Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| Upgrade for Basic SYSTEM Software for Small Systems | 380739A |
Norsk Data¶
Description of product¶
This product contains corrections to the product "Basic SYSTEM Software for Small Systems" - ND-211470B01
Reason(s) for new product or version¶
+--------------------------------------------------------------------------+
| This product was created to simplify the correction of errors on |
| Basic SYSTEM Software for Small Systems ND-no. 211470B01. |
+--------------------------------------------------------------------------+
Table of Contents¶
| Description | Page |
|---|---|
| Prerequisites | 2 |
| Dependencies | 3 |
| Documentation | 3 |
| Installation procedure | 4 |
| Errors corrected | 4 |
| Errors known but not corrected | 4 |
| Modifications | 6 |
ND-895524.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 2¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.01.15 | 2 of 6 |
| Product name | Product number |
|---|---|
| Upgrade for Basic SYSTEM Software for Small Systems | 380739A |
1 Prerequisites¶
The following things are required in order to use this product.
1.1 Hardware prerequisites¶
The following hardware must be present for this product to be used:
CPU type (any of the following):
- 5000
Floating format on the 100/110/120 CPU: 32 bit.
Other hardware:
- A system disk of 310MB SCSI.
1.2 Software prerequisites¶
The following software must be installed on the system for this product to be used:
Operating system:
| Name | Version/Revision |
|---|---|
| None |
Other software:
| Product name | Product number |
|---|---|
| Basic SYSTEM Software for Small Systems | 211470B01 |
1.3 Other prerequisites¶
The following is necessary for this product to be used.
Minimum Permanent Mass Storage:
See PI-sheet for 211470B01.
ND-895524.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 3¶
Product Information¶
| Date | Page |
|---|---|
| 90.01.15 | 3 of 6 |
| Product name | Product number |
|---|---|
| Upgrade for Basic SYSTEM Software | 380739A |
| for Small Systems |
2 Dependencies¶
In addition to the above listed hardware and/or software prerequisites, the following dependencies exist between this and other products. The hardware and software listed here may, for example, be necessary to use the product's full functionality.
2.1 Hardware dependencies¶
None
2.2 Software dependencies¶
There are dependency relationships between this product and the following software:
The necessary software key for the activated modules must be installed on the system before configuration.
Nature of dependency
If the softkey is NOT installed, installation of some products is not possible.
2.3 Other dependencies¶
In addition to the hardware and software dependency relationships listed above, you should be aware of the following dependencies:
| Product name | Product number |
|---|---|
| None |
3 Documentation¶
Included (distributed free with product)
| Module | Title |
|---|---|
| None |
Optional (must be purchased)
| Module | Title | Number |
|---|---|---|
| None |
ND-895524.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 4¶
Product Information¶
| Date | 90.01.15 |
| Norsk Data | Page 4 of 6 |
| Product name | Upgrade for Basic SYSTEM Software for Small Systems |
| Product number | 380739A |
4 Installation procedure¶
4.1 Automatic installation¶
The installation should be done before running the program:
@(EXTRA-SYSTEM)SYSTEM-CONFIG
Insert the floppy 380739A<rev>-XX-01D in floppy unit 0, enter the directory 380739A00-XX-01D and run the mode file PAT-211470B01:MODE
The missing UE-ERMG-XX-Cyy:ERR where yy is equal or newer than 13, is in the case of the languages ENGLISH, GERMAN and NORWEGIAN included.
For other language options THIS HAS TO BE INSTALLED EXTRA.
4.2 Non-automatic installation¶
None
5 Error Correction¶
5.1 Errors known but not corrected¶
The following are known but not corrected errors on streamer 211470B01.
The errors should be corrected before running the program:
@(EXTRA-SYSTEM)SYSTEM-CONFIG
as described in the installation procedure.
A) Some mode files on user MODE-FILES are incorrect.
Solution:
Use BACKUP-SYSTEM and copy all files from LANGUAGE:SAVE-MODE to PACK-BASIC:MODE-FILES before configuring the system.
ND-895524.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 5¶
Product Information¶
| Product name | Product number |
|---|---|
| Upgrade for Basic SYSTEM Software for Small Systems | 380739A |
B) ND-LINKER Issue¶
The name of the new domain format linker is ND-LINKER. This gives problems in some mode files calling the ND-500-MONITOR using the shortened call @ND only.
Solution:
Edit the file (MODE-FILES)ND-500-HENT:MODE using PED. Substitute ND-LINKER with LINKER.
C) File Access Problem¶
File access on the file (SYSTEM)ORIGINAL-SYSTEM:LIST is wrong.
Solution: Use the command:
@SET-FILE-ACCESS ORIGINAL-SYSTEM:LIST,,r,rwaod
D) Backup-Manager Unknown Server/System Issue¶
Backup-Manager has problems (unknown server or system) after running @(EXTRA-SYSTEM)STOP-MODE::MODE.
Solution: The reason is that UE is enabled also on the console, and UE-files are open after stopping the UE-server. The user (as always on other terminals after stopping the UE-server) has to log out and then log in again before using the Backup-Manager. Eventually, UE can permanently be disabled on the console.
E) Backup-Manager Error Message Issue¶
Backup-Manager gives the wrong error message texts if using the NON-English version.
Solution:
Install UE-ERMSG-<rev>-C13:err (or NEWER c-version) where <rev> is the relevant language version.
ND-895524.1 EN
Page 6¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.01.15 | 6 of 6 |
| Product name | Product number |
|---|---|
| Upgrade for Basic SYSTEM Software for Small Systems | 380739A |
5 Modifications¶
5.1 New functions/commands¶
None
5.2 Changed functions/commands¶
None
5.3 Removed functions/commands¶
None
5.4 Other modifications¶
None
6 Errors corrected¶
None
7 Errors known but not corrected¶
None
ND-895524.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011