=: <operand>


Description

Stores the least significant 32 bits of the double float register D2 (referred to as E2) to the specified operand. This instruction is used for integer/float register communication, allowing data transfer between integer and float registers without performing any type conversion.

Operation:

<operand> = E2  (least significant 32 bits of D2)

Key Characteristics:

  • Integer/float register communication (no type conversion)
  • Stores LSW (least significant word) of D2
  • Can transfer float to integer register directly
  • Essential for decomposing 64-bit double values
  • 2-4 cycles (fastest with register destination)
  • Sets Z and S flags based on stored value
  • Paired with A2=: to extract complete D2 register
  • No type conversion (bitwise transfer only)
  • Used for double-precision bit extraction

When a register is specified as an operand, the general integer registers (I1-I4) are used. Thus, this instruction can transfer data between float and integer registers directly.

The double float registers D1-D4 are 64-bit registers, composed of a most significant part (A1-A4) and least significant part (E1-E4). This instruction stores only the least significant 32 bits.

Operands: 1 Variants: 1 opcode(s)


Variants

Total variants: 1

Variant Opcode Prefix Register Addressing Modes
1/1 0xFE3D - 2 LOCAL, RECORD, REGISTER, PRE_INDEXED, ABSOLUTE

Operands

Operand 1 (Destination)

The destination operand where the 32-bit least significant part of D2 (E2) will be stored.

Type: Word (32-bit) Access: Write

Supported modes:

  • LOCAL - Local data area access (B.variable)
  • RECORD - Record-relative access (R.field)
  • REGISTER - Integer register (I1-I4)
  • PRE_INDEXED - Indexed addressing with offset
  • ABSOLUTE - Absolute memory address

Note: CONSTANT mode is not allowed for destination operands.


Trap Conditions

  • Addressing traps: Invalid address, descriptor range violation, page fault, protection violation
  • Illegal operand specifier (IOS): Attempting to use constant as destination

Data Status Bits

  • Z (Zero): Set if source register E2 = 0, cleared otherwise
  • S (Sign): Set to sign bit of source register E2 (bit 31)
  • O (Overflow): Unaffected
  • K (Flag): Unaffected
  • C (Carry): Unaffected

Examples

Example 1: Store to local variable

        % Store E2 to local word
        E2=: B.LSW_OUTPUT

Example 2: Store to integer register

        % Transfer E2 to integer register I4 (no conversion)
        E2=: I4

Example 3: Decompose double float

        % Extract D2 into two 32-bit words
        A2=: B.HIGH_WORD      % Store most significant
        E2=: B.LOW_WORD       % Store least significant

Example 4: Store to array

        % Store E2 to array element
        E2=: B.BUFFER(I2)

Performance Notes

  • Typical cycles: 2-4 cycles depending on addressing mode
  • Best case: 2 cycles (register to register)
  • Worst case: 4+ cycles (memory access with page fault)

Reference Manual

Section: §16.9 Title: Integer float register communication


See Also