Skip to content

Page 1

Norsk Data A.S - Program Description

Date: 88.05.26

Page 1 of 5

Product

Name Reg. no. Category
ND-500/2 Micro Test Programs II 211041B STPR

Reason

| x New product | · Error Correction |

Documentation

Title Reg. no.
Test Microprogram II Description for ND-500/2 30.100.1 EN

Purpose

Improved program user interface with new features like: - All test parameters are automatically found by the program. - User-defined test sequence from file. - Implemented TELEFIX function.

Prerequisites

Computer Type Floating format Op. system Version
ND-500/2 CX VSX/500 J and K

Minimum permanent mass storage resources:

User Userspace Number of files
RT 20 pages on 2 files
N502-TEMICS 610 pages on 26 files

Max/Min number of RT-descriptions: Max 1 Min 1
Max/Min number of segments: Max 1 Min 1
Space requirements on segment file(s) is 64 pages

Reg. no. for Source: 250174B

File Description

File Name Type Containing
SCRIPT-EXAMP-B SYMB Mode command example
INST-TEMICS-B MODE Copies test programs to disk
INST-TPE-DIS-B MODE Loads the TPE monitor from disk
INST-TPE-FLO-B MODE Loads the TPE monitor from floppy
MPEST-B03 BPUN Stand alone memory test program
RELEAS-500-SIN-J MODE Patches resid. on SINTRAN III-J
RELEAS-500-SIN-K MODE Patches resid. on SINTRAN III-K
SIN-PATCH-J-B MODE Sintran patch for SINTRAN III-J
TEMICS-ABBRV-B DATA Abbreviation table 500/2
TEMICS-ARITH-B NEXT Test overlay (NPL/MAC/m)
TEMICS-COMD2-B NEXT Command overlay no.2
TEMICS-COMD3-B NEXT Command overlay no.3
TEMICS-COMTE-B NEXT Test overlay (NPL/MAC/m)
TEMICS-EXTRA-B NEXT Test overlay (NPL/MAC/m)
TEMICS-GMEM2-B NEXT Test overlay (NPL/MAC/m)
TEMICS-GMENT-B NEXT Test overlay (NPL/MAC/m)
TEMICS-GMOFF-B NEXT Test overlay (NPL/MAC/m)
TEMICS-MEMIC-B NEXT Test overlay (NPL/MAC/m)
TEMICS-NDS50-B NEXT Main command overlay
TEMICS-PREE-B NEXT Test overlay (NPL/MAC/m)
TEMICS-PREEF-B NEXT Test overlay (NPL/MAC/m)
TEMICS-SLIC2-B NEXT Test overlay (NPL/MAC/m)
TEMICS-SLICE-B NEXT Test overlay (NPL/MAC/m)
TEMICS-TRAPT-B NEXT Test overlay (NPL/MAC/m)
TPE-MON-100 BPUN Test Program Monitor for ND-100
CS-ZERO-5000 DATA For filling CS with "0" bits
TPE-RT-MON PROG Start-up program for TPEMON

Page 2

PROGRAM DESCRIPTION

Date Norsk Data A.S Page 2 of 5
Product Name Reg. no.
ND-500/2 Micro Test Programs II 211041B STPR

NOTE: <rev> is to be replaced by the current revision of the DIRECTORY or FILE. The revision level is found on the preceding "ND SOFTWARE LIBRARY DISKETTE" pages.

1 THE PRODUCT

  • The ND-500/2 Micro Test Programs II, TEMICS, is a total revision of the old ND-500/2 Micro Test Programs (210521B03). 211041B00 will be a direct replacement for 210521B03, but 210521B03 is possible to use as a stand-alone program. On the other hand, 211041B has many new facilities which the version 210521B03 did not have. (See the "Test Microprogram II Description for ND-500/2 (Reg.no. 30.100.1 EN) ).

2 ERRORS CORRECTED

  • All the subtests are updated according to new micro cycle timing definition. See the command >NEWS in the program.
  • In the old Micro Test Programs (210521B03) the ND-500/2 was not reserved for special use when no memory was reserved. This is corrected in TEMICS.

3 KNOWN, BUT NOT CORRECTED ERRORS

  • TEMICS is running as a RT-program called TPEMON. The product TPE-MONITOR version A02 (as TEMICS is loaded under) contains an error seen when running the command >MODE with outputfile=TERMINAL. This causes stack overflow on the TPE-MONITOR. If using ‘output filename’ as a user file, no problems have been seen.

4 CHANGED PREREQUISITES

  • The ND-500/2 Micro Test Programs II - Version B00 is loaded under the TPE Monitor version A02 for ND-100/ND-110 and this monitor must be started first before testing the ND-500/2 system. (See chapter STARTING UP THE ND-502 MICRO TEST PROGRAMS.)
   ooo   ND Norsk Data   ooo

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 3

Norsk Data A.S Program Description

Date Page Reg. no. Category
88.05.26 3 of 5 211041B STPR

Product

Name
ND-500/2 Micro Test Programs II

5 Modifications

5.1 New Commands

  • All commands are new. (See the "Test Microprogram II Description for ND-500/2 (Reg.no. 30.100.1 EN)").

5.2 Modified Subtests

  • Nearly all subtests are updated with new microcycle timing. Other functions are modified in the following subtests:
    • Subtest 806 in EXTRA.

(For details refer to the "Test Microprogram II Description for ND-500/2").

6 Installation Procedure

This installation procedure makes it possible to install and start the ND-500/2 Micro Test Programs:

A) Make sure you are running SINTRAN III - VSX/500 on a ND-500/2 machine.

B) Log in as user RT. Check that user RT has a minimum of 20 free pages:

@USER-STATISTICS RT,←

C) Enter the directory 211041B-XX-01D in floppy-unit 0. The user FLOPPY-USER contains all files:

@ENTER-DIRECTORY-
DIRECTORY NAME: 211041B<rev>-XX-01D-
DEVICE NAME: FLOPPY-DISC-<drive-no.>,<floppy-unit>-

D) Run the mode file:

@MODE (211041B:FLOPPY-USER)INST-TPE-FLO-B:MODE,←

(This installs the TPE-MONITOR on a segment and copies the TPE-MONITOR start-up program TPE-RT-MONIT-B:PROG to user RT).

E) Log in as user SYSTEM

F)

@DELETE-FILE SIN-PATCH-J:OUT←

(if such a file exists).

ooo ND Norsk Data ooo

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 4

Program Description

Date: 88.05.26
Company: Norsk Data A.S
Page: 4 of 5

Product Name Reg. no. Category
ND-500/2 Micro Test Programs II 211041B STPR

Instructions

G)

@LIST-TITLE- (to get the SINTRAN revision number in octal).

H)

If you have a SINTRAN III VSX/500 J-VERSION with revision/patch earlier than 11000B, patch SINTRAN III by running the mode job:
@MODE-
INPUT FILE: (211041B:FLOPPY-USER)SIN-PATCH-J:MODE-
OUTPUT FILE: "SIN-PATCH-J:OUT"-

I)

Inspect the file SIN-PATCH-J:OUT to verify that there are no errors.
@PED SIN-PATCH-J:OUT-
or
@COPY TERMINAL,SIN-PATCH-J:OUT-.

If the MODE job stops here, qualified personnel must be contacted.

J)

Now you must decide whether you want to load and start the tests from the DISC drive or the FLOPPY drive!

NOTE:
If you want to load and start the tests from the FLOPPY drive you should now proceed at once to the chapter STARTING UP THE ND-5002 MICRO TEST PROGRAMS.

The following steps make it possible to load and start the tests from the DISC drive:

K)

Log in as user SYSTEM

L)

Create the user N502-TEMICS with minimum 610 pages:
@CREATE-USER N502-TEMICS-
@GIVE-USER-SPACE N502-TEMICS 610-.

M)

Log in as user N502-TEMICS.

N)

Install the TEMICs by running the mode file:
@MODE (211041B:FLOPPY-USER)INST-TEMICS-B:MODE,,,-

This file copies all the test program files into the user N502-TEMICS on the disk.

O)

Release the directory 211041B-XX-01D

7 Starting Up the ND-502 Micro Test Programs

A)

Log in as user RT.

   ooo  ND Norsk Data  ooo

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 5

Program Description

Date Norsk Data A.S Page 5 of 5
Product Name Reg. no.
ND-500/2 Micro Test Programs II 211041B

Instructions

B) Start the Test Program Environment Monitor for ND-100 or ND-110 by starting the program TPE-RT-MON:PROG :

@TPE-RT-MON:PROG,,,

C) Start TEMICS by using the following commands:

a) from disk:

TPE>LOAD-PROGRAM (N502-TEMICS)TEMICS-

or just

TPE>(N502-TEMICS)TEMICS-

b) from diskette:

TPE>LOAD-PROGRAM (211041B;FLOPPY-USER)TEMICS-

or just

TPE>(211041B:FLOPPY-USER)TEMICS-

Now you should be able to type any command taken from the TPE>HELP list. (To get the test parameters automatically, the test investigation is started by the TPE)>INVESTIGATE-AND-RESERVE command or if low system level: TPE)>SET-PARAMETER. For details, refer to the "Test Microprogram II Description for ND-500/2."

(Remember to release the directory 211041B-XX-01D after testing if you are running the tests from the floppy).

NOTE:

  • After warm-start of SINTRAN: No special actions required.
  • After cold-start of SINTRAN: The RT-program TPEMON will disappear, but by logging in as user RT and running the file:
(211041B<rev>-XX-01D:FLOPPY-USER)INST-TPE-FLO-B:MODE

or the file

(N502-TEMICS)INST-TPE-DIS-B:MODE

you will reload this RT-PROGRAM.


Page 6

ND Software Library Diskette

Directory Information

  • Containing: ND-500/2 Micro Test Programs II
  • Directory Name: 211041B03-XX-01D

User Name: FLOPPY-USER

No File Name Type T Public Friend Own Pages Bytes
0 TPE-MON-100 BPUN I RWACD RWACD RWACD 29 56182
1 TPE-RT-MON PROG I RWACD RWACD RWACD 6 9216
2 TEMICS-ND500-B02 TEST I RWACD RWACD RWACD 53 106496
3 TEMICS-COMD2-B02 NEXT I RWACD RWACD RWACD 25 47616
4 TEMICS-COMD3-B02 NEXT I RWACD RWACD RWACD 25 47616
5 TEMICS-COMTE-B02 NEXT I RWACD RWACD RWACD 27 265216
6 TEMICS-SLICE-B02 NEXT I RWACD RWACD RWACD 27 264704
7 TEMICS-SLIC2-B02 NEXT I RWACD RWACD RWACD 27 265728
8 TEMICS-SLIC3-B02 NEXT I RWACD RWACD RWACD 25 47616
9 TEMICS-MEMIC-B02 NEXT I RWACD RWACD RWACD 29 270336
10 TEMICS-PREEF-B02 NEXT I RWACD RWACD RWACD 27 265216
11 TEMICS-PREEZ-B02 NEXT I RWACD RWACD RWACD 26 264192
12 TEMICS-ARITH-B02 NEXT I RWACD RWACD RWACD 27 265728
13 TEMICS-GOFF-B02 NEXT I RWACD RWACD RWACD 26 264192
14 TEMICS-GMENT-B02 NEXT I RWACD RWACD RWACD 27 265728
15 TEMICS-GMEN2-B02 NEXT I RWACD RWACD RWACD 26 264192
16 TEMICS-TRAPT-B02 NEXT I RWACD RWACD RWACD 27 265728
17 TEMICS-EXTRA-B02 NEXT I RWACD RWACD RWACD 27 264704
18 TEMICS-ADDIT-B02 NEXT I RWACD RWACD RWACD 27 264704
19 TEMICS-ABBRV-B02 DATA I RWACD RWACD RWACD 44 60241
20 MPEST-B02 BPUN I RWACD RWACD RWACD 13 22870
21 INST-TPE-FLO-B MODE I RWACD RWACD RWACD 3 2253
22 INST-TPE-DIS-B MODE I RWACD RWACD RWACD 3 2310
23 INST-TEMICS-B MODE I RWACD RWACD RWACD 4 4989
24 SIN-PATCH-J-A MODE I RWACD RWACD RWACD 3 2544
25 TEM-PD-SHEET-B02 TEXT I RWACD RWACD RWACD 14 20776
26 RELEAS-500-SIN-J MODE I RWACD RWACD RWACD 2 708
27 RELEAS-500-SIN-K MODE I RWACD RWACD RWACD 2 710
28 MODE-EX-B SYMB I RWACD RWACD RWACD 3 2466
29 DUMPTRACE SYMB RWACD RWACD RWACD 0 0

Note: 30 files using 604 pages. 610 pages reserved out of 610 pages.