Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| PC-NOTIS Platform | 230142A |
Description of Product¶
This product is the basic program for the PC-NOTIS product family. It contains a menu program, a terminal emulator, a program which connects NOTIS applications running in PC with those in ND-500/5000 and support programs.
Floppy 230142A01-NO-01D - 5 1/4" or 30142N01A01 - 3 1/2"
contains the installation program for the menu system, the terminal emulator, the application starter for PC programs, examples of log in and out script files and utility programs.
Documentation:
| PC-NOTIS Brukerhåndbok | 863072.1 NO |
| PC-NOTIS Driftshåndbok | 863073.1 NO |
Reason(s) for New Product or Version¶
+--------------------------------------------------------------+
| PC-NOTIS Platform makes it possible with full integration |
| between NOTIS products running in the PC and in the ND-500(0).|
| With PC-NOTIS Platform applications can be strated on the ND |
| Host from either the Menu system directly or from applications|
| running in the PC. |
+--------------------------------------------------------------+
Table of Contents¶
| PAGE | |
|---|---|
| Prerequisites | 2 |
| Dependencies | 4 |
| Documentation | 5 |
| Installation procedure | 6 |
| Modifications | 7 |
| Errors corrected | 7 |
| Errors known but not corrected | 7 |
ND-895533.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 2¶
Product Information¶
Product name
PC-NOTIS Platform
Product number
230142A
1 Prerequisites¶
In order to use this product, the following is required.
1.1 Hardware Prerequisites¶
PC/OWS computer type (any of the following):
- Office Workstation OWS-12/55/85
- ND PC 286/386
or compatible
PC/OWS other hardware:
| Product name | Product number |
|---|---|
| OWS Terminal Line Adaptor | 110385 |
| or OWS OpenLAN Adaptor/Ethernet | 110386 |
| or OWS OpenLAN Adaptor/Cheapernet | 110394 |
| or Ethernet Adaptor/PC | 110683 |
| or Ethernet Adaptor/MC | 110758 |
Host computer type:
- ND-500/5000
ND-500/5000 other hardware:
| Product name | Product number |
|---|---|
| Ethernet II Controller | 110683 |
| Ethernet III Controller | 110513 |
ND-895533.1 EN
Page 3¶
Product Information¶
| Product name | Product number |
|---|---|
| PC-NOTIS Platform | 230142A |
1.2 Software Prerequisites¶
The following software must be available on the system before the product can be installed:
PC/OWS Operating System¶
| Name | Version/Revision |
|---|---|
| OWS-12 | MS-DOS 3.10 or higher |
| OWS-55 and -85 | MS-DOS 3.21 or higher |
| ND PC 286/386 line | MS-DOS 3.3 or higher |
PC/OWS Other Software¶
| Product name | Product number |
|---|---|
| ND PC Starter Kit A01 or newer | 230123 |
| For Ethernet: PC ET Communication | 230033 |
ND-500/5000 Operating System¶
| Name | Version/Revision |
|---|---|
| SINTRAN III | K or newer |
ND-500/5000 Other Software¶
| Product name | Product number |
|---|---|
| PC-NOTIS Server | 230143 |
| OWS Terminal Server B00 or newer | 211295 |
| or OWS Access Server | 211297 |
1.3 Other Prerequisites¶
- High memory: Not required, but a diskcache in high memory gives better performance
- Base memory: 640 KB
- Disk space: 600 KB
- Requires ND keyboard (Y/N): Yes
- Drivers/TSRs: VKM Keyboard Manager (installed by PC Starter Kit) CONNECT (installed by PC Starter Kit or Ethernet installation floppy).
ND-895533.1 EN
Page 4¶
Product Information¶
| Product name | PC-NOTIS Platform |
| Product number | 230142A |
2 Dependencies¶
The included terminal emulator is based on the SLINK terminal emulator and is thus using parts of the SLINK package. PC-NOTIS Platform will install needed software if SLINK is not previously installed. If SLINK is installed after the PC-NOTIS Platform, it will overwrite the software that PC-NOTIS Platform has installed. (This is mainly screen colours - entries that start with EMUL-E- in NDCONFIG - and the HELP-files TERMINAL.STR, TERMINAL.HLP and VKM.HLP.)
2.1 Hardware Dependencies¶
None.
2.2 Software Dependencies¶
| Product name | Product number |
|---|---|
| NOTIS-WP for ND-500/5000 | 210526 >=001 |
Nature of dependency
To start NOTIS-TF from the PC, or to start applications on the PC from NOTIS-WP (HOST), you need WP 001 or newer.
2.3 Other Dependencies¶
You should also be aware of the following dependencies:
| Product name | Product number |
|---|---|
| NOTIS-ID for ND-500/5000 | 210792 >=B10 |
| NOTIS-DS for ND-500/5000 | 210794 >=D05 |
| NOTIS-CALC for ND-500/5000 | 210716 >=E04 |
Nature of dependency
To start NOTIS applications on the PC from these programs on the ND-HOST you need these versions or newer.
ND-895533.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 5¶
Product Information¶
Product name:
PC-NOTIS Platform
Product number:
230142A
3 Documentation¶
Included with the product¶
| Title | Number |
|---|---|
| PC-NOTIS Brukerhåndbok | 863072.1 NO |
| PC-NOTIS Driftshåndbok | 863073.1 NO |
Optional (must be purchased)¶
| Title | Number |
|---|---|
| NOTIS-WP Brukerveiledning | 860318.3A NO |
| NOTIS-WP Kort Introduksjon | 863055.2 NO |
| NOTIS-WP Referansehåndbok | 863002.3 NO |
| NOTIS-CALC Brukerhåndbok | 863025.4 NO |
| NOTIS-CALC Oppslagskort | 899012.1 NO |
| NOTIS-DS Brukerveiledning | 863017.3 NO |
| NOTIS-DS Driftshåndbok | 830059.4 NO |
| NOTIS-ID Brukerveiledning | 863011.2 NO |
| NOTIS-ID Driftshåndbok | 830062.1 NO |
ND-895533.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 6¶
Product Information¶
| Product name | Product number |
|---|---|
| PC-NOTIS Platform | 230142A |
4 Installation Procedure¶
4.1 Automatic Installation¶
To install PC-NOTIS Platform, please insert the floppy in diskette drive A: on your PC, and type
A:INSTALL↵
The installation job will guide you through a complete installation of PC-NOTIS Platform.
4.2 Non-Automatic Installation¶
Not recommended.
4.3 Automatic PC-NOTIS Starting¶
If you want to have automatic start of PC-NOTIS when booting the PC the following line must be added to AUTOEXEC.BAT:
C:\ND-OWS\NOTIS.BAT
This will only take effect after a reboot.
4.4 Starting PC-NOTIS¶
If you have chosen to start PC-NOTIS manually every time it’s needed give the following commands:
- Change to subdirectory ND-OWS (Not necessary if ND-OWS is part of the defined path in AUTOEXEC.BAT).
- Give the start-command: NOTIS.
4.5 PC-NOTIS on Monochrome Monitor¶
When running PC-NOTIS on monochrome monitors the colour settings should be changed to give a better result in black and white. This could easily be done by running a batch-job:
C:\ND-OWS\SETMONO.BAT
ND-895533.1 EN
Page 7¶
____________ ________________________
| ND | | PRODUCT INFORMATION |
| NORSK | | Product name |
| DATA | | PC-NOTIS Platform |
|____________| |________________________|
| Product number |
| 230142A |
|_________________________|
5 Modifications¶
None. This is a new product.
6 Errors Corrected¶
None.
7 Errors Known But Not Corrected¶
During installation it might happen you will get an error message: "Out of environment space". The size of the environmental space is defined in the CONFIG.SYS file. See the MS-DOS manual for details.
During installation you might get an error message:
"Cannot find match for
- Copy NDCONFIG.EXE from PC Starter Kit floppy no. 2 to the directory C:\ND-OWS\MAINT.
- Copy NDCONFIG.SAx (if more .SAx'es, choose the one with the highest number) from directory C:\ND-OWS to a new file NDCONFIG (without any extension).
- Start installation all over again.
The PC-NOTIS menu system will not run if you have installed the DOS SHARE utility. The error message 'Mangler definisjonsfil for PC-NOTIS menyen - Trykk en tast' will occur. To run PC-NOTIS properly you must run without the DOS SHARE utility.
ND-895533.1 EN