Page 1¶
Product Information¶
| Product name | Product number |
| TCP/IP Basic Module/III | 211327B |
Description of Product¶
To allow use of TCP/IP protocols by applications (FTP, TELNET) in a SINTRAN environment on a Ethernet local area network.
Reason(s) for New Product or Version¶
Revision B05¶
- This product allows 124 simultaneous Telnet connections and 8 simultaneous FTP connections.
- SIBAS backend is now available over the TCP/IP Basic Module.
- NFS support may be selected when installing this product.
Table of Contents¶
| Section | Page |
|---|---|
| Prerequisites | 2 |
| Dependencies | 4 |
| Documentation | 5 |
| Maintenance software | 5 |
| Installation procedure | 6 |
| Modifications | 8 |
| Errors corrected | 9 |
| Errors known but not corrected | 9 |
ND-895061.1A EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 2¶
Product Information¶
| Date | Norsk Data | Page 2 of 9 |
|---|---|---|
| Product name | Product number | |
| TCP/IP Basic Module/III | 211327B |
1 Prerequisites¶
The following things are required in order to use this product.
1.1 Hardware Prerequisites¶
The following hardware must be present for this product to be used:
CPU type (any of the following):
- 5000
Floating format: Any
Other hardware:
| Product name | Product number |
|---|---|
| Ethernet III controller | ND 110513 |
1.2 Software Prerequisites¶
The following software must be installed on the system for this product to be used:
Operating system:
| Name | Version/Revision |
|---|---|
| SINTRAN-III/VSX WM07 | L07 |
| Standard Configuration A or B | |
| SINTRAN-VSX Patch file | L04 |
| Patch Level 4300 | |
| ND-5200 microprogram | D01 |
| or ND-5400 microprogram | D01 |
| or ND-5500 microprogram | D01 |
| or ND-5700 microprogram | D01 |
| or ND-5800 microprogram | D01 |
ND-895061.1A EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 3¶
Product Information¶
Date: 90.03.29
Norsk Data
Page 3 of 9
Product Name¶
TCP/IP Basic Module/III
Product Number¶
211327B
Other Software:¶
| Product Name | Product Number |
|---|---|
| BACKUP-SYSTEM version >=I | 210337 |
1.3 Other Prerequisites¶
The following are necessary for this product to be used.
Minimum Permanent Mass Storage:¶
| User | Space (pages) | Number of Files |
|---|---|---|
| SYSTEM | 220 | 5 |
| TCP-IP | 234 | 13 |
| UTILITY | 188 | 1 |
Requirements¶
- Number of segments (ND-100): Minimum 2
- Number of RT descriptions: 2
- Space required on segment files: 72 pages
Requirements regarding MTAD resources per controller (one for each new connection used):¶
- Max number of MTAD datafields: 124
- Number of background programs: 124
Requirements regarding Nucleus resources for the first controller:¶
- Message buffer space for system processes in pages: 16
- Number of descriptors for all system processes: 32
Requirements regarding nucleus resources for each new controller:¶
- Message buffer space for system processes in pages: 1
- Number of descriptors for all system processes: 1
The max number of MTAD datafields (MTMAX) is changed with the SINTRAN-SERVICE-PROGRAM, the number of background programs and nucleus resources with the S3-CONFIG program.
ND-895061.1A EN
Page 4¶
Product Information¶
| Date | Norsk Data | Page 4 of 9 |
|---|---|---|
Product name¶
TCP/IP Basic Module/III
Product number¶
211327B
2 Dependencies¶
In addition to the above listed hardware and/or software prerequisites, the following dependencies exist between this and other products. The hardware and software listed here may, for example, be necessary to use the product's full functionality.
2.1 Hardware Dependencies¶
There are dependency relationships between this product and the following hardware:
None
2.2 Software Dependencies¶
There are dependency relationships between this product and the following software:
| Product name | Product number |
|---|---|
| OWS Access Server for ND-5000 | ND-211325 |
Nature of dependency
The installation of the OWS Access Server for ND-5000 depends on this product to be installed.
| Product name | Product number |
|---|---|
| SIBAS/R Backend for ND-5000 | ND-211404 |
Nature of dependency
This product must be installed if SIBAS Backend shall be used with TCP/IP communication.
2.3 Other Dependencies¶
In addition to the hardware and software dependency relationships listed above, you should be aware of the following dependencies:
None.
ND-895061.1A EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 5¶
Product Information¶
| Date | Norsk Data | Page 5 of 9 |
|---|---|---|
| Product Name | Product Number | |
| TCP/IP Basic Module/III | 211327B |
3 Documentation¶
Included (distributed free with product)
| Title | Number |
|---|---|
| OpenLAN Network Supervisor Guide | 830107.03 EN |
Optional (must be purchased)
| Title | Number |
|---|---|
| COSMOS TELNET/FTP User Guide | 860284.01 EN |
4 Maintenance Software¶
Included in the TCP/IP Basic Module/III is the TCPIP-MONITOR, the Nucleus and Domino maintenance kits. They are intended for use by ND technical support. The TCPIP-MONITOR is delivered as diskette no. 3 of the TCP/IP product, the others are independent products.
| Product Name | Product Number |
|---|---|
| Nucleus Maintenance Kit version C | ND-211321 |
| Domino Maintenance Kit version C | ND-211322 |
ND-895061.1A EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 6¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.03.29 | 6 of 9 |
| Product name | Product number |
|---|---|
| TCP/IP Basic Module/III | 211327B |
5 Installation Procedure¶
5.1 Selecting Internet Address¶
-
On request from the installation program you will have to assign an Internet address for each controller. If your net is isolated from other nets outside your company, you may select the address freely, i.e. using the default values given by the installation program. If your net connects to other nets, free selection of addresses may accidentally give the same address to two installations which will create severe problems. Selecting proper Internet addresses are further described in the OpenLAN Network Supervisor guide. However, the address for application of an official Internet address range is:
DDN Network Information Center SRI International Room EJ217 333 Ravenswood Avenue Menlo Park, CA 94025
5.2 Automatic Installation¶
-
Check that the RT-program PROMAN is running by giving the command:
@LIST-RT-DESCRIPTION PROMANIf the program is not running, the first line will be:
PASSIVE ..... ..... ..... ...... ..... ..... ....Start PROMAN by giving the command
@START-SERVERS. If PROMAN starts without giving any error messages, the installation can continue.If PROMAN fails to start, the command
@START-SERVERSshould be given in the LOAD-MODE:MODE or LOAD-SYSTEM:BATC as described in chapter 5.3, and the system restarted before installation is continued.The installation will fail if PROMAN is passive.
ND-895061.1A EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 7¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.03.29 | 7 of 9 |
| Product name | Product number |
|---|---|
| TCP/IP Basic Module/III | 211327B |
- Insert the floppy 211327B-XX-1D in the floppy-drive
@ENTER-DIRECTORY.211327B,F-D-1,(0,1)
- Log in as user SYSTEM
- Run the installation program:
@(211327:FLOPPY-USER)IN-TCP-BA
- The third floppy, 211327B-XX-03D contains Maintenance programs and is not required for normal use of the TCP/IP Basic Module.
5.3 Completing the Installation¶
When the installation program has been run:
- Update the AIP-HOSTS:SYMB file with the local internet address of the host name. See the documentation for more information.
-
Update the mode file that is run after a cold start (usually called HENT-MODE:MODE) by including the following line:
@MODE (TCP-IP)TCP-BA-LOAD:MODE,,,If you had a previous version of this product, remove the old line loading that version.
-
Insert the line:
@START-SERVERSif you have not already done it, in the LOAD-MODE:MODE or LOAD-SYSTEM:BATC file after starting the XMSG (and after the command
@START-TADADMwhich usually lies in the XMSG startup file) and before starting the ND-5000. Be aware that some systems might have started the ND-5000 in the HENT-MODE:MODE job. In this case you should not start the ND-5000 in the HENT-MODE:MODE, but in the LOAD-MODE:MODE as mentioned above.
- To reboot the domino controller(s), run the mode job:
@MODE (TCP-IP)TCP-BA-REBO:M,,,
- To stop the domino controller(s), run the mode job:
@MODE (TCP-IP)TCP-BA-STOP:M,,,
ND-895061.1A EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 8¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.03.29 | 8 of 9 |
| Product name | Product number |
|---|---|
| TCP/IP Basic Module/III | 211327B |
6 Modifications¶
6.1 New Functions/Commands¶
- Possibility of running TCP/IP in several Ethernet III controllers simultaneously.
- An error message will be issued when another host has the same Internet address.
- This product will now support startup and error reporting to a NCS network server. The Internet address of the NCS server must be put into the AIP-HOSTS:SYMB file with the name AUDITSERVER to achieve this. The product will also answer alive check polling from the NCS server.
6.2 Changed Functions/Commands¶
None.
6.3 Removed Functions/Commands¶
None.
6.4 Other Modifications¶
- The installation program will ask you whether or not you require NFS support. You should answer NO to this unless you are installing NFS at the same time, or else some TCP/IP resources will be wasted.
- The installation program will prompt for the number of Telnet server connections actually bought. You MUST give the correct number, as found in the accompanying ND Licence Agreement document.
- If you are re-installing this product you have to do a warm start afterwards to make the re-installed product function properly with respect to any changes to its configuration. For example, in terms of number of Telnet server connections.
ND-895061.1A EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 9¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.03.29 | 9 of 9 |
| Product name | Product number |
|---|---|
| TCP/IP Basic Module/III | 211327B |
7 Errors Corrected¶
- The Telnet Server will now close a connection if it times out.
- A Telnet connection doing XOFF will not cause the connection to be closed.
- A Telnet connection will run more smoothly due to enhancements regarding queue handling and event handling in the TCP and the Telnet server.
- On power fail the TCP Control server in ND-100 will not close down the controller.
- The stability of the TCP/IP is improved: it will not go down due to long Ethernet packets on the net and it will not accidentally close its own port due to returned messages from applications.
- Dead connections will now be removed by a timer in the TCP.
- Earlier versions sometimes closed connection after 10 minutes without traffic. This was caused by an error in the No Activity Timer. This has been corrected in this version.
- In earlier versions, the FTP server was not capable of handling files larger than 16 MB. The maximum file size is now increased to 128 MB.
- When doing serial file transfer using the OWS Terminal Line Server over a Telnet connection, older versions would sometimes fail when transferring files to the server. This has now been corrected.
- When using SIBAS Backend over TCP/IP, Sibas connections would sometimes be closed down with an error message from the routine HandleSibdata. The error occurred now and then when using the call STOWD (Storing of wide columns).
8 Errors Known But Not Corrected¶
None.
ND-895061.1A EN
Scanned by Jonny Oddene for Sintran Data © 2011