Page 1¶
Product Information¶
| Product Name | Product Number |
|---|---|
| Patch Kit for ND tpServer | 382300B |
Platform (211560) version B
Description of Product¶
Patch Kit for ND-211560 version B is a part of the Basic System Package for ND tpServer (ND-211560), which is a prepackaged system for the ND tpServer with menu oriented operation routines for easy operation.
The following products are corrected with this Patch Kit:
- 250360 M09 SINTRAN III revision (patch file version) 7400 for the M-version
- 210913 C01 SINTRAN III Monitor Call Package
- 211305 C05 ND-500/5000 System Package for SINTRAN III/VSX version M
Containing:- K02 ND-500/5000 Background Monitor
- L04 ND-500/5000 Swapper
- 211226 B05 Backup Manager
- 211304 B06 SIBAS/R
- 210794 E04 NOTIS-DS
- 211056 A06 Sprint Spooling System
- 210703 B00 File System Verification
- 210518 D07 User Environment
- 211327 D00 TCP/IP Basic Module III
- 211847 A01 ND-5830/5850 Microprogram
- 212176 E01 ND-5800 Microprogram
- 211275 E01 ND-5700 Microprogram
- 211274 E01 ND-5500 Microprogram
- 211273 E01 ND-5400 Microprogram
- 210337 I06 Backup System
- 211322 D02 DOMINO Maintenance Kit
- 211481 D01 DSS Test programs
- 211321 C03 NUCLEUS Maintenance Kit
Reason(s) for New Product or Version¶
The purpose for this product is to correct the errors discovered since versions B01 and B02 of the ND tpServer Platform.
Table of Contents¶
| Section | Page |
|---|---|
| 1 Read this first | 2 |
| 2 Documentation | 4 |
| 3 Packing List | 5 |
| 4 Manual Installation Procedure | 5 |
| 5 Errors Corrected | 15 |
| 6 Errors Known but Not Corrected | 41 |
| 7 Installing Special Modification Patches | 43 |
| 8 Selecting language version of products | 44 |
| 9 General Information | 46 |
| 10 Files modified or replaced by this Patch Kit | 47 |
ND-896058 EN 2
Page 2¶
Product Information¶
| Date | ND ServiceTeam | Page 2 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
1 Read This First¶
The following things are required in order to use this product.
- This Patch Kit requires versions B01 or B02 of the Basic Software Package for ND tpServer. If the version A09 or earlier of the Software Package is used, you must upgrade it to version B01 first. This Patch Kit is generated with a SINTRAN III/VSX-500 standard C (250306 M06) and a Patch file 7400 (250360 M09).
-
Changing the CPU-number in the UE-DATABASE:
UE will no longer do an automatic change of CPU-number on its database if the CPU-number is changed (or the database is moved to another machine). If the CPU-number is to be changed you must run the program (USER-ENVIRONMENT)UE-CHCPU-D07:PROG before you start the UE P-SERVER.
Even if the UE-DATABASE is not converted from another CPU, it is advisable to run this job because the 'machine name' sometimes is incorrect in the UE-DATABASE.
It is very important that this is taken care of before you start installing this upgrading kit.
The program UE-CHCPU-D07:PROG asks for the name of the database, the name and the CPU-number of the old machine. XMSG must be running and the local machine must be defined as the first machine name in XMSG.
The latest version of this program must be used. It can be copied from this Patch Kit to the user area USER-ENVIRONMENT.
-
Software Keys (210507B)
After installing this Patch Kit, all previously installed software keys are lost and must be reinstalled. Ensure that the diskette(s) with all necessary software keys are available before you start installation of this Patch Kit. UNIQUE is a product which requires a software key.
ND-896058 EN 2
[Photo: Scanned by Jonny Oddene for Sintran Data © 2022]
Page 3¶
Product Information¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
-
Output to a connected printer.
By changing the variable TINFO, you can choose if you want the output to the console to be written on a printer or on the terminal.
- TINFO = 0 : the output will be written on the terminal
- TINFO = 20 : the output will be routed to a connected printer
After installation of this Patch Kit, TINFO is set to 20. If TINFO and you do not have a printer connected to the console terminal, all output will disappear.
To change TINFO, the following procedure should be used:
@SINTRAN-SERVICE-PROGRAM *CHANGE DATAFIELD 1 I N Y Y TINFO/ nnn 0 (or 20) . *EXIT
-
Prerequisite for all ND tpServer models:
Console terminal
310 Mbyte System disk divided into two directories: - PACK-BASIC-BOO (DISC-2-SCSI-1,0,0) - PACK-MAIN-SW (DISC-2-SCSI-1,0,1)
Streamer drive (155 Mbyte)
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 4¶
Product Information¶
| Date | ND ServiceTeam | Page 4 of 58 |
|---|---|---|
| Date 92.06.15 | ND ServiceTeam | Page 4 of 58 |
Product Information¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Documentation¶
There is one manual for the ND tpServer describing different operation parts supported by a menu system, and how to maintain these operation parts. Necessary documentation for the product elements is included in the total delivery of the ND tpServer (ND-B70027 Basic Documentation Package for ND tpServer).
The most important operation documentation:
| Document | Document Number |
|---|---|
| ND tpServer System Administrator Guide | ND-830127.2 |
| SINTRAN III System Supervisor | ND-830003.7 |
| SINTRAN III User Guide | ND-860264.1 |
| Backup User Guide | ND-860250.2 |
| User Environment Reference | ND-860194.3 |
| Filoversikt Introduksjon | ND-860213.1 |
| File Manager Introduction | ND-860215.1 |
| File Manager Reference Card | ND-899053.1 |
| COSMOS User Guide | ND-860163.4 |
| Dialogue - SIBAS/R Introduction | ND-860256.1 |
| SPRINT User Guide | ND-860252.2 EN |
| SINTRAN III Commands Reference Manual | ND-860128.7 EN |
| SINTRAN III Monitor Calls | ND-860228.3 EN |
| SINTRAN III Quick Reference Card | ND-899020.2 EN |
| SINTRAN III Release Information, version M | ND-860230.7A EN |
| SINTRAN III Utilities Manual | ND-860151.3 EN |
| SINTRAN III Real Time Guide | ND-860133.2B EN |
| SINTRAN III Real Time Loader | ND-860051.8 EN |
| ND-100 Operator’s Communication Instruction Survey | ND-899016.2 EN |
| Operator panel ND-323163, how to use | ND-899030.1 EN |
| Performance monitoring, tuning and capacity planning | ND-830083.1 EN |
| Introduction to ND Office Systems | ND-860255.3 EN |
| Information Pamphlet for Norsk Data Customers | ND-840012.1 EN |
| File System Verification User Guide | ND-860354.1 EN |
| User Area Manager User Guide | ND-860367.1 EN |
| Configuration Dictionary User Guide | ND-860366.1 EN |
| PED User Guide | ND-860121.4 EN |
| ND-500 Loader/Monitor | ND-860136.4B EN |
| ND-SHELL Quick Reference Card | ND-899072.1 EN |
| TELEFIX Reference | ND-830040.2 EN |
| Backup Manager User Guide | ND-860276.3 EN |
| OEM User Guide | ND-860301.7 EN |
| OpenLAN Network Supervisor Guide | ND-830107.3 EN |
| DOMINO SCSI Operator Guide | ND-814009.1 EN |
| ND-LINKER User Guide & Reference | ND-860289.2 EN |
| Dialogue - SIBAS/R Application Development (DML) | ND-860290.2 EN |
| Dialogue - SIBAS/R DML Quick Reference Card | ND-899078.1 EN |
| Dialogue - SIBAS/R Database Definition (DRL) | ND-860282.2 EN |
| Dialogue - SIBAS/R DRL Quick Reference Card | ND-899051.1 EN |
| Dialogue - Operations | ND-830072.3 EN |
| COSMOS Operator Guide | ND-830025.2 EN |
| COSMOS Operator Card | ND-899002.0 EN |
ND-896058 EN 2
[Scanned by Jonny Oddone for Sintran Data © 2022]
Page 5¶
Product Information¶
| Date | ND ServiceTeam | Page 5 of 58 |
|---|---|---|
| 92.06.15 |
Product name
Patch Kit for ND tpServer Platform (211560) version B
Product number
382300B
3 Packing List¶
382300 A - 1 Streamer Cassette including all files necessary for this upgrade.
The Software Key (SOFTICE) for NOTIS-DS.
4 Manual Installation Procedure¶
___________________________
| CAUTION! |
|___________________________|
| Before you start this |
| installation procedure, |
| ensure that you have an |
| image backup of |
| PACK-BASIC-BOO and |
| PACK-MAIN-SW |
| Set the system unavailable|
| and get all users to stop |
| working on the machine. |
|___________________________|
-
Log in as user SYSTEM and do a controlled shutdown of the machine.
@MODE (MODE-FILES)SYSTEM-SHUTDOWN,,,, -
Check the size and number of files for some user areas
This is a job that must be done manually.
The directory PACK-BASIC must have at least 4500 unreserved pages.
User area Free Pages Free File Entries PACK-BASIC-BOO:RT 1100 - PACK-BASIC-BOO:SYSTEM 1650 16 User area PACK-MAIN-SW:RT must have no files and no space. Files on this user must either be moved to user PACK-BASIC-BOO:RT or be deleted. When all files are deleted, use the command
@TAKE-USER-SPACEto remove all user space from PACK-MAIN-SW:RT.
ND-896058 EN 2
Page 6¶
Product Information¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 3823000B |
3. Copy the First 6 Files from the Streamer Cassette¶
Insert the streamer cassette into the drive
Log in on user area SYSTEM and start the BM-OPERATOR.
@BM-OPERATOR
BmOp: COPY
Object Copy method Incremental
SINTRAN FILE NO
From Volume name Computer name Device name U S Control
VOLUME TPSERVER-B03 STREAMER-1 0
To Computer name Directory name User area Mode
DIRECTORY PACK-BASIC-B SYSTEM Of,Nc
Selection File name Selection date
INCLUDE
Select execution mode (Manual/Stop-on-error/Automatic): MANUAL
Reel: 01 Volume: TPSERVER-B03 Directory: TP-PLATFORM.TP-B03
COLD-START-SEQ:MODE START
SHORT-NENT:MODE START
BEFORE-COPY:MODE START
BM-OPERATOR-B05:DOM START
BM-OPERAT-XX-B05:SEG START
LIST-IMPLEMENTED:PROG START
ER-S3WD-DESC-D06:EDAT CANCEL
Do you really want to ABORT the operation (Yes/No): Yes
The streamer will rewind and you can push the EXIT-key to exit from the
BM-OPERATOR and return to SINTRAN.
This operation takes about 3 minutes.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 7¶
Product Information¶
| Date | ND ServiceTeam | Page |
|---|---|---|
| 92.06.15 | 7 of 58 |
Patch Kit for ND tpServer Platform (211560) Version B¶
| Product number |
|---|
| 382300B |
4. @LIST-IMPLEMENTED@¶
If you find SINTRAN-patches on the machine that is not included in the list below, these must be run as extra patches. Note that some patches are special modification patches, and will be handled in the AFTER-COPY:MODE if you edit the file PF-MODIF-M:MODE correctly.
This is a list of minimum patches on platform B03:
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | |
|---|---|---|---|---|---|---|---|---|---|---|
| 0 | A | A | A | A | A | A | A | A | A | A |
| 10 | C | A | A | A | A | A | A | A | A | A |
| 20 | A | A | B | C | A | B | A | A | A | A |
| 30 | A | A | ||||||||
| 40 | A | A | A | A | A | A | A | |||
| 50 | A | A | A | A | A | A | A | A | A | A |
| 60 | A | A | A | A | A | |||||
| 70 | A | |||||||||
| 80 | A | A | B | A | ||||||
| 90 | A | A | A | A | A | A | A | A | A | |
| 100 | A | A | A | A | B | A | A | A | B | |
| 110 | A | A | A | A | A | A | A | |||
| 120 | A | B | A | A | A | A | A | A | ||
| 130 | A | A | A | A | A | A | A | B | ||
| 140 | A | A | B | A | B | A | B | |||
| 150 | A | A | A | A | A | B | A | |||
| 160 | A | A | A | A | A | A | A | B | ||
| 170 | A | A | A | A | A | A | ||||
| 180 | A | B | A | A | A |
5. @MODE COLD-START-SEQ:MODE,,,,'¶
This MODE-job will prepare the COLD-START to automatically start the file SHORT-HENT:MODE.
The output from the SHORT-HENT:MODE you will find on the file HENT-OUTPUT:LIST.
This procedure takes only a few seconds.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 8¶
Product Information¶
Date: 92.06.15
Page: 8 of 58
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
6. Cold-Start¶
Note: Automatic start of the SHORT-HENT:MODE file is implemented.
Do NOT abort this job with the ESCAPE-key!
The sequence will finish with the message:
-- SYSTEM IS AVAILABLE, AND READY FOR PATCHING. --
This procedure takes about 4 minutes.
Log in as user area SYSTEM.
7. QMmode Before-Copy:Mode,"Before-Copy:List"¶
This MODE-job will do some preparations on different users before you start copying from the streamer cassette.
Some files are deleted and some files are renamed.
This procedure takes about 4 minutes.
8. Copy All Files from the Streamer Cassette¶
Insert the streamer cassette into the drive if it is not already inserted.
Check that you are on user area SYSTEM, and start the program BM-OPERATOR.
@ND ()BM-OPERATOR~
BmOp: COPY
Object Copy method Incremental
SINTRAN~ FILE~ NO~
From Volume name Computer name Device name U S Control
VOLUME~ TPSERVER-B03~ STREAMER-1~ 0~ ~ ~
To Computer name Directory name User area Mode
DIRECTORY~ ~ PACK-BASIC~ ~ Of,Nc,Ce~
Selection File name Selection date
EXCLUDE~ (SYSTEM)BM-OPERAT~
~ ~ ~
Select execution mode (Manual/Stop-on-error/Automatic): STOP-ON-ER
The streamer will rewind and you can push the EXIT-key to exit from the BM-OPERATOR and return to SINTRAN.
This operation takes about 25 minutes.
ND-896058 EN 2
Page 9¶
Product Information¶
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
9. Clean Up User Area ND-OPERATIONS¶
Log in as user area ND-OPERATIONS and execute the commands:
@COPY-FILE
"(PACK-MAIN:ND-OPERATIONS)BM-FILERE-PARA:DATA"
(PACK-BASIC:ND-OPERATIONS)BM-FILERE-PARA:DATA
@DELETE-USERS-FILES (PACK-BASIC:ND-OPERATIONS) N
Log in as user area SYSTEM and execute the command:
@DELETE-USER PACK-BASIC:ND-OPERATIONS
10. Clean Up User Area MODE-FILES¶
Log in as user area MODE-FILES and execute the commands:
@COPY-FILE
(PACK-MAIN:MODE-FILES)START-SPRINT:MODE
(PACK-BASIC:MODE-FILES)START-SPRINT:MODE
@DELETE-USERS-FILES (PACK-BASIC:MODE-FILES) N
Log in as user area SYSTEM and execute the command:
@DELETE-USER PACK-BASIC:MODE-FILES
11. Modifying for Special Modification Reports (SM Reports)¶
If you do not want to run any SM reports, verify that the file (CONFIG-FILES)PF-MODIF-M:FADM exists and consists of only one line containing the character @.
If you want to run some Special Modification patches, you must edit the file (CONFIG-FILES)PF-MODIF-M:FADM before you run the file (SYSTEM)AFTER-COPY:MODE.
A list of Special Modification Reports is found on page 23.
The file (CONFIG-FILES)PF-MODIF-M:FADM must contain the library mark for the SM report(s). After editing it should look like this (7-bit format):
PN031
PN035
@
If you want to install additional SM patches at a later stage, follow the procedure described on page 43.
Page 10¶
Product Information¶
Product Name
Patch Kit for ND tpServer Platform (211560) version B
Product Number
382300B
12. New Microprogram for the ND-5000 CPU¶
New microprogram for the ND-5000 CPU is copied to the user area SYSTEM:
MICRO-5850-12010:DATA for ND-5850 CPU
MICRO-5830-12010:DATA for ND-5830 CPU
MICRO-5800-B32:DATA for ND-5800 CPU
MICRO-5700-B32:DATA for ND-5700 CPU
MICRO-5500-B32:DATA for ND-5500 CPU
MICRO-5400-B32:DATA for ND-5400 CPU
Copy the appropriate file to the file CONTROL-STORE:DATA before you start the cold-start.
To get the CPU type for the machine you can do this:
@ND
ND-5000: VERSION ↵
Subsystem part:
System part...:
Swapper.......:
Micro program.:
CPU type......:
Accp version..:
Module:
ECO no:
Delete the files not needed on your system.
13. Edit the File (MODE)CONFIG-FILES:MODE:¶
Use an editor to edit the files(MODE)CONFIG-FILES:MODE.
The following two lines must be removed:
@CREATE-FILE (CONFIG-FILES)TCP-BA-LOAD-B:MODE,,,
@COPY-FILE (CONFIG-FILES)TCP-BA-LOAD-B:MODE (TCP-IP)TCP-BA-LOAD:MODE
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 11¶
Product Information¶
| Date | ND ServiceTeam | Page 11 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
14. Edit the LOAD-MODE:MODE File to Reflect Actual Memory Size¶
Read the file (SYSTEM)LOAD-MODE:MODE into the editor PED and edit the commands used to initialize the ND-500 Monitor to reflect the actual memory configuration:
The example below assumes 8% Mbyte memory in the ND-100 part and 32 Mbyte memory on the MF bus (ND-5000 part).
@CC ---------------------------------------------------
@CC - Initialize ND-500-MONITOR
@CC - Prior to this task @START-SERVER is performed.
@CC - Take 500 pages to DMASRV.
@CC ---------------------------------------------------
@ND-500-MONITOR 1
@CC
@CC If you have a special memory configuration you could put it in
@CC here by using the following command:
@CC
@CC DEFINE-MEMORY-CONFIGURATION
@CC 10400 [10400₈ = 8% MB]
@CC 27400 [32MB-8%MB = 23%MB of MF-bus memory is visible from ND-100]
@CC Y
@CC Y
@CC N
@CC 10400 [All of MF-bus memory is visible from ND-5000]
@CC N
@CC Y
@CC Y
@CC Y
@CC CHANGE-CPU 2 [Handle CPU number 2 if applicable]
@CC LOAD-CONTROL-STORE,,,,
@CC CHANGE-CPU 3 [Handle CPU number 3 if applicable]
@CC LOAD-CONTROL-STORE,,,,
CHANGE-CPU 1
LOAD-CONTROL-STORE,,,,
START-SWAPPER
TAKE-N500-PAGES 400D,,
EXIT
Edit the commands relating to your memory configuration and/or CPU configuration if applicable.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 12¶
Product Information¶
| Date | ND ServiceTeam | Page 12 of 58 |
|---|---|---|
| 92.06.15 |
Product name¶
Patch Kit for ND tpServer Platform (211560) version B
Product number¶
382300B
15. @MODE AFTER-COPY:MODE,'AFTER-COPY:LIST'~¶
This mode file will do all the patching on the platform:
- SYSTEM
- READ-SEGMENT:MODE
- INST-SPEC-MODIF:MODE
- S3-CONFIG GENERATE
Check the file AFTER-COPY:LIST to find out if there is any error messages from the patching.
This procedure takes about 5 minutes.
16. @(SPRINT-USER)IN-PRM~¶
Run the program IN-PRM to update the SPRINT Spooling System, select the option:
(1) INITIATE SPRINT
17. @COLD-START~¶
NOTE: Automatic start of the HENT-MODE:MODE file is implemented.
Do NOT abort this job with the ESCAPE-key!
Some information will appear on the console and the console printer informing the operator that the different software products are loaded.
When the cold start sequence is finished, the system is automatically restarted.
Some information will appear on the console and the console printer informing the operator that the different software products are started. The same messages will appear during a normal warm start sequence.
When the system is restarted, the following text is displayed on the console printer and on the console:
The ND tpServer is available
The installation is now complete and the ND tpServer is ready to run with a new version of the basic software.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 13¶
Product Information¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
18. @MODE (SYSTEM)REMOVE-FILES:MODE,,,¶
This mode file will remove all files used during installation.
This file itself has to be removed with the command
@DELETE-FILE REMOVE-FILES:MODE
┌─────────────────────────────────────────────────────┐
│ CAUTION! │
├─────────────────────────────────────────────────────┤
│ Remember to take a complete backup of the System │
│ disks (PACK-BASIC-BOOT and PACK-MAIN-SW). This is │
│ for security reasons in case of disk problems later │
│ on. │
└─────────────────────────────────────────────────────┘
19. Link Applications Using SIBAS/R to the New Version of the SIBAS Library¶
All applications using SIBAS/R must be linked to the new version of the SIBAS library (SIBR-B)SIBR-LIBRARY-B06:SEG.
Use the ND-Linker (assuming the application is called APPLICATION:DOM):
@LINKER
NDL(ADV): LINKER-SERVICE-PROGRAM
NDL(SRV): CHANGE-FILE-REFERENCES APPLICATION:DOM
Old string name: (SIBR-B)SIBR-LIBRARY-B05:SEG
New string name: (SIBR-B)SIBR-LIBRARY-B06:SEG
xx substitutions done in domain APPLICATION:DOM
NDL(SRV) EXIT
NDL(ADV) EXIT
20. Select Language Versions of a Few Products¶
The products SIBAS Manager and File Manager are available in both English and Norwegian. In both cases, language is set globally for all users of the system.
Similarly, the default language in User Environment can also be set globally.
Furthermore, the SPRINT Spooling System is available in Danish as well as English and Norwegian.
Refer to page 44 for more information about selecting the language version for these products.
Page 14¶
Product Information¶
| Date | ND ServiceTeam |
|---|---|
| 92.06.15 | Page 14 of 58 |
Product name
Patch Kit for ND tpServer Platform (211560) version B
Product number
382300B
21. Redefine the NOTIS-DS Database¶
+---------------------------------------------+
| NOTE! |
|---------------------------------------------|
| These procedures for verification and |
| redefinition of the NOTIS-DS database may |
| take considerable time on large databases |
| (several hours). |
| |
| It is not required that you include this as |
| part of the installation, but you should |
| note that the procedures are necessary and |
| must be done. However, we recommend that |
| you postpone them to a convenient time. |
+---------------------------------------------+
+---------------------------------------------+
| NOTE! |
|---------------------------------------------|
| The following only applies if you have a |
| version E database and you have NOT already |
| performed a redefinition of the indexes in |
| HIERARC. |
| |
| If in doubt, run a verification of the |
| indexes using SIBR-DBM. If the indexes |
| USIDGRP, USTCRE, USTMOD and USTREF exist |
| in the tables HIERARC, the redefinition |
| has already been run. |
+---------------------------------------------+
Log in as user area DSBASE and execute the following commands to copy files from user area DS-PROGRAMS to user area DSBASE:
@COPY-FILE "REDEF-IX:MODE" (DS-PROGRAMS)REDEF-IX:MODE
@COPY-FILE "REDEF-IX-DSBASE:DRL" (DS-PROGRAMS)REDEF-IX-DSBASE:DRL
Use an editor to edit the file REDEF-IX-DSBASE:DRL to include the DBA-password for your database.
(NOTE: Store in 7-bit format!)
NOTE: Ensure you take a complete backup of your database before running the redefinition!
To run the redefinition, log in as user area DSBASE and execute the command:
@MODE REDEF-IX:MODE,,,,,
After the redefinition, check the list file REDEF-IX:LIST to ensure that the run was successful.
Install the software key for NOTIS-DS.
Page 15¶
Product Information¶
| Date | ND ServiceTeam | Page 15 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Errors Corrected¶
All reported errors are corrected except those listed in section 6.
Errors corrected since revision B02 of the platform, are marked with a change bar.
-
SINTRAN III/VSX-500 Standard system C (250306 M06):
The patch-file 7400 is included as 28 :BPUN files. The file SM-PATCHES-7400:PATC includes all special modification patches.
-
Patch-file 7400
Report no.: 188 A Program: ALL Subject: @FILE-SYSTEM-ERROR-MESSAGE Symptom: The system will sometimes stop/hang, if FILE-SYSTEM-ERROR- MESSAGES is on.Report no.: 186 A Program: Nucleus Subject: Unnecessary start of the RT-program NKSERV Symptom: Bad performance on system where a lot of Nucleus descriptors are defined in the SINTRAN III configuration program or simply the system hangs with NKSERV using 100 % CPU.Report no.: 183 A Program: ND-5000 Subject: RFILE/WFILE in ND-5000 Symptom: Error: MAKESEG: Specified physical page not found in memory map.Report no.: 182 B Program: All Subject: Too many Octobus kicks in the kernel Nucleus Symptom: The System hangs on level 2.Report no.: 181 A Program: All Subject: Monitor Call ADP functions 1 and 2 Symptom: Terminal hangs in UE-RUN and the server NKSERV will use almost 100 % CPU.
ND-896058 EN 2
Page 16¶
Product Information¶
| Date | ND ServiceTeam | Page 16 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report 180 A¶
- Program: ND-5000
- Subject: RFILE/WFILE in ND-5000 if system has more than 32 Mbyte.
- Symptom: Error: MAKESEG : Specified physical page not found in memory map.
Report 178 A¶
- Program: ND-5000
- Subject: ND-5000 Lock Timeout.
- Symptom: The ND-5000 is terminated with error message ND-5000 Lock Timeout.
Report 175 A¶
- Program: All
- Subject: @CLADU or @UPDAT may cause PROMAN to terminate the Domino controllers.
- Symptom:
- DP-100/TCPD: Missing Domino heartbeat, controller aborted.
- PROMAN : Controller terminated on request.
Report 172 A¶
- Program: All
- Subject: Error in RT-LOADER command DUMP-SEGFILE-BITMAP.
- Symptom: If number of continuous free pages on segment file is > 1000000, number of continuous free pages listed is 0.
Report 171 A¶
- Program: All
- Subject: Hang on level 1, if command @FILE-SYSTEM-ERROR-MESSAGE is used.
- Symptom: Hang in routine SPUSH, if output file is used, and the error "NO MORE PAGES AVAILABLE FOR THIS USER" has occurred.
Report 170 A¶
- Program: All
- Subject: Missing contact with Nucleus.
- Symptom: Errors: No contact with SIBAS Process. Illegal user identifier. Status -57 etc.
Report 169 A¶
- Program: All
- Subject: Error in MTAD timeout routine.
- Symptom: MTADs hanging in I/O-wait after disconnect from file system.
ND-896058 EN 2
Scanned by Jonny Odden for Sintran Data © 2022
Page 17¶
Product Information¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report No.: 167 B¶
- Program: All
- Subject: Error in MON MAGTP on block-oriented internal devices.
- Symptom: Error message "Buffer size too big for buffer previously obtained" is given.
Report No.: 166 A¶
- Program: SCSI driver
- Subject: Error when reading from Exabyte GTS streamer.
- Symptom: Error message on error device: Serious SCSI magnetic tape error - 63020B - Memory Address Register not as expected.
Report No.: 163 A¶
- Program: All
- Subject: Error in RT-LOADER command BINARY-DUMP.
- Symptom: Transfer from segment file is going the wrong way.
Report No.: 161 A¶
- Program: All
- Subject: @DELETE-SPOOLING-FILE
- Symptom: File is deleted from the queue, but is still marked as used.
Report No.: 160 A¶
- Program: All
- Subject: Patch to speed up OUTBYTE from ND-500 to MTADs.
- Symptom: Bad performance, especially when running X Window System.
Report No.: 159 A¶
- Program: All
- Subject: Error in 5MTRANS.
- Symptom: Read does not supply correct data when reading from disk unit ≠ 0.
Report No.: 158 A¶
- Program: All
- Subject: Terminals looping after @STOP-TERMINAL.
- Symptom: MINBHOLD in output data field has the value 100034.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 18¶
Product Information¶
| Date | ND ServiceTeam | Page 18 of 58 |
|---|---|---|
| 92.06.15 | Product Information |
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report Summaries¶
Report No.: 157 A¶
- Program: ALL
- Subject: Patch concerning call to ERRFATAL from routine RSWDF.
- Symptom: The output value of the L-register from ERRFATAL-routine is wrong.
Report No.: 156 A¶
- Program: ALL
- Subject: Hang in UE-login on some terminals.
- Symptom: Error message: UE Pserver is not available now.
Report No.: 154 A¶
- Program: COSMOS TCP/IP
- Subject: Restarting the COSMOS TCP/IP gateway.
- Symptom: System stops in Errfatal with Page Fault on level 2.
Report No.: 153 A¶
- Program: ALL
- Subject: @STOP-TERMINAL on a terminal with an ND-500 process, and TRUE termination handling enabled, may result in hang.
- Symptom: Hang on level 2.
Report No.: 151 A¶
- Program: ND-5000
- Subject: The LOOK-AT-HARDWARE commands can be used even when other ND-5000 processes are logged in. It needs report 150.
Report No.: 150 A¶
- Program: ND-5000
- Subject: Master Clear function in ND-5000 systems will not clear the FERROR flag if FERROR=2000 (ND-5000 Timeout).
Report No.: 149 B¶
- Program: ND-500/5000
- Subject: ND-500/5000 Timeout or hang in ND-500/5000 when the commands LOGOUT-PROCESS or ABORT-PROCESS are used.
- Symptom: All the ND-5000 processes will be waiting for the 5NAMS semaphore. Logical device 1107.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 19¶
Product Information¶
| Date | ND ServiceTeam | Page 19 of 58 |
|---|---|---|
| 92.06.15 |
Product Name¶
Patch Kit for ND tpServer Platform (211560) version B
Product Number¶
| 382300B |
|---|
Report no.: 147 A¶
Program: ND-500/5000
Subject: Escape when starting a ND-500/5000 domain.
Symptom: System hangs with deadlock for system semaphores.
Report no.: 146 A¶
Program: A11
Subject: Background allocation system does not log out terminals.
Symptom: Terminals are not logged out, even if timeout is enabled.
Report no.: 145 A¶
Program: ND-500/5000
Subject: Increase tolerance in ND-500/5000 timer routine to reduce number of timeouts.
Symptom: ND-500/5000 TIMEOUT (Error code 20008).
Report no.: 143 A¶
Program: VSX
Subject: Hang in DeletePage monitor call.
Symptom: If a file has pages within the last 512 possible in a subindexed file then the monitor call never completes.
Report no.: 142 A¶
Program: ALL
Subject: Error return from MON MEXIT, MCALL and SGMYT giving run time error 42 - Overlapping segments.
Symptom: The output value of the second segment number in the error message is wrong.
Report no.: 139 A¶
Program: ND-500/5000
Subject: Error in ND-5000 systems if Local Memory ≥ 16 Mbytes and 16 ≤ MF Multiport Memory ≤ 32Mbytes
Symptom: Overwriting in context block area leading to various traps from ND-500/5000 Swapper.
Report no.: 138 A¶
Program: VSX/500
Subject: Errors in ND-5850 Tracer operations.
Symptom: Unable to run tracer: Not allowed if users logged on. Wrong number of parameters and wrong copying of data for 'fast-dump' of trace memory.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 20¶
Product Information¶
| Date | 92.06.15 | Page 20 of 58 |
| ND ServiceTeam | ||
| Product Name | Product Number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report no.: 137 A¶
- Program: ND-500/5000
- Subject: Logout-process may result in hang.
- Symptom: Hang on level 1 in routine SPUSH.
Report no.: 135 A¶
- Program: VSX
- Subject: MON FDINA (GetDirNameIndex) and 16-character directory names.
- Symptom: Some software (for example Backup System) does not terminate the name string correctly resulting in the error ILLEGAL CHARACTER IN PARAMETER.
Report no.: 134 A¶
- Program: VSX/500
- Subject: Wrong layout in MF-controller’s (and Double Bus controller) error message printed by the SINTRAN III Watchdog.
- Symptom: Errlog, Maint.stat., etc. is rubbish unless you shift one line up.
Report no.: 133 A¶
- Program: VSX/500
- Subject: Error in ND-5000 ACCP-communication function ReadAIB32. Significant for test systems only.
- Symptom: Error when running test program SEMICS under SINTRAN M.
Report no.: 129 A¶
- Program: ALL
- Subject: Error in file page allocation. (OUTSIDE DEVICE LIMITS)
- Symptom: OUTSIDE DEVICE LIMITS when writing to a file which have to be expanded.
Report no.: 128 A¶
- Program: ND-5000
- Subject: SWAPPER STOPPED ERROR CODE: 132B
- Symptom: Swapper stops with error code 1328 when using generation 6 and ND-500/5000 Swapper version L01.
Report no.: 127 A¶
- Program: ALL
- Subject: TAD timeout routine.
- Symptom: System hangs on level 1.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 21¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 21 of 58
| Product Name | Product Number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report Details¶
Report No.: 122 A¶
- Program: ALL
- Subject: STC 1950 or 2922 magnetic tape and 3600 foot tape. Same problem as report number 297 for SINTRAN III version I.
- Symptom: Some functions may give "device error". One example is a LIST-VOLUME command when the volume covers all or most of a 3600 foot tape.
Report No.: 120 A¶
- Program: A11
- Subject: Short timeout on floppy DMA device.
- Symptom: The following message is printed on the error device
"FALSE INTERRUPT LEVEL 11 Identification code 21B".
Report No.: 119 A¶
- Program: A11
- Subject: Error in HDLC driver for BSC/DMA.
- Symptom: System stops on level 1410 with memory out of range.
Report No.: 118 A¶
- Program: ALL
- Subject: Monitor Call GetErrorDevice (MON 254 GERDV).
- Symptom: 'OUTSIDE SEGMENT BOUNDS' Page number 762.
Report No.: 117 A¶
- Program: ND-500/5000
- Subject: MON RFILE/WFILE from ND-500/5000
- Symptom:
- Error message from ND-500/5000: "TOO MANY FIXED MEMORY PARTS"
- Update of MFTABLE (local fix table) went wrong.
Report No.: 114 A¶
- Program: VSX/500
- Subject: Multi-CPU 5850 processor allocation. A process should be bound to the allocated CPU.
- Symptom: Not the best utilization of CPUs (modification).
Report No.: 111 A¶
- Program: ND-500/5000
- Subject: System crash when using RFILE/WFILE from ND-500/5000 with 0 bytes to read/write.
- Symptom: Fatal error from level 3 in routine LINKOVER.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 22¶
Product Information¶
| Date | ND ServiceTeam | Page 22 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report no.: 106 B¶
- Program: All
- Subject: Deadlock when stopping ND-500/5000 processes.
- Symptom: Deadlock (involving DEMF1) sometimes occurs when stopping ND-500/5000 processes (seen when stopping SIBAS/R version B).
Report no.: 10 C¶
- Program: All
- Subject: Taking a MEMTOF of more than 32 Mbytes of memory.
- Symptom: Not possible to dump to the first floppy diskette.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 23¶
Product Information¶
| Date | ND ServiceTeam | Page 23 of 58 |
|---|---|---|
| 92.06.15 |
Product Name¶
Patch Kit for ND tpServer Platform (211560) version B
Product Number¶
382300B
General Modification Reports¶
Report no.: 179 A
Program: ALL
Subject: Disconnect Remote File Access Data Segments when maximum limit is reached.
Report no.: 164 A
Program: UE-LOGIN
Subject: UE-LOGIN fails and "NO SCRATCH FILE" is written.
Special Modification Reports¶
Report no.: 190 B
Program: VSX
Subject: UPNOD 2000 switch, disconnect terminal when logging out.
Report no.: 177 A
Program: ALL
Subject: Error in SCSI low level driver. Systems with 32 MB memory may give error message: 63020 - MAR not as expected.
Report no.: 168 A
Program: ALL
Subject: Mon MAGTP functions 26 and 27 from ND-500/5000. Odd bytecount was not allowed.
Report no.: 152 A
Program: Driver
Subject: Special character in 8-bit mode will be accepted as XON character. The input character is masked with 1778.
Report no.: 140 D
Program: ND-500/5000
Subject: RFILE/WFILE to/from several address areas on ND-500/5000 segment. Error: Too many fixed parts or Error in monitor call.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 24¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page 24 of 58
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
Reports¶
| Report no. | Program | Subject |
|---|---|---|
| 130 A | ALL | Error in allocating a page in file system from the Swapper Fatal error from Swapper. Error 478. |
| 125 D | VSX | UPNOD 3000 switch, disconnect terminal when logging out. |
| 116 B | A11 | Special patch for ND Comtec Switzerland. Setting of XOFF for specific terminal. |
| 115 A | A11 | Batch output file opened for "overwrite" and not "write-append". |
| 83 A | A11 | Reduce maximum length of mail messages to 160 characters, to fit into X.29 buffer. |
| 79 A | NOTS | Error in VTM using 8-bit I/O on NOTS terminals. Error returned: "Illegal device type". Same as report number 4 for SINTRAN III version L. |
| 78 A | A11 | Problems with 8-bit I/O on terminals. Same as report number 193 for SINTRAN III version L. |
| 77 B | A11 | Patch to remove the form feed after the spooling trailer. Same as report number 171 for SINTRAN III version L. |
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 25¶
Product Information¶
| Date | ND ServiceTeam | Page 25 of 58 |
|---|---|---|
Patch Kit for ND tpServer Platform (211560) version B¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report no.: 76 B¶
Program: A17
Subject: Patch to remove the form feed at the end of the spooling print if the spooling trailer is present. Same as report number 170 for SINTRAN III version L.
Report no.: 75 A¶
Program: A11
Subject: Patch to remove form feed at the start of the spooling print if the spooling header is present. Same as report number 169 for SINTRAN III version L.
Report no.: 74 A¶
Program: A17
Subject: Patch to remove the form feed after the spooling header. Same as report number 168 for SINTRAN III version L.
Report no.: 73 A¶
Program: A11
Subject: Patch to treat empty spooling form as normal string. Same as report number 156 for SINTRAN III version L.
Report no.: 72 B¶
Program: ALL
Subject: Spooling header with rotating alphabetic characters (instead of *) gives more even wear on character set. Same as report number 154 for SINTRAN III version L.
Report no.: 70 A¶
Program: All
Subject: How to remove one linefeed between each document on printer with tractor feed.
Report no.: 69 A¶
Program: ALL
Subject: Removes 'END OF FILE' message after @COPY command.
Report no.: 68 A¶
Program: VSX
Subject: Reduce interrupt load from HDLC connected to digital line, (for example British Telecom's Kilostream).
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 26¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 26 of 58
Patch Kit for ND tpServer Platform (211560) Version B¶
Product Number: 382300B
Report no.: 67 A¶
- Program: A11
- Subject:
Make monitor call EXABS (335) available on ND-500/5000.
Same as report number 180 for SINTRAN III version L.
Report no.: 62 A¶
- Program: A11
- Subject:
Patch to include terminals using 3270- or VIP-emulator in
@TERMINAL-STAT list, or when MON TERST is used.
Report no.: 43 A¶
- Program: vsx
- Subject:
Restart after buffer full on internal devices. For
implementation and use see report 44.
Report no.: 36 A¶
- Program: A11
- Subject:
Patch to reset the Error Device to terminal 1 when logging out
from the terminal which is the Error Device.
Report no.: 35 A¶
- Program: BP-2000 printer
- Subject:
Paper Instruction Command and Character conversions on BP-2000
printer. For implementation and use: see report 33.
Report no.: 34 A¶
- Program: A11
- Subject:
Patch to obtain Remote-Form-Feed on Versatec plotter without
"print option", connected to ND-100 with a DMA interface.
Report no.: 32 A¶
- Program: DMA-printer
- Subject:
Paper Instruction Command and character conversions on DMA
printers. For implementation and use, see report 33.
Report no.: 31 A¶
- Program: A11
- Subject:
How to drop DTR (Data Terminal Ready), when logging out. This
applies to special devices not supplied by ND.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 27¶
Product Information¶
Date: 92.06.15
Page: 27 of 58
ND Service Team
Product Name¶
Patch Kit for ND tpServer Platform (211560) version B
Product Number¶
382300B
- ND-500/5000 Swapper version L04 (part of ND-500/5000 System Package for SINTRAN III/VSX version M (211305C05))
| Report no. | Title |
|---|---|
- There might be trashing (100% swapping) if ND-5830/5850 and large FIX areas.
- Swapper does not move IX pages OVER 32MB during FIX so frequently.
- Change of strategy for selecting memory if own CPU memory on the ND-5830/5850 is exhausted.
- Fatal error from Swapper, error code 1008 might sometimes occur. This is related to 'unfix' (which can be invisible to the application) and the use of the 'sequential' mode in 'file as segment' segments.
- Fatal error from Swapper, error code 2078 (Pagefault in Swapper), after a Disc Transfer Error (message). Internal error. Some internal variables not reset upon error return from segment flush (WSEG).
- Error in Fix_Segment.
If 'FixToLimits' (-1) and segment size is zero ('FileAsSegment' opened for write), size will be set to 65565 (1777778).
If you have enough memory for the Swapper to accept this, it will fail during page allocating to the file system, and leave memory links looped. This in turn will lead to the Swapper looping at 100% CPU later.
- Clear TSB inserted for multi ND-5830/5850, because expected trouble at marginal timing.
- No. of sectors per page in Swapper’s segment table entry is sometimes set to 4; lead to overwriting of memory and the error message: SWAP DEVICE ERROR.
- Error in BIM flush of SIBAS/F.
SIBAS work area (IBLAN) is sometimes overwritten, and the result will be SIBAS INTERNAL ERROR.
The warning TRYING TO RELEASE ILLEGAL BUFFER may occur first.
- Error if ND-5830 or ND-5850 CPU and extra MF-memory.
If segment to be fixed needs more than the available memory pages in ND-5850 CPU, the index pages were not correctly allocated. Swapper stops in fatal error.
ND-896058 EN 2
[Scanned by Jonny Oddone for Sintran Data © 2022]
Page 28¶
Product Information¶
| Date | ND ServiceTeam | Page |
|---|---|---|
| 92.06.15 | 28 of 58 |
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report¶
| Report no. | Title |
|---|---|
- Error in fix segment.
If fix segment and the segment to be fixed is involving more than two free-parts (One free-part is 8 Mbytes).
Swapper stops in fatal error.
- Error 15g if Multi-CPU (ND-5830 or ND-5850).
- NOTIS-DS for ND-500/5000 (210794E04)
| Report no. | Title |
|---|---|
- Fatal error in the emulator server. SINTRAN seems to be "hanging" and the file ER-S3WD-LOG:DATA is corrupted.
- Maximum number of users simultaneously connected to the emulator server is 25, should be 40.
- When creating a user area in UE-PMAN (version D) and standard NOTIS-DS archive is specified, then MAILBOX with INTRAY and OUTTRAY will not be created automatically.
- Using DS-BACKUP to copy documents from a NOTIS-DS version D database to a NOTIS-DS version E database, not being a supervisor user, gave error message 'You are not authorized to write this attribute'.
- Fetching documents from NOTIS-DS version E02 sometimes gave only part of document. This due to wrong max. bytepointer. The symptom was in NOTIS-WP that only the first part of the document was fetched and in NOTIS-CALC that the program hung.
- The List/Start command did not differ between document names ending in hyphen (-) and document names not ending in hyphen but equal up to the hyphen character.
- The List/Start command would list all ambiguous document names even if there was one unique name.
- The command Administration/Copy hierarchy also copied the documents while it should only copy the drawers and folders.
- Copying an empty document from SINTRAN gave error message 'No such page' and the copying halted.
ND-896058 EN 2
Page 29¶
Product Information¶
| Date | ND ServiceTeam | Page 29 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
SPRINT Spooling System (211056A06)¶
Report no.
| Title |
|---|
| OpenLAN printers failed with the message 'Device not reserved'. |
| The error message "Impossible to send data to printer" occurred too often. If you still get this problem with printers connected to an 8-terminal interface, you should increase the buffer size on the device on input. |
| SPRINT could close files opened by other RT-programs if the peripheral file is deleted for an OpenLAN printer. |
| When having close to 60 local and remote printer definitions, SPRINT could sometimes fail to start the local printers. |
| SSY-SYSF:DATA could be overwritten and cause various problems. |
| Output files could be printed twice. |
| Printer definitions could be mixed. This could result in listings being printed on wrong printer. |
| The SSY-PICT files on the ND-5000 ES and ND-tpServer platforms must reside on user area SPRINT-USER instead of ND-OPERATIONS. |
| The remote printer definition on the last entry in SPRINT disappeared after restart. |
| Unconverted printouts via SINTRAN spooling now use default form in SPRINT. |
Other hints:
If a printer gives an error message in SPRINT, you should check the printer itself before you stop and start the printer in SPRINT. Unnecessary restarting of printers will jam SPRINT, and you may end up with the message 'Sprint is busy'.
If the error device does not work, you will also get 'Sprint is busy'.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 30¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 30 of 58
Product Name¶
Patch Kit for ND tpServer Platform (211560) version B
Product Number¶
382300B
- SPRINT Standard Printer Drivers (211058306):
| Report no. | Title |
|---|---|
| - | Last line on page on FACIT-720/730 was lost. |
| - | Lines with leading spaces were displaced. |
| - | Superscript 2 and 3 had wrong underlining on Canon and Epson. |
| - | Underlining of blank lines did not work. |
| - | Font changes could give wrong character set. |
| - | The FCB control characters had no effect. |
| - | Driver could close files opened by other RT-programs. |
| - | The PSCRIPT-driver now supports dual-bin. |
| - | Driver did not select 7/8 bit mode correctly |
| - | Personal printers did not accept 8-bit output files. |
| - | PSCRIPT output was ignored on QMS-410. |
| - | Underlining appeared too high on some QMS-printers. To solve this, the first parameter in printer info 1 should be set to 1. |
| - | Y with acute accent did not work on PSCRIPT. |
| - | Some PSCRIPT printers could hang after a printout. |
| - | Landscape did not work properly on ND-720/730. |
| - | National code 17 (New Norwegian) is now supported. |
| - | Some problems with FF-after on LINE-PRINTER is corrected. |
| - | Manual feed on CANON LBP8 now works without having to push the FF-button. |
| - | Driver now allows the TIU to signal busy by sending reset. Driver will no longer stop when receiving 'SLEnetreset' or 'SLEtimedout' from SLIB. |
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 31¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 31 of 58
Product Details¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
- SPRINT Printer Driver for HP LaserJet Printers (211049506):
| Report no. | Title |
|---|---|
| - | Last line on page on ND-708 was lost. |
| - | Lines with leading spaces were displaced. |
| - | Underlining of blank lines did not work. |
| - | Font changes could give wrong character set. |
| - | Y with acute accent did not work on PCL4. |
| - | Personal printers did not accept 8-bit output files. |
| - | Driver could close files opened by other RT-programs. |
| - | National code 17 (New Norwegian) is now supported. |
| - | OKI-800 gave a blank sheet when accessing lower input bin. |
| - | Driver now allows the TIU to signal busy by sending reset. Driver will no longer stop when receiving SLEnetreset or SLEtimedout from SLIB. |
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 32¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 32 of 58
Product Details¶
Product Name: Patch Kit for ND tpServer Platform (211560) Version B
Product Number: 382300B
Backup Manager for ND-500/5000 (211226B05):¶
| Report no. | Title |
|---|---|
| 1 | BM-Op sets correct JEC completion code upon error. |
| 2 | Non-valid commands is ignored when running BM-Op from Batch/Mode. |
| 4 | LIST-VOLUME works on volume spliced on more NON-SCSI media. |
| 5 | Correct error message is given upon error during copying an indexed file to volume. |
| 6 | If 'ChAb' or 'ChCo' is given for a backup of a SIBAS/F database only a warning message is given before continuing with the backup operation. |
| 9 | Using BM-FileRestore to restore a file without giving destination file type, the data type chosen will be the one found on the volume and not :DATA. |
| 10 | 'Unsufficient loaded segment' should not be seen if BM-Op is installed without link to SIBAS. |
| 14 | Correct batch is chosen by Scheduler when 0 is specified. |
| 15 | 'Compare error on page 0' on system disk should not occur. |
| 16 | Special generated SINTRAN versions with a non-standard number of directory entries are correctly handled. |
| 17 | Reservation procedure of destination device have been corrected. |
| 18 | Reservation of database (Db-Control = 'Fc' or 'Sc') works even if no R-log is defined for the database. |
| 20 | R-log is reset after db-backup (no mirroring case). |
| 22 | Copying an indexed file > 65536 pages is possible by using blocksize = 1 (FILE-LOCAL-BLOCKSIZE). |
| 24 | 'Db wait time' may be set to 10 minutes or more. |
| 25 | LIST-VOLUME may list objects of any size. |
| 26 | Temporary mirror pools are deleted after use. |
| 27 | BM-Definition. EDIT on any field in a job should be safe. |
ND-896058 EN 2
Page 33¶
Product Information¶
| Date | ND ServiceTeam | Page 33 of 58 |
|---|---|---|
| 92.06.15 |
Product name¶
Patch Kit for ND tpServer Platform (211560) version B
| Product number |
|---|
| 382300B |
Report no.¶
| Title |
28 Name of temporary mirror pool is reduced to 15 characters ('TEMP-BM-POOL-xx') in order to be able to enter it in SINTRAN if not reconnected/deleted after backup.
29 Spooling files may be restored from volume.
30 A Volume may be spliced on 2 or more floppies.
31 Improved error handling in 'Automatic' execution mode.
32 Both main pool and mirror pool are updated when restoring a contiguous file from volume to a directory on a mirrored pool.
34 Correct error message is given if no batches are available at start-up time.
35 Correct volume name is written to volume in connection with INCREMENTAL DB backup (R-log only).
36 BM-Scheduler. The complete name of the output-file for a scheduled entry is not restricted to 35 characters.
37 Routing the output from LIST-VOLUME directly to a printer will not destroy the object entry of the peripheral file.
39 Correct volume name is written to volume in connection with backup a database for which no R-log is defined.
41 Backup of more databases stored on Domino disks from one SET should not give Nucleus error.
42 The output to message device from BM-Scheduler have been adjusted to reduce buffer requirements.
- LIST-VOLUME from :MODE/BATCH with output to terminal didn't give correct output
- Error in updating of start-up time for periodically scheduled entries.
- Password occurred in error messages
- Algorithm to create temporary mirror pool was not secure
- No valid checking of scheduler time data was performed
- JEC-code was not correctly set in all error situations
- Blank user on directory was treated as significant
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 34¶
ND ServiceTeam¶
Product Information¶
Date: 92.06.15
Page: 34 of 58
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Issues and Reports¶
| Report no. | Title |
|---|---|
| - | Reporting of SIBAS-status upon error was insufficient |
| - | An extra empty line to end the Include/Exclude-lines was necessary in order to make the job work correctly |
| - | Use of EDIT command in BM-Definition could corrupt the SET |
| - | Authorization check was done AFTER positioning of tape |
| - | 'No such user in main dir.' was fatal for a file backup procedure. In B05 only a warning message is given |
| - | If 'Compare error', the next object specified in the job led to a 'Device error' due to lack of tape positioning before continuing |
| - | 'Compare error' from volume to disk didn't give correct source and destination device names |
| - | 'Copying' was not written to batch output-file if copying without use of DMA-Server/IDC |
| - | Page-numbers > 100000 wasn't correctly displayed |
| - | Option 'Expand user area' ('Ce'/'Ex') didn't make space for an index page when copying an empty file to disk |
| - | Number of directory indexes to search is increased from 44 to 128 for SINTRAN compatibility |
| - | JEC code for FIRST error occurred in AUTOMATIC mode is reported instead of the last one |
| - | Display of old density in connection with Set-Density command was not correct |
| - | Bm-Op didn't execute LOAD before SET-DENSITY |
| - | The DMA-Server is not tried connected with BLANK password |
| - | Batches with no > 10 wasn't correctly logged out in connection with reservation of directory |
| - | The HELP-pictures have been corrected |
| - | Neither DMA-Server nor IDC is tried used to copy a file from a ND-100 coupled disk to a Domino/SCSI coupled streamer/magnetic tape. |
| - | Too few pages was given to user when restoring files in expand mode if the bytecount of the file didn’t reflect the actual file size. |
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 35¶
Product Information¶
Product Details¶
| Date | ND ServiceTeam | Page 35 of 58 |
|---|---|---|
| 92.06.15 |
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
SIBAS/R (211304B06)¶
| Report no. | Title |
|---|---|
| 4 | Error in SIBAS-ONLINE-PRIORITY. |
| 6 | Error in SIBAS call SSCUR with option code 2 and 4. |
| 7 | Error in SIBAS call SEXMC. |
| 9 | Error in SIBAS call SGIXN if retry occurred. |
| 10 | Better utilization of SIBAS work area |
| 11 | Sort error on integer*2 indexes with duplicates allowed (DML) |
| 12 | Sort error on integer*2 indexes with duplicates allowed (DBM) |
| 13 | Sort error on integer*2 indexes with duplicates allowed (DRL) |
| 14 | Error in fetching schema information |
| 15 | Backup-manager may report fatal error in consistency check when doing backup of many databases in one backup set. |
| 17 | Error in NEW INDEX when more than 65535 pages are used on the system table |
| 18 | Error in VERIFY INDEX in regenerate mode when top-levels are beyond SIBAS page 65535 |
| 19 | Error in screen oriented SIBAS service when executing database status. |
| 20 | Error in CHANGE ROW LENGTH. |
| 21 | Error in NEW COLUMN on a table which contains wide-storage |
| 22 | Reduce length of timeout before retry (Nucleus version only). |
| 24 | Error in CHANGE TABLE-SIZE. |
| 25 | Error in redefinition when database contains wide-storage tables. |
| 26 | Error in SIBAS call SSCUR with option code 0, 3 and 4. |
| 29 | Error in currency handling. |
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 36¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 36 of 58
Product Details¶
| Product Name | Product Number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Report¶
| Report No. | Title |
|---|---|
| 30 | Modification patch to suppress the message: WARNING MT$WAIT * |
| 31 | Page-link error after LOAD APPEND. |
| 32 | Problems with recovery after installing a backup copy of a database. |
| 35 | Error message "SIBRC: Internal error" may appear on the error device when SIBAS is accessed from a Dolphin Server 300/500 front. |
| 36 | Errors during Consistency check. |
| 41 | Error in initialization of sort-merge for T-indexes. |
| 48 | Wrong message to error-device when B-log is full. |
| 49 | Run SCLDB SINGLE-thread if given user already has an active task. |
| 50 | Error in SINGLE thread execution. |
| 51 | Error handling after SQL-Open introduced. |
| - | Error status from SQL kernel will be returned unmodified to the application. |
| - | Not proper cleanup after fatal error in SQL kernel. |
| - | Wrong revision id for SQL server. |
| - | Error in CHANGE-TABLE on large tables. No. of used pages is > 65535 SINTRAN pages (or will be larger due to the redefinition). |
| - | The command BACKUP-FTX was allowed without the database open for update by you. |
| - | Close temporary files before (a new) SQLOPEN is done |
ND-896058 EN 2
Page 37¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 37 of 58
Product name:
Patch Kit for ND tpServer Platform (211560) version B
Product number:
382300B
Multi-Machine Operator Environment (211073A01)¶
| Report no. | Title |
|---|---|
| 5 | Error in Send-Message in OEM-STATU program |
| (see report no 4 if OLD DOMAIN FORMAT) |
User Environment (210518D07)¶
| Report no. | Title |
|---|---|
| 1 | No test for the situation 'Line lost' in UE-LOGIN. |
| 2 | Terminals are 'hanging' in UE-PMAN. |
| 3 | Maximum number of users in UE is set to 50. |
| Can be changed by using 'UE-FUNC,16 |
- The internal table, causing the error message "NO MORE SPACE ON USER USER-ENVIRONMENT", is expanded.
- The problem that a login takes very long time when the ASCII form of a CPU-number contains a Space or a '#', is fixed.
- The problem with session tables filled up is fixed.
- The error with UE-EDIT creating Swedish menu source-files with language suffix SV instead of SW is fixed.
ND-896058 EN 2
Page 38¶
Product Information¶
Date: 92.06.15
Page: 38 of 58
ND ServiceTeam
Product Name¶
Patch Kit for ND tpServer Platform (211560) version B
Product Number¶
382300B
TCP/IP Basic Module III (211327D000)¶
| Report no. | Title |
|---|---|
- TCPD and Waste of Nucleus Resources
The previous versions did not release the Nucleus resources involved in error reporting from the Ethernet III controller software.
- Telnet Server and Excessive Error Reported
The Telnet server sometimes continued polling connections that was disconnecting, giving excessive reports like "Illegal socket ID".
- UDP-broadcasts Thrown Away
UDP-broadcasts was not handled correctly.
- ARP-entries are Kept for at Least Half an Hour
- The MBUFs Used by the RAW Protocol were Not Released.
- Nucleus Resources Not Released
The Nucleus resources used by the controller when an application used SLib to send data with the RAW protocol, were not released.
- Mixing TCP-port and UDP-port
Datagrams sent to local UDP-port number X would end up at local TCP-port number X if this did exist and had been created before the equally numbered UDP-port.
- The TCP/IP Data Checksum was Not Enabled and Bad Data were Accepted.
- The Heartbeat-check Mechanism Used to Check if the Ethernet III Controller is Active, Did Not Work.
- The Performance of Processes Using TCP/IP is Much Better.
- Some Error Reports from the Ethernet III Controller Software has been Improved, for Example the "Duplicated IP Addresses" Report Now Return Both the IP and Ethernet Addresses.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 39¶
Product Information¶
Date: 92.06.15
Page: 39 of 58
Product Name: Patch Kit for ND tpServer Platform (211560) version B
Product Number: 382300B
DMA-Server (250089C02)¶
Report no.
| no. | Title |
|---|---|
| 1 | Changing block size in MON ABSTR for BDIO disk. |
| 2 | Disable writing file mark and rewind on streamer. This was necessary to allow Backup Manager to copy images over more than one streamer. |
| 3 | Correction of calculation of pages copied when copying files with Backup System over more than one medium. |
| 4 | Improving timer mechanism and removing error message: "50010 - operation in progress" when starting BM-Filerestore. |
| 5 | Backup Manager image copies will sometimes fail at the end of the operation with the error message "50061 - Unknown Program Function" |
File Manager (211075C03)¶
no.
| no. | Title |
|---|---|
- When using File Manager version C, the User Environment profile database may increase even when no updates in the SIBAS/R database was necessary. This is now corrected. If the UE profile database has already grown too big because of this, you may use the program UE-D-SIP to delete obsolete information stored by File Manager, and then use the program UE-EX-VER-DXX executing functions Unload and Load to reduce the size of the profile database.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 40¶
Product Information¶
| Date | ND ServiceTeam | Page 40 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
ND-5830/5850 Microprogram (211847A01)¶
| no. | Title |
|---|---|
| - | Changed algorithm on TSET-cycles in the lock routine. While waiting for a semaphore, TSET was run every 2 microseconds. This is now changed to 50-microsecond intervals to avoid hang situations on the MF bus. |
| - | Changes timing in ENTS, ENTM, ENTF, ENTB to avoid a data cache hit on an instruction channel access when I-error. Previously, this led to inconsistency between cache and memory. |
| - | Corrections in the WEXT instruction adding a new Octobus driver. |
| - | Corrections in a wait for a semaphore, introducing a 13-second timeout. |
| - | Changes in the Octobus driver to release the execution queue if the microprogram has reserved the queue and the microprogram must wait more than 10 microseconds. This is done to avoid Lock timeout 20.328. |
| - | Corrected logical data memory read, function 10. This is now always run with paging on to allow for segment trace and multi-CPU. |
- ND-5800 Micro Program (211276E01)
- ND-5700 Micro Program (211275E01)
- ND-5500 Micro Program (211274E01)
- ND-5400 Micro Program (211273E01)
| no. | Title |
|---|---|
| - | Corrections in the AXI-instruction, which lost floating precision on the operation a**n (n < 0). The correction implies a changed order of operation: division prior to multiplication when a < 1 and division after multiplication when a > 1 |
| - | Corrections in a wait for a semaphore, introducing a 13-second timeout. |
| - | Changed the Octobus driver to release the execution queue if the microprogram has reserved the queue and the microprogram must wait more than 10 microseconds. This is done to avoid Lock timeout 20.328 and timeout 20008. |
| - | Corrections in CLREAD, NXGET and break. |
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 41¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 41 of 58
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
6 Errors Known But Not Corrected¶
-
SIBAS Manager (211455A06)
Report no. Title - - User statistics returns
<Unknown user name>if length of the User Environment user name is less than 8.
- User statistics returns
-
DMA-Server (250089C02)
Report no. Title - - Buffer allocation.
The DMA-server's transfer buffers may be placed in multiport memory by setting location 10₈ on DMASEG to 0.
The buffers may be placed in ND-100 memory by setting location 10₈ on DMASEG to 1.
The default value is 0. A prepared patch for changing it is included in the standard load file BACKUP-LOAD:MODE.
- Backup-system compatibility.
To allow restore of images written to streamer by Backup System location 11₈ on DMASEG should be set to 1.
Default value for this location is 0. A prepared patch for changing it is included in the standard load file BACKUP-LOAD:MODE.
- Buffer allocation.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 42¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 42 of 58
Product Information¶
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
Backup Manager for ND-500/5000 (211226B05)¶
| Report no. | Title |
|---|---|
- When Backup Manager creates a temporary mirror to perform an image copy of a directory on a DOMINO/SCSI disk, the error message 'NO MORE TO COPY' will be written on the error device when the backup procedure is finished. This message can be ignored!
Multi-Machine Operator Environment (211078A01)¶
| Report no. | Title |
|---|---|
| 3 | OE-STATU program will not work on machines with names longer than 12 characters |
User Environment (210518D07)¶
| Report no. | Title |
|---|---|
- Using 'Task-in-user-area' to start some products (e.g., NOTIS-WP) may cause the wrong user area to be present after the task is completed.
A workaround for this problem is to start NOTIS-WP with the option of clearing the scratch file:
@NOTIS-WP %<drawer>,<folder>,<document>
- When Stop-Terminal/Timeout happens and the user is in a UE-Menu, the UE Scratch file is not reset.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 43¶
Product Information¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
Special Modification Patches¶
Special Modification patches may now be installed while SINTRAN is running.
The installation is done as follows:
-
Edit the file
(SYSTEM)PF-MODIF-M:FADMso it contains the number(s) of the patch(es) you want to install (for example PN032). Ensure that the file is in 7-bit format. -
Run the program
(SPEC-MODIF-PATCH)SM-PATCHfrom user SYSTEM.
This program will install the right patches in SINTRAN save area.
During the installation you may get a warning, telling you that the patch is already installed, and a question if you want to reinstall the patch. Normally, you answer No to that question.
An exception is when you are going to install a new version of a patch. -
Run a cold start to get the patches into effect.
-
The files
(SYSTEM)SM-PATCH-FILE:OUTand(SYSTEM)SM-PATCHES:OUTare the output files from the SM-PATCH-program.
Inspect them if something goes wrong during the installation.
Page 44¶
Product Information¶
| Date | ND ServiceTeam | Page 44 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
8 Selecting Language Versions¶
The products SIBAS Manager and File Manager are available in both English and Norwegian. In both cases, language is set globally for all users of the system.
Similarly, the default language in User Environment can also be set globally. In User Environment, the default language only applies when the user name is not yet known (when logging in, etc.).
Furthermore, the SPRINT Spooling System is available in Danish as well as English and Norwegian.
The following procedures apply:
-
SIBAS Manager
Log in to user area SYSTEM and delete the SIBAS Manager as a standard domain.
Log in to user area SIBR-B and run one of the following mode files:
SM-LANG-EN:MODE (set language to English) SM-LANG-NO:MODE (set language to Norwegian)Log in to user area SYSTEM and define the SIBAS Manager as a standard domain again.
-
User Environment
Log in to user area USER-ENVIRONMENT and run one of the mode files:
UE-ENGLISH:MODE (set language to English) UE-NORWEGIAN:MODE (set language to Norwegian)Then run the mode file:
@MODE (USER-ENVIRONMENT)UE-LOAD,,,To set the language to Danish, you must acquire the language-dependent files for the Danish version of UE (diskette directory 21051BD07-DA-01D). Then copy all files except the files
IN-UE-DA-D07:****(3 files) andUE-DA-LAMU-D07:PROGto user area USER-ENVIRONMENT. When this is done, run the mode filesUE-DANISH:MODEand thenUE-LOAD:MODE.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 45¶
Product Information¶
| Date | ND ServiceTeam | Page 45 of 58 |
|---|---|---|
| 92.06.15 |
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
File Manager¶
Log in to user area ND-OPERATIONS and edit the file FM-LOAD:MODE:
File names should contain -EN (set language to English)
File names should contain -NO (set language to Norwegian)
Then run the mode file:
@MODE (ND-OPERATIONS)FM-LOAD,,,
SPRINT¶
To allow the use of Danish, you must log in to user area SPRINT and run the mode jobs:
@MODE SSY-DA,,,
@MODE LOAD-SPRINT,,,
@MODE START-SPRINT,,,
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 46¶
Product Information¶
| Date | ND ServiceTeam | Page 46 of 58 |
|---|---|---|
| 92.06.15 | PRODUCT INFORMATION |
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
9 General Information¶
Defining OpenLAN printers with a SINTRAN spooling queue in SPRINT.
-
Select a SINTRAN logical device number between 2300₈ and 2377₈ (1216 to 1279 decimal).
-
Connect the logical device number to the COSPO datafield:
Read the file SYMBOL-2-LIST:SYMB into an editor (for example PED) and find the symbol 'F1731'. Note the value of the symbol.
In a standard M-version the value (datafield address) is 074330.
Note
This address may be different in later version. You should therefore always verify the value of this address, because patching in the wrong address may cause serious damage to your system. -
Then execute the following commands:
@SINTRAN-SERVICE INSERT-IN-LOGICAL-UNIT-TABLE LOGICAL UNIT NUMBER (OCT): 23xx (use the device number you selected) INPUT OR OUTPUT? OUT DATAFIELD ADDRESS (OCT): 072162 (use the address you noted above) MEMORY? YES IMAGE? YES SAVE-AREA? YES EXIT -
Define the device number in the S3-CONFIG program and then perform a cold-start or use the command 'SET-SPOOLING-DEVICE' in the SINTRAN Service Program.
-
Define a peripheral file and spooling files in the usual way.
-
Stop COSMOS spooling by executing the command @ABORT COSPO
(Otherwise you will get the error message 'Device already defined' when defining the printer in SPRINT). -
Define the printer in AIP-HOST:SYMB and SPRINT.
-
Start COSMOS spooling: @START-SPOOLING COSMOS-SPOOLING
-
Stop and start SPRINT.
(Otherwise you will get the error message 'Not opened for sequential read' when printing via SINTRAN III).
If the printer is only to be used from NOTIS-WP version N or later or other applications with a direct SPRINT interface, you should skip all steps above except 6 and 8.
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 47¶
Product Information¶
Product Name¶
Patch Kit for ND tpServer Platform (211560) version B
Product Number¶
382300B
Files Replaced by This Patch Kit¶
- SINTRAN III/VSX-500 Standard System C (250306M06)
The file(s) have to be copied to user area SYSTEM:¶
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| * COLD-START-SEQ:MODE | 1 | R | R | RWACD |
| * SHORT-HENT:MODE | 3 | R | R | RWACD |
| * BEFORE-COPY:MODE | 12 | R | RWA | RWACD |
| * BM-OPERATOR-B05:DOM | 673 | R | RWA | RWACD |
| * BM-OPERAT-XX-B05:DOM | 156 | R | RWA | RWACD |
| LIST-IMPLEMENTED:PROG | 12 | R | R | RWACD |
| ER-S3WD-DESC-D06:EDAT | 40 | N | RWACD | RWACD |
| ER-S3WD-LOG-D03:PROG | 43 | R | R | RWACD |
| MON-CALL-1B-C01:BRF | 4 | R | R | RWACD |
| MON-CALL-2B-C01:BRF | 4 | R | R | RWACD |
| MON-CALL-LIB-C01:NRF | 6 | R | R | RWACD |
| MON-CALL-NAMES-C:DAT | 6 | R | R | RWACD |
| * READ-SEGMENT:MODE | 2 | R | R | RWACD |
| * REMOVE-FILES:MODE | 1 | R | R | RWACD |
| * PATCH-VERSION:MODE | 1 | R | R | RWACD |
| + MICRO-5830-10210:DATA | 144 | R | RWA | RWACD |
| S3-CONFIG-F01:PROG | 90 | R | R | RWA |
| SWAPPER-L04:PSEG | 23 | N | RWAC | RWACD |
| SWAPPER-L04:DSEG | 129 | N | RWAC | RWACD |
| PMA-SCSI-B010:IMAG | 249 | R | RWA | RWACD |
| GET-POOL-INFO:JOB | 7 | R | RWA | RWACD |
| GET-POOL-CONFIG:JOB | 11 | R | RWA | RWACD |
| * AFTER-COPY:MODE | 2 | R | RWA | RWACD |
| SINTRAN:DATA | 63 | N | N | RWACD |
| MACM-AREA:DATA | 64 | N | N | RWACD |
| + UE-ERMSG-EN-D14:NEW | 220 | R | RWACD | RWACD |
| PATCHLIST:OUT | 51 | N | RWACD | RWACD |
| PATCH-FILE:OUT | 8 | N | RWACD | RWACD |
| PMA-ETH3-TCIPNFS:IMAG | 164 | R | R | RWACD |
| LAST-FILE:LAST | 0 | R | RWA | RWACD |
| NOTS-SERVICE-D00:PROG | 48 | R | R | RWA |
| + MICRO-5800-B32:DATA | 128 | R | RWACD | RWACD |
| + UE-ERMSG-N0-D14:NEW | 221 | R | RWACD | RWACD |
| SOFTICE-A02:DOM | 172 | R | RWA | RWACD |
| + MICRO-7000-B32:DATA | 128 | RWACD | RWACD | RWACD |
| + MICRO-5850-10210:DATA | 144 | R | RWA | RWACD |
| + MICRO-5800-B32:DATA | 128 | RWACD | RWACD | RWACD |
| + MICRO-5400-B32:DATA | 128 | RWACD | RWACD | RWACD |
| SYMBOL-1-LIST:SYMB | 52 | N | RWACD | RWACD |
| SYMBOL-2-LIST:SYMB | 35 | N | RWACD | RWACD |
Files marked with a star (*) will be deleted after installation.
Files marked with a (+) must be deleted manually (@DELETE-FILE command).
Page 48¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page 48 of 58
Product Name¶
Patch Kit for ND tpServer Platform (211560) Version B
Product Number¶
382300B
- SPRINT Spooling System Version A (211056A06, 211583A06, 211495A06)
The file(s) have to be copied to user area SPRINT-USER:¶
| File Name | File Size | Public Access | Friend Access | Own Access |
|---|---|---|---|---|
| IN-PRM-AA-A06:DATA | 5 | R | RWA | RWACD |
| IN-PRM-AB-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AC-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AD-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AE-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AF-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AH-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AI-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AJ-A06:DATA | 2 | R | RWA | RWACD |
| IN-PRM-AK-A06:DATA | 1 | R | RWA | RWACD |
| IN-PRM-AL-A06:DATA | 1 | R | RWA | RWACD |
| IN-PRM-AP-A06:DATA | 1 | R | RWA | RWACD |
| IN-PRM-VI-A06:DATA | 1 | N | RWAD | RWACD |
| IN-PRM-A06:PROG | 80 | N | RWACD | RWACD |
| IN-PRM-A06:XCOM | 15 | R | RWACD | RWACD |
| IN-PRM-A06:INIT | 3 | N | RWACD | RWACD |
| SSY-SERVER-A06:PROG | 112 | R | RWA | RWACD |
| SSY-MAIN-A06:PROG | 128 | R | RWA | RWACD |
| SSY-SECO-A06:PROG | 78 | R | RWA | RWACD |
| SSY-PSHA-A06:PROG | 43 | R | RWA | RWACD |
| SSYLIB-1B-A06:BRF | 82 | R | RWA | RWACD |
| SSYLIB-2B-A06:BRF | 85 | R | RWA | RWACD |
| SSYLIB-500-A06:NRF | 84 | RWACD | RWACD | RWACD |
| SSYLIB-A06:DEFS | 2 | R | RWA | RWACD |
| SSYLIB-A06:H | 3 | R | RWA | RWACD |
| SSYLIB-A06:IMPT | 1 | R | RWA | RWACD |
| PRM-SERV-AA-A06:PFIL | 58 | R | RWA | RWACD |
| PRM-SERV-AA-A06:DFIL | 47 | R | RWA | RWACD |
| PRM-SERV-AB-A06:PFIL | 58 | R | RWA | RWACD |
| PRM-SERV-AB-A06:DFIL | 50 | R | RWA | RWACD |
| PRM-SERV-AC-A06:PFIL | 59 | R | RWA | RWACD |
| PRM-SERV-AC-A06:DFIL | 50 | R | RWA | RWACD |
| PRM-SERV-AD-A06:PFIL | 60 | R | RWA | RWACD |
| PRM-SERV-AD-A06:DFIL | 51 | R | RWA | RWACD |
| PRM-SERV-AE-A06:PFIL | 59 | R | RWA | RWACD |
| PRM-SERV-AE-A06:DFIL | 50 | R | RWA | RWACD |
| PRM-SERV-AF-A06:PFIL | 61 | R | RWA | RWACD |
| PRM-SERV-AF-A06:DFIL | 53 | R | RWA | RWACD |
| PRM-SERV-AH-A06:PFIL | 59 | R | RWA | RWACD |
| PRM-SERV-AH-A06:DFIL | 50 | R | RWA | RWACD |
| PRM-SERV-AI-A06:PFIL | 59 | R | RWA | RWACD |
| PRM-SERV-AI-A06:DFIL | 50 | R | RWA | RWACD |
| PRM-SERV-AJ-A06:PFIL | 56 | R | RWA | RWACD |
| PRM-SERV-AJ-A06:DFIL | 49 | R | RWA | RWACD |
| PRM-SERV-AK-A06:PFIL | 61 | R | RWA | RWACD |
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 49¶
Product Information¶
Product Name: Patch Kit for ND tpServer Platform (211560) version B
Product Number: 382300B
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| PRM-SERV-AK-A06:DFIL | 51 | R | RWA | RWACD |
| PRM-SERV-AL-A06:PFIL | 60 | R | RWA | RWACD |
| PRM-SERV-AL-A06:DFIL | 50 | R | RWA | RWACD |
| PRM-SERV-AP-A06:PFIL | 59 | R | RWA | RWACD |
| PRM-SERV-AP-A06:DFIL | 50 | R | RWA | RWACD |
| VISI-SERVER-A06:PROG | 83 | R | RWA | RWACD |
| SETUP-ND708-A06:SYMB | 19 | R | RWA | RWACD |
| SETUP-CANON-C06:SYMB | 27 | R | RWA | RWACD |
| SETUP-CANON-D01:SYMB | 41 | R | RWA | RWACD |
| SSY-UTILITY-A06:PROG | 100 | R | R | RWACD |
| SSY-UTILITY-A06:HELP | 1 | N | R | RWACD |
| SSY-SET-CPU-N0:PROG | 6 | R | RWA | RWACD |
| SSY-PICT-EN-A06:NDPF | 35 | R | RWA | RWACD |
| SSY-PICT-EN-A06:CONF | 21 | R | RWA | RWACD |
| SSY-PICT-NO-A06:NDPF | 34 | R | RWA | RWACD |
| SSY-PICT-NO-A06:CONF | 21 | R | RWA | RWACD |
| SSY-PICT-DA-A06:CONF | 22 | R | RWA | RWACD |
| SSY-PICT-DA-A06:NDPF | 36 | R | RWA | RWACD |
| SSY-DA:MODE | 1 | N | RWACD | RWACD |
The file(s) have to be copied to user area ND-OPERATIONS:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| START-SPRINT:MODE | 1 | N | RWA | RWACD |
Instructions¶
!! Do NOT restart a printer from SPRINT (without investigating first) !!
If a printer gives an error message in SPRINT, check the printer itself.
If no reason for the problem is evident, you may restart the printer.
Unnecessary starting of printers will 'jam' SPRINT, and you may end up with the message 'Sprint is busy'.
Note that OpenLAN printers may sometimes give 'misleading' error messages. If a printer stops due to paper crash or empty input-bin during a printout, the connection will stay open and give one of the messages 'Printer is occupied. Waiting for access' or 'Impossible to send data to printer' when printing from another system. These messages may then also mean paper crash if they do not disappear within reasonable time.
ALWAYS check the printer itself before you do anything else.
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 50¶
Product Information¶
| Date | ND ServiceTeam | Page 50 of 58 |
|---|---|---|
| Product name | Product number | |
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
- SIBAS /R version B (211304B06)
The file(s) have to be copied to user area SIBR-B:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SM-SERVER-AO6:DOM | 288 | R | R | RWACD |
| SM-TRMH-AO6:DOM | 36 | R | R | RWACD |
| SM-TRMH-DATA-AO6:SEG | 5 | R | R | RWACD |
| SM-SIBLINK-AO6:MODE | 1 | R | R | RWACD |
| SM-LOAD-AO6:MODE | 1 | R | R | RWACD |
| SM-TRMH-LIBR-AO6:NRF | 1 | R | R | RWACD |
| SM-OPERATOR-AO6:DOM | 326 | R | R | RWACD |
| SM-TEXT-EN-AO6:ERR | 6 | R | R | RWACD |
| SM-TEXT-NO-AO6:ERR | 6 | R | R | RWACD |
| SM-OPER-EN-AO6:SEG | 133 | R | R | RWACD |
| SM-OPER-XX-AO6:SEG | 133 | R | R | RWACD |
| SM-OPER-NO-AO6:SEG | 133 | R | R | RWACD |
| SM-LANG-EN-AO6:MODE | 1 | R | R | RWACD |
| SM-LANG-NO-AO6:MODE | 1 | R | R | RWACD |
| SM-START-AO6:MODE | 1 | R | N | RWACD |
| SIBAS:DUMP | 0 | RWACD | RWACD | RWACD |
| SIBR-DBC-AO8:PROG | 95 | R | R | RWACD |
| SIBRP-BO6:SEG | 338 | R | RWACD | RWACD |
| SIBR-LIBRARY-BO6:ENTR | 14 | R | RWACD | RWACD |
| SIBR-FAST-BO6:SEG | 129 | R | RWACD | RWACD |
| SIBRP-USTAB-BO6:SEG | 3 | R | RWACD | RWACD |
| SIB1LB-BO6:IMPT | 17 | R | RWACD | RWACD |
| SIBR-LIB-1B-BO6:BRF | 31 | R | RWA | RWACD |
| SIBR-LIB-2B-BO6:BRF | 31 | R | RWA | RWACD |
| SIBR-LIB-N-BO6:NRF | 396 | R | RWACD | RWACD |
| SIBRP-COMMON-BO6:SEG | 17 | R | RWACD | RWACD |
| SW-CONFIG:SYMB | 23 | R | RWACD | RWACD |
| SIBRC-BO6:OUT | 1 | R | RWACD | RWACD |
| SIBRC-BO6:ENTR | 2 | R | RWACD | RWACD |
| SIBRC-BO6:PROG | 125 | R | RWACD | RWACD |
| SIBRC-UTIL-BO6:PROG | 52 | R | RWACD | RWACD |
| SIBRC-BO6:DUMP | 1 | R | RWACD | RWACD |
| SIBCOM-MONIT-BO6:DOM | 95 | R | RWACD | RWACD |
| SIBR-INTR-EN-BO6:ERR | 6 | R | RWACD | RWACD |
| SIBR-M-SERV-BO6:PROG | 74 | R | RWACD | RWACD |
| SIBR-LIBRARY-BO6:SEG | 113 | R | RWACD | RWACD |
| SIBR-INTER-BO6:DOM | 178 | R | RWACD | RWACD |
| SIBRP-500-BO6:ENTR | 22 | R | RWACD | RWACD |
| FAST-VERIFY:MCRO | 2 | R | RWACD | RWACD |
| SIB1LB-MSG-GEN:DOM | 49 | R | RWACD | RWACD |
| SIBRP-CURBUL-BO6:SEG | 3 | R | RWACD | RWACD |
| SIBRP-DUMMY-BO6:SEG | 3 | R | RWACD | RWACD |
| SIBRP-IOBUF-BO6:SEG | 3 | R | RWACD | RWACD |
| SIBRP-SIFT-C:SEG | 4 | R | RWACD | RWACD |
ND-896058 EN 2
[Scanned by Jonny Odden for Sintran Data © 2022]
Page 51¶
Product Information¶
Patch Kit for ND tpServer Platform (211560) Version B¶
Product Number: 382300B
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SIBR-DBM-COM-B06:SEG | 9 | R | RHWACD | RHWACD |
| SIBRP-NUCL:NRF | 3 | R | RHWACD | RHWACD |
| SIBRP-B06:DOM | 2 | R | RHWACD | RHWACD |
| SIBR-DBM-B06:DOM | 628 | R | RHWACD | RHWACD |
| SIBRS-B06:ENTR | 6 | R | RHWACD | RHWACD |
| SIBR-DRL-COM-B06:SEG | 8 | R | RHWACD | RHWACD |
| SIBR-DRL-B06:DOM | 251 | R | RHWACD | RHWACD |
| SIBR-DBM-SYN-B06:OBJ | 37 | R | RHWACD | RHWACD |
| SIBR-DBM-B06:ENTR | 35 | R | RHWACD | RHWACD |
| DRL-SORTTAB-B06:DOM | 15 | R | RHWACD | RHWACD |
| SIBR-SERVICE-B06:ENTR | 18 | R | RHWACD | RHWACD |
| SIBR-DBC-B06:SEG | 8 | R | RHWACD | RHWACD |
| SIBR-FAST-B06:DOM | 17 | R | RHWACD | RHWACD |
| SIBR-DRL-B06:ENTR | 20 | R | RHWACD | RHWACD |
| SIBR-LOOKLOG-B06:PROG | 71 | R | RHWACD | RHWACD |
| SIBR-DPA-B06:PROG | 44 | R | RHWACD | RHWACD |
| SIBR-DBC-B06:DOM | 138 | R | RHWACD | RHWACD |
| SIBR-SERVICE-B06:DOM | 257 | R | RHWACD | RHWACD |
| SIBR-LGAMSA-B06:DATA | 33 | R | RHWACD | RHWACD |
| SIBRP-SQL-B06:SEG | 560 | R | RHWACD | RHWACD |
| SIBR-DEBUG-00:SYMB | 2 | R | RHWACD | RHWACD |
| SIBRR-B06:PROG | 76 | R | RHWACD | RHWACD |
| SIBCOM-START-B06:MODE | 1 | R | RHWACD | RHWACD |
| SIBCOM-LOAD-B06:MODE | 1 | R | RHWACD | RHWACD |
| SIBRS-B06:DOM | 96 | R | RHWACD | RHWACD |
DOMINO Maintenance Kit Version D (211322D02)¶
The file(s) have to be copied to user area TEST-USER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| DISK-MM-TP-D02:TEST | 38 | R | RWA | RHWACD |
| DISK-MME1T-D02:NEXT | 11 | R | RWA | RHWACD |
| DISK-MME2T-D02:NEXT | 11 | R | RWA | RHWACD |
| DISK-MMC1T-D02:NEXT | 6 | R | RWA | RHWACD |
| DISK-MMC2T-D02:NEXT | 6 | R | RWA | RHWACD |
| DISK-MMC3T-D02:NEXT | 6 | R | RWA | RHWACD |
| DISK-MMC4T-D02:NEXT | 6 | R | RWA | RHWACD |
| DISK-MMC5T-D02:NEXT | 6 | R | RWA | RHWACD |
| DISK-MMC6T-D02:NEXT | 6 | R | RWA | RHWACD |
Page 52¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page 52 of 58
Product name
Patch Kit for ND tpServer Platform (211560) version B
Product number
382300B
- User-Environment version D (210518D07):
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| UE-PMAN-EN-D07:NDPF | 34 | R | RWACD | RWACD |
| UE-PMAN-EN-D07:CONF | 30 | R | RWACD | RWACD |
| UE-HIERAR-EN-D07:MENU | 23 | R | RWACD | RWACD |
| UE-LOGIN-EN-D07:CONF | 8 | R | RWACD | RWACD |
| UE-FUNC-EN-D07:NDPF | 26 | R | RWACD | RWACD |
| UE-FUNC-EN-D07:CONF | 14 | R | RWACD | RWACD |
| UE-STDHIE-EN-D07:NDPF | 17 | R | RWACD | RWACD |
| UE-STDHIE-EN-D07:CONF | 8 | R | RWACD | RWACD |
| UE-PMAN-NO-D07:NDPF | 35 | R | RWACD | RWACD |
| UE-CH-LAMUD-07:PROG | 4 | R | RWACD | RWACD |
| UE-ME-EN-D07:NDPF | 32 | R | RWACD | RWACD |
| UE-ME-EN-D07:CONF | 15 | R | RWACD | RWACD |
| UE-ACTIV-EN-D07:RPRT | 10 | R | RWACD | RWACD |
| UE-PMAN-NO-D07:CONF | 30 | R | RWACD | RWACD |
| UE-LOGIN-NO-D07:CONF | 8 | R | RWACD | RWACD |
| UE-ME-NO-D07:NDPF | 31 | R | RWACD | RWACD |
| UE-ME-NO-D07:CONF | 15 | R | RWACD | RWACD |
| UE-FUNC-NO-D07:NDPF | 27 | R | RWACD | RWACD |
| UE-FUNC-NO-D07:CONF | 14 | R | RWACD | RWACD |
| UE-STDHIE-NO-D07:NDPF | 17 | R | RWACD | RWACD |
| UE-STDHIE-NO-D07:CONF | 8 | R | RWACD | RWACD |
| UE-ACTIV-NO-D07:RPRT | 10 | R | RWACD | RWACD |
| UE-HIERAR-NO-D07:MENU | 24 | R | RWACD | RWACD |
| UE-RSTAT-NO-D07:TEXT | 6 | R | RWACD | RWACD |
| UE-RSTAT-EN-D07:TEXT | 6 | R | RWACD | RWACD |
| UE-PLIB-P1-D07:BRF | 66 | R | RWAC | RWACD |
| UE-PSER-DUMP-D07:MODE | 1 | R | RWACD | RWACD |
| NDP-COMPILER-E:PROG | 35 | R | RWACD | RWACD |
| UE-ST-LAMU-D07:PROG | 3 | R | RWACD | RWACD |
| UE-PLIB-D1-D07:BRF | 3 | R | RWAC | RWACD |
| UE-PLIB-P2-D07:BRF | 69 | R | RWAC | RWACD |
| UE-PLIB-D2-D07:BRF | 3 | R | RWAC | RWACD |
| UE-PLIB-P5-D07:NRF | 66 | R | RWAC | RWACD |
| UE-PLIB-D5-D07:NRF | 3 | R | RWAC | RWACD |
| UE-PLIBTEST-D07:PROG | 98 | R | RWACD | RWACD |
| UE-PLIB-D07:IMPT | 4 | R | RWACD | RWACD |
| UE-PLIB-D07:DEFS | 8 | R | RWACD | RWACD |
| UE-PSER-MAIN-D07:PROG | 81 | R | RWACD | RWACD |
| UE-PSER-BASE-D07:PROG | 75 | R | RWACD | RWACD |
| UE-PSER-DATA-D07:PROG | 46 | R | RWACD | RWACD |
| UE-DB-CONV-D07:PROG | 82 | R | RWACD | RWACD |
| UE-LOGIN-D07:PROG | 82 | R | RWACD | RWACD |
| UE-MEMAIN-D07:PROG | 125 | R | RWACD | RWACD |
| UE-MENU-D07:PROG | 1 | R | RWACD | RWACD |
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 53¶
Product Information¶
Product name
Patch Kit for ND tpServer Platform (211560) version B
Product number
382300B
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| UE-MEUTIL-D07:PROG | 78 | R | RWACD | RWACD |
| UE-RUN-D07:PROG | 127 | R | RWACD | RWACD |
| UE-EX-VER-D07:PROG | 88 | R | RWACD | RWACD |
| UE-PMAN-MAIN-D07:PROG | 117 | R | RWACD | RWACD |
| UE-PMAN-EXT1-D07:PROG | 76 | R | RWACD | RWACD |
| UE-PMAN-EXT2-D07:PROG | 46 | R | RWACD | RWACD |
| UE-FUNC-MAIN-D07:PROG | 113 | R | RWACD | RWACD |
| UE-FUNC-EXT-D07:PROG | 69 | R | RWACD | RWACD |
| UE-LOAD:MODE | 1 | R | RWACD | RWACD |
| UE-CHCPU-D07:PROG | 96 | R | RWACD | RWACD |
| WAIT-FOR-UE-D07:PROG | 16 | R | RWACD | RWACD |
| UE-PATCH-D07:MODE | 2 | R | RWACD | RWACD |
| UE-TP-PATCH-D07:MODE | 1 | R | RWACD | RWACD |
| UE-D-SIP-D07:PROG | 77 | N | RWACD | RWACD |
| UE-NORWEGIAN:MODE | 1 | R | RWACD | RWACD |
| UE-ENGLISH:MODE | 1 | R | RWACD | RWACD |
| UE-DANISH:MODE | 1 | R | RWACD | RWACD |
Every terminal using the menu system uses ONE System LAMU.
- Backup Manager for ND ND-500/5000 version B (211226B05)
The file(s) have to be copied to user area BACKUP-MANAGER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| BM-OPERATOR-B05:DOM | 702 | R | RHACD | RWACD |
| BM-FILERESTO-B05:DOM | 517 | R | RWACD | RWACD |
| BM-SCHEDULER-B05:DOM | 177 | R | RWACD | RWACD |
| BM-DEFINITION-B05:DOM | 342 | R | RWACD | RWACD |
| BM-SERVER-B05:MODE | 1 | N | RWACD | RWACD |
| BM-DUMP-B05:MODE | 1 | N | RWACD | RWACD |
| BM-START-B05:MODE | 1 | N | RWACD | RWACD |
| BM-SERVER-B05:PROG | 105 | N | RWACD | RWACD |
| BM-DEFINI-XX-B05:SEG | 108 | R | RWACD | RWACD |
| BM-OPERAT-XX-B05:SEG | 156 | R | RWACD | RWACD |
| BM-FILERE-XX-B05:SEG | 68 | R | RWACD | RWACD |
| BM-SCHED-XX-B05:SEG | 108 | R | RWACD | RWACD |
The file(s) have to be copied to user area ND-OPERATIONS:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| BM-FILERE-PARA:DATA | 1 | R | RWACD | RWACD |
ND-896058 EN 2
[Scanned by Jonny Odden for Sintran Data © 2022]
Page 54¶
Product Information¶
Date: 92.06.15
Page: 54 of 58
ND ServiceTeam
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
NOTIS-DS for ND-500/5000 version E (210794E04)¶
The file(s) have to be copied to user area DS-PROGRAMS:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| NOTIS-DS-NO-E04:DOM | 343 | R | RWACD | RWACD |
| NOTIS-DS-NO-E04:SEG | 180 | R | RWACD | RWACD |
| DS-DSERVER-E04:DOM | 576 | R | R | RWACD |
| DS-INITDB-E04:DOM | 90 | R | R | RWACD |
| DS-ACCOUNT-E04:DOM | 155 | R | R | RWACD |
| DS-CONVERT-E04:DOM | 236 | R | R | RWACD |
| DS-CONVERT-E04:SEG | 122 | R | R | RWACD |
| DS-EMSTART-E04:MODE | 1 | R | RWACD | RWACD |
| DS-EMSTOP-E04:MODE | 1 | R | RWACD | RWACD |
| DS-EMSERVICE-E04:PROG | 41 | R | R | RWACD |
| DS-EM-500-E04:PROG | 24 | R | R | RWACD |
| DS-EM-LOAD-E04:MODE | 1 | R | RWACD | RWACD |
| NOTIS-DS-EN-E04:DATA | 62 | R | RWACD | RWACD |
| NOTIS-DS-E04:MODE | 1 | R | RWACD | RWACD |
| DS-DOCREC-E04:SEG | 178 | R | RWACD | RWACD |
| DS-DSERVER-E04:MODE | 1 | R | RWACD | RWACD |
| DS-DOCREC-E04:DOM | 598 | R | RWACD | RWACD |
| DS-INITDB-E04:MODE | 1 | R | RWACD | RWACD |
| DS-ACCOUNT-E04:MODE | 1 | R | RWACD | RWACD |
| DS-CONVERT-E04:MODE | 1 | R | RWACD | RWACD |
| DS-MAKE-DB-E04:MODE | 1 | R | RWACD | RWACD |
| REDEF-IX:MODE | 1 | R | RWACD | RWACD |
| REDEF-IX-DSBASE:DRL | 1 | R | RWACD | RWACD |
| DS-DEFINE-E04:DOM | 107 | R | R | RWACD |
| DS-DEFINE-E04:DRL | 4 | R | RWACD | RWACD |
SPEC-MODIF-PATCH:¶
The file(s) have to be copied to user area SPEC-MODIF-PATCH:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SM-PF-LIBR-7400:FADM | 1 | R | RWACD | RWACD |
| SM-SYMBOLS-7400:FADM | 1 | R | RWACD | RWACD |
| SM-REFEREN-7400:FADM | 1 | R | RWACD | RWACD |
| SM-PATCHES-7400:PATC | 11 | R | RWACD | RWACD |
| SM-PATCH-007400:SEL | 5 | R | RWACD | RWACD |
| SM-PATCH:PROG | 21 | R | RWACD | RWACD |
| SM-START-PA-FILE:MODE | 1 | R | RWACD | RWACD |
| SM-PATCH-FILE:MODE | 3 | R | RWACD | RWACD |
ND-896058 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2022]
Page 55¶
Product Information¶
Date: 92.06.15
Service Team: ND ServiceTeam
Page: 55 of 58
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
Multi-Machine Operator Environment (211078A01)¶
The file(s) have to be copied to user area OE-USER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| DOMI-MONITOR-14D:DOM | 272 | R | RWACD | RWACD |
| FM-SIN-EN-C03:PROG | 86 | R | RWACD | RWACD |
| DOMI-MAILBOX-14D:SEG | 12 | R | R | RWACD |
| OEM-STATU-A01:DOM | 441 | R | RWACD | RWACD |
| FM-SIN-NO-C03:PROG | 86 | R | RWACD | RWACD |
| OE-LOAD:MODE | 1 | N | RWACD | RWACD |
| FILE-MAN-EN-C03:PROG | 118 | R | RWACD | RWACD |
| FILE-MAN-NO-C03:PROG | 118 | R | RWACD | RWACD |
| FM-PICS-NO-C03:NDPF | 63 | R | RWACD | RWACD |
| FM-PICS-EN-C03:NDPF | 62 | R | RWACD | RWACD |
| TCPIP-MONIT-D00:PROG | 84 | R | RWA | RWACD |
| NK-MON-C05:DOM | 104 | R | RWACD | RWACD |
TCP/IP Basic Module III version D (211327D00)¶
The file(s) have to be copied to user area TCP-IP:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| FTPRT-D00:PROG | 26 | N | R | RWACD |
| FTP-SERV-BA-B05:PROG | 96 | N | RWACD | RWACD |
| REBOOT-SLOT-D00:PROG | 11 | N | R | RWACD |
| STOP-SLOT-D00:PROG | 11 | N | R | RWACD |
| DEFINE-TCPD-D00:MODE | 1 | N | R | RWACD |
| DEFINE-FTPRT-D00:MODE | 1 | N | R | RWACD |
| TCPD-D00:PROG | 53 | N | R | RWACD |
| TCP-BA-LOAD-D00:MODE | 1 | N | RWACD | RWACD |
| TCP-BA-REBO-B:MODE | 1 | N | RWACD | RWACD |
| TCP-BA-STOP-B:MODE | 1 | N | RWACD | RWACD |
| FTP-CLIENT-D01:PROG | 62 | N | RWACD | RWACD |
| TELNET-CLIEN-D01:PROG | 53 | N | RWACD | RWACD |
Page 56¶
Product Information¶
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
SINTRAN III/VSX Version M, Revision 7400 (250306M06 + 250360M09)¶
The file(s) have to be copied to user area RT:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| S3SFSEGMENT:BPUN | 54 | R | R | RWACD |
| S3SCPSGEMENT:BPUN | 54 | R | R | RWACD |
| S3SRPITSEGMENT:BPUN | 52 | R | R | RWACD |
| S3SMIPSSEGMENT:BPUN | 52 | R | R | RWACD |
| S3SGSTSEGMENT:BPUN | 17 | R | R | RWACD |
| S3SPPSSEGMENT:BPUN | 2 | R | R | RWACD |
| S3SDPITSEGMENT:BPUN | 6 | R | R | RWACD |
| S3SDITSEGMENT:BPUN | 46 | R | R | RWACD |
| S3SYSYSEGMENT:BPUN | 4 | R | R | RWACD |
| S3SECOSEGMENT:BPUN | 3 | R | R | RWACD |
| S3SMPSSEGMENT:BPUN | 49 | R | R | RWACD |
| S3SPIITSEGMENT:BPUN | 52 | R | R | RWACD |
| S3SMSESEGMENT:BPUN | 37 | R | R | RWACD |
| S3SDWSEGMENT:BPUN | 5 | R | R | RWACD |
| S3SXRMKSEGMENT:BPUN | 32 | R | R | RWACD |
| S3SXROUSEGMENT:BPUN | 34 | R | R | RWACD |
| S3SDNAMSEGMENT:BPUN | 7 | R | R | RWACD |
| S3SXMFISEGMENT:BPUN | 55 | R | R | RWACD |
| S3SNKSEGSEGMENT:BPUN | 53 | R | R | RWACD |
| S3SNKNASEGMENT:BPUN | 65 | R | R | RWACD |
| S3SUI10SEGMENT:BPUN | 33 | R | R | RWACD |
| S3SUI20SEGMENT:BPUN | 33 | R | R | RWACD |
| S3SERWSEGMENT:BPUN | 53 | R | R | RWACD |
| S3SERWDSEGMENT:BPUN | 57 | R | R | RWACD |
| S3SPRMASEGMENT:BPUN | 53 | R | R | RWACD |
| S3SPWRSEGMENT:BPUN | 53 | R | R | RWACD |
| S3SBOPCSEGMENT:BPUN | 53 | R | R | RWACD |
| S3SMTSESEGMENT:BPUN | 5 | R | R | RWACD |
These files will be deleted after installation.
NUCLEUS Maintenance Kit Version C (211321C03)¶
The file(s) have to be copied to user area TEST-USER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| NKS5000-C03:DOM | 96 | R | RWACD | RWACD |
| DEVICE-TEST:DOM | 764 | R | RWACD | RWACD |
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 57¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 57 of 58
Product Details¶
| Product name | Product number |
|---|---|
| Patch Kit for ND tpServer Platform (211560) version B | 382300B |
DSS Test Programs version D (211481D01)¶
The file(s) have to be copied to user area TEST-USER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SCSI-TV-TP-D01:TEST | 37 | R | RWA | RWA CD |
| SCSI-TVEOT-D01:NEXT | 11 | R | RWA | RWA CD |
| SCSI-TVE2T-D01:NEXT | 11 | R | RWA | RWA CD |
| SCSI-TVC1T-D01:NEXT | 14 | R | RWA | RWA CD |
| SCSI-TVD0T-D01:NEXT | 14 | R | RWA | RWA CD |
| SCSI-TVD1T-D01:NEXT | 14 | R | RWA | RWA CD |
| SCSI-TVD2T-D01:NEXT | 14 | R | RWA | RWA CD |
| SCSI-TVD3T-D01:NEXT | 14 | R | RWA | RWA CD |
DSS Basic System version A (211479A09)¶
The file(s) have to be copied to user area SCSI-DOMINO:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| BDIO:DOM | 249 | N | RHACD | RHACD |
| STORAGE-ADMIN:DOM | 160 | R | RHACD | RHACD |
OWS Access Server for ND-5000 version B (211325B04)¶
The file(s) have to be copied to user area OPENLAN:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| OWSACCSERV-B04:DOM | 116 | RWACD | RWACD | RWACD |
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022
Page 58¶
Product Information¶
Date: 92.06.15
ND ServiceTeam
Page: 58 of 58
Product name: Patch Kit for ND tpServer Platform (211560) version B
Product number: 382300B
ND-500/5000 System Package for SINTRAN III version M version C (211305C04)¶
The file(s) have to be copied to user area BASIC-FILES:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| ND-500-MON-K02:PROG | 154 | R | R | RWA |
Backup System version I (210337I06)¶
The file(s) have to be copied to user area BASIC-FILES:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| BACKUP-LOAD-I:MODE | 2 | R | RWACD | RWACD |
| BACKUP-SERV-I06:PROG | 59 | R | RWACD | RWACD |
PED for ND-500/5000 (English) version K (210532K)¶
The file(s) have to be copied to user area BASIC-FILES:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| PED-500-ENG-K:DOM | 114 | R | RWA | RWACD |
File System Verification version A (211073B00)¶
The file(s) have to be copied to user area OE-USER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| OEV-VERIF-BOO:DOM | 274 | R | RWA | RWACD |
| OEV-VERIF-EN-BOO:DATA | 56 | R | RWA | RWACD |
| OEV-VERIF-NO-BOO:DATA | 56 | R | RWA | RWACD |
ND-896058 EN 2
Scanned by Jonny Oddene for Sintran Data © 2022