Product Information

Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D

Description of product

To allow use of TCP/IP protocols by applications (FTP, TELNET) in a SINTRAN environment on an Ethernet local area network.

The Telnet server in COSMOS TCP/IP Gateway for Ethernet is compatible with Telnet in Berkeley Unix 4.3. It is not compatible with Telnet in Berkeley Unix 4.2.

Responds to NetMap requests from a Network Control Server (NCS).

Reason(s) for new product or version

Version D02

  • The TCP/IP did not use to checksum the incoming segments/fragments.
  • Known errors has been corrected.

Table of Contents

Section Page
Prerequisites 2
Dependencies 3
Documentation 4
Installation procedure 5
Modifications 7
Errors corrected 8

Page 2

Product Information

Date Norsk Data Page 2 of 8
Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D

1 Prerequisites

The following things are required in order to use this product.

1.1 Hardware prerequisites

The following hardware must be present for this product to be used:

CPU type (any of the following):

  • 100 CX
  • 110 CX
  • 120 CX
  • 500
  • 5000

Floating format: Any

Other hardware:

Product name Product number
Ethernet II controller ND 110063

1.2 Software prerequisites

The following software must be installed on the system for this product to be used:

Operating system:

Name Version/Revision
SINTRAN III L06 PatchFile >= 2000B

Other software:

Product name Product number
BACKUP-SYSTEM version >=H ND-210337
USER ENVIRONMENT version >= D03 ND-210518

ND-895070.2 EN

Scanned by Jonny Oddene for Sintran Data © 2020


Page 3

Product Information

Date Norsk Data Page 3 of 8
Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D

1.3 Other prerequisites

The following are necessary for this product to be used.

Minimum Permanent Mass Storage:

User Space (pages) Number of files
SYSTEM 200 4
TCP-IP 650 16

Minimum Number of segments (ND-100): 3+4*NbOfControllers.
Number of RT descriptions: 3

Space required on segment files: 120+256*NbOfControllers pages

Requirements regarding internal devices:

None

Requirements regarding batch processors:

None

2 Dependencies

In addition to the above listed hardware and/or software prerequisites, the following dependencies exist between this and other products. The hardware and software listed here may, for example, be necessary to use the product's full functionality.

2.1 Hardware dependencies

There are dependency relationships between this product and the following hardware:

None

ND-895070.2 EN


Page 4

Product Information

Date Norsk Data Page
92.01.23 4 of 8
Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D

2.2 Software Dependencies

There are dependency relationships between this product and the following software:

Product name Product number
OWS Access Server for ND-500/5000 211325

Nature of dependency

The installation of the OWS Access Server for the ND-100 depends on this product to be installed.

2.3 Other Dependencies

In addition to the hardware and software dependency relationships listed above, you should be aware of the following dependencies:

None.

3 Documentation

Included (distributed free with product)

Title Number
OpenLAN Network Supervisor Guide 830107.03 EN

Optional (must be purchased)

Title Number
COSMOS TELNET/FTP User Guide 860284.02 EN

ND-895070.2 EN

[Scanned by Jonny Oddene for Sintran Data © 2020]


Page 5

Product Information

Date Norsk Data Page
92.01.23 5 of 8
Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D

4 Installation Procedure

4.1 Selecting Internet Address

  • On request from the installation program, you will have to assign an Internet address for each controller. If your network is isolated from other nets outside your company, you may select the address freely, i.e., using the default values given by the installation program. If your network connects to other networks, free selection of addresses may accidentally give the same address to two installations, which will create severe problems. Selecting proper Internet addresses are further described in the OpenLAN Network Supervisor guide. However, the address for application of an official Internet address range is:

    DDN Network Information Center
    SRI International
    Room EJ217
    333 Ravenswood Avenue
    Menlo Park, CA 94025
    

4.2 Automatic Installation

  • Log in as user SYSTEM
  • Make sure to stop the TCP-IP before starting installation.
  • Insert the floppy 211185D-XX-01D in the floppy drive:
    @ENTER-DIRECTORY,211185,,,
    
  • Run the installation program:
    @(211185:FLOPPY-USER)IN-TCP-IP
    

4.3 Non-Automatic Installation

When the installation program has been run:

  • Update the AIP-HOSTS:SYMB file with the local internet address of the host name. See the documentation for more information.
  • Update the mode file that is run after a cold start (usually called HENT-MODE:MODE) by including the following line:
    @MODE (TCP-IP)TCP-IP-LOAD:MODE,,,
    
    If you had a previous version of this product, remove the line loading the product.

ND-895070.2 EN


Page 6

Product Information

Date Norsk Data Page
92.01.23 6 of 8
Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D
  • Update the mode file that is run after a warm-start (usually called LOAD-MODE:MODE) by including the following line:

    @MODE (TCP-IP)TCP-START:MODE,,,
    

    after XMSG and TADADM has started.

  • Update the mode file that is run before stopping the machine (usually called STOP-MACHINE:MODE), by including the line:

    @MODE (TCP-IP)TCP-STOP:MODE,,
    
  • OWS Access Server If you have installed the OWS Access Server for ND100 (ND211297A07), include the line:

    @O(OpenLAN)OWSAS-SERV START,,,
    

    in the LOAD-MODE:MODE file after the @START-SERVERS command, and

    @O(OpenLAN)OWSAS-SERV STOP 0,,
    

    in the @STOP-MACHINE:MODE file before @MODE (TCP-IP)TCP-STOP:MODE.

  • Powerfail Handling
    The powerfail handler, POPWR, is an RT program that logs in on a Terminal Access Device on the local computer. POPWR will execute any mode file that does not stop TADS or XMSG. The hardcoded input and output file names are:

    (SYSTEM)PO-PWRFAIL:MODE and (SYSTEM)PO-PWRFAIL:OUTP
    

    To enable the program to be started at powerfail one must enter SINTRAN-SERVICE-PROGRAM and type:

    DEFINE-USER-RESTART-PROGRAM POPWR or
    NEXT-USER-RESTART-PROGRAM POPWR   if the command
    LIST-USER-RESTART-PROGRAM  gives any rt program 
                                 name as output.
    

    Execution of the (TCP-IP)TCP-START:MODE file and any other mode files for devices that do not handle powerfail is then included in the PO-PWRFAIL:MODE file.

    After the command @MODE (TCP-IP)TCP-IP-LOAD:MODE,, in the :HENT-MODE file, the SINTRAN-SERVICE command:

    @SINTRAN-SERVICE
    @DEFINE-USER-RESTART-PROGRAM POPWR YES YES YES or
    @NEXT-USER-RESTART-PROGRAM POPWR YES YES YES must be
    included.
    

    Then the files PO-PWRFAIL:MODE and PO-PWRFAIL:OUTP must be created. User RT must have read and write access to these two files. Include in the PO-PWRFAIL:MODE file: @MODE (TCP-IP)TCP-START-D:MODE,,,

    and the TCP/IP will be restarted after a powerfail.

    The PIOC-MONITOR included on diskette 2 is meant for use by ND service personnel only.

ND-895070.2 EN


Page 7

Product Information

Date Norsk Data Page
92.01.23 7 of 8
Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D

5 Modifications

  • The FTP Server may now be started on any Ethernet-II TCP-device, the first by default (i.e. Tcp-device number 0). Edit (TCP-IP)TCP-IP-LOAD-D:MODE if you want to use another controller (see @look-at segment TF?S).

Page 8

Product Information

Date Norsk Data Page
'92.01.23 Page 8 of 8
Product name Product number
COSMOS TCP/IP Gateway for Ethernet 211185D

Errors Corrected

  • In previous versions of this product, the Telnet server would sometimes continue to poll connections that was disconnecting, resulting in excessive error reports. ("Illegal socket ID")
  • Previous versions of this product did not handle UDP-broadcasts correctly, especially incoming UDP-broadcasts were thrown away.
  • Previous versions of this product did not keep complete ARP-entries for more than 3 minutes, these will now be kept for at least half an hour.
  • Previous versions of this product did not always release the internal MBUFs used by the RAW protocol, when they were no longer needed. Likewise, the xmsg-resources used by the controller when an application used SLlib to send data with the RAW protocol, did not get released when finished.
  • In previous versions of this product, datagrams sent to local UDP-port number X would end up at local TCP-port number X if this did exist and had been created before the equally numbered UDP-port.
  • If a TCP/IP controller has been terminated due to an error, (for instance an HW error), a restart of TCP/IP may lead to a SINTRAN stop on level 14 with pagefault from level 2. The problem is corrected by a patch in SINTRAN.

ND-895070.2 EN